首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic, wind-electric, diesel powered), few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) and solar photovoltaic (PV) array water pumping systems were analyzed individually and combined as a hybrid system. The objectives were to determine: (1) advantages or disadvantages of using a hybrid system over using a WT or a solar PV array alone; (2) if the WT or solar PV array interfered with the output of the other; and (3) which hybrid system was the most efficient for the location. The WT used in the analysis was rated at 900 W alternating current (AC). There were three different solar PV arrays analyzed, and they were rated at 320, 480, and 640 W direct current (DC). A rectifier converted the 3-phase variable voltage AC output from the WT to DC before combining it with the solar PV array DC output. The combined renewable energies powered a single helical pump. The independent variable used in the hybrid WT/PV array analysis was in units of W/m2. The peak pump efficiency of the hybrid systems at Bushland, TX occurred for the 900 W WT combined with the 640 W PV array. The peak pump efficiencies at a 75 m pumping depth of the hybrid systems were: 47% (WT/320 W PV array), 51% (WT/480 W PV array), and 55% (WT/640 W PV array). Interference occurred between the WT and the different PV arrays (likely due to voltage mismatch between WT and PV array), but the least interference occurred for the WT/320 W PV array. This hybrid system pumped 28% more water during the greatest water demand month than the WT and PV systems would have pumped individually. An additional controller with a buck/boost converter is discussed at end of paper for improvement of the hybrid WT/PV array water pumping system.  相似文献   

2.
The burning of depleting fossil fuels for power generation has detrimental impact on human life and climate. In view of this, renewable solar energy sources are being increasingly exploited to meet the energy needs. Moreover, solar photovoltaic (PV)–diesel hybrid system technology promises lot of opportunities in remote areas which are far from utility grid and are driven by diesel generators. Integration of PV systems with the diesel plants is being disseminated worldwide to reduce diesel fuel consumption and to minimize atmospheric pollution. The Kingdom of Saudi Arabia (K.S.A.) being endowed with high intensity of solar radiation, is a prospective candidate for deployment of PV systems. Also, K.S.A. has large number of remote scattered villages. The aim of this study is to analyze solar radiation data of Rafha, K.S.A., to assess the techno-economic feasibility of hybrid PV–diesel–battery power systems to meet the load requirements of a typical remote village Rawdhat Bin Habbas (RBH) with annual electrical energy demand of 15,943 MWh. Rafha is located near RBH. The monthly average daily global solar radiation ranges from 3.04 to 7.3 kWh/m2. NREL's HOMER software has been used to perform the techno-economic evaluation. The simulation results indicate that for a hybrid system composed of 2.5 MWp capacity PV system together with 4.5 MW diesel system (three 1.5 MW units) and a battery storage of 1 h of autonomy (equivalent to 1 h of average load), the PV penetration is 27%. The cost of generating energy (COE, US$/kWh) from the above hybrid system has been found to be 0.170$/kWh (assuming diesel fuel price of 0.1$/l). The study exhibits that the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets. Concurrently, emphasis has been placed on: un-met load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as: PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), COE of different hybrid systems, etc. The decrease in carbon emissions by using the above hybrid system is about 24% as compared to the diesel-only scenario.  相似文献   

3.
Solar photovoltaic (PV) hybrid system technology is a hot topic for R&D since it promises lot of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (KSA) being endowed with fairly high degree of solar radiation is a potential candidate for deployment of PV systems for power generation. Literature indicates that commercial/residential buildings in KSA consume an estimated 10–45% of the total electric energy generated. In the present study, solar radiation data of Dhahran (East-Coast, KSA) have been analyzed to assess the techno-economic viability of utilizing hybrid PV–diesel–battery power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kW h). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kW h/m2. NREL's HOMER software has been used to carry out the techno-economic viability. The simulation results indicate that for a hybrid system comprising of 80 kWp PV system together with 175 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 26%. The cost of generating energy (COE, US$/kW h) from the above hybrid system has been found to be 0.149 $/kW h (assuming diesel fuel price of 0.1 $/L). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Emphasis has also been placed on unmet load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), cost of PV–diesel–battery systems, COE of different hybrid systems, etc.  相似文献   

