首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
Longitudinal vortices are capable of producing beneficial effects in heat transfer enhancement. Experiments in natural convection heat transfer enhancement were done on a vertical flat heating plate using delta‐winglet longitudinal vortex generators (LVGs) arranged in rows. In an experimental range of Rayleigh number, the height and width of the winglet of the longitudinal vortex generator (LVG), the array form of the longitudinal vortex generators on the heat transfer performance were experimentally investigated, and the best height of the winglet of the longitudinal vortex generator was obtained. The results showed the change of the array form of the longitudinal vortex generators could affect the heat transfer effect. Finally by arranging some longitudinal vortex generator arrays with the appropriate interval, the whole heat transfer effect of the interval could reach a prime value. © 2006 Wiley Periodicals, Inc. Heat Trans Asian Res, 35(5): 351–358, 2006; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20119  相似文献   

2.
This paper focuses on the study of heat transfer enhancement in natural vertical convection by using delta‐winglet longitudinal vortex generators. In the experimental range of Rayleigh numbers, the effect of attack angle, height, and width of the winglet of longitudinal vortex generator (LVG) on heat transfer performance was experimentally investigated. The results showed that there was an optimal attack angle and that the height and width can affect the heat transfer. In terms of array performance, it was shown that initial arrays could enhance the performance of later arrays. Moreover, the effects of LVG and low rectangular fins were compared. The results showed that the effect of LVGs was greater than that of low rectangular fins. © 2006 Wiley Periodicals, Inc. Heat Trans Asian Res, 35(6): 402–409, 2006; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20126  相似文献   

3.
This study presents numerical computation results on laminar convection heat transfer in a plate‐fin heat exchanger, with triangular fins between the plates of a plate‐fin heat exchanger. The rectangular winglet type vortex generator is mounted on these triangular fins. The performance of the vortex generator is evaluated for varying angles of attack of the winglet i.e., 20, 26, and 37° and Reynolds number 100, 150, and 200. The computations are also performed by varying the geometrical size and location of the winglet. The complete Navier–Stokes equation and the energy equation are solved by the (Marker and Cell) MAC algorithm using the staggered grid arrangement. The constant wall temperature thermal boundary conditions are considered. Air is taken as the working fluid. The heat transfer enhancement is seen by introducing the vortex generator. Numerical results show that the average Nusselt number increases with an increase in the angle of attack and Reynolds number. For the same area of the LVG, the increase in length of the LVG brings more heat transfer enhancement than increasing the height. The increase in heat transfer comes with a moderate pressure drop penalty. © 2010 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com ). DOI 10.1002/htj.20318  相似文献   

4.
Three-dimensional numerical simulation results are presented for a fin-and-tube heat transfer surface with vortex generators. The effects of the Reynolds number (from 800 to 2 000) and the attack angle (30° and 45°) of a delta winglet vortex generator are examined. The numerical results are analyzed on the basis of the field synergy principle to explain the inherent mechanism of heat transfer enhancement by longitudinal vortex. The secondary flow generated by the vortex generators causes the reduction of the intersection angle between the velocity and fluid temperature gradients. In addition, the computational evaluations indicate that the heat transfer enhancement of delta winglet pairs for an aligned tube bank fin-and-tube surface is more significant than that for a staggered tube bank fin-and-tube surface. The heat transfer enhancement of the delta winglet pairs with an attack angle of 45° is larger than that with an angle of 30°. The delta winglet pair with an attack angle of 45° leads to an increase in pressure drop, while the delta winglet pair with the 30° angle results in a slight decrease. The heat transfer enhancement under identical pumping power condition for the attack angle of 30° is larger than that for the attack angle of 45° either for staggered or for aligned tube bank arrangement. Translated from Journal of Xi’an Jiao Tong University, 2006, 40(7): 757–761 [译自: 西安交通大学学报]  相似文献   

5.
3-D numerical simulations were presented for laminar flow and heat transfer characteristics in a rectangular channel with vortex generators. The effects of Reynolds number (from 800 to 3 000), the attack angle of vortex generator (from 15° to 90°) and the shape of vortex generator were examined. The numerical results were analyzed based on the field synergy principle. It is found that the inherent mechanism of the heat transfer enhancement by longitudinal vortex can be explained by the field synergy principle, that is, the second flow generated by vortex generators results in the reduction of the intersection angle between the velocity and fluid temperature gradient. The longitudinal vortex improves the field synergy of the large downstream region of longitudinal vortex generator (LVG) and the region near (LVG); however, transverse vortex only improves the synergy of the region near vortex generator. Thus, longitudinal vortex can enhance the integral heat transfer of the flow field, while transverse vortex can only enhance the local heat transfer. The synergy angle decreases with the increase of Reynolds number for the channel with LVG to differ from the result obtained from the plain channel, and the triangle winglet performs better than the rectanglar one under the same surface area condition. __________ Translated from Journal of Xi’an Jiaotong University, 2006, 40(9): 996–1000 [译自: 西安交通大学学报]  相似文献   

