Shen Y  Lee ML 《Analytical chemistry》1997,69(13):2541-2549
In this study, column efficiency in packed capillary column solvating gas chromatography (SGC) was investigated. Long (>3 m) fused silica capillaries with an inner diameter of 250 μm were packed with 10 and 15 μm spherical porous (300 ?) octadecyl bonded silica particles using a CO(2) slurry packing method. A 336 cm × 250 μm i.d. fused silica capillary containing 10 μm particles provided a total column efficiency of 264?000 plates (k = 0.41), corresponding to a reduced plate height of 1.27, using CO(2) as the mobile phase at a column inlet pressure of 260 atm. A minimum plate height of 12.7 μm and a maximum plate number per unit time of 813 plates/s were obtained using packed capillary SGC. Retention factors were dependent on the column inlet pressure but independent of the pressure gradient along the column. Gasoline and diesel samples were separated under SGC conditions, and the results were comparable to those obtained using typical open tubular column gas chromatography.  相似文献   

2.
The performance advantages of carrying out electrochemically modulated liquid chromatography (EMLC) at elevated temperatures and mobile-phase flow rates are investigated. EMLC has the unique ability to manipulate analyte retention and enhance separation efficiencies through changes in the potential applied to a conductive stationary phase. Operation of high-performance liquid chromatography systems at elevated column temperatures also provides pathways to improve chromatographic performance by enhancing analyte diffusivity and facilitating the use of higher mobile-phase flow rates than conventionally attainable. The results show that performing EMLC separations at elevated temperatures (e.g., 100 degrees C) reduces the analysis time of a mixture of aromatic sulfonates in a mixed mobile phase by more than a factor of 20. Moreover, use of higher operating temperatures enables the separation of this mixture with an entirely aqueous mobile phase in less than 2 min.  相似文献   

3.
The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).  相似文献   

4.
A new method is described that allows fast target analysis in multidimensional gas chromatography by using a microswitching valve between two GC columns, with cryogenic trapping and rapid re-injection of trapped solutes in the second dimension. The essence of the procedure is that heart-cut fractions from the first column (1D) can be selectively transferred to column 2 (2D), where a moveable cryogenic trap first focuses the transferred solute(s) at the head of the second column and then permits their facile rapid analysis on 2D. Since 2D is a short narrow-bore column, which exhibits very fast analysis (on the order of a few seconds elution), peak responses (heights) are significantly enhanced (by up to 40-fold). Additionally, by using a 2D phase of a selectivity different from that used for 1D, it is possible to also separate components that are not resolved on the first column and to increase the resolution for other compounds. The heart-cut valve isolates the section(s) of solutes of interest from the first column separation, and this provides a considerable simplification to the chromatogram-in addition to the separation and sensitivity advantages. By using this method, multidimensional gas chromatography with multiple heart-cuts can be completed within the same time as the primary column separation. Since the described method permits non-heart-cut fractions to be transferred to a monitor detector, normal detection of these fractions is still permitted. By modulation of the cryotrap, it is also possible to achieve comprehensive two-dimensional gas chromatography for the heart-cut fractions; however, only those compounds passed to the second, separation column, which passes through the cryotrap, will be subjected to GC x GC analysis. The technique and the various modes of operation are described in this paper.  相似文献   

5.
A new concept for liquid manipulation has been developed and implemented in surface-micromachined fluid channels. It is based on the surface tension directed injection of a gas into the liquid flow through micrometer-sized holes in the microchannel wall. The injected gas is directed to an exhaust by a cross-sectional asymmetry of the microchannel and thereby moves minute liquid volumes. Successful pumping experiments were performed with single stroke volumes of tens of picoliters at frequencies around 1 Hz. The minimum actuation pressure is 0.6 bar for a 2-microm channel height, in accordance with theoretical predictions.  相似文献   

6.
7.
8.
9.
The first part of this paper presents an experimental analysis of different hermetic scroll compressors using different methods of injection: the first one is without injection, the second one uses vapor injection and the third one liquid injection. The analysis reveals the influence of these methods on the compressor behavior. A simplified model of the scroll compressor is then proposed that takes into account not only the different internal processes but also the refrigerant injection. It assumes that the refrigerant mass flow rate is affected by a heating-up due to a uniform wall temperature. This fictitious wall is supposed to gain heat from the electromechanical losses and from the discharged gas and to loose heat to the suction and to the ambient. The compression step is considered isentropic up to the adapted pressure and then at constant volume until the discharge pressure. The model is able to compute variables of first importance like the mass flow rate, the electric power and the discharge temperature, as well as secondary variables as suction heating-up, discharge cooling-down, and ambient losses. The validation based on 45 experimental results shows excellent results.  相似文献   

10.
Microscale gas chromatography (μGC) is an emerging analytical technique for in situ analysis and on-site monitoring of volatile organic compounds (VOCs) in moderately complex mixtures. One of the critical subcomponents in a μGC system is a microfabricated preconcentrator (μ-preconcentrator), which enables detection of compounds existing in indoor/ambient air at low (~sub ppb) concentrations by enhancing their signals. The prevailing notion is that elution peak broadening and tailing phenomena resulting from undesirable conditions of a microfabricated separation column (μ-column) are the primary sources of poor chromatographic resolution. However, previous experimental results indicate that the resolution degradation still remains observed for a μ-column integrated with other μGC subcomponents even after setting optimal separation conditions. In this work, we obtain the evidence that the unoptimized μ-preconcentrator vapor release/injection performance significantly contributes to decrease the fidelity of μGC analysis using our state-of-the-art passive preconcentrator microdevice. The vapor release/injection performance is highly affected by the kinetics of the thermal desorption of compounds trapped in the microdevice. Decreasing the heating rate by 20% from the optimal rate of 90 °Cs(-1) causes a 340% increase in peak tailing as well as 70% peak broadening (30% peak height reduction) to the microscale vapor injection process.  相似文献   

