首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wang S  Zhang X  Mao X  Zeng Q  Xu H  Lin Y  Chen W  Liu G 《Nanotechnology》2008,19(43):435501
We describe a lead sulfide nanoparticle (PbS NP)-based electrochemical immunoassay to detect a tumor biomarker, carcinoembryonic antigen (CEA). Cubic PbS NPs were prepared and functionalized with thioglycolic acid (TGA), which stabilized the formed NPs and offered carboxyl groups to conjugate with CEA antibodies. PbS NP conjugated with monoclonal CEA antibody was used as a label in an immunorecognition event. After a complete sandwich immunoreaction among the primary CEA antibody (immobilized on the carboxyl-modified magnetic beads), CEA and the PbS-labeled secondary antibody (PbS-anti-CEA), PbS labels were captured to the magnetic-bead (MB) surface through the antibody-antigen immunocomplex. Electrochemical stripping analysis of the captured PbS was used to quantify the concentration of CEA after an acid-dissolution step. The MBs and the magnetic separation platform were used to integrate a facile antibody immobilization with immunoreactions and the isolation of immunocomplexes from reaction solutions in the immunoassay. The voltammetric response is highly linear over the range of 1-50?ng?ml(-1) CEA, and the limit of detection is estimated to be 0.5?ng?ml(-1). The performance of this nanoparticle-based electrochemical immunoassay was successfully evaluated with human serum spiked with CEA, indicating that this convenient and sensitive technique offers great promise for rapid, simple and cost-effective analysis of tumor biomarkers in biological fluids.  相似文献   

2.
Liu G  Wang J  Wu H  Lin Y 《Analytical chemistry》2006,78(21):7417-7423
A versatile bioassay label based on marker-loaded apoferritin nanoparticles (MLANs) has been developed for sensitive protein detection. Dissociation and reconstitution characteristics at different pH as well as the special cavity structure of apoferritin provides a facile route to prepare nanoparticle labels and avoid the complicated and tedious synthesis process of conventional nanoparticle labels. The optical and electrochemical characteristics of the prepared nanoparticle labels are easily controlled by loading different optical or electrochemical markers. A fluorescence marker (fluorescein anion) and a redox marker [hexacyanoferrate(III)] were used as model markers to load into the cavity of apoferritin nanoparticles for microscopic fluorescence immunoassay and electrochemical immunoassay, respectively. Detection limits of 0.06 (0.39 pM) and 0.08 ng mL(-1) (0.52 pM) IgG were obtained with fluorescein MLAN and hexacyanoferrate MLANs, respectively. The new nanoparticle labels hold great promise for multiplex protein detection (in connection with nanoparticles loaded with different markers) and for enhancing the sensitivity of other bioassays.  相似文献   

3.
Liu G  Lin YY  Wang J  Wu H  Wai CM  Lin Y 《Analytical chemistry》2007,79(20):7644-7653
We describe a disposable electrochemical immunosensor diagnosis device that integrates the immunochromatographic strip technique with an electrochemical immunoassay and exploits quantum dot (QD, CdS@ZnS) as labels for amplifying signal output. The device takes advantage of the speed and low cost of the conventional immunochromatographic strip test and the high sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1-10 ng mL(-1) IgG, and the limit of detection is estimated to be 30 pg mL(-1) in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL(-1) using a 20-min immunoreaction time. The device has been successfully applied for the detection of prostate-specific antigen (PSA) in human serum sample with a detection limit of 20 pg mL(-1). The results were validated by using the commercial PSA enzyme-linked immunosorbent assay kit and showed high consistency. The new disposable electrochemical diagnosis device thus provides a rapid, clinically accurate, and quantitative tool for protein biomarker detection.  相似文献   

