The thermal performance of a prototype solar cooker based on an evacuated tube solar collector with phase change material (PCM) storage unit is investigated. The design has separate parts for energy collection and cooking coupled by a PCM storage unit. Solar energy is stored in the PCM storage unit during sunshine hours and is utilized for cooking in late evening/night time. Commercial grade erythritol was used as a latent heat storage material. Noon and evening cooking experiments were conducted with different loads and loading times. Cooking experiments and PCM storage processes were carried out simultaneously. It was observed that noon cooking did not affect the evening cooking, and evening cooking using PCM heat storage was found to be faster than noon cooking. The cooker performance under a variety of operating and climatic conditions was studied at Mie, Japan. 相似文献
2.
This paper presents the results of a thermal performance analysis of a phase change thermal storage unit. The unit consists of several parallel flat slabs of phase change material (PCM) with a liquid heat transfer fluid (HTF) flowing along the passages between the slabs. A validated numerical model developed previously to solve the phase change problem in flat slabs was used. An insight is gained into the melting process by examining the temperatures of the HTF nodes, wall nodes and PCM nodes and the heat transfer rates at four phases during melting. The duration of the melting process is defined based on the level of melting completion. The effects of several parameters on the HTF outlet temperature, heat transfer rate and melting time are evaluated through a parametric study to evaluate the effects of the HTF mass flow rate, HTF inlet temperature, gap between slabs, slab dimensions, PCM initial temperature and thermal conductivity of the container on the thermal performance. The results are used to design a phase change thermal storage unit for a refrigerated truck. 相似文献
3.
A composite based on paraffin, styrene–butadiene–styrene (SBS) triblock copolymer and exfoliated graphite (EG) is prepared. In this composite, paraffin undergoes solid–liquid phase change in the SBS network, and there is no leakage of it even in the state of melting. The composite exhibits high thermal conductivity and nearly 80% of the latent heat of fusion per unit mass of the paraffin. 相似文献
4.
The design, construction and performance evaluation of a passive solar powered air heating system is presented. The system, which has potential applications in crop drying and poultry egg incubation, consists of a single-glazed flat plate solar collector integrated with a phase change material (PCM) heat storage system. The PCM is prepared in modules, with the modules equispaced across the absorber plate. The spaces between the module pairs serve as the air heating channels, the channels being connected to common air inlet and discharge headers. The system was tested experimentally under daytime no-load conditions at Nsukka, Nigeria, over the ambient temperature range of 19–41 °C, and a daily global irradiation range of 4.9–19.9 MJ m−2. Peak temperature rise of the heated air was about 15 K, while the maximum airflow rate and peak cumulative useful efficiency were about 0.058 kg s−1 and 22%, respectively. These results show that the system can be operated successfully for crop drying applications. With suitable valves to control the working chamber temperature, it can also operate as a poultry egg incubator. 相似文献
5.
This communication presents the periodic heat transfer analysis for solar space heating of an unconditioned building with an integrated roof air heater. The system consists of an air duct within the roof such that the air is continuously or intermittently forced to circulate the cooler room air through the inlet of the air duct. Time dependence of the air flow is represented by a step function of time for daily operation and, hence, has been expressed as a Fourier series in time. The analysis takes into account air ventilation, ground heat conduction and furnishings. The effects of depth of the air duct from the outer surface of the roof and the magnitude and duration of air flow rate on indoor air temperature have been studied for a typical cold winter day in Delhi. It is seen that a time dependent air flow through the duct is desirable from the point of view of increasing the indoor air temperature in the case of a bare roof. However, in the case of a blackened and glazed roof, continuous air flow is needed for increasing the room air temperature. The results are desirable from the point of view of efficient space heating of solar passive buildings. 相似文献
6.
《能源学会志》2020,93(1):76-86
To explore thermal management integration in electric vehicles (EVs), a phase change materials (PCMs) thermal energy storage unit using flat tubes and corrugated fins is designed. The investigation focuses on the thermal characteristics of the PCM unit, such as the temperature variation, heat capacity, and heat transfer time, etc. Meanwhile, the heat storage and release process will be influenced by different inlet temperature, liquid flow rate, melting point of the PCM, and the combination order of the units. Under the same inlet temperature and flow rate condition, the PCM unit with higher melting point enters the latent heat storage stage slowly and enters the phase change melting release stage quickly. Furthermore, the heat storage and release rates increase with increasing liquid flow rates, but the effects are diminishing in the middle and later periods. The multiple PCM units with different melting temperatures are cascaded to help recycle low-grade heat energy with different temperature classes and exhibit well heat storage and release rates. 相似文献
7.