11.
Gas chromatography-multiplex coherent Raman (GC-MCR) is a new tandem technique that can be used for the high-speed analysis of volatile mixtures. BTEX serves as a useful and challenging test sample because of the similarity in boiling point and spectroscopic properties of its constituents. The ability to spectroscopically resolve isomers (e.g., m-xylene and p-xylene) allows GC-MCR to sacrifice chromatographic resolution for speed. The result is the analysis of BTEX in less than 5 min, which is relatively fast compared with other tandem GC techniques.  相似文献   

12.
We report an online, optical injection interface for capillary zone electrophoresis (CZE) based upon photophysical activation of a caged, fluorogenic label covalently attached to the target analyte. This injection interface allows online analysis of biomolecular systems with high temporal resolution and high sensitivity. Samples are injected onto the separation capillary by photolysis of a caged-fluorescein label using the 351-364 nm irradiation of an Ar+ laser. Following injection, the sample is separated and detected via laser-induced fluorescence detection at 488 nm. Detection limits for online analysis of arginine, glutamic acid, and aspartic acid were less than 1 nM with separation times less than 5 s and separation efficiencies exceeding 1,000,000 plates/m. Rapid injection of proteins was demonstrated with migration times less than 500 ms and 0.5 nM detection limits. Online monitoring was performed with response times less than 20 s, suggesting the feasibility of this approach for online, in vivo analysis for a range of biologically relevant analytes.  相似文献   

13.
14.
We have developed a simple and accurate method for determining the complete positional isotopomer distribution of aspartate carbon atoms by gas chromatography/tandem mass spectrometry for (13)C-metabolic flux analysis. First, we screened tandem mass spectrometry (MS) spectra of the tert-butyldimethylsilyl (TBDMS) derivative of aspartate for daughter fragments with the necessary carbon atom fragmentations to fully resolve all 16 isotopomers of aspartate. Tandem MS scanning parameters were optimized for each daughter fragment, and the accuracy of tandem MS measurements were evaluated. We selected five accurate fragments that provided a redundant set of 47 labeling measurements to quantify the complete isotopomer distribution of aspartate by least-squares regression. The validity of the approach was demonstrated using six (13)C-labeled aspartate standards and natural aspartate.  相似文献   

15.
16.
建立了同时检测鱼肉中9种有机磷类农药残留的分散固相萃取-气相色谱联用方法。样品经乙腈进行提取,PSA、GCB和C18进行分散固相萃取净化,结合气相色谱法定性定量分析。添加样品的回收率为70.1%~80.4%,相对标准偏差在5.0%~10.2%,方法最低检出限为0.005~0.01 mg/kg。该法简便、准确,适用于鱼肉中9种有机磷农药残留量的检测。  相似文献   

17.
This work describes an approach to differential metabolomics that involves stable isotope labeling for relative quantification as part of sample analysis by two-dimensional gas chromatography/mass spectrometry (GCxGC/MS). The polar metabolome in control and experimental samples was extracted and differentially derivatized using isotopically light and heavy (D6) forms of the silylation reagent N-methyl-N-tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA). MTBSTFA derivatives are of much greater hydrolytic stability than the more common trimethylsilyl derivatives, thus diminishing the possibility of isotopomer scrambling during GC analysis. Subsequent to derivatization with MTBSTFA, differentially labeled samples were mixed and analyzed by GCxGC/MS. Metabolites were identified, and the isotope ratio of isotopomers was quantified. The method was tested using three classes of metabolites; amino acids, fatty acids, and organic acids. The relative concentration of isotopically labeled metabolites was determined by isotope ratio analysis. The accuracy and precision, respectively, in quantification of standard mixtures was 9.5 and 4.77% for the 16 amino acids, 9.7 and 2.83% for the mixture of 19 fatty acids, and 14 and 4.53% for the 20 organic acids. Suitability of the method for the examination of complex samples was demonstrated in analyses of the spiked blood serum samples. This differential isotope coding method proved to be an effective means to compare the concentration of metabolites between two samples simultaneously.  相似文献   

18.
A baseline correction method that uses basis set projection to estimate spectral backgrounds has been developed and applied to gas chromatography/mass spectrometry (GC/MS) data. An orthogonal basis was constructed using singular value decomposition (SVD) for each GC/MS two-way data object from a set of baseline mass spectra. A novel aspect of this baseline correction method is the regularization parameter that prevents overfitting that may produce negative peaks in the corrected mass spectra or ion chromatograms. The number of components in the basis, the regularization parameter, and the mass spectral range from which the spectra were sampled to construct the basis were optimized so that the projected difference resolution (PDR) or signal-to-noise ratio (SNR) was maximized. PDR is a metric similar to chromatographic resolution that indicates the separation of classes in a multivariate data space. This new baseline correction method was evaluated with two synthetic data sets and a real GC/MS data set. The prediction accuracies obtained by using the fuzzy rule-building expert system (FuRES) and partial least-squares-discriminant analysis (PLS-DA) as classifiers were compared and validated through bootstrapped Latin partition (BLP) between data before and after baseline correction. The results indicate that baseline correction of the two-way GC/MS data using the proposed methods resulted in a significant increase in average PDR values and prediction accuracies.  相似文献   

19.
Clean Technologies and Environmental Policy - It is well known that acetylene has a wide flammability and is readily available and low-cost non-crude oil derivative fuel. According to the property...  相似文献   

20.