6.
将纵向涡强化换热技术应用于矩形管槽,研究以水为换热介质在过渡流状态下的换热效果。实验结果表明有纵向涡发生器的换热效果明显优于无纵向涡发生器的情况。利用PHEON ICS计算软件对实验进行数值模拟,模拟值与实验值符合较好。在此基础上,改变纵向涡的翼高和形状来模拟,发现两者均为换热影响的因素,相比之下,高宽比为0.4纵向涡发生器的换热效果比高宽比为0.5和0.6的要好。而采用相同高宽的矩形翼时,N u高于三角翼,但其换热性能指标却低于直角三角翼。  相似文献   

7.
Three‐dimensional numerical simulations are performed on a plate‐fin heat exchanger (with triangular fins as inserts between the plates) to evaluate the laminar heat transfer and fluid flow characteristics with longitudinal vortex generators (LVGs). The effect with an inline rectangular winglet pair (RWP) with a common‐flow‐down (CFD) configuration is studied. The numerical results indicate that the application of inline LVGs effectively enhances the heat transfer of the channel. The heat transfer further increases with the increase in the Reynolds number from 200 to 500 and angle of attack from β = 15° to 22.5°. The computations are also performed to find the best location for the second RWP. © 2012 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.20414  相似文献   

8.
This paper presents the influences of main parameters of longitudinal vortex generator (LVG) on the heat transfer enhancement and flow resistance in a rectangular channel. The parameters include the location of LVG in the channel, geometric sizes and shape of LVG. Numerical results show that the overall Nusselt number of channel will decrease with the LVGs’ location away from the inlet of the channel, and decrease too with the space between the LVG pair decreased. The location of LVG has no significant influence on the total pressure drop of channel. With the area of LVG increased, the average Nusselt number and the flow loss penalty of channel, especially when β = 45° will increase. With the area of LVG fixed, increasing the length of rectangular winglet pair vortex generator will bring about more heat transfer enhancement and less flow loss increase than that increasing the height of rectangular winglet pair vortex generator. With the same area of LVG, delta winglet pair is more effective than rectangular winglet pair on heat transfer enhancement of channel, and delta winglet pair-b is more effective than delta winglet pair-a. Delta winglet pair-a results in a higher pressure drop, the next is rectangular winglet pair and the last is delta winglet-b. The increase of heat transfer enhancement is always accompanied with the decrease of field synergy angle between the velocity and temperature gradient when the parameters of LVG are changed. This confirms again that the field synergy is the fundamental mechanism of heat transfer by longitudinal vortex. The laminar heat transfer of the channel with punched delta winglet pair is experimentally and numerically studied in the present paper. The numerical result for the average heat transfer coefficient of the channel agrees well with the experimental result, indicating the reliability of the present numerical predictions.  相似文献   

9.
多排纵向涡发生器强化竖直平板自然对流换热的实验研究   总被引:1,自引:0,他引:1  
对多排纵向涡发生器对竖直平板自然对流的强化效果进行了研究。结果表明,在一定Rayleigh数范围内,直角三角翼纵向涡发生器的翼高、翼宽以及多排布置的阵列方式是影响强化换热的主要因素。在高宽比一定的情况下,存在最佳翼高。发现多排布置时LVG阵列方式的不同会影响换热效果;且要使得整个板的强化换热效果达到最佳,应选择沿竖直发热板长度方向间隔的布置多排LVG,并适当拉大间隔距离。  相似文献   

10.
《Applied Thermal Engineering》2007,27(14-15):2609-2617
3-D numerical simulation results are presented for laminar flow heat transfer of the fin-and-tube surface with vortex generators. The effects of Reynolds number (from 800 to 2000), the attack angle (30° and 45°) of delta winglet vortex generator are examined. The numerical results are analyzed from the viewpoint of field synergy principle. It is found that the inherent mechanism of heat transfer enhancement by longitudinal vortex can be explained by the field synergy principle, the second flow generated by the vortex generators results in the reduction of the intersection angle between the velocity and fluid temperature gradient. In addition, the heat transfer enhancement of delta winglet with the attack angle of 45° is larger than that of 30°, while the delta winglet with the attack angle of 45° results in an increase of the pressure drop, however, the delta winglet with the attack angle of 30° results in a slight decrease.  相似文献   