4.
Hybrid zinc nanoparticles were synthesized by adding thioglycolic acid (TGA) into a ZnO-particle synthesis procedure. Compared to the ZnO particles prepared without TGA, the hybrid nanoparticles are markedly different in their morphology, chemical composition, and growth kinetics. Moreover, they display colloidal stability and appropriate surface properties for bioconjugation. To demonstrate their biosensing application, the hybrid nanoparticles were conjugated and applied as biolabels or signal transducers in a sandwich immunoassay for mouse IgG. The immunoassay fluorescence signal was obtained by releasing zinc ions from these nanoparticle labels and further incubating the released zinc ions with zinc-sensitive fluorescence indicator Fluozin-3. The immunoassay presents a dynamic detection range from 10 pM to 1 nM.  相似文献   

5.
Electrochemical coding for multiplexed immunoassays of proteins   总被引:1,自引:0,他引:1  
Liu G  Wang J  Kim J  Jan MR  Collins GE 《Analytical chemistry》2004,76(23):7126-7130
An electrochemical immunoassay protocol for the simultaneous measurements of proteins, based on the use of different inorganic nanocrystal tracers is described. The multiprotein electrical detection capability is coupled to the amplification feature of electrochemical stripping transduction (to yield fmol detection limits) and with an efficient magnetic separation (to minimize nonspecific adsorption effects). The multianalyte electrical sandwich immunoassay involves a dual binding event, based on antibodies linked to the nanocrystal tags and magnetic beads. Carbamate linkage is used for conjugating the hydroxyl-terminated nanocrystals with the secondary antibodies. Each biorecognition event yields a distinct voltammetric peak, whose position and size reflects the identity and level, respectively, of the corresponding antigen. The concept is demonstrated for a simultaneous immunoassay of beta(2)-microglobulin, IgG, bovine serum albumin, and C-reactive protein in connection with ZnS, CdS, PbS, and CuS colloidal crystals, respectively. These nanocrystal labels exhibit similar sensitivity. Such electrochemical coding could be readily multiplexed and scaled up in multiwell microtiter plates to allow simultaneous parallel detection of numerous proteins or samples and is expected to open new opportunities for protein diagnostics and biosecurity.  相似文献   

6.
Ao L  Gao F  Pan B  He R  Cui D 《Analytical chemistry》2006,78(4):1104-1106
A unique, sensitive, and highly specific fluoroimmunoassay system for antigen detection using gold and magnetic nanoparticles has been developed. The assay is based on the fluorescence quenching of fluorescein isothiocyanate caused by gold nanoparticles coated with monoclonal antibody. To demonstrate its analytical capabilities, the magnetic nanoparticles were coated with anti-alpha-fetoprotein polyclonal antibodies, which specifically bound with alpha-fetoprotein. Gold nanoparticles coated with anti-alpha-fetoprotein monoclonal antibodies could sandwich the alpha-fetoprotein captured by the magnetic nanoparticle probes. The sandwich-type immunocomplex was formed on the surface of magnetic nanoparticles and could be separated by a magnetic field. The supernatant liquid, which contained the unbound gold nanoparticle probes, was used to quench the fluorescence, and the fluorescence intensity of fluorescein isothiocyanate at 516 nm was proportional to the alpha-fetoprotein concentration. The result showed that the limit of detection of alpha-fetoprotein was 0.17 nM. This new system can be extended to detect target molecules with matched antibodies and has broad potential applications in immunoassay and disease diagnosis.  相似文献   

7.
Double-codified gold nanolabels for enhanced immunoanalysis   总被引:7,自引:0,他引:7  
A novel double-codified nanolabel (DC-AuNP) based on gold nanoparticle (AuNP) modified with anti-human IgG peroxidase (HRP)-conjugated antibody is reported. It represents a simple assay that allows enhanced spectrophotometric and electrochemical detection of antigen human IgG as a model protein. The method takes advantage of two properties of the DC-AuNP label: first, the HRP label activity toward the OPD chromogen that can be related to the analyte concentration and measured spectrophotometrically; second, the intrinsic electrochemical properties of the gold nanoparticle labels that being proportional to the protein concentration can be directly quantified by stripping voltammetry. Beside these two main direct determinations of human IgG, a secondary indirect detection was also applicable to this system, exploiting the high molar absorptivity of gold colloids, by which, the color intensity of their solution was proportional to the concentration of the antigen used in the assay. Paramagnetic beads were used as supporting material to immobilize the sandwich-type immunocomplexes resulting in incubation and washing times shorter than those typically needed in classical ELISA tests by means of a rapid magnetic separation of the unbound components. A built-in magnet graphite-epoxy-composite electrode allowed a sensibly enhanced adsorption and electrochemical quantification of the specifically captured AuNPs. The used DC-AuNP label showed an excellent specificity/selectivity, as a matter of fact using a different antigen (goat IgG) a minimal nonspecific electrochemical or spectrophotometric signal was measured. The detection limits for this novel double-codified nanoparticle-based assay were 52 and 260 pg of human IgG/mL for the spectrophotometric (HRP-based) and electrochemical (AuNP-based) detections, respectively, much lower than those typically achieved by ELISA tests. The developed label and method is versatile, offers enhanced performances, and can be easily extended to other protein detection schemes as well as in DNA analysis.  相似文献   

