首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
In this study, the energy and exergy analysis of Al-Hussein power plant in Jordan is presented. The primary objectives of this paper are to analyze the system components separately and to identify and quantify the sites having largest energy and exergy losses. In addition, the effect of varying the reference environment state on this analysis will also be presented. The performance of the plant was estimated by a component-wise modeling and a detailed break-up of energy and exergy losses for the considered plant has been presented. Energy losses mainly occurred in the condenser where 134 MW is lost to the environment while only 13 MW was lost from the boiler system. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system (77%) followed by the turbine (13%), and then the forced draft fan condenser (9%). In addition, the calculated thermal efficiency based on the lower heating value of fuel was 26% while the exergy efficiency of the power cycle was 25%. For a moderate change in the reference environment state temperature, no drastic change was noticed in the performance of major components and the main conclusion remained the same; the boiler is the major source of irreversibilities in the power plant. Chemical reaction is the most significant source of exergy destruction in a boiler system which can be reduced by preheating the combustion air and reducing the air–fuel ratio.  相似文献   

2.
In this paper, exergy analysis of a heat-matched bagasse-based cogeneration plant of a typical 2500 tcd sugar factory, using backpressure and extraction condensing steam turbine is presented. In the analysis, exergy methods in addition to the more conventional energy analyses, are employed to evaluate overall and component efficiencies and to identify and assess the thermodynamic losses. The analysis is carried out for a wide range of steam inlet conditions selected around the sugar industry’s export cogeneration plant. The results show that, at optimal steam inlet conditions of 61 bar and 475 °C, the backpressure steam turbine cogeneration plant perform with energy and exergy efficiency of 0.863 and 0.307 and condensing steam turbine plant perform with energy and exergy efficiency of 0.682 and 0.260, respectively. Boiler is the least efficient component and turbine is the most efficient component of the plant.  相似文献   

3.
《Applied Thermal Engineering》2007,27(8-9):1377-1385
In this study, the energy and exergy analysis have been applied to the Çatalağzı power plant in Zonguldak, Turkey. The fuel used in this power plant was low calorific value coal middlings with particle size below 0.5 mm. The heat loss of each components were determined by energy analysis and the irreversibility rates (or exergy destruction rates) of whole plant were obtained for different ambient temperatures by the exergy analysis. The ambient temperature was selected within the range of 5–35 °C. The percentage efficiency defects of each components (or the ratios of the irreversibility rates to the fuel exergy rate) and the rational efficiency, the exergy efficiencies of the boiler, the turbine, the pump, the heaters and the condenser were determined for different ambient temperatures.It was found that the efficiency defect of boiler had strong effects on the total efficiency defect and the rational efficiency of the plant. The ambient temperature had high effect on the changes of the irreversibility of boiler (or efficiency defect of boiler) but it had low effect on outer components of the plant.  相似文献   

4.
In this study energy, exergy and exergoeconomic analysis of the Afyon geothermal district heating system (AGDHS) in Afyon, Turkey is performed through thermodynamic performances and thermo-economic assessments. In the analysis, actual system data are used to assess the district heating system performance, energy and exergy efficiencies, exergy losses and loss cost rates. Energy and exergy losses throughout the AGDHS are quantified and illustrated in the flow diagram. The energy and exergy efficiencies of the overall system are found to be 37.59% and 47.54%, respectively. The largest exergy loss occurs in the heat exchangers with 14.59% and then in the reinjection wells with 14.09%. Besides, thermo-economic evaluations of the AGDHS are given in table. Energy and exergy loss rates for the AGDHS are estimated to be 5.36 kW/$ and 0.2  kW/$, respectively.  相似文献   

5.
The present study undertakes an exergy and reliability analysis of wind turbine systems and applies to a local one in Turkey: the exergy performance and reliability of the small wind turbine generator have been evaluated in a demonstration (1.5 kW) in Solar Energy Institute of Ege University (latitude 38.24 N, longitude 27.50 E), Izmir, Turkey. In order to extract the maximum possible power, it is important that the blades of small wind turbines start rotating at the lowest possible wind speed. The starting performance of a three-bladed, 3 m diameter horizontal axis wind turbine was measured in field tests. The average technical availability, real availability, capacity factor and exergy efficiency value have been analyzed from September 2002 to November 2003 and they are found to be 94.20%, 51.67%, 11.58%, and 0–48.72%, respectively. The reliability analysis has also been done for the small wind turbine generator. The failure rate is high to an extent of 2.28×10−4 h−1 and the factor of reliability is found to be 0.37 at 4380 h. If failure rate can be decreased, not only this system but also other wind turbine systems of real availability, capacity factor and exergy efficiency will be improved.  相似文献   

