首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Immobilized metal ion affinity chromatography (IMAC) is a useful method to selectively isolate and enrich phosphopeptides from a peptide mixture. Mass spectrometry is a very suitable method for exact molecular weight determination of IMAC-isolated phosphopeptides, due to its inherent high sensitivity. Even exact molecular weight determination, however, is not sufficient for identification of the phosphorylation site if more than one potential phosphorylation site is present on a peptide. The previous method of choice for sequencing the affinity-bound peptides was electrospray tandem mass spectrometry (ESI-MS/MS). This method required elution and salt removal prior to MS analysis of the peptides, which can lead to sample loss. Using a matrix-assisted laser desorption/ionization (MALDI) source coupled to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer with true MS/MS capabilities, direct sequencing of IMAC-enriched peptides has been performed on IMAC beads applied directly to the MALDI target. The utility of this new method has been demonstrated on a protein with unknown phosphorylation sites, where direct MALDI-MS/MS of the tryptic peptides bound to the IMAC beads resulted in the identification of two novel phosphopeptides. Using this technique, the phosphorylation site determination is unambiguous, even with a peptide containing four potentially phosphorylated residues. Direct analysis of phosphorylated peptides on IMAC beads does not adversely affect the high-mass accuracy of an orthogonal injection QqTOF mass spectrometer, making it a suitable technique for phosphoproteomics.  相似文献   

2.
Here we describe a new quadrupole Fourier transform ion cyclotron resonance hybrid mass spectrometer equipped with an intermediate-pressure MALDI ion source and demonstrate its suitability for "bottom-up" proteomics. The integration of a high-speed MALDI sample stage, a quadrupole analyzer, and a FT-ICR mass spectrometer together with a novel software user interface allows this instrument to perform high-throughput proteomics experiments. A set of linearly encoded stages allows sub-second positioning of any location on a microtiter-sized target with up to 1536 samples with micrometer precision in the source focus of the ion optics. Such precise control enables internal calibration for high mass accuracy MS and MS/MS spectra using separate calibrant and analyte regions on the target plate, avoiding ion suppression effects that would result from the spiking of calibrants into the sample. An elongated open cylindrical analyzer cell with trap plates allows trapping of ions from 1000 to 5000 m/z without notable mass discrimination. The instrument is highly sensitive, detecting less than 50 amol of angiotensin II and neurotensin in a microLC MALDI MS run under standard experimental conditions. The automated tandem MS of a reversed-phase separated bovine serum albumin digest demonstrated a successful identification for 27 peptides covering 45% of the sequence. An automated tandem MS experiment of a reversed-phase separated yeast cytosolic protein digest resulted in 226 identified peptides corresponding to 111 different proteins from 799 MS/MS attempts. The benefits of accurate mass measurements for data validation for such experiments are discussed.  相似文献   

3.
Protein phosphorylation is one of the most important known posttranslational modifications. Tandem mass spectrometry has become an important tool for mapping out the phosphorylation sites. However, when a peptide generated from the enzymatic or chemical digestion of a phosphoprotein is highly phosphorylated or contains many potential phosphorylation residues, phosphorylation site assignment becomes difficult. Separation and enrichment of phosphopeptides from a digest mixture is desirable and often a critical step for MS/MS-based site determination. In this work, we present a novel open tubular immobilized metal ion affinity chromatography (OT-IMAC) method, which is found to be more effective and reproducible for phosphopeptide enrichment, compared to a commonly used commercial product, Ziptip from Millipore. A strategy based on a combination of OT-IMAC, sequential dual-enzyme digestion, and matrix-assisted laser desorption/ionization (MALDI) quadrupole time-of-flight tandem mass spectrometry for phosphoprotein characterization is presented. It is shown that MALDI MS/MS with collision-induced dissociation can be very effective in generating fragment ion spectra containing rich structural information, which enables the identification of phosphorylation sites even from highly phosphorylated peptides. The applicability of this method for real world applications is demonstrated in the characterization and identification of phosphorylation sites of a Na(+)/H(+) exchanger fusion protein, His182, which was phosphorylated in vitro using the kinase Erk2.  相似文献   