8.
Wang J  Xu D  Kawde AN  Polsky R 《Analytical chemistry》2001,73(22):5576-5581
A new nanoparticle-based electrical detection of DNA hybridization, based on electrochemical stripping detection of the colloidal gold tag, is described. In this protocol, the hybridization of a target oligonucleotide to magnetic bead-linked oligonucleotide probes is followed by binding of the streptavidin-coated metal nanoparticles to the captured DNA, dissolution of the nanometer-sized gold tag, and potentiometric stripping measurements of the dissolved metal tag at single-use thick-film carbon electrodes. An advanced magnetic processing technique is used to isolate the DNA duplex and to provide low-volume mixing. The influence of relevant experimental variables, including the amounts of the gold nanoparticles and the magnetic beads, the duration of the hybridization and gold dissolution steps, and the parameters of the potentiometric stripping operation upon the hybridization signal, is examined and optimized. Transmission electron microscopy micrographs indicate that the hybridization event leads to the bridging of the gold nanoparticles to the magnetic beads. Further signal amplification, and lowering of the detection limits to the nanomolar and picomolar domains, are achieved by precipitating gold or silver, respectively, onto the colloidal gold label. The new electrochemical stripping metallogenomagnetic protocol couples the inherent signal amplification of stripping metal analysis with discrimination against nonhybridized DNA, the use of microliter sample volumes, and disposable transducers and, hence, offers great promise for decentralized genetic testing.  相似文献   

9.
This paper reports on the characterization and preliminary comparison of gold nanoparticles of differing surface modification and shape when used as extrinsic Raman labels (ERLs) in high-sensitivity heterogeneous immunoassays based on surface enhanced Raman scattering (SERS). ERLs are gold nanoparticles coated with an adlayer of an intrinsically strong Raman scatterer, followed by a coating of a molecular recognition element (e.g., antibody). Three types of ERLs, all with a nominal size of approximately 30 nm, were fabricated by using spherical citrate-capped gold nanoparticles (sp-cit-Au NPs), spherical CTAB-capped gold nanoparticles (sp-CTAB-Au NPs), or cube-like CTAB-capped gold nanoparticles (cu-CTAB-Au NPs) as cores. The performance of these particles was assessed via a sandwich immunoassay for human IgG in phosphate buffered saline. The ERLs fabricated with sp-CTAB-Au NPs as cores proved to be more than 50 times more sensitive than those with sp-cit-Au NPs as cores; the same comparison showed that the ERLs with cu-CTAB-Au NPs as cores were close to 200 times more sensitive. Coupled with small differences in levels of nonspecific adsorption, these sensitivities translated to a limit of detection (LOD) of 94, 2.3, and 0.28 ng/mL, respectively, for the detection of human IgG in the case of sp-cit-Au NPs, sp-CTAB-Au NPs, and cu-CTAB-Au NPs. The LOD of the cu-CTAB-Au NPs is therefore approximately 340 times below that for the sp-cit-Au NPs. Potential applications of these labels to bioassays are briefly discussed.  相似文献   

