首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
PURPOSE: To describe the clinical, neurodiagnostic, and MR findings in seven children with brain stem and spinal multiple sclerosis. METHODS: Spinal or brain stem multiple sclerosis was diagnosed in seven children between 1986 and 1992. All patients had neurologic and MR examinations as well as neurodiagnostic testing, including spinal fluid analysis and brain stem and auditory evoked potentials. RESULTS: Three children had clinical findings and masslike lesions in the brain stem (two) or spinal cord (one) suggestive of neoplasm, which prompted biopsy (two) or radiation therapy (one). Five of six patients with spinal involvement had cord swelling with increased signal on T2-weighted images over at least three cord segments, and two children had essentially holocord involvement. Three children had normal cranial MR at presentation. CONCLUSIONS: Multiple sclerosis involvement of the brain stem and spinal cord may be associated with extensive swelling and MR signal changes suggestive of neoplasm without typical cerebral white matter abnormalities. Serial clinical and neuroimaging examinations may be necessary to make a definitive diagnosis of multiple sclerosis in children.  相似文献   

3.
A series of 8 patients each with an excessively long ulnar styloid that was impacting the triquetrum, causing chondromalacia, synovitis, and pain, is presented. Four patients developed symptoms as a result of an injury and 4 had no definable acute precipitating injury. The average age at the time of surgery was 34 years. There were 3 male and 5 female patients. The average follow-up period was 34 months. All patients were treated by open partial ulnar styloidectomy. Outcome was evaluated clinically and by means of patient questionnaire and radiographs. Pain decreased from a preoperative average score of 3.5 to a postoperative average score of 1.3, which equates to mild pain requiring no medication. All but 1 patient returned to their previous employment unrestricted. The average preoperative ulnar styloid length was 7.4 mm and the average ulnar styloid process index was 0.41, which is almost twice normal. There were no complications. It is likely that an excessively long ulnar styloid has important implications for the kinematics of the lunatotriquetral interval. Details of the diagnosis of this condition, including a new provocative test, and operative management are discussed.  相似文献   

4.
PURPOSE: To characterize plaques of multiple sclerosis (MS) using both proton MR spectroscopy and magnetization transfer (MT) imaging. METHODS: The magnetization transfer ratio (MTR) was calculated from two series of three-dimensional gradient-recalled acquisition in the steady state (GRASS) images obtained with and without an MT saturation pulse. Proton spectra were acquired using the point-resolved spectroscopy (PRESS) sequence with a voxel size of 1.5 x 1.5 x 1.5 cm3. A total of 28 spectra were obtained in 13 patients who had clinically definitive MS. The spectra were analyzed together with the MTR. RESULTS: A positive relationship was found between the N-acetylaspartate (NAA)/creatine (Cr) ratio and the MTR in MS plaques, whereas no significant correlation was found between the metabolite ratios and the signal intensity on fast spin-echo T2-weighted MR images. CONCLUSION: Small changes in the MTR of MS plaques relative to the MTR of normal white matter may reflect inflammatory changes and edema, whereas larger changes in MTR correlate with decreased NAA/Cr ratio and therefore suggest demyelination and irreversible damage from chronic MS plaques.  相似文献   

5.
OBJECTIVE: The purposes of this study were to determine the frequency of discordant MR findings of the anterior cruciate ligament (ACL) using sagittal-oblique images and the arthroscopic integrity of the ACL in knees with a discordant MR appearance. MATERIALS AND METHODS: The frequency of discordant MR features was determined by independently reviewing the sagittal-oblique images of 53 consecutive patients undergoing subsequent arthroscopic surgery. The first 25 consecutive knees were examined using a conventional, dual-echo, T2-weighted spin-echo (SE) sequence; the subsequent 28 consecutive knees were examined using both a T1-weighted SE(T1) and a fat-suppressed, fast spin-echo (FSE) T2-weighted sequence. Two examiners who were unaware of patient identification and arthroscopic results evaluated only the sagittal images that included the ACL. Each reviewer graded the ACL as torn or intact. The MR appearance was considered discordant when one MR sequence showed disrupted or poorly seen ACL fibers and the other sequence showed intact ACL fibers. The arthroscopic integrity of the ACL was determined for the 20 knees with a discordant MR appearance. RESULTS: A discordant MR appearance of the ACL was seen in 20 of the 53 knees (38%), including 10 knees evaluated using conventional T2-weighted sequences (40%) and 10 knees using T1/FSE T2 (36%) sequences. Arthroscopic examination of these knees showed intact ACL fibers in all 20 knees; the ACL was normal in 18 knees and a partial tear was questioned in two knees. CONCLUSION: A discordant appearance of the ACL was frequently encountered (38%) using either conventional T2-weighted sequences or T1 and FSE MR sequences in the sagittal-oblique plane. Intact ACL fibers were found during arthroscopy in all 20 knees with a discordant MR appearance.  相似文献   