4.
Young JB  Li L 《Analytical chemistry》2007,79(15):5927-5934
An automated off-line liquid chromatography-matrix-assisted laser desorption ionization (LC-MALDI) interface capable of coupling both capillary and microbore LC separations with MALDI mass spectrometry (MS) and tandem mass spectrometry (MS/MS) has been developed. The interface is a combination of two concepts: analyte concentration from heated hanging droplets and impulse-driven droplet deposition of LC fractions onto a MALDI sample plate. At room temperature the interface allows the coupling of capillary LC separations (i.e., flow rate of <5 microL/min) with MALDI MS. With heating, it can be used to combine microbore LC operated at a relatively high flow rate of up to 50 microL/min with MALDI MS. The collected fractions can be analyzed by MALDI MS and MS/MS instruments, such as time-of-flight (TOF) and quadrupole-TOF MS. Performance of the interface was examined using several peptide and protein standards. It was shown that, using MALDI-TOF MS, [GLU1]-fibrinopeptide B could be detected with a total injection amount of 5 fmol to microbore LC. Chromatographic performance was also monitored. A peak width of 12 s at half-height for [GLU1]-fibrinopeptide B showed no evidence of band broadening due to the interface. The ability of the interface to mitigate ion suppression was studied using a mixture of 100 fmol of [GLU1]-fibrinopeptide B and 10 pmol of cytochrome c tryptic digest. Although fully suppressed under direct MALDI conditions, LC-MALDI analysis was able to detect the 100 fmol peptide with 10 s fraction collection. Finally, the ability to inject relatively large sample amounts to improve detectability of low-abundance peptides was illustrated in the analysis of phosphopeptides from alpha-casein tryptic digests. A digest loaded on column to 2.4 microg and analyzed by LC-MALDI MS/MS resulted in 82% sequence coverage and detection of all nine phosphoserine residues. It is concluded that, being able to handle both high- and low-flow LC separations, the impulse-driven heated-droplet interface provides the flexibility to carry out MALDI analysis of peptides and proteins depending on the information sought after, analysis speed, and sample size.  相似文献   

5.
We describe the impact of advances in mass measurement accuracy, +/- 10 ppm (internally calibrated), on protein identification experiments. This capability was brought about by delayed extraction techniques used in conjunction with matrix-assisted laser desorption ionization (MALDI) on a reflectron time-of-flight (TOF) mass spectrometer. This work explores the advantage of using accurate mass measurement (and thus constraint on the possible elemental composition of components in a protein digest) in strategies for searching protein, gene, and EST databases that employ (a) mass values alone, (b) fragment-ion tagging derived from MS/MS spectra, and (c) de novo interpretation of MS/MS spectra. Significant improvement in the discriminating power of database searches has been found using only molecular weight values (i.e., measured mass) of > 10 peptide masses. When MALDI-TOF instruments are able to achieve the +/- 0.5-5 ppm mass accuracy necessary to distinguish peptide elemental compositions, it is possible to match homologous proteins having > 70% sequence identity to the protein being analyzed. The combination of a +/- 10 ppm measured parent mass of a single tryptic peptide and the near-complete amino acid (AA) composition information from immonium ions generated by MS/MS is capable of tagging a peptide in a database because only a few sequence permutations > 11 AA's in length for an AA composition can ever be found in a proteome. De novo interpretation of peptide MS/MS spectra may be accomplished by altering our MS-Tag program to replace an entire database with calculation of only the sequence permutations possible from the accurate parent mass and immonium ion limited AA compositions. A hybrid strategy is employed using de novo MS/MS interpretation followed by text-based sequence similarity searching of a database.  相似文献   