6.
The objective of this paper is to perform the energy, exergy and exergoeconomic analysis for the Hamedan steam power plant. In the first part of the paper, the exergy destruction and exergy loss of each component of this power plant is estimated. Moreover, the effects of the load variations and ambient temperature are calculated in order to obtain a good insight into this analysis. The exergy efficiencies of the boiler, turbine, pump, heaters and the condenser are estimated at different ambient temperatures. The results show that energy losses have mainly occurred in the condenser where 306.9 MW is lost to the environment while only 67.63 MW has been lost from the boiler. Nevertheless, the irreversibility rate of the boiler is higher than the irreversibility rates of the other components. It is due to the fact that the combustion reaction and its high temperature are the most significant sources of exergy destruction in the boiler system, which can be reduced by preheating the combustion air and reducing the air–fuel ratio. When the ambient temperature is increased from 5 to 24°C, the irreversibility rate of the boiler, turbine, feed water heaters, pumps and the total irreversibility rate of the plant are increased. In addition, as the load varies from 125 to 250 MW (i.e. full load) the exergy efficiency of the boiler and turbine, condenser and heaters are increased due to the fact that the power plant is designed for the full load. In the second part of the paper, the exergoeconomic analysis is done for each component of the power plant in order to calculate the cost of exergy destruction. The results show that the boiler has the highest cost of exergy destruction. In addition, an optimization procedure is developed for that power plant. The results show that by considering the decision variables, the cost of exergy destruction and purchase can be decreased by almost 17.11%. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
《Energy Conversion and Management》2005,46(15-16):2530-2552
This paper is concerned with the energy and exergy analyses of the single layer drying process of potato slices via a cyclone type dryer. Using the first law of thermodynamics, an energy analysis was performed to estimate the ratios of energy utilization. An exergy analysis was accomplished to determine the location, type and magnitude of the exergy losses during the drying process by applying the second law of thermodynamics. It was concluded that the exergy losses took place mostly in the 1st tray where the available energy was less utilized during the single layer drying process of potato slices. It is emphasized that the potato slices are sufficiently dried in the ranges between 60 and 80 °C and 20–10% relative humidity at 1 and 1.5 ms−1 of drying air velocity during 10–12 h despite the exergy losses of 0–1.796 kJ s−1.  相似文献   

8.
The energy and exergy flow for a space heating systems of a typical residential building of natural ventilation system with different heat generation plants have been modeled and compared. The aim of this comparison is to demonstrate which system leads to an efficient conversion and supply of energy/exergy within a building system.The analysis of a fossil plant heating system has been done with a typical building simulation software IDA–ICE. A zone model of a building with natural ventilation is considered and heat is being supplied by condensing boiler. The same zone model is applied for other cases of building heating systems where power generation plants are considered as ground and air source heat pumps at different operating conditions. Since there is no inbuilt simulation model for heat pumps in IDA–ICE, different COP curves of the earlier studies of heat pumps are taken into account for the evaluation of the heat pump input and output energy.The outcome of the energy and exergy flow analysis revealed that the ground source heat pump heating system is better than air source heat pump or conventional heating system. The realistic and efficient system in this study “ground source heat pump with condenser inlet temperature 30 °C and varying evaporator inlet temperature” has roughly 25% less demand of absolute primary energy and exergy whereas about 50% high overall primary coefficient of performance and overall primary exergy efficiency than base case (conventional system). The consequence of low absolute energy and exergy demands and high efficiencies lead to a sustainable building heating system.  相似文献   

