首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Entransy is a new concept developed in recent years to measure the transport ability of heat at a temperature in conduction and convection. This paper develops the concept of entransy flux for thermal radiation in enclosures with opaque surfaces. The entransy balance equation and entransy dissipation function are derived. The minimum principle of radiative entransy loss is developed. The potentials and the heat fluxes distribution which meet the Stefan–Boltzmann’s law and the energy balance equation would make the radiative entransy loss minimum if the net heat flux of each surface or the thermal potentials of the surfaces are given. The extremum entransy dissipation principles (EEDP) for thermal radiation are developed. The minimum radiative entransy dissipation leads to the minimum average radiative thermal potential difference for prescribed total heat exchange and the maximum radiative entransy dissipation leads to the maximum heat exchange for prescribed average radiative thermal potential difference. The minimum and maximum principle can be concluded into the minimum thermal resistance principle (MTRP) for thermal radiation by defining the thermal resistance with the entransy dissipation. The EEDP or MTRP is proved to be reliable when they are used to optimize some radiative heat transfer problems, and a comparison is made between the minimum principle of entropy generation and the EEDP.  相似文献   

2.
Fang Yuan  Qun Chen 《Energy》2011,36(9):5476-5485
Improving heat transfer performance is very beneficial to energy conservation because heat transfer processes widely existed in energy utilization systems. In this contribution, in order to effectively optimize convective heat transfer, such two principles as the field synergy principle and the entransy dissipation extremum principle are investigated to reveal the physical nature of the entransy dissipation and its intrinsic relationship with the field synergy degree. We first established the variational relations of the entransy dissipation and the field synergy degree with the heat transfer performance, and then derived the optimization equation of the field synergy principle and made comparison with that of the entransy dissipation extremum principle. Finally the theoretical analysis is then validated by the optimization results in both a fin-and-flat tube heat exchanger and a foursquare cavity. The results show that, for prescribed temperature boundary conditions, the above two optimization principles both aim at maximizing the total heat flow rate and their optimization equations can effectively obtain the best flow pattern. However, for given heat flux boundary conditions, only the optimization equation based on the entransy dissipation extremum principle intends to minimize the heat transfer temperature difference and could get the optimal velocity and temperature fields.  相似文献   

3.
Optimization principles for convective heat transfer   总被引:3,自引:0,他引:3  
Qun Chen  Moran Wang  Ning Pan  Zeng-Yuan Guo 《Energy》2009,34(9):1199-1206
Optimization for convective heat transfer plays a significant role in energy saving and high-efficiency utilizing. We compared two optimization principles for convective heat transfer, the minimum entropy generation principle and the entransy dissipation extremum principle, and analyzed their physical implications and applicability. We derived the optimization equation for each optimization principle. The theoretical analysis indicates that both principles can be used to optimize convective heat-transfer process, subject to different objectives of optimization. The minimum entropy generation principle, originally derived from the heat engine cycle process, optimizes the convective heat-transfer process with minimum usable energy dissipation focusing on the heat–work conversion. The entransy dissipation extremum principle however, originally for pure heat conduction process, optimizes the heat-transfer process with minimum heat-transfer ability dissipation, and therefore is more suitable for optimization of the processes not involving heat–work conversion. To validate the theoretical results, we simulated the convective heat-transfer process in a two-dimensional foursquare cavity with a uniform heat source and different temperature boundaries. Under the same constraints, the results indicate that the minimum entropy production principle leads to the highest heat–work conversion while the entransy dissipation extremum principle yields the maximum convective heat-transfer efficiency.  相似文献   

4.
为了比较平面螺旋折流板换热器和折面螺旋折流板换热器的传热和阻力性能,应用了换热器常用评价标准PEC准则和火积理论对两种换热器实验结果进行了分析,同时采用火积耗散极值原理对两种换热器的传热火积耗散率、阻力火积耗散率以及总火积耗散率进行了对比。结果表明:火积耗散理论分析换热器性能的结果与传统换热器评价标准PEC准则相符,说明了火积耗散理论的可靠性;折面螺旋折流板换热器的综合性能得到了有效的改进,火积耗散率也均优于原始结构,表明折面螺旋折流板换热器的性能得到较大改善;两种换热器传热火积耗散率值要远远大于阻力火积耗散率,约为阻力火积耗散率的一千余倍,说明传热损失为换热器的主要不可逆损失。  相似文献   