6.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a central tool for proteomic analysis, yet the singly protonated tryptic peptide ions produced by MALDI are significantly more difficult to dissociate for tandem mass spectrometry (MS/MS) than the corresponding multiply protonated ions. In order to overcome this limitation, current proteomic approaches using MALDI-MS/MS involve high-energy collision-induced dissociation (CID). Unfortunately, the use of high-energy CID complicates product ion spectra with a significant proportion of irrelevant fragments while also reducing mass accuracy and mass resolution. In order to address the lack of a high-resolution, high mass accuracy MALDI-MS/MS platform for proteomics, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and a recently developed MS/MS technique termed CIRCA (for combination of infrared and collisional activation) have been applied to proteomic analysis. Here, CIRCA is shown to be suitable for dissociating singly protonated tryptic peptides, providing greater sequence coverage than either CID or infrared multiphoton dissociation (IRMPD) alone. Furthermore, the CIRCA fragmentation spectra are of sufficient quality to allow protein identification based on the MS/MS spectra alone or in concert with the peptide mass fingerprint (PMF). This is accomplished without compromising mass accuracy or mass resolution. As a result, CIRCA serves to enable MALDI-FTICR-MS/MS for high-performance proteomics experiments.  相似文献   

7.
A statistical model for identifying proteins by tandem mass spectrometry   总被引:51,自引:0,他引:51  
A statistical model is presented for computing probabilities that proteins are present in a sample on the basis of peptides assigned to tandem mass (MS/MS) spectra acquired from a proteolytic digest of the sample. Peptides that correspond to more than a single protein in the sequence database are apportioned among all corresponding proteins, and a minimal protein list sufficient to account for the observed peptide assignments is derived using the expectation-maximization algorithm. Using peptide assignments to spectra generated from a sample of 18 purified proteins, as well as complex H. influenzae and Halobacterium samples, the model is shown to produce probabilities that are accurate and have high power to discriminate correct from incorrect protein identifications. This method allows filtering of large-scale proteomics data sets with predictable sensitivity and false positive identification error rates. Fast, consistent, and transparent, it provides a standard for publishing large-scale protein identification data sets in the literature and for comparing the results obtained from different experiments.  相似文献   

8.
A very high pressure liquid chromatography (VHPLC) system was constructed by modifying a commercially available pump in order to achieve pressures in excess of 1,200 bar (17,500 psi). A computer-controlled low-pressure mixer was used to generate solvent gradients. Protein digests were rapidly analyzed by reversed-phase VHPLC with linear solvent gradients coupled to either a tandem mass spectrometer using electrospray ionization or a UV/visible detector. The separations were performed at pressures ranging from 790 (11,500 psi) to 930 bar (13,500 psi) in 22-cm-long capillary columns packed with C18-modified 1.5-microm nonporous silica particles. A digest of bovine serum albumin (BSA) was analyzed by the VHPLC system connected to a mass spectrometer in MS mode. An analysis of 12.5 fmol of sample gave signal-to-noise ratios of tryptic peaks greater than 10:1 in the base peak plot mass chromatogram. This system was also used to analyze a proteolytic digest of a rat liver protein excised from a 2-D gel separation of a liver tissue lysate. For this analysis, the mass spectrometer was set up to perform data-dependent scanning (automated switching from MS mode to MS/MS mode when a peak was detected) for peptide sequencing and protein identification by database searching. The results of this analysis are compared to an analysis performed on the same sample using the nanoelectrospray-MS/MS technique. Though both techniques were able to identify the unknown protein, the VHPLC method gave twice as many sequenced peptides as nanoelectrospray and improved the signal-to-noise ratio of the spectra by at least a factor of 10. Direct comparisons with nanoelectrospray for MS and MS/MS data acquisition from a BSA digest were made. These comparisons show enhancements of greater than 20-fold for VHPLC over nanoelectrospray. In addition, the VHPLC/MS/MS data acquisition was accomplished in an automated manner.  相似文献   

9.
A mini ball mill (MBM) solvent-free matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) method allows for the analysis of bacteriorhodopsin (BR), an integral membrane protein that previously presented special analytical problems. For well-defined signals in the molecular ion region of the analytes, a desalting procedure of the MBM sample directly on the MALDI target plate was used to reduce adduction by sodium and other cations that are normally attendant with hydrophobic peptides and proteins as a result of the sample preparation procedure. Mass analysis of the intact hydrophobic protein and the few hydrophobic and hydrophilic tryptic peptides available in the digest is demonstrated with this robust new approach. MS and MS/MS spectra of BR tryptic peptides and intact protein were generally superior to the traditional solvent-based method using the desalted "dry" MALDI preparation procedure. The solvent-free method expands the range of peptides that can be effectively analyzed by MALDI-MS to those that are hydrophobic and solubility-limited.  相似文献   