9.
《Energy》2006,31(14):2699-2709
Cogeneration plants for simultaneous production of water and electricity are widely used in the Arabian Gulf region. They have proven to be more thermodynamically efficient and economically feasible than single purpose power generation and water production plants. Yet, there is no standard or universally applied methodology for determining unit cost of electric power generation and desalinated water production by dual purpose plants.A comprehensive literature survey to critically assess and evaluate different methods for cost application in power/water cogeneration plants is reported in this paper. Based on this analysis, an in-depth thermoeconomic study is carried out on a selected power/water cogeneration plant that employs a regenerative Rankine cycle. The system incorporates a boiler, back pressure turbine (supplying steam to two MSF distillers), a deaerator and two feed water heaters. The turbine generation is rated at 118 MW, while MSF distiller is rated at 7.7 MIGD at a top brine temperature of 105 °C. An appropriate costing procedure based on the available energy accounting method which divides benefits of the cogeneration configuration equitably between electricity generation and water production is used to determine the unit costs of electricity and water. Capital charges of common equipment such as the boiler, deaerator and feed water heaters as well as boiler fuel costs are distributed between power generated and desalinated water according to available energy consumption of the major subsystems. A detailed sensitivity analysis was performed to examine the impact of the variation of fuel cost, load and availability factors in addition to capital recovery factor on electricity and water production costs.  相似文献   

10.
《Journal of power sources》2005,145(2):502-514
An integrated ethanol fuelled proton exchange membrane fuel cell (PEMFC) power system was investigated following a second law exergy analysis. The system was assumed to have the typical design for automobile applications and was comprised of a vaporizer/mixer, a steam reformer, a CO-shift reactor, a CO-remover (PROX) reactor, a PEMFC and a burner. The exergy analysis was applied for different PEMFC power and voltage outputs assuming the ethanol steam reforming at about 600 K and the CO-shift reaction at about 400 K. A detailed parametric analysis of the plant is presented and operation guidelines are suggested for effective performance. In every case, the exergy analysis method is proved to allow an accurate allocation of the deficiencies of the subsystems of the plant and serves as a unique tool for essential technical improvements.  相似文献   

11.
This paper presents a novel polygeneration system that integrates the acetylene process and the use of fuel cells. The system produces acetylene and power by a process of the partial oxidation/combustion (POC) of natural gas process, a water–gas shift reactor, a fuel cell and a waste heat boiler auxiliary system to recover the exhaust heat and gas from the fuel cell. Based on 584.3 kg/h of natural gas feedstock, a POC reactor temperature of 1773 K, an absorber pressure of 1.013 MPa and a degasser pressure of 0.103 MPa, the simulation results show that the new system achieved acetylene production of 1.9 MW, net electricity production of 1.7 MW, power generation efficiency of 26.8% and exergy efficiency of 43.4%, which was 20.2% higher than the traditional acetylene production process. The new system's exergy analysis and the flow rate of the products were investigated, and the results revealed that the energy conversion and systematic integration mechanism demonstrated the improvement of natural gas energy conversion efficiency.  相似文献   

12.
This paper is Part 2 of the study on the exergetic and thermoeconomic analysis of diesel engine powered cogeneration (DEPC) systems. In Part 1, formulations and procedure for such a comprehensive analysis are provided while this paper provides an application of the developed formulation that considers an actual DEPC plant installed in Gaziantep, Turkey. The plant has a total installed electricity and steam generation capacities of 25.3 MW and 8.1 tons/h at 170 °C, respectively. Exergy destructions, exergy efficiencies, exergetic cost allocations, and various exergoeconomic performance parameters are determined for the entire plant and its components. The exergy efficiency of the plant is determined to be 40.6%. The exergoeconomic analysis is based on specific cost method (SPECO) and it is determined that the specific unit exergetic cost of the power produced by the plant is 10.3 $/GJ.  相似文献   

13.
An analysis of the coefficient of performance (COP), specific cooling power (Qscp) and exergy losses for a four-bed adsorption heat pump is presented. A composite adsorbent (SWS-1L) and water are the adsorption pair. An optimum cycle time, corresponding to a maximum specific cooling power, was found. This maximum specific cooling power increases almost linearly with the regeneration temperature. For the operation corresponding to the maximum specific cooling power at the regeneration temperature of 120 °C, using the SWS-1L composite adsorbent to substitute a regular-density silica gel in the adsorbers, the COP and Qscp values can be increased by 51% and 38.4%, respectively. At the regeneration temperature of 100 °C and the mode operating time of 360 s, the second-law efficiency of the adsorption heat pump is 20.4%. The cycle exergy loss mainly occurs in the adsorbers. The exergy losses in the condenser and evaporator are small. Among the four processes in the adsorbers, the precooling and preheating processes result in 41.55% and 28.96% of the cycle exergy loss, respectively, while the adsorption and regeneration processes cause 8.44% and 18.97%, respectively. The exergy losses in the precooling and preheating processes mainly result from heat transfer through a significant temperature difference.  相似文献   