11.
This study presents numerical computation results on laminar convection heat transfer in a rectangular channel with a pair of rectangular winglets longitudinal vortex generator punched out from the lower wall of the channel. The effect of the punched holes and the thickness of the rectangular winglet pair to the fluid flow and heat transfer are numerically studied. It is found that the case with punched holes has more heat transfer enhancement in the region near to the vortex generator and lower average flow frictional coefficient compared with the case without punched holes. The thickness of rectangular winglet can cause less heat transfer enhancement in the region near to the vortex generator and almost has no significant effect on the total pressure drop of the channel. The effects of Reynolds number (from 800 to 3000), the attack angle of vortex generator (15°, 30°, 45°, 60° and 90°) were examined. The numerical results were analyzed from the viewpoint of field synergy principle. It was found that the essence of heat transfer enhancement by longitudinal vortex can be explained very well by the field synergy principle, i.e., when the second flow generated by vortex generators results in the reduction of the intersection angle between the velocity and fluid temperature gradient, the heat transfer in the present channels will be enhanced. Longitudinal vortices (LVs) improve the synergy between velocity and temperature field not only in the region near LVG but also in the large downstream region of longitudinal vortex generator. So LVs enable to enhance the global heat transfer of channel. Transverse vortices (TVs) only improve the synergy in the region near VG. So TVs can only enhance the local heat transfer of channel.  相似文献   

12.
3-D numerical simulations were presented for laminar flow and heat transfer characteristics in a rectangular channel with vortex generators. The effects of Reynolds number (from 800 to 3 000), the attack angle of vortex generator (from 15° to 90°) and the shape of vortex generator were examined. The numerical results were analyzed based on the field synergy principle. It is found that the inherent mechanism of the heat transfer enhancement by longitudinal vortex can be explained by the field synergy principle, that is, the second flow generated by vortex generators results in the reduction of the intersection angle between the velocity and fluid temperature gradient. The longitudinal vortex improves the field synergy of the large downstream region of longitudinal vortex generator (LVG) and the region near (LVG); however, transverse vortex only improves the synergy of the region near vortex generator. Thus, longitudinal vortex can enhance the integral heat transfer of the flow field, while transverse vortex can only enhance the local heat transfer. The synergy angle decreases with the increase of Reynolds number for the channel with LVG to differ from the result obtained from the plain channel, and the triangle winglet performs better than the rectanglar one under the same surface area condition.  相似文献   

13.
雷诺数Re=214~10 703时,通过数值模拟方法对布置有冲孔和无孔的两种矩形小翼涡流发生器的矩形通道进行了传热和流阻特性的研究。计算结果表明:在低雷诺数下,冲孔矩形小翼涡流发生器的传热因子j值与无孔矩形小翼涡流发生器相差不大,而在高雷诺数下,冲孔涡流发生器的传热因子j值略低于无孔涡流发生器,大约低1.03%~3.05%。在相同的雷诺数下,无孔矩形小翼涡流发生器的阻力因子f大于冲孔涡流发生器,而且随着雷诺数的增大二者的差距也越来越大。通过对比综合性能指标可知,两种通道的综合性能指标均随着雷诺数的增加而减小,而且冲孔矩形小翼涡流发生器的综合性能要优于无孔矩形小翼涡流发生器。  相似文献   

14.
This study is to experimentally investigate the heat transfer enhancement by delta winglet vortex generators in air cooling of a staggered array of rectangular electronic modules. The winglet vortex generators are placed in front of 3 × 5 modules with 20° attack angle. Each module has dimensions of 1.8 × 5.4 × 0.6 mm and each one generates heat at 2.5 W. The adiabatic heat transfer coefficients, the thermal wake functions including their correlations for the modules with and without the vortex generators are considered at different values of Reynolds number and the module density. It could be seen that the vortex generators could enhance the adiabatic heat transfer coefficients, reduce the thermal wake functions and the module temperatures significantly. The module temperatures predicted by the superposition of the convective effect due to the module heat generations and the module thermal wakes are fitted very well with the measured data.  相似文献   

15.
Laminar forced convection heat transfer and nanofluids flow in an equilateral triangular channel using a delta‐winglet pair of vortex generators is numerically studied. Three nanofluids, namely; Al2O3, CuO, and SiO2 nanoparticles suspended in an ethylene glycol base fluid are examined. A two‐phase mixture model is considered to simulate the governing equations of mass, momentum and energy for both phases and solved using the finite volume method (FVM). Constant and temperature dependent properties methods are assumed. The single‐phase model is considered here for comparison. The nanoparticle concentration is assumed to be 1% and 4% and Reynolds number is ranged from 100 to 800. The results show that the heat transfer enhancement by a using vortex generator and nanofluids is greater than the case of vortex generator and base fluid only, and the latest case provided higher enhancement of heat transfer compared to the case of a base fluid flowing in a plain duct. Considering the nanofluid as two separated phases is more reasonable than assuming the nanofluid as a homogeneous single phase. Temperature dependent properties model provided higher heat transfer and lower shear stress than the constant properties model.  相似文献   