4.
This work presents the main features of the new power plant that comprises the modified reversible hydroelectric (HE) power plant operating together with the photovoltaic (PV) power plant. Such Solar Hydroelectric Power Plant (SHE) uses solar energy as the only input for production of solar and hydro energy. Thereat, water reservoir serves for daily and seasonal energy storage, thus basically solving the problem of energy storage, which is the biggest problem of wider use of solar energy. The most expensive part of SHE is the PV generator, whose optimal sizing is essential for providing energetic independence of a settlement or isolated consumer. A systematic approach that includes all relevant elements of this system has been implemented for optimal sizing of the PV power plant. The developed model was used in analysis of certain parameters of the SHE system. The results of the analysis show the system characteristics and that the proposed model describes the operation of the power plant very well. The feasibility and characteristics of the power plant were tested on electric energy supply of the island of Vis in Croatia. It has been established that the system is real, feasible and can be very successfully applied on different locations, for different consumers and can vary in size. The prerequisite for realization of such system is the construction of a modified reversible HE power plant. The presented SHE represents a permanently sustainable energy source that can continuously provide power supply to a consumer, using exclusively natural and renewable energy sources, without causing harmful effects on the environment.  相似文献   

5.
Renewable energy encompasses a broad range of energy resources. Bangladesh is known to have a good potential for renewable energy, but so far no systematic study has been done to quantify this potential for power generation. This paper estimates the potential of renewable energy resources for power generation in Bangladesh from the viewpoint of different promising available technologies. Estimation of the potential of solar energy in Bangladesh is done using a GIS-based GeoSpatial Toolkit (GsT), Hybrid System Optimization Model for Electric Renewables (HOMER) model and NASA Surface Meteorology and Solar Energy (SSE) solar radiation data. The potential of wind energy is estimated by developing a Bangladesh wind map using NASA SSE wind data and HOMER model. A review of country's biomass and hydro potential for electricity generation is presented. The technical potential of gird-connected solar PV is estimated at 50,174 MW. Assuming that 1000 h per year of full power is the feasible threshold for the exploitation of wind energy, the areas that satisfy this condition in the country would be sufficient for the installation of 4614 MW of wind power. The potential of biomass-based and small hydro power plants is estimated at 566 and 125 MW, respectively. The renewable energy resources cannot serve as alternative to conventional energy resources, yet they may serve to supplement the long-term energy needs of Bangladesh to a significant level.  相似文献   

6.
The work presented in this article aims to investigate a PV/T hybrid solar window on a system level. A PV/T hybrid is an absorber on which solar cells have been laminated. The solar window is a PV/T hybrid collector with tiltable insulated reflectors integrated into a window. It simultaneously replaces thermal collectors, PV-modules and sunshade. The building integration lowers the total price of the construction since the collector utilizes the frame and the glazing in the window. When it is placed in the window a complex interaction takes place. On the positive side is the reduction of the thermal losses due to the insulated reflectors. On the negative side is the blocking of solar radiation that would otherwise heat the building passively. This limits the performance of the solar window since a photon can only be used once. To investigate the sum of such complex interaction a system analysis has to be performed. In this paper results are presented from such a system analysis showing both benefits and problems with the product. The building system with individual solar energy components, i.e. solar collector and PV modules, of the same size as the solar window, uses 1100 kW h less auxiliary energy than the system with a solar window. However, the solar window system uses 600 kW h less auxiliary energy than a system with no solar collector.  相似文献   

7.
The advantage of PV–thermal hybrid systems is their high total efficiency. By using concentrating hybrid systems, the cost per energy produced is reduced due to simultaneous heat and electricity production and a reduced PV cell area. In this article, the optical efficiency of a water-cooled PV–thermal hybrid system with low concentrating aluminium compound parabolic concentrators is discussed. The system was built in 1999 in Älvkarleby, Sweden (60.5° N, 17.4° E) with a geometric concentration ratio of C=4 and 0.5 kWp electric power. The yearly output is 250 kWh of electricity per square metre solar cell area and 800 kWh of heat at low temperatures per square metre solar cell area. By using numerical data from optical measurements of the components (glazing, reflectors, and PV cells) the optical efficiency, ηopt, of the PV–CPC system has been determined to be 0.71, which is in agreement with the optical efficiency as determined from thermal and electrical measurements. Calculations show that optimised antireflection-treated glazing and reflectors could further increase the electric power yield.  相似文献   

