共查询到20条相似文献,搜索用时 78 毫秒
1.
2.
3.
本文提出一种再现标准高色温光源的新方案,并以标准照明体D_(65)的复现为例讨论了该方案的特点和复现效果。 相似文献
4.
5.
6.
7.
8.
本文介绍了小角度检查仪复现标准角度时不确定度的来源及大小 ,由于小角度检查仪没有仪器示值误差这项技术指标 ,因此对其复现标准角度的不确定度进行评定显得尤为重要。 相似文献
9.
10.
按照ISO/16063-11:1999《激光干涉绝对法振动校准》所述,激光干涉振动一次绝对校准方法主要有条纹计数法、最小点法与正弦逼近法三种,其复现频率范围为1Hz~10kHz.而德国联邦物理技术研究院(PTB)现已建立和保存的低频、中频、高频振动激光干涉一次绝对校准标准的复现频率范围则达0.1Hz~20kHz.此外,PTB还实现了旋转运动物理量值--角加速度的复现;其复现频率范围也达到0.3Hz~1kHz.作为曾在PTB1.22实验室进行过研究工作的访问学者,作者旨在通过对PTB所建激光干涉振动一次绝对校准标准的 相似文献
11.
A quasi-convex reproducing kernel approximation is presented for Galerkin meshfree analysis. In the proposed meshfree scheme, the monomial reproducing conditions are relaxed to maximizing the positivity of the meshfree shape functions and the resulting shape functions are referred as the quasi-convex reproducing kernel shape functions. These quasi-convex meshfree shape functions are still established within the framework of the classical reproducing or consistency conditions, namely the shape functions have similar form as that of the conventional reproducing kernel shape functions. Thus this approach can be conveniently implemented in the standard reproducing kernel meshfree formulation without an overmuch increase of computational effort. Meanwhile, the present formulation enables a straightforward construction of arbitrary higher order shape functions. It is shown that the proposed method yields nearly positive shape functions in the interior problem domain, while in the boundary region the negative effect of the shape functions are also reduced compared with the original meshfree shape functions. Subsequently a Galerkin meshfree analysis is carried out by employing the proposed quasi-convex reproducing kernel shape functions. Numerical results reveal that the proposed method has more favorable accuracy than the conventional reproducing kernel meshfree method, especially for structural vibration analysis. 相似文献
12.
K. Yu. Sakharov O. V. Mikheev V. A. Turkin A. V. Sukhov A. I. Aleshko 《Measurement Techniques》2010,53(7):820-823
A method of reproducing the units of pulsed electric and magnetic field strength in a standard system with a pulse rise time
of less than 20 psec, constructed using a “cone over a plane” field-generating system is considered. The components of the
uncertainty in reproducing the units are analyzed. The extended uncertainty is not greater than 6.5%. 相似文献
13.
14.
É. G. Aslanyan M. V. Balakhanov N. S. Gusyatinskaya A. S. Doinikov V. I. Kozlov N. A. Safarov V. R. Shlegel' 《Measurement Techniques》2002,45(3):223-227
The results are given of metrological investigations of a new State primary standard GÉT 161-01 for the hardness of metals on the Shore D scale. The standard is intended for reproducing and transferring the Shore D scale in the range 20-140 HSD. 相似文献
15.
The metrological investigation of the new measurement standard complex is described. The primary standard is used for reproducing and transmitting the unit of electric field strength to secondary standards and measuring instruments.Translated from Izmeritel'naya Tekhnika. No. 1, pp. 4–7, January, 1995. 相似文献
16.
I. N. Krotkov 《Measurement Techniques》1972,15(10):1446-1452
Conclusions The standard of the henry is the first (with respect to its approval) state standard in the range of inductance, capacitance, and resistance measurements.This standard served up to the beginning of the sixties as the only initial (computed) quantity, on whose basis the VNIIM determined by indirect means the absolute values of the units of capacitance and resistance. The error of these indirect methods for reproducing units was of the order of 10–5.Investigations, including circulatory international comparisons, of working standards have shown that the precision and accuracy of reproducing inductance units in the USSR are at the level of the best results obtained in national metrological institutes.In recent years new, more precise methods for reproducing resistance units have appeared. These methods, as well as the application of new types of measuring equipment, made it possible to extend substantially the nominal values' range of inductance standards covered by the test schematic.In order to ensure uniformity in this field of measurements, it is necessary to have a set of mutually-related computed inductance and capacitance standards (Fig. 3).The State Committee of standards attached to the USSR Council of Ministers approved, in accordance with the VNIIM recommendations, the coil types PB-1, KB-1, KB-2, and KB-3 as primary state standards of the henry. Prof. Igor' Nikolaevich Krotkov,head of the VNIIM laboratory,was appointed scientific keeper of this State standard.Translated from Izmeritel'naya Tekhnika, No. 10, pp. 7–11, October, 1972. 相似文献
17.
Volobuev V. S. Klokova N. P. Kosov L. I. Kamkova V. D. Minakov V. P. Tikhomirov V. I. 《Measurement Techniques》2000,43(12):1052-1056
A standard stand has been developed to normalize the metrological characteristics of resistance strain gages and certify them. The stand consists of a unit for reproducing strains and an automated system for measuring, analyzing, and recording data. 相似文献
18.
Summary The specified permissible error of industrial optical pyrometers must be determined as the sum the absolute values of the limiting manufacturing error of the instrument and twice the root mean square value of the error due to inaccuracies in reproducing the International Temperature Scale by means of a standard radiator used for calibration. 相似文献
19.
A. V. Gorbatikov A. A. Il'inskii E. P. Krivtsov O. V. Pavlenko A. P. Yakovlev 《Measurement Techniques》1993,36(8):899-902
A set of standard equipments is considered for reproducing seismic oscillation parameters that have been developed at the Mendeleev All-Union Metrology Research Institute.Translated from Izmeritel'naya Tekhnika, No. 8, pp. 36–38, August, 1993. 相似文献
20.
Conclusion The perfection of the complex of measuring means that are presently a state primary standard of the farad of the USSR have as their purpose a further decrease in the error of reproducing the farad, which must be decreased and brought to between 1·10–7 and 2·10–7. An important role, namely the perfection of indirect methods and an increase in the precision of reproducing still other electromagnetic units, was assigned to the primary standard of the unit of capacitance in the course of perfecting the system of standards of units of electrical magnitudes [4], These units include resistance, inductance, magnetic flux, and magnetic induction, whose reproduction error in the new system of standards will be decreased to between one-third and one-half.Translated from Izmeritel'naya Tekhnika, No. 4, pp. 76–78, April, 1976. 相似文献