16.
The present numerical analysis pertains to the heat transfer enhancement in a plate‐fin heat exchanger employing triangular shaped fins with a rectangular wing vortex generator on its slant surfaces. The study has been carried out for three different angles of attack of the wing, i.e., 15°, 20° and 26°. The aspect ratio of the wing is not varied with its angle of attack. The flow considered herein is laminar, incompressible, and viscous with the Reynolds number not exceeding 200. The pressure and the velocity components are obtained by solving the continuity and the Navier– Stokes equations by the Marker and Cell method. The present analysis reveals that the use of a rectangular wing vortex generator at an attack angle of 26° results in about a 35% increase in the combined spanwise average Nusselt number as compared to the plate‐triangular fin heat exchanger without any vortex generator. © 2010 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20285  相似文献   

17.
This experiment was carried out using delta winglet arrays of vortex generators (VG) with inline arrangement in a tube heat exchanger to study enhanced heat transfer and flow behaviour. The experiment was conducted for the turbulent flow (Re = 6000 to 27000). In this experiment, different parameters, pitch ratios (PR = 1.6, 2.4, and 4.8), lengths (L = 10, 15, and 20 mm), and attack angles (B = 0°, 10°, 20°, 30°, and 45°) were studied and then their effect on thermal performance was observed. Results indicate that the PR affected f and Nu significantly. For PR = 1.6, VGs showed the highest f and Nu for all of the cases. Vortex generators with L10 B45 PR4.8 achieved the best TPE with 1.23 at Re = 6000. Attack angle B indicated a significant impact on thermal performance and 45 degree showed the TPE of 1.23 at lower Re. Oil film flow and smoke flow visualization were employed to identify the flow vortices and understand flow mechanism. The oil film flow and smoke flow visualization clearly traced longitudinal vortex, and induced vortex, which induced impingement flow and recirculation zone that lead to significant heat transfer enhancement.  相似文献   

18.
《Applied Thermal Engineering》2005,25(11-12):1684-1696
Local heat transfer coefficients were measured on fin-tube heat exchanger with winglets using a single heater of 2 inch diameter and five different positions of winglet type vortex generators. The measurements were made at Reynolds number about 2250. Flow losses were determined by measuring the static pressure drop in the system. Results showed a substantial increase in the heat transfer with winglet type vortex generators. It has been observed that average Nusselt number increases by about 46% while the local heat transfer coefficient improves by several times as compared to plain fin-tube heat exchanger. The maximum improvement is observed in the re-circulation zone. The best location of the winglets was with ΔX = 0.5D and ΔY = 0.5D. The increase in pressure drop for the existing situation was of the order of 18%.  相似文献   

19.
This paper summarizes the current state of the art related to improvement of the heat exchanger surfaces using streamwise longitudinal vortices. Primarily, the improvements related to fin-tube cross-flow heat exchangers and the plate-fin heat exchangers have been addressed. Protrusions in certain forms, such as delta wings or winglet pairs, act as vortex generators, which can enhance the rate of heat transfer from the heat-exchanger surfaces that may be flat or louvered. The strategically placed vortex generators create longitudinal vortices, which disrupt the growth of the thermal boundary layer, promote mixing between fluid layers, and hence lead to augmentation in heat transfer. The flow fields are dominated by swirling motion associated with modest pressure penalty. Heat transfer is augmented substantially for all the proposed configurations of the longitudinal vortex generators, such as delta wings, rectangular winglet pairs, and delta winglet pairs, with varying degree of pressure penalty. Both computational and experimental investigations on flow and heat transfer in the heat exchanger passages with built-in vortex generators are revisited and summarized.  相似文献   

20.
ABSTRACT

Novel types of double delta winglets (DDWTs) and double delta winglet with holes (DDWTHs) have been developed. The influence of parameters, including the angle of DDWTs and the distance between DDWTs, on thermal enhancement and flow resistance characteristics in a rectangular channel is examined. The results reveal that the larger angle and increasing distance could make an active role in turbulent heat transfer enhancement, and slight influence on laminar flow. According to the field profile, the cross-flow and encircling flow are generated by DDWTs, which increases the mixing efficiency and reduces the thermal boundary layer thickness as well. Vortex generators, such as delta wings, rectangular wings, DDWTs, and DDWTHs, are compared. The delta wings and rectangular wings perform better heat transfer enhancement and higher resistance, while the DDWTs and DDWTHs have better overall heat transfer performance, especially for large Reynolds numbers.  相似文献   