14.
Historically, the design of hybrid solar photovoltaic thermal (PVT) systems has focused on cooling crystalline silicon (c-Si)-based photovoltaic (PV) devices to avoid temperature-related losses. This approach neglects the associated performance losses in the thermal system and leads to a decrease in the overall exergy of the system. Consequently, this paper explores the use of hydrogenated amorphous silicon (a-Si:H) as an absorber material for PVT in an effort to maintain higher and more favorable operating temperatures for the thermal system. Amorphous silicon not only has a smaller temperature coefficient than c-Si, but also can display improved PV performance over extended periods of higher temperatures by annealing out defect states from the Staebler–Wronski effect. In order to determine the potential improvements in a-Si:H PV performance associated with increased thicknesses of the i-layers made possible by higher operating temperatures, a-Si:H PV cells were tested under 1 sun illumination (AM1.5) at temperatures of 25 °C (STC), 50 °C (representative PV operating conditions), and 90 °C (representative PVT operating conditions). PV cells with an i-layer thicknesses of 420, 630 and 840 nm were evaluated at each temperature. Results show that operating a-Si:H-based PV at 90 °C, with thicker i-layers than the cells currently used in commercial production, provided a greater power output compared to the thinner cells operating at either PV or PVT operating temperatures. These results indicate that incorporating a-Si:H as the absorber material in a PVT system can improve the thermal performance, while simultaneously improving the electrical performance of a-Si:H-based PV.  相似文献   

15.
《Energy Conversion and Management》2005,46(11-12):1692-1702
Performance of an actual Diesel engine power plant with a rated output of 120 MW is analyzed based on the first and second laws of thermodynamics. The plant consists of seven identical Diesel engines and various subsystems including turbochargers, fuel heating units and heat exchangers performing various useful tasks. The engine runs on heavy fuel oil, and the pollutant emissions from the engine are greatly reduced by effective treatment systems. The characteristics and performance parameters of the internal combustion engines of the plant are evaluated. The mass, energy and exergy balances are verified for each flow stream in the power plant. The work and heat interactions, the exergy losses and the efficiencies of various components based on both energy and exergy concepts are evaluated. The thermal and the exergy efficiencies of the plant are determined to be 47% and 44%, respectively. The engine irreversibilities are due mostly to the irreversible combustion process and account for 32% of the total exergy input and 57% of the total irreversibilities in the plant. Most of the remaining irreversibilities in the plant occur in the desulphurization, intercooler, compressor and lubrication oil cooler units. The results should provide a realistic and meaningful ground for the performance evaluation of Diesel engine power units, and it may be used in the design and analysis of such systems.  相似文献   

16.
The energy and exergy analyses of the drying process of olive mill wastewater (OMW) using an indirect type natural convection solar dryer are presented. Olive mill wastewater gets sufficiently dried at temperatures between 34 °C and 52 °C. During the experimental process, air relative humidity did not exceed 58%, and solar radiation ranged from 227 W/m2 to 825 W/m2. Drying air mass flow was maintained within the interval 0.036–0.042 kg/s. Under these experimental conditions, 2 days were needed to reduce the moisture content to approximately one-third of the original value, in particular from 3.153 gwater/gdry matter down to 1.000 gwater/gdry matter.Using the first law of thermodynamics, energy analysis was carried out to estimate the amounts of energy gained from solar air heater and the ratio of energy utilization of the drying chamber. Also, applying the second law, exergy analysis was developed to determine the type and magnitude of exergy losses during the solar drying process. It was found that exergy losses took place mainly during the second day, when the available energy was less used. The exergy losses varied from 0 kJ/kg to 0.125 kJ/kg for the first day, and between 0 kJ/kg and 0.168 kJ/kg for the second. The exergetic efficiencies of the drying chamber decreased as inlet temperature was increased, provided that exergy losses became more significant. In particular, they ranged from 53.24% to 100% during the first day, and from 34.40% to 100% during the second.  相似文献   