10.
Fan A  Lau C  Lu J 《Analytical chemistry》2005,77(10):3238-3242
A novel, sensitive chemiluminescent (CL) immunoassay has been developed by taking advantage of a magnetic separation/mixing process and the amplification feature of colloidal gold label. First, the sandwich-type complex is formed in this protocol by the primary antibody immobilized on the surface of magnetic beads, the antigen in the sample, and the second antibody labeled with colloidal gold. Second, a large number of Au3+ ions from each gold particle anchored on the surface of magnetic beads are released after oxidative gold metal dissolution and then quantitatively determined by a simple and sensitive Au3+-catalyzed luminol CL reaction. Third, this protocol is evaluated for a noncompetitive immunoassay of a human immunoglobulin G, and a concentration as low as 3.1 x 10(-12) M is determined, which is competitive with colloidal gold-based anodic stripping voltammetry (ASV), colorimetric ELISA, or immunoassays based on fluorescent europium chelate labels. The high performance of this protocol is related to the sensitive CL determination of Au3+ ion (detection limit of 2 x 10(-10) M), which is 25 times higher than that by ASV at a single-use carbon-based screen-printed electrode. From the analytical chemistry point of view, this protocol will be quite promising for numerous applications in immunoassay and DNA hybridization.  相似文献   

11.
An electrochemical immunoassay for cardiac troponin I (cTnI) combining the concepts of the dual monoclonal antibody "sandwich" principle, the silver enhancement on the nano-gold particle, and the anodic stripping voltammetry is described. Four main steps were carried out to obtain the analytical signal, i.e., electrode preparation, immunoreaction, silver enhancement, and anodic stripping voltammetric detection. A linear relationship between the anodic stripping peak current and concentration of cTnl from 1 to 20 ng/ml and a limit of detection of 0.8 ng/ml were obtained. The established method was tested by determining cTnI in acute myocardial infarction (AMI) samples using enzyme-linked immunoadsorbent assay (ELISA) for comparison analysis, and good results were obtained.  相似文献   

12.
An electrochemical metalloimmunoassay based on a colloidal gold label   总被引:9,自引:0,他引:9  
A novel, sensitive electrochemical immunoassay has been developed using a colloidal gold label that, after oxidative gold metal dissolution in an acidic solution, was indirectly determined by anodic stripping voltammetry (ASV) at a single-use carbon-based screen-printed electrode (SPE). The use of disposable electrodes allows for simplified measurement in 35 microL of solution. The method was evaluated for a noncompetitive heterogeneous immunoassay of an immunoglobulin G (IgG) and a concentration as low as 3 x 10(-12) M was determined, which is competitive with colorimetric ELISA or with immunoassays based on fluorescent europium chelate labels. The high performance of the method is related to the sensitive ASV determination of gold(III) at a SPE (detection limit of 5 x 10(-9) M) and to the release of a large number of gold(III) ions from each gold particle anchored on the immunocomplex (e.g., 1.7 x 10(5) gold atoms are theoretically contained in a 18-nm spherical gold particle).  相似文献   

13.
This work reports a novel electrochemical immunoassay protocol with signal amplification for determination of proteins (human IgG here used as a model target analyte) at an ultralow concentration using DNA-based hybridization chain reaction (HCR). The immuno-HCR assay consists of magnetic immunosensing probes, nanogold-labeled signal probes conjugated with the DNA initiator strands, and two different hairpin DNA molecules. The signal is amplified by the labeled ferrocene on the hairpin probes. In the presence of target IgG, the sandwiched immunocomplex can be formed between the immobilized antibodies on the magnetic beads and the signal antibodies on the gold nanoparticles. The carried DNA initiator strands open the hairpin DNA structures in sequence and propagate a chain reaction of hybridization events between two alternating hairpins to form a nicked double-helix. Numerous ferrocene molecules are formed on the neighboring probe, each of which produces an electrochemical signal within the applied potentials. Under optimal conditions, the immuno-HCR assay presents good electrochemical responses for determination of target IgG at a concentration as low as 0.1 fg mL(-1). Importantly, the methodology can be further extended to the detection of other proteins or biomarkers.  相似文献   