6.
The current state-of-the-art imaging technique in multiple sclerosis (MS) is magnetic resonance (MR) imaging. With improved imaging technology, MR spectroscopy offers the capacity to identify those chemical changes associated with MS and promises to enhance our ability to understand this disease. Physiologic function in the central nervous system can be measured using evoked potentials. This article analyzes the correlation between these two techniques.  相似文献   

7.
Interactions between the hypothalamic-pituitary-adrenocortical (HPA) system and melatonin secretion have been demonstrated, but only the effects of melatonin on the activity of the HPA system have been studied in man. Alterations of melatonin secretion described as low-melatonin syndrome have been demonstrated in patients suffering from a major depressive episode, and an inhibitory factor on melatonin secretion has been postulated. We investigated whether corticotropin-releasing hormone (CRH), which is thought to be involved in HPA abnormalities in depressed patients, can also suppress melatonin secretion in healthy volunteers. Ten healthy male human volunteers in a double-blind study design received randomized hourly intravenous injections from 08.00 to 18.00 h that contained 10 micrograms human CRH, 1 microgram adrenocorticotropic hormone (ACTH), or placebo to simulate pulsatile hormone secretion. Plasma melatonin and cortisol responses during the treatment and nocturnal sleep electroencephalograms after the treatment were recorded. Administration of CRH reduced melatonin secretion significantly below values obtained after administration of placebo and ACTH. Cortisol secretion was significantly enhanced by ACTH in comparison to both placebo and CRH. Electroencephalographic sleep parameters revealed no treatment effects. Our findings suggest that CRH has an inhibitory effect on the pineal secretion of melatonin in normal man. A mechanism via a release of cortisol was not supported by our results. Secondary hormonal effects from changes in nocturnal sleep architecture were excluded. Further investigation of the action of CRH on melatonin secretion as well as the mutual feedback between the HPA system and the pineal gland may extend our knowledge of neuroendocrine alterations mediating the adaptive response to stress and the eventual involvement in the pathogenesis of depression.  相似文献   

8.
PURPOSE: To compare qualitative and quantitative magnetic resonance (MR) mammographic features of breast lesions with histopathologic findings, especially tumor angiogenesis. MATERIALS AND METHODS: Seventy-three patients (72 women, one man; aged 30-78 years; mean age, 51.0 years) with suspicious breast lesions underwent MR imaging. Noncontrast medium-enhanced localization imaging and then gadolinium-enhanced dynamic fast spoiled gradient-recalled-echo (SPGR) imaging were performed in all patients. In selected patients, subtraction fast SPGR images were obtained. The Pearson and Spearman correlation tests were used to determine the strength of the relationships between enhancement parameters and microvessel determinations. RESULTS: Time intensity curve type correlated with microvessel density grade (Spearman rank correlation test: r = .90, P < .001). The steepest slope of contrast medium uptake correlated with microvessel counts (Pearson correlation test; r = .83, P < .001). Peripheral enhancement in invasive carcinomas (n = 9) correlated with high peripheral and low central microvessel densities, which were associated with desmoplasia and/or necrosis. Internal septations (n = 2) were seen only in fibroadenomas. CONCLUSION: The density and distribution of microvessels may play major roles in the determination of the initial rate of contrast medium uptake and the heterogeneity of tumor enhancement.  相似文献   

9.
Multiple sclerosis (MS) is believed to impose a severely deleterious emotional impact on patients and their families. A review of the recent research literature indicates that few controlled investigations have been done to support the assumption. Recent data have indicated that two factors—functional loss (imposed by the increased physical disability produced by MS) and disease activity (exacerbation and progression of symptoms)—have been identified as contributors to increased emotional distress in MS patients. However, theoretical formulations concerning the specific mechanisms by which these or other potential determinants may produce emotional distress appear, largely, to have been ignored. Thus, this article identifies a number of fundamental conceptual and methodological issues. Potential solutions for the problems that they introduce are suggested, and a provisional model of the mechanisms involved is offered. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