5.
Based on theories of thermodynamics, the energy equation in terms of entransy in heat transfer process is introduced, which not only describes the change of entransy, but also defines the entransy consumption rate. According to the regularity of entransy change in heat transfer process and the effect of entransy consumption rate on the irreversibility of heat transfer process, it can be found that entransy is a state variable, from which a new expression for the second law of thermodynamics is presented. Then by setting entransy consumption rate and power consumption rate as optimization objective and constraint condition for each other, the Lagrange conditional extremum principle is used to deduce momentum equation, constraint equation and boundary condition for optimizing flow field of convective heat transfer, which are applied to simulate convective heat transfer coupling with energy equation in an enclosed cavity. Through the numerical simulation, the optimized flow field under different constraint conditions is obtained, which shows that the principle of minimum entransy consumption is more suitable than the principle of minimum entropy generation for optimizing convective heat transfer process.  相似文献   

6.
Qun Chen  Yun-Chao Xu 《Energy》2012,37(1):571-579
The recently developed entransy theory is introduced in this paper to tackle the heat transfer processes in building central chilled water systems so as to improve their energy efficiency. We first divide the irreversible heat transfer processes into four categories: (1) air mixing processes; (2) heat transfer processes between chilled water and air; (3) chilled water mixing processes; and (4) heat transfer processes between chilled water and refrigerant. The formulas of entransy dissipation rates for each irreversible process are derived, and then the total entransy dissipation rate in the whole chilled water systems is obtained, which connects the geometrical structures of each heat exchanger and the operating parameters of each fluid directly to the demands of users and the supply of refrigerating unit. Based on the formula of entransy dissipation rate together with the conditional extremum method in mathematics, two optimization equation groups are deduced theoretically. Simultaneously solving such equation groups will easily find the optimal central chilled water system with the highest energy efficiency. Finally, a simple building central chilled water system with two users is taken as an example to illustrate the applications of the newly proposed optimization principle.  相似文献   

7.
Field synergy equation for turbulent heat transfer and its application   总被引:1,自引:0,他引:1  
A field synergy equation with a set of specified constraints for turbulent heat transfer developed based on the extremum entransy dissipation principle can be used to increase the field synergy between the time-averaged velocity and time-averaged temperature gradient fields over the entire fluid flow domain to optimize the heat transfer in turbulent flow. The solution of the field synergy equation gives the optimal flow field having the best field synergy for a given decrement of the mean kinetic energy, which maximizes the heat transfer. As an example, the field synergy analysis for turbulent heat transfer between parallel plates is presented. The analysis shows that a velocity field with small eddies near the boundary effectively enhances the heat transfer in turbulent flow especially when the eddy height which are perpendicular to the primary flow direction, are about half of the turbulent flow transition layer thickness. With the guide of this optimal velocity field, appropriate internal fins can be attached to the parallel plates to produce a velocity field close to the optimal one, so as to increase the field synergy and optimize the turbulent heat transfer.  相似文献   

8.
The heat transfer and fluid flow characteristics of a new type of fin with built-in interrupted delta winglets is studied in this paper by three-dimensional numerical simulation. In order to ensure reliability of numerical model, plate fin with common-flow-up delta winglets is firstly simulated. The comparison of numerical and experimental results shows a maximum deviation of 11.4% within the entire range of Reynolds number. The computational results show that heat transfer capacity and overall performance increase by 35–60% and 19–64%, respectively. The flow field visualization shows that the interrupted delta winglets can produce longitudinal vortices at the rear of delta winglets and reduce the wake zone behind the tube, so the proposed fin can enhance heat transfer accompanied by low pressure loss. The field synergy theory and entransy dissipation extremum principle are employed on analyzing the mechanism of heat transfer enhancement. The results indicate that enhancement heat transfer mechanism of interrupted delta winglets can be explained as the result of the decrease of synergy angle and reduction of the entransy dissipation.  相似文献   

9.
Mingtian Xu 《Energy》2011,36(7):4272-4277
In the present work, the entransy and entransy dissipation are defined from the thermodynamic point of view. It is shown that the entransy is a state variable and can be employed to describe the second law of thermodynamics. For heat conduction, a principle of minimum entransy dissipation is established based on the second law of thermodynamics in terms of entransy dissipation, which leads to the governing equation of the steady Fourier heat conduction without heat source. Furthermore, we derive the expressions of the entransy dissipation in duct flows and heat exchangers from the second law of thermodynamics, which paves the way for applications of the entransy dissipation theory in heat exchanger design.  相似文献   