A transient finite volume model was used to predict collection and retention of heat for rectangular cross section solar collector/storage systems when filled with water and various concentrations of phase change material (PCM) slurries with a 65 °C phase change temperature. It was found that the PCM slurry systems collected heat marginally less effectively than water filled stores. Retention of heat at higher temperatures in the PCM slurry systems may allow higher solar savings fractions to be realised depending on heat demand patterns. 相似文献
8.
The thermal response of a multi-tank thermal storage was studied under variable charge conditions. Tests were conducted on an experimental apparatus that simulated the thermal charging of the storage system by a solar collector over predetermined (prescribed) daylong periods. The storage was assembled from three standard 270 L hot-water storage tanks each charged through coupled, side-arm, natural convection heat exchangers which were connected in either a series- or parallel-flow configuration. Both energy storage rates and tank temperature profiles were experimentally measured during charge periods representative of two consecutive clear days or combinations of a clear and overcast day. During this time, no draw-offs were conducted. Of particular interest was the effect of rising and falling charge-loop temperatures and collector-loop flow rate on storage tank stratification levels. Results of this study show that the series-connected thermal storage reached high levels of temperature stratification in the storage tanks during periods of rising charge temperatures and also limited destratification during periods of falling charge temperature. This feature is a consequence of the series-connected configuration that allowed sequential stratification to occur in the component tanks and energy to be distributed according to temperature level. This effect was not observed in the parallel charge configuration. A further aspect of the study investigated the effect of increasing charge-loop flow rate on the temperature distribution within the series-connected storage and showed that, at high flow rates, the temperature distributions were found to be similar to those obtained during parallel charging. A disadvantage of both the high-flow series-connected and parallel-connected multi-tank storage is that falling charge-loop temperatures, which normally occur in the afternoon, tend to mix and destratify the storage tanks. 相似文献
9.
The thermal performance of a solar chimney without and with phase change material (PCM) has been experimentally studied in this paper. For the case of solar chimney with PCM, three different modes (closed-fully charging mode, open-partly charging mode and open-fully charging mode) were developed. The closed mode was designed to maximize the use of the solar energy when the heating is not required. Whilst the open mode was designed for delivering the heated air to the living space during charging period. The results showed that the inclusion of PCM to a solar chimney would reduce the air flow during charging period but increase it during discharging period compared with the solar chimney without PCM. For the open-partly mode, the mean air flow rate during phase change period was only 0.036 kg/s, which was lower than that for closed-fully charging mode (0.041 kg/s). Regarding the open-fully charging mode, the melting time of the PCM was almost 11 h, which was 57% longer than that for closed mode. The mean air flow rate during phase change period was 0.04 kg/s, which was higher than that for open-partly mode but lower than that for closed mode. 相似文献
10.
Thermal and economical analysis of a central solar heating system with underground seasonal storage in Turkey 总被引:1,自引:0,他引:1
Thermal performance and economic feasibility of two types of central solar heating system with seasonal storage under four climatically different Turkey locations are investigated. The effects of storage volume and collector area on the thermal performance and cost are studied for three load sizes. The simulation model of the system consisting of flat plate solar collectors, a heat pump, under ground storage tank and heating load based on a finite element analysis and finite element code ANSYS™ is chosen as a convenient tool. In this study, the lowest solar fraction value for Trabzon (41°N) and the highest solar fraction value for Adana (37°N) are obtained. Based on the economic analysis, the payback period of system is found to be about 25–35 years for Turkey. 相似文献
11.