8.
In this paper, an attempt has been made to evaluate and compare the energy matrices of a hybrid photovoltaic thermal (HPVT) water collector under constant collection temperature mode with five different types of PV modules namely c-Si, p-Si, a-Si (thin film), CdTe and CIGS. The analysis is based on overall thermal energy and exergy outputs from HPVT water collector. The temperature dependent electrical efficiency has also been calculated under composite climate of New Delhi, India.It is observed that c-Si PV module is best alternative for production of electrical power. Maximum annual overall thermal energy and exergy is obtained for c-Si PV module. The maximum and minimum EPBT of 1.01 and 0.66 years on energy basis is obtained for c-Si and CIGS respectively, whereas on exergy basis maximum EPBT of 5.72 years is obtained for a-Si and minimum of 3.44 in obtained for CIGS PV module. EPF and LCCE increase with increasing the life time of the system.  相似文献   

9.
《Applied Thermal Engineering》2007,27(8-9):1259-1270
Hybrid photovoltaic/thermal (PV/T) systems consist of PV modules and heat extraction units mounted together. These systems can simultaneously provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation than plain photovoltaics. Industries show high demand of energy for both heat and electricity and the hybrid PV/T systems could be used in order to meet this requirement. In this paper the application aspects in the industry of PV/T systems with water heat extraction is presented. The systems are analyzed with TRNSYS program for three locations Nicosia, Athens and Madison that are located at different latitudes. The system comprises 300 m2 of hybrid PV/T collectors producing both electricity and thermal energy and a 10 m3 water storage tank. The work includes the study of an industrial process heat system operated at two load supply temperatures of 60 °C and 80 °C. The results show that the electrical production of the system, employing polycrystalline solar cells, is more than the amorphous ones but the solar thermal contribution is slightly lower. A non-hybrid PV system produces about 25% more electrical energy but the present system covers also, depending on the location, a large percentage of the thermal energy requirement of the industry considered. The economic viability of the systems is proven, as positive life cycle savings are obtained in the case of hybrid systems and the savings are increased for higher load temperature applications. Additionally, although amorphous silicon panels are much less efficient than the polycrystalline ones, better economic figures are obtained due to their lower initial cost, i.e., they have better cost/benefit ratio.  相似文献   

10.
11.
The main problem in using photovoltaic (PV) systems is the low energy conversion efficiency of PV cells. The efficiency of PV cells will decrease significantly as the temperature of the cells exceed to a certain limit. In order to increase the efficiency, it is necessary to reduce the operating temperature of array. One of the ways for improving the system operation is cooling PV cells with a thin film of water. The aim of this research is to study the effects of nominal power of array and system head on the operation of system by using this method. For this purpose, a photovoltaic water pumping system is installed in Kerman city (Latitude: 30 ° 17′ and longitude: 57 ° 50′) and different methods examined to reduce PV cells temperature. The most effective way was chosen and used in set. This method is based on providing water for cooling cells by the pump itself. Experiments show that with decreasing of array nominal power and increasing in system head, the power generated by the array increases significantly. This increases the panel and total efficiency and therefore the pump flow rate. This method is ineffective as the array nominal power increases significantly.  相似文献   

12.
A hybrid system design integrating a thermoelectric (TE) module has recently represented the advanced photovoltaic (PV) prototype with promoted efficiency for utilizing solar energy from the surroundings. Our present work during development of such a hybrid PV/TE system evaluates the thermal behaviors and the cooling performance associated with when integrating TE and heat sink modules. It has been noticed that a more effective structure through combining a heat sink with a TE module profits heat dissipation by cooling down the whole cell by ~ 8 °C, wherein the TE module itself demonstrates the cooling performance by ~ 27% enhancement in addition to its conventional role for electricity generation. Therefore, the PV/TE with a proper design can be used as a passive method for improving the cell efficiency as well as alleviating hot spot, which is typically occurring when the cell is unevenly heated during its operation. These results could be useful for further advancement on stability of power generation of a hybrid PV/TE system and may also be important for developing high-powered light emit diode.  相似文献   