10.
Application of entransy dissipation theory in heat convection   总被引:2,自引:0,他引:2  
In the present work, formulas for calculating the rates of the local thermodynamic entransy dissipation in convective heat transfer in general, and the internal and external flows in particular, are established. Practically, these results may facilitate the application of entransy dissipation theory in thermal engineering. Theoretically they shed light on solving the contradiction of the minimum entropy production principle with balance equations in continuum mechanics.  相似文献   

11.
In the present work, formulas for calculating the rates of the local thermodynamic entransy dissipation in convective heat transfer in general, and the internal and external flows in particular, are established. Practically, these results may facilitate the application of entransy dissipation theory in thermal engineering. Theoretically they shed light on solving the contradiction of the minimum entropy production principle with balance equations in continuum mechanics.  相似文献   

12.
以质量积耗散率最小为优化目标,对恒截面高渗透率通道的矩形单元体传质构形问题进行了分析和优化,得到结构体内平均传质效果最好的结构外形。结果表明:对于单元体和各级构造体,其平均传质压差均为最大传质压差的2/3。因为高渗透率材料中质流率密度符合线性分布,所以基于积耗散率最小与最大压差最小的最优构形完全一致。所得最优构形同时使得传质能力和传质安全性最好。  相似文献   

13.
本文基于最小火积耗散热阻原理,在考虑相变材料导热热阻以及非稳态传热过程的基础上,对多级套管式相变蓄热系统的融化温度进行了数值优化,获得了最优融化温度分布。在此基础上,研究了相变材料导热系数和传热管长度对最优融化温度、火积耗散热阻和平均蓄热速率的影响。研究结果表明,与现有理论优化方法相比,本文提出的数值优化方法具有更好的适用性;优化后多级套管式相变蓄热系统可有效提高相变蓄热系统的平均蓄热速率,降低火积耗散热阻;随着相变材料导热系数增大和传热管长度增加,多级套管式相变蓄热系统最优融化温度的温差愈加明显,其强化传热性能呈上升趋势。  相似文献   

14.
Using the analogy between heat and mass transfer processes, the recently developed entransy theory is extended in this paper to tackle the coupled heat and mass transfer processes so as to analyze and optimize the performance of evaporative cooling systems. We first introduce a few new concepts including the moisture entransy, moisture entransy dissipation, and the thermal resistance in terms of the moisture entransy dissipation. Thereinafter, the moisture entransy is employed to describe the endothermic ability of a moist air. The moisture entransy dissipation on the other hand is used to measure the loss of the endothermic ability, i.e. the irreversibility, in the coupled heat and mass transfer processes – this total loss is shown to consist of three parts: (1) the sensible heat entransy dissipation, (2) the latent heat entransy dissipation, and (3) the entransy dissipation induced by a temperature potential. Finally the new thermal resistance, defined as the moisture entransy dissipation rate divided by the squared refrigerating effect output rate, is recommended as an index to effectively reflect the performance of the evaporative cooling system. In the end, two typical evaporative cooling processes are analyzed to illustrate the applications of the proposed concepts.  相似文献   

15.
A crossflow heat exchanger (CFHEx) is designed and fabricated in a workshop. For designing this heat exchanger (HEx), the number of passes, frontal areas, HEx volumes, heat transfer areas, free-flow areas, ratios of minimum free-flow area to frontal area, densities, mass flow rates of flowing fluids, maximum/minimum heat capacities, heat capacity ratio, outlet temperatures of hot/cold fluids, average temperatures, mass velocities, Reynolds numbers, and convective heat transfer coefficients are evaluated by considering Colburn/friction factors. After fabrication of the HEx, effectiveness, exergy destruction, entransy dissipation, entransy dissipation-based thermal resistance, entransy dissipation number, and entransy effectiveness for hot/cold fluids sides are found at different flow rates and inlet temperatures of fluids. By experimental results, optimum operating conditions are found, which gives maximum effectiveness and entransy effectiveness but minimum rates of exergy destruction, entransy dissipation, entransy dissipation-based thermal resistance, and entransy dissipation number for the fabricated CFHEx. This study is concluded as follows: minimum exergy destruction and entransy dissipation rates (ie, 3.061 kJ/s·K and 1125.44 kJ·K/s, respectively) are found during experiment 2. Maximum entransy effectiveness of hot/cold fluids (ie, 0.689/0.21) is achieved in experiment 1. Moderate values of entransy dissipation number (ie, 4.689), entransy dissipation-based thermal resistance (ie, 0.04 s·K/J), exergy destruction (ie, 3.845 kJ/s·K), and entransy dissipation (ie, 1374.04 kJ·K/s) rates are found during experiment 1. Maximum effectiveness (ie, 0.4) for the fabricated HEx is also obtained through experiment 1. After comparative analyses, it is found that experiment 1 provides optimum results, which shows the best performance of the fabricated HEx.  相似文献   