14.
Lai G  Yan F  Wu J  Leng C  Ju H 《Analytical chemistry》2011,83(7):2726-2732
A novel ultrasensitive multiplexed immunoassay method was developed by combining alkaline phosphatase (ALP)-labeled antibody functionalized gold nanoparticles (ALP-Ab/Au NPs) and enzyme-Au NP catalyzed deposition of silver nanoparticles at a disposable immunosensor array. The immunosensor array was prepared by covalently immobilizing capture antibodies on chitosan modified screen-printed carbon electrodes. After sandwich-type immunoreactions, the ALP-Ab/Au NPs were captured on an immunosensor surface to catalyze the hydrolysis of 3-indoxyl phosphate, which produced an indoxyl intermediate to reduce Ag(+). The silver deposition process was catalyzed by both ALP and Au NPs, which amplified the detection signal. The deposited silver was then measured by anodic stripping analysis in KCl solution. Using human and mouse IgG as model analytes, this multiplexed immunoassay method showed wide linear ranges over 4 orders of magnitude with the detection limits down to 4.8 and 6.1 pg/mL, respectively. Acceptable assay results for practical samples could be obtained. The newly designed strategy avoided cross talk and the need of deoxygenation for the electrochemical immunoassay and, thus, provided a promising potential in clinical applications.  相似文献   

15.
This paper describes the study of atomization of nanoparticles by inductively coupled plasma mass spectrometry (ICPMS) and developes a novel nonisotopic immunoassay by coupling sandwich-type immunoreaction to ICPMS. The goat-anti-rabbit immunoglobulin G (IgG) labeled with colloidal gold nanoparticles served as an analyte in ICPMS for the indirect measurement of rabbit-anti-human IgG. Matrix effect studies showed the gold signal was not sensitive to the organic matrix. A relatively good correlation (r2 = 0.9528) between the proposed method and enzyme-linked immunosorbent assay has been obtained. The method may have significant potential as an important ICPMS-based nonisotopic immnoassay method for the simultaneous determination of biologic analytes of interest by labeling different kinds of inorganic nanoparticles.  相似文献   

16.
We report a fully automated sandwich immunoassay for the determination of human insulin using antibody-protein A-bacterial magnetic particle (BMP) complexes and an alkaline phosphatase-conjugated secondary antibody. BMPs bearing protein A-MagA inserted on the external surface of the membrane were prepared in the Magnetospirillum sp. AMB-1 transconjugant for a protein A-magA fusion gene. MagA protein was used as an anchor to attach protein A onto the membrane. Protein A-BMP complexes harvested from transconjugant AMB-1 were subsequently complexed with anti-human insulin antibodies by specific binding between the Z domain of protein A and the Fc component of IgG to form the antibody-protein A-BMP complexes. The complexes were quite monodisperse after the binding of the antibody. The BMPs' monodispersity resulted in high signal and low noise in the immunoassay. The luminescence intensity ((kilocounts/s)/microg of antibody) from antibody-protein A-BMP complexes after immunoreaction was higher than that from BMPs chemically conjugated to an antibody. This was explained by a difference in dispersion. The fully automated sandwich immunoassay system using antibody-protein A-BMP complexes made possible precise assays of human insulin in serum.  相似文献   

17.
A novel reagent for low-level detection in immunoadsorbent assays is described. The reagent consists of gold nanoparticles modified to integrate bioselective species (e.g., antibodies) with molecular labels for the generation of intense, biolyte-selective surface-enhanced Raman scattering (SERS) responses in immunoassays and other bioanalytical applications. The reagent is constructed by coating gold nanoparticles (30 nm) with a monolayer of an intrinsically strong Raman scatterer. These monolayer-level labels are bifunctional by design and contain disulfides for chemisorption to the nanoparticle surface and succinimides for coupling to the bioselective species. There are two important elements in this label design; it both minimizes the separation between label and particle surface and maximizes the number of labels on each particle. This approach to labeling also exploits several other advantages of SERS-based labels: narrow spectral bandwidth, resistance to photobleaching and quenching, and long-wavelength excitation of multiple labels with a single excitation source. The strengths of this strategy are demonstrated in the detection of free prostate-specific antigen (PSA) using a sandwich assay format based on monoclonal antibodies. Detection limits of approximately 1 pg/mL in human serum and approximately 4 pg/mL in bovine serum albumin have been achieved with a spectrometer readout time of 60 s. The extension of the method to multianalyte assays (e.g., the simultaneous determination of the many complexed forms of PSA) is discussed.  相似文献   