13.
This paper presents the numerical modeling and optimization of a spectrum splitting photovoltaic–thermoelectric (PV–TE) hybrid system. In this work, a simulation model is established in consideration of solar concentration levels and several heat dissipation rates. Exemplarily, the performance of a hybrid system composed of a GaAs solar cell and a skutterudites CoSb3 solar thermoelectric generator (TEG) is simulated. Analysis under different conditions has been carried out to evaluate the electrical and thermal performance of the hybrid system. Results show that the cutoff-wavelength of the GaAs–CoSb3 hybrid system is mainly determined by the band gap of solar cell, when the solar concentration ratio is ranged between 550 to 770 and heat transfer coefficient h = 3000–4500 W/m2 K, the hybrid system has good electrical performance and low operating temperatures. Based on the analysis of the GaAs–CoSb3 hybrid system, guidelines for the PV–TE system design are proposed. It is also compared with a PV-only system working under the same cooling condition; results show that the PV–TE hybrid system is more suitable for working under high concentrations.  相似文献   

14.
Pico-hydro (pH) and photovoltaic (PV) hybrid systems incorporating a biogas generator have been simulated for remote villages in Cameroon using a load of 73 kWh/day and 8.3 kWp. Renewable energy systems were simulated using HOMER, the load profile of a hostel in Cameroon, the solar insolation of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be either 0.352 €/kWh for a 5 kW pico-hydro generator with 72 kWh storage or 0.396 €/kWh for a 3 kWp photovoltaic generator with 36 kWh storage. These energy costs were obtained with a biomass resource cost of 25 €/tonne. The pH and PV hybrid systems both required the parallel operation of a 3.3 kW battery inverter with a 10 kW biogas generator. The pH/biogas/battery systems simulated for villages located in the south of Cameroon with a flow rate of at least 92 l/s produced lower energy costs than PV/biogas/battery systems simulated for villages in the north of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 12.9 km for pH/biogas/battery systems and 15.2 km for PV/biogas/battery systems respectively. Investments in biogas based renewable energy systems could thus be considered in the National Energy Action Plan of Cameroon for the supply of energy to key sectors involved in poverty alleviation.  相似文献   

15.
《Journal of power sources》2006,162(2):943-948
This paper describes a novel method of modelling an energy store used to match the power output from a wind turbine and a solar PV array to a varying electrical load. The model estimates the fraction of time that an energy store spends full or empty. It can also estimate the power curtailed when the store is full and the unsatisfied demand when the store is empty. The new modelling method has been validated against time–stepping methods and shows generally good agreement over a wide range of store power ratings, store efficiencies, wind turbine capacities and solar PV capacities.Example results are presented for a system with 1 MW of wind power capacity, 2 MW of photovoltaic capacity, an energy store of 75% efficiency and a range of loads from 0 to 3 MW average.  相似文献   

16.
The near-exponential rise in tourist numbers and accelerating economic growth have challenged Tibetan energy supply and threaten its peculiar environment and valuable ecosystem. Exploitation of pollution free solar power may medicate this demand for energy. Here we shall provide a review of solar power development in Tibet. This region has a near inexhaustible source of solar energy due to its average annual radiation intensity of 6000–8000 MJ/m2, ranking it first in China and second after the Sahara worldwide. Currently, Tibet has 400 photovoltaic power stations with a total capacity of nearly 9 MW. In addition, 260,000 solar energy stoves, passive solar house heating covering 3 million square meters, and 400,000 m2 of passive solar water heaters are currently in use in Tibet. Although Tibet places first in applying solar energy in China, solar energy faces big challenges from hydroelectric power and the absence of local know-how. The new power generation capacity in Tibet's “11th Five-Year (2006–2010)” Plan focuses primarily on hydropower, PV power stations being relegated to a secondary role as supplementary to hydropower. Here it will be argued that this emphasis is incorrect and that solar energy should take first place in Tibet's energy development, as it is crucial in striving for a balance between economic development, booming tourism, and environmental protection.  相似文献   