16.
Disc cooling problem is optimized by taking entransy dissipation rate minimization as optimization objective. The non-dimensional mean temperature difference of the disc cooling model with radial high conducting fins inserted is deduced. The effects of the fin geometry, the fin aspect ratio, the ratio between the high conductivity and low conductivity, the relative amount of high conductivity material and the number of high conducting fins on the entransy dissipation rate of disc cooling are analyzed. The optimization results show that the high conducting fin should be extended to the centre of circle as the heat transfer effect of the high conducting fins is improved, and there exists an optimal fin aspect ratio corresponding to minimum entransy dissipation rate for different high conducting effects of the fin, and the number of high conducting fins has a slight effect on the entransy dissipation rate. Comparison with those for maximum temperature difference minimization shows that the constructs based on entransy dissipation rate minimization are different from those based on maximum temperature difference minimization, but the optimal constructal shape changing potentials of the number of fins and the relative amount of high conductivity material are similar.  相似文献   

17.
The field synergy principle has been validated to be an effective tool for enhancing convective heat transfer capability. Since convective mass transfer is analogous to convective heat transfer, the field synergy principle has been extended to convective mass transfer analyses to enhance the overall decontamination rate of indoor ventilation systems. According to the field synergy principle, the overall decontamination capability and the utilization efficiency of the air are both influenced by the synergy between the velocity vectors and the contaminant concentration gradients. Furthermore, in order to derive a method to improve the synergy based on the essence of convective mass transfer, the mass transfer potential capacity dissipation function is defined, and then the convective mass transfer field synergy equation is obtained by seeking the extremum of the mass transfer potential capacity dissipation function for a set of specified constraints. The convective mass transfer field synergy equation can be solved to find the optimized air velocity distribution to increase the field synergy and the overall decontamination capability. The optimized air velocity field provides guidance for optimizing ventilation system designs.  相似文献   

18.
Qun Chen  Ning Pan  Zeng-Yuan Guo 《Energy》2011,36(5):2890-2898
After introducing the concepts of moisture entransy, moisture entransy dissipation and thermal resistance based on moisture entransy dissipation (TRMED) in part I of this study, we further analyze several direct/indirect evaporative cooling processes based on the above concepts in this part. The nature of moisture entransy, moisture entransy dissipation and TRMED during evaporative cooling processes was reexamined. The results demonstrate that it is the moisture entransy, not the enthalpy, that represents the endothermic ability of a moist air, and reducing the entransy dissipation by both enlarging the thermal conductance of heat and mass transfer, and decreasing the temperature potential of the moist air, i.e. the difference between the dry-bulb temperature of moist air over its dew-point temperature, will result in a smaller system TRMED, and consequently a better evaporative cooling performance. Then, a minimum thermal resistance law for optimizing evaporative cooling systems is developed. For given mass flow rates of both moist air and water, with prescribed moist air and water conditions, minimizing the TRMED will actually lead to the most efficient evaporative cooling performance. Finally, the thermal conductance allocation for an indirect evaporative cooling system is optimized to illustrate the application of the proposed minimum thermal resistance law.  相似文献   

19.
20.
建立了新型板式省煤器的传热模型,计算了新型板式省煤器的火积耗散热阻以及空气侧压降,分析了新型板式省煤器结构参数及空气流速变化时,火积耗散热阻及空气侧压降的变化情况。研究结果表明:增大长轴可以减小火积耗散热阻,有利于提高板式省煤器的传热性能,并且空气侧压降变化幅度不大;增大短轴可以减小火积耗散热阻,有利于提高板式省煤器的传热性能,但空气侧压降增大;减小板束间距可以减小火积耗散热阻,有利于提高板式省煤器的传热性能,但空气侧压降增大,尤其是在板束间距小于20 mm时,继续减小板束间距会造成空气侧压降急剧增大;增大空气进口流速可以减小火积耗散热阻,有利于提高板式省煤器的传热性能,但空气侧压降增大,对换热器的磨损也会增加。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号