10.
PURPOSE: To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS: Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite multiple sclerosis. The images in each sequence were evaluated by two raters and consensus was reached by agreement. RESULTS: In comparing conventional spin-echo with fast spin-echo sequences, five lesions were seen only by conventional spin-echo and 63 were seen only by fast spin-echo; in comparing conventional spin-echo with fast FLAIR sequences, 18 lesions were seen only by conventional spin-echo and 109 only by fast FLAIR; in comparing conventional spin-echo with turbo gradient spin-echo sequences, 51 lesions were seen only by conventional spin-echo and seven only by turbo gradient spin-echo; in comparing fast spin-echo with fast FLAIR sequences, 45 lesions were seen only by fast spin-echo and 52 only by fast FLAIR. CONCLUSION: Fast spin-echo and fast FLAIR sequences improve the sensitivity of MR imaging in the detection of multiple sclerosis lesions with reduced acquisition time as compared with conventional spin-echo sequences. These sequences should therefore be considered for serial studies in patients with multiple sclerosis. The sensitivity of turbo gradient spin-echo was inferior to the other sequences, but its reduced acquisition time could make this technique the ideal choice for patients who cannot tolerate longer examination times.  相似文献   

11.
The added technical complexity associated with the transfixion screws for interlocking nailing has introduced new complications. We present a case of a femoral arteriovenous fistula caused by the distal interlocking screw after intramedullary nailing of a comminuted diaphyseal femoral fracture.  相似文献   

12.
OBJECTIVE: This study correlated the extent of abnormalities detected by different magnetic resonance imaging (MRI) techniques [proton density (PD)-weighted, T1-weighted, and magnetization transfer imaging (MTI)] with the overall cognitive, frontal lobe, and memory impairments in patients with MS. PATIENTS: There were 30 clinically definite MS patients, with different disease courses. Exclusion criteria: psychoactive/steroid treatments, mood disorders, acute relapse phase. MAIN OUTCOME MEASURES: Neuropsychological test results. Total (TLL) and frontal (FLL) lesion loads assessed from PD-weighted, T1-weighted (22 patients), and MTI (22 patients) MRI scans. Average lesion MT ratios (MTR) and analysis of the MTR histograms from brain tissue axial slabs on MTI scans. RESULTS: Patients with frontal lobe deficits (n=15) or memory impairment (n-17) had a higher TLL on PD scans (p=0.04 and p=0.01, respectively). Patients with frontal lobe deficits had higher FLL on PD scans (p=0.01) and TLL on MTI (p=0.03) scans. No significant relationships between the extent of T1-weighted lesion loads and the presence of any neuropsychological impairment. Mean MTR of both MS lesions and whole brain tissue was lower in patients with frontal lobe impairment (p=0.04). MRI lesion loads correlated significantly with some neuropsychological test scores. CONCLUSIONS: Lesion loads on PD-weighted MRI and MTI-derived measures are associated with cognitive decline in MS patients. Overall macroscopic and microscopic brain damage is more important than the corresponding regional brain disease in determining deficits of selective cognitive domains.  相似文献   

13.
Multiple sclerosis (MS) is a chronic inflammatory disease of the central nervous system which leads to destruction of myelin sheaths. The patterns of cell proliferation in the early course of the disease are largely unknown. The present study used immunohistochemical identification of proliferating glial cells in stereotactic brain biopsy material of eight patients with early chronic MS. Double-labelling with the proliferation marker MIB-1 detected proliferating oligodendrocytes (MOG), astrocytes (GFAP) and microglia/macrophages (Ki-M1P). The majority of proliferating cells were macrophages/microglia when compared with oligodendrocytes (P > 0.005) or astrocytes (P > 0.0005); only a minor proportion of microglia/macrophages, however, proliferated in situ. Astrocytic and oligodendroglial proliferation was sparse to absent and showed significant variations between different patients. There were statistically significant differences when comparing the amount of proliferation between lesions of different demyelinating activity: highest numbers of proliferating cells were found in early active lesions compared with demyelinated and early remyelinated lesions (P > 0.05) or the periplaque white matter (P > 0.01). MOG-positive oligodendrocytes proliferated occasionally in the early stages of lesion formation; this proliferation occurred in four cases but was independent of the stage of the disease. Since MOG is expressed by mature oligodendrocytes, and not by immature precursors, this might suggest a potential role for the proliferation of mature surviving oligodendrocytes with subsequent remyelination.  相似文献   

14.
OBJECTIVE: The goal of our study was to compare a T2-weighted breath-hold fast spin-echo (BHSE) technique with T2-weighted non-breath-hold fast spin-echo techniques for imaging the liver. SUBJECTS AND METHODS: Thirty-three patients with hepatic lesions had T2-weighted BHSE images obtained in 22 sec and conventional T2-weighted non-breath-hold fast spin-echo images obtained in 3 min 12 sec with and without fat suppression. Images were analyzed quantitatively by measuring the lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios of lesions and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and presence of artifacts. RESULTS: Quantitatively, lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios obtained with the BHSE technique were inferior to those obtained with fast spin-echo techniques with and without fat suppression (11.2 +/- 7.1 versus 15.4 +/- 10.6 and 14.5 +/- 9.8, p < .001; 5.3 +/- 3.7 versus 8.7 +/- 3.5 and 7.0 +/- 3.8, p < .001; 16.2 +/- 8.2 versus 20.1 +/- 10.9 and 19.7 +/- 9.5, p < .01, respectively; Student's t test). Qualitatively, image artifacts and intrahepatic vessel depiction on BHSE images were similar to those obtained with the fast spin-echo techniques. The BHSE technique was superior to fat-suppressed fast spin-echo technique for showing hepatic contours (p < .01; Wilcoxon signed-rank test). CONCLUSION: The BHSE technique is quantitatively inferior to non-breath-hold fast spin-echo techniques. However, further studies with a surgical standard of reference are needed to compare the three techniques in terms of sensitivity.  相似文献   