18.
Cui R  Pan HC  Zhu JJ  Chen HY 《Analytical chemistry》2007,79(22):8494-8501
A versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels has been developed for sensitive protein detection. This sandwich-type sensor is fabricated on an indium tin oxide chip covered with a well-ordered gold nanoparticle monolayer. Gel imaging systems were successfully introduced to develop a novel high-efficient optical immunoassay, which could perform simultaneous detection for the samples with a series of different concentrations of a target analyte. The linear range of this assay was between 0.1 and 500 ng/mL, and the assay sensitivity could be further increased to 0.005 ng/mL with the linear range from 0.005 to 100 ng/mL by stripping voltammetric analysis. The immunosensor showed good precision, high sensitivity, acceptable stability, and reproducibility and could be used for the detection of real sample with consistent results in comparison with those obtained by the ELISA method.  相似文献   

19.
Lin D  Wu J  Wang M  Yan F  Ju H 《Analytical chemistry》2012,84(8):3662-3668
A triple signal amplification strategy was designed for ultrasensitive immunosensing of cancer biomarker. This strategy was achieved using graphene to modify immunosensor surface for accelerating electron transfer, poly(styrene-co-acrylic acid) microbead (PSA) carried gold nanoparticles (AuNPs) as tracing tag to label signal antibody (Ab(2)) and AuNPs induced silver deposition for anodic stripping analysis. The immunosensor was constructed by covalently immobilizing capture antibody on chitosan/electrochemically reduced graphene oxide film modified glass carbon electrode. The in situ synthesis of AuNPs led to the loading of numerous AuNPs on PSA surface and convenient labeling of the tag to Ab(2). With a sandwich-type immunoreaction, the AuNPs/PSA labeled Ab(2) was captured on the surface of an immunosensor to further induce a silver deposition process. The electrochemical stripping signal of the deposited silver nanoparticles in KCl was used to monitor the immunoreaction. The triple signal amplification greatly enhanced the sensitivity for biomarker detection. The proposed method could detect carcinoembryonic antigen with a linear range of 0.5 pg mL(-1) to 0.5 ng mL(-1) and a detection limit down to 0.12 pg mL(-1). The immunosensor exhibited good stability and acceptable reproducibility and accuracy, indicating potential applications in clinical diagnostics.  相似文献   

20.
Liu G  Lin Y 《Analytical chemistry》2005,77(18):5894-5901
An electrochemical sensor for detection of organophosphate (OP) pesticides and nerve agents using zirconia (ZrO2) nanoparticles as selective sorbents is presented. Zirconia nanoparticles were electrodynamically deposited onto the polycrystalline gold electrode by cyclic voltammetry. Because of the strong affinity of zirconia for the phosphoric group, nitroaromatic OPs strongly bind to the ZrO2 nanoparticle surface. The electrochemical characterization and anodic stripping voltammetric performance of bound OPs were evaluated using cyclic voltammetric and square-wave voltammetric (SWV) analysis. SWV was used to monitor the amount of bound OPs and provide simple, fast, and facile quantitative methods for nitroaromatic OP compounds. The sensor surface can be regenerated by successively running SWV scanning. Operational parameters, including the amount of nanoparticles, adsorption time, and pH of the reaction medium have been optimized. The stripping voltammetric response is highly linear over the 5-100 ng/mL (ppb) methyl parathion range examined (2-min adsorption), with a detection limit of 3 ng/mL and good precision (RSD = 5.3%, n = 10). The detection limit was improved to 1 ng/mL by using 10-min adsorption time. The promising stripping voltammetric performances open new opportunities for fast, simple, and sensitive analysis of OPs in environmental and biological samples. These findings can lead to a widespread use of electrochemical sensors to detect OP contaminates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号