17.
A solar transcritical CO2 power cycle for hydrogen production is studied in this paper. Liquefied Natural Gas (LNG) is utilized to condense the CO2. An exergy analysis of the whole process is performed to evaluate the effects of the key parameters, including the boiler inlet temperature, the turbine inlet temperature, the turbine inlet pressure and the condensation temperature, on the system power outputs and to guide the exergy efficiency improvement. In addition, parameter optimization is conducted via Particle Swarm Optimization to maximize the exergy efficiency of hydrogen production. The exergy analysis indicates that both the solar and LNG equally provide exergy to the CO2 power system. The largest amount of exergy losses occurs in the solar collector and the condenser due to the great temperature differences during the heat transfer process. The exergy loss in condenser could be greatly reduced by increasing the LNG temperature at the inlet of the condenser. There exists an optimum turbine inlet pressure for achieving the maximum exergy efficiency. With the optimized turbine inlet pressure and other parameters, the system is able to provide 11.52 kW of cold exergy and 2.1 L/s of hydrogen. And the exergy efficiency of hydrogen production could reach 12.38%.  相似文献   

18.
In the European Union, electricity production from wind energy is projected to increase by approximately 16% until 2020. The Austrian energy plan aims at increasing the currently installed wind power capacity from approximately 1 GW to 3 GW until 2020 including an additional capacity of 700 MW until 2015. The aim of this analysis is to assess economically viable wind turbine sites under current feed-in tariffs considering constraints imposed by infrastructure, the natural environment and ecological preservation zones in Austria. We analyze whether the policy target of installing an additional wind power capacity of 700 MW until 2015 is attainable under current legislation and developed a GIS based decision system for wind turbine site selection.Results show that the current feed-in tariff of 9.7 ct kW h−1 may trigger an additional installation of 3544 MW. The current feed-in tariff can therefore be considered too high as wind power deployment would exceed the target by far. Our results indicate that the targets may be attained more cost-effectively by applying a lower feed-in tariff of 9.1 ct kW h−1. Thus, windfall profits at favorable sites and deadweight losses of policy intervention can be minimized while still guaranteeing the deployment of additional wind power capacities.  相似文献   

19.
This paper presents a new method for the optimisation of the mirror element spacing arrangement and operating temperature of linear Fresnel reflectors (LFR). The specific objective is to maximise available power output (i.e. exergy) and operational hours whilst minimising cost. The method is described in detail and compared to an existing design method prominent in the literature. Results are given in terms of the exergy per total mirror area (W/m2) and cost per exergy (US $/W). The new method is applied principally to the optimisation of an LFR in Gujarat, India, for which cost data have been gathered. It is recommended to use a spacing arrangement such that the onset of shadowing among mirror elements occurs at a transversal angle of 45°. This results in a cost per exergy of 2.3 $/W. Compared to the existing design approach, the exergy averaged over the year is increased by 9% to 50 W/m2 and an additional 122 h of operation per year are predicted. The ideal operating temperature at the surface of the absorber tubes is found to be 300 °C. It is concluded that the new method is an improvement over existing techniques and a significant tool for any future design work on LFR systems.  相似文献   

20.
The process of charging of an encapsulated ice thermal energy storage device (ITES) is thermally modeled here through heat transfer and thermodynamic analyses. In heat transfer analysis, two different temperature profile cases, with negligible radial and/or stream-wise conduction are investigated for comparison, and the temperature profiles for each case are analyzed in an illustrative example. After obtaining temperature profiles through heat transfer analysis, a comprehensive thermodynamic study of the system is conducted. In this regard, energy, thermal exergy and flow exergy efficiencies, internal and external irreversibilities corresponding to flow exergy, as well as charging times are investigated. The energy efficiencies are found to be more than 99%, whereas the thermal exergy efficiencies are found to vary between 40% and 93% for viable charging times. The flow exergy efficiency varies between 48% and 88% for the flows and inlet temperatures selected. For a flow rate of 0.00164 m3/s, the maximum flow exergy efficiency occurs with an inlet temperature of 269.7 K, corresponding to an efficiency of 84.3%. For the case where the flow rate is 0.0033 m3/s, the maximum flow exergy efficiency becomes 87.9% at an inlet temperature of 270.7 K. The results confirm the fact that energy analyses, and even thermal exergy analyses, may lead to some unrealistic efficiency values. This could prove troublesome for designers wishing to optimize performance. For this reason, the flow exergy model provides the most useful information for those wishing to improve performance and reduce losses in such ITES systems.  相似文献   