In order to produce process heat for drying of agricultural, textile, marine products, heating of buildings and re-generating dehumidify agent, solar energy is one of the promising heat sources for meeting energy demand without putting adverse impact of environment. Hence it plays a key role for sustainable development. Solar energy is intermittent in nature and time dependent energy source. Owing to this nature, PCMs based thermal energy storage system can achieve the more popularity for solar energy based heating systems. The recent researches focused on the phase change materials (PCMs), as latent heat storage is more efficient than sensible heat storage. In this paper an attempt has been made to present holistic view of available solar air heater for different applications and their performance. 相似文献
12.
This work aims to evaluate the performance of a solar domestic hot water (SDHW) system including a latent storage material. The originality of our approach consists to place a composite made of compressed expanded natural graphite (CENG) and phase change material (PCM) directly inside a flat plate solar collector in order to replace the traditional copper-based solar absorber. According to this target, the study is composed of two steps: the composites preparation and characterization; and the analysis of the system to achieve optimal integration of the material in the process.The present paper is focused on the selection of the most promising composite to implement in the solar collector. In order to reach this objective, several composites based on CENG and various storage materials (paraffin, stearic acid, sodium acetate trihydrate and pentaglycerin) have been elaborated and characterized. The synthesis of all these measurements allowed us to select three composites whose characteristics match their integration into a solar thermal collector. 相似文献
13.
In recent years, thermal energy storage (TES) systems using phase change materials (PCM) have been widely studied and developed to be applied as solar energy storage units for residential heating and cooling. These systems performance is based on the latent heat due to PCM phase change, a high energy density that can be stored or released depending on the needs. PCM are normally encapsulated in containers, hence the compatibility of the container material with the PCM has to be considered in order to design a resistant container. Therefore, the main aim of this paper is to study the corrosion effects when putting in contact five selected metals (aluminium, copper, carbon steel, stainless steel 304 and stainless steel 316) with four different PCM (one inorganic mixture, one ester and two fatty acid eutectics) to be used in comfort building applications. Results showed corrosion on aluminium specimens. Hence caution must be taken when selecting it as an inorganic salt container. Despite copper has a corrosion rate range of 6–10 mg/cm2 yr in the two fatty acid formulations tested, it could be used as container. Stainless steel 316 and stainless steel 304 showed great corrosion resistance (0–1 mg/cm2 yr) and its use would totally be recommended with any of the studied PCM. 相似文献
14.
Energy consumed by heating, ventilation and air conditioning systems (HVAC) in buildings represents an important part of the global energy consumed in Europe. Thermal energy storage is considered as a promising technology to improve the energy efficiency of these systems, and if incorporated in the building envelope the energy demand can be reduced. Many studies are on applications of thermal energy storage in buildings, but few consider their integration in the building. The inclusion of thermal storage in a functional and constructive way could promote these systems in the commercial and residential building sector, as well as providing user-friendly tools to architects and engineers to help implementation at the design stage. The aim of this paper is to review and identify thermal storage building integrated systems and to classify them depending on the location of the thermal storage system. 相似文献
15.
An experimental solar assisted heat pump space heating system with a daily energy storage tank is designed and constructed, and its thermal performance is investigated. The heating system basically consists of flat plate solar collectors, a heat pump, a cylindrical storage tank, measuring units, and a heating room located in Gaziantep, Turkey (37.1°N). All measurements are automatically collected as a function of time by means of a measurement chain feeding to a data logger in combination with a PC. Hourly and daily variations of solar radiation, collector performance, coefficient of performance of the heat pump (COPHP), and that of the overall system (COPS) are calculated to evaluate the system performance. The effects of climatic conditions and certain operating parameters on the system performance parameters are investigated. COPHP is about 2.5 for a lower storage temperature at the end of a cloudy day and it is about 3.5 for a higher storage temperature at the end of a sunny day, and it fluctuates between these values in other times. Also, COPS turns out to be about 15–20% lower than COPHP. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
16.