15.
16.
BACKGROUND AND PURPOSES: New strategies have been developed to improve the sensitivity of contrast-enhanced MR imaging in quantifying disease activity in patients with multiple sclerosis (MS). The goal of the present study was to evaluate the sensitivity of T1-weighted images after injection of a triple dose of contrast material and application of a magnetization transfer (MT) pulse in the detection of enhancing lesions as compared with the conventional approach. METHODS: Monthly MR images were obtained in 13 patients with relapsing-remitting MS for a period of 3 months. The MR studies were performed on two separate occasions with single- and triple-dose contrast material. In each session, T1- and T2-weighted spin-echo images with and without the MT pulse were obtained before and after contrast administration. All images were evaluated in a blinded fashion and scored in random order and consensually by two readers. The number of total and new enhancing lesions and active images was counted. RESULTS: Eighty-six percent more enhancing lesions and 54% more new enhancing lesions were detected with triple-dose as compared with single-dose non-MT sequences, whereas single-dose MT images depicted 33% more enhancing lesions and 18% more new enhancing lesions than the single-dose non-MT images. Twenty-nine percent more lesions were detected on triple-dose non-MT images than on single-dose MT images. The combination of a triple dose of contrast material and MT did not produce any significant change in detection of enhancing lesions as compared with a triple dose of contrast without MT. CONCLUSION: The use of a triple dose of contrast material is the best approach to maximize the sensitivity of enhanced MR imaging.  相似文献   

17.
18.
19.
OBJECTIVE: Our objective was to compare the sensitivity of non-breath-hold T2-weighted fast spin-echo with and without fat suppression, breath-hold T2-weighted fast spin-echo without fat suppression, and spoiled gradient-recalled echo (GRE) MR imaging for detecting hepatic tumors using surgical findings as the standard of reference. SUBJECTS AND METHODS: Eighteen patients with 36 surgically proven hepatic tumors had non-breath-hold T2-weighted fast spin-echo (6000/117 [TR/effective TE; echo train length, 16) MR imaging with and without fat suppression, breath-hold T2-weighted fast spin-echo MR imaging (2700/105; echo train length, 20), and spoiled GRE images (10.1/1.9; flip angle, 30 degrees) obtained before and after injection of a gadolinium chelate. Images were analyzed separately by two independent readers, with disagreements resolved by consensus reading. RESULTS: Non-breath-hold T2-weighted fast spin-echo MR imaging with and without fat suppression depicted 22 (61%; 95% confidence interval [CI], 43-77%) and 20 (56%; 95% CI, 37-72%) of 36 hepatic tumors, respectively. Breath-hold T2-weighted fast spin-echo imaging allowed detection of 19 (53%; 95% CI, 35-69%) of 36 hepatic tumors. Unenhanced and gadolinium chelate-enhanced spoiled GRE images allowed depiction of 18 (50%; 95% CI, 33-67%) and 29 (81%; 95% CI, 63-91%) of 36 hepatic tumors, respectively. Gadolinium chelate-enhanced spoiled GRE images allowed depiction of significantly more hepatic tumors than any of the other pulse sequences. CONCLUSION: Gadolinium chelate-enhanced spoiled GRE imaging is more sensitive than T2-weighted MR imaging obtained with a breath-hold or a non-breath-hold technique.  相似文献   

20.
OBJECTIVE: Aggressive angiomyxoma is a benign tumor affecting the pelvis and perineum, predominantly in women. Because of its variable presentation as a soft mass in the vulva, perianal region, buttock, or pelvis, the tumor is often clinically misdiagnosed and initial surgery is usually unsuccessful in extirpating it. This study describes the imaging features of these tumors. CONCLUSION: Aggressive angiomyxomas display unusual growth patterns of translevator extension with growth around perineal structures. Both CT and MR imaging show the transdiaphragmatic extent of these tumors. High signal intensity on T2-weighted MR images may reflect the myxomatous stroma of these tumors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号