17.
E.M. Nfah  J.M. Ngundam 《Solar Energy》2012,86(10):2935-2949
Photovoltaic hybrid systems (PVHS) with 2 days of energy autonomy are shown to be optimal options for the supply of the daily energy demands of 33 base transceiver stations of MTN Cameroon. PVHS were computed for all sites using the technical data for a 150 Wp mono-crystalline module, the site specific hourly load data, the average monthly solar radiation and temperature. Hourly solar radiation data for all sites were downloaded using the solar resource module of HOMER and geographical coordinates of the selected sites. The 3-hourly temperature data available on a website maintained NASA was used to generate average monthly hourly temperatures needed in the calculation of the output of solar modules. The energy costs and breakeven grid distances for possible power options were computed using the Net Present Value Technique and financial data for selected power system components. The results with a PV module cost of 7.5 €/Wp, a remote diesel price of 1.12 €/l, a general inflation rate of 5% and a fuel escalation of 10% showed that the annual operational times of the diesel generator were in the range 3–356 h/year with renewable energy fractions in the range 0.89–1.00. However, only 22 PVHS had two parallel battery strings as stipulated in the request for proposal launched by MTN Cameroon in 2008. The PV array sizes evaluated for the 22 PVHS were found to be the range 2.4–10.8 kWp corresponding to daily energy demands in the range 7.31–31.79 kW h/d. The energy costs and breakeven grid distances determined were in the ranges 0.81–1.32 €/kW h and 10.75–32.00 km respectively.  相似文献   

18.
《Applied Energy》2007,84(2):222-237
A flat-box aluminum-alloy photovoltaic and water-heating system designed for natural circulation was constructed. The hybrid photovoltaic/thermal (PV/T) collector was an integration of single-crystalline silicon cells into a solar thermal collector. The product was able to generate electricity and hot water simultaneously. Outdoor tests on an improved prototype were conducted in a moderate climate zone. Then dynamic simulation runs, using a validated numerical model, were performed. These included sensitivity tests with variations of the system water mass, PV cell covering factor, and front glazing transmissivity. The test results showed that the characteristic daily primary-energy saving could reach up to 65% for this system with a PV cell covering factor 0.63 and front glazing transmissivity of 0.83, when the hot water load per unit heat-collecting area exceeded 80 kg/m2. The simulated results indicated that the higher the PV cell covering factor and the glazing transmissivity, the better the overall system performance. The effects were quantified.  相似文献   

19.
This paper presents dynamic behavior and simulation results in a stand-alone hybrid power generation system of wind turbine, microturbine, solar array and battery storage. The hybrid system consists of a 195 kW wind turbine, an 85 kW solar array; a 230 kW microturbine and a 2.14 kAh lead acid battery pack optimized based on economic analysis using genetic algorithm (GA). At first, a developed Lyapunov model reference adaptive feedback linearization method accompanied by an indirect space vector control is applied for extraction of maximum energy from a variable speed wind power generation system. Then, a fuzzy logic controller is designed for the mentioned purpose and its performance is compared with the proposed adaptive controller. For meeting more load demands, the solar array is integrated with the wind turbine. In addition, the microturbine and the battery storage are combined with the wind and solar power generation system as a backup to satisfy the load demand under all conditions.A supervisory controller is designed in order to manage energy between the maximum energy captured from the wind turbine/solar arrays, and consumed energies of the load, dump load, battery state of charge (SOC), and generated energy by the microturbine. Dynamic modeling and simulation are accomplished using MATLAB Simulink? 7.2.  相似文献   

20.
A study of a photovoltaic (PV) array and inverter system installed in San Diego, California, was conducted in order to determine the energy losses due to inverter saturation (capping of inverter power output due to the PV array power output exceeding the inverter maximum power rating). Two mechanisms of saturation were considered: cloud enhancement (refers to an increased diffuse component of irradiance caused by clouds surrounding the unobstructed solar disk) and clear sky exceedance. For inverter sizing ratios (defined as R = inverter maximum AC output rating/PV DC rating) of R = 0.81 and R = 0.87 the annual energy losses as a percent of annual energy production were 2.65% and 2.20% using 1-s measurement resolution. Annual energy losses were calculated by aggregating the difference between modeled power (assuming no saturation occurred) and measured power. Losses due to cloud enhancement dominated the total losses, especially for R = 0.87. Increasing inverter size reduces saturation losses during high irradiance conditions, but decreases inverter conversion efficiency under low irradiance conditions. Increasing the sizing ratio to R = 1.22 would result in a maximum amount of energy production at our site. Averaging on timescales from 1-s to 1-h was performed to demonstrate that cloud enhancement losses can only be quantified using 10-s or finer measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号