Performance analysis of a latent heat storage system with phase change material for new designed solar collectors in greenhouse heating 总被引:5,自引:0,他引:5
The continuous increase in the level of greenhouse gas emissions and the rise in fuel prices are the main driving forces behind the efforts for more effectively utilize various sources of renewable energy. In many parts of the world, direct solar radiation is considered to be one of the most prospective sources of energy. In this study, the thermal performance of a phase change thermal storage unit is analyzed and discussed. The storage unit is a component of ten pieced solar air collectors heating system being developed for space heating of a greenhouse and charging of PCM. CaCl26H2O was used as PCM in thermal energy storage with a melting temperature of 29 °C. Hot air delivered by ten pieced solar air collector is passed through the PCM to charge the storage unit. The stored heat is utilized to heat ambient air before being admitted to a greenhouse. This study is based on experimental results of the PCM employed to analyze the transient thermal behavior of the storage unit during the charge and discharge periods. The proposed size of collectors integrated PCM provided about 18–23% of total daily thermal energy requirements of the greenhouse for 3–4 h, in comparison with the conventional heating device. 相似文献
17.
《Applied Thermal Engineering》2014,62(2):313-321
A validated computational fluid dynamics simulation tool is used to study the long-term performance of a centralized latent heat thermal energy storage system (LHTES). The LHTES system is integrated with a building mechanical ventilation system. Paraffin RT20 was used as a phase change material (PCM) and fins are used to enhance its performance.To reduce the computational time, artificial neural networks (ANN) was used to relate the relationships between the LHTES inputs and output parameters. Extensive CFD simulations were carried out to identify all the influential parameters for the development of ANN. They include phase change temperature range, air flow rate, the geometrical configuration of a LHTES system, fin size, and the unit's length. Further CFD simulations were carried out to provide sufficient data for proper training and testing of the ANN. The ANN model was used to predict the LHTES's outlet air-temperature. There was a good agreement between the ANN prediction and CFD model's prediction.The ANN model then was used to study the annual performance of a LHTES for application in Montreal. We found that the potential of use the centralized LHTES system to reduce the cooling load is high with a wider phase change temperature range. The centralized LHTES system contributes to reducing the cooling load from 21% to 36% when the length of the centralized LHTES system is increased from 500 to 650 mm at a flow rate of 1.5 m/s. 相似文献
18.
A method to determine stratification efficiency of thermal energy storage processes independently from storage heat losses 总被引:1,自引:0,他引:1
A new method for the calculation of a stratification efficiency of thermal energy storages based on the second law of thermodynamics is presented. The biasing influence of heat losses is studied theoretically and experimentally. Theoretically, it does not make a difference if the stratification efficiency is calculated based on entropy balances or based on exergy balances. In practice, however, exergy balances are less affected by measurement uncertainties, whereas entropy balances can not be recommended if measurement uncertainties are not corrected in a way that the energy balance of the storage process is in agreement with the first law of thermodynamics. A comparison of the stratification efficiencies obtained from experimental results of charging, standby, and discharging processes gives meaningful insights into the different mixing behaviors of a storage tank that is charged and discharged directly, and a tank-in-tank system whose outer tank is charged and the inner tank is discharged thereafter. The new method has a great potential for the comparison of the stratification efficiencies of thermal energy storages and storage components such as stratifying devices. 相似文献
19.
A state-of-the-art solar crop dryer was developed with thermal energy storage to maintain continuity of drying of herbs for their colour and flavour vulnerability. The dryer consists of flat plate solar collector, packed bed phase change energy storage, drying plenum with crop trays and natural ventilation system. Dryer is designed with a maximum collector area of 1.5 m2, six crop trays with an effective area of 0.50 × 0.75 m2, can hold 12 kg of fresh leafy herbs. The dryer is attached with a packed bed thermal energy storage having capacity of 50 kg phase change material (PCM). The drying system works in such a manner that phase change material stores the thermal energy during sun shine hours and releases the latent and sensible heat after sunset, thus dryer is effectively operative for next 5–6 h. The temperature in drying chamber was observed 6 °C higher than the ambient temperature after sunshine hours till the mid night during the month of June at Jodhpur. Economic performance of the dryer was analysed with return on capital and simple payback period as 0.65 and 1.57 year respectively on optimum cost of raw material and product sale price. 相似文献
20.
Analytical models have been put forward to predict the thermal performance of passive heating systems, which have previously been suggested. The systems consist of a water vessel for heat storage and a structure positioned on its outside wall, which act as a solar collector and a thermal insulation for the storage, respectively. Four different variations of structures have been considered and numerical calculations performed corresponding to the physical parameters of an earlier reported experimental study. The analysis is able to predict the experimental results fairly satisfactorily. 相似文献