10.
A pattern recognition algorithm called SALSA (scoring algorithm for spectral analysis) has been developed to rapidly screen large numbers of peptide MS-MS spectra for fragmentation characteristics indicative of specific peptide modifications. The algorithm facilitates sensitive and specific detection of modified peptides at low abundance in an enzymatic protein digest. SALSA can simultaneously score multiple user-specified search criteria, including product ions, neutral losses, charged losses, and ion pairs that are diagnostic of specific peptide modifications. Application of SALSA to the detection of peptide adducts of the electrophiles dehydromonocrotaline, benzoquinone, and iodoacetic acid permitted their detection in a complex tryptic peptide digest mixture. SALSA provides superior detection of adducted peptides compared to conventional tandem MS precursor ion or neutral loss scans.  相似文献   

11.
A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic and hydrophilic polypeptides in mixtures, thereby reducing the complexity of mass spectra obtained by MALDI MS. The LLE technique was optimized for rapid and sensitive in situ (on-target) sample preparation for MALDI MS analysis of proteins and peptides at low-picomole and subpicomole levels. Addition of MALDI matrix to the organic solvent enhanced the efficiency of the LLE-MALDI MS method for analysis of hydrophobic peptides and proteins. LLE-MALDI MS enabled the detection of the hydrophobic membrane protein bacteriorhodopsin as a component in a simple protein mixture. Peptide mixtures containing phosphorylated, glycosylated, or acylated peptides were successfully separated and analyzed by the in situ LLE-MALDI MS technique and demonstrate the potential of this method for enhanced separation and structural analysis of posttranslationally modified peptides in proteomics research.  相似文献   

12.
Protein ubiquitination plays an important role in the degradation and other functional regulation of cellular proteins in organisms ranging from yeasts to mammals. Trypsin digestion of ubiquitin conjugated proteins produces diglycine branched peptides in which the C-terminal Gly-Gly fragment of ubiquitin is attached to the epsilon-amino group of a modified lysine residue within the peptide. This provides a platform for mapping ubiquitination sites using mass spectrometry. Here we report the development of a novel strategy for determining posttraslational protein ubiquitination based on the N-terminal sulfonation of diglycine branched peptides. In contrast to conventional tandem MS spectra of native tryptic peptides, MALDI MS/MS analysis of a sulfonated tryptic peptide containing a diglycine branch generates a unique spectrum composed of a signature portion and a sequence portion. The signature portion of the spectrum consists of several intense ions resulting from the elimination of the tags, the N-terminal residues at the peptide and the branch, and their combination. This unique ion distribution pattern can distinguish ubiquitination modificatons from others and can identify the first N-terminal residues of the peptides as well. The sequence portion consists of an exclusive series of y-type ions and y' ions (differing by the loss of one glycine residue from the sulfonated diglycine branch) that can directly reveal the amino acid sequence of the peptide and the precise location of the ubiquitination site. The technique is demonstrated for a series of synthetic peptides and is validated by a model protein, tetraubiquitin. Our results show that the MALDI MS/MS analysis of sulfonated tryptic peptides can provide a highly effective method for the determination of ubiquitination substrates, ubiquitination sites on protein targets, and modification sites on ubiquitins themselves.  相似文献   

13.
A database of 5500 unique peptide tandem mass spectra acquired in an ion trap mass spectrometer was assembled for peptides derived from proteins digested with trypsin. Peptides were identified initially from their tandem mass spectra by the SEQUEST algorithm and subsequently validated manually. Two different statistical methods were used to identify sequence-dependent fragmentation patterns that could be used to improve fragmentation models incorporated into current peptide sequencing and database search algorithms. The currently accepted "mobile proton" model was expanded to derive a new classification scheme for peptide mass spectra, the "relative proton mobility" scale, which considers peptide ion charge state and amino acid composition to categorize peptide mass spectra into peptide ions containing "nonmobile", "partially mobile", or "mobile" protons. Quantitation of amide bond fragmentation, both N- and C-terminal to any given amino acid, as well as the positional effect of an amino acid in a peptide and peptide length on such fragmentation, has been determined. Peptide bond cleavage propensities, both positive (i.e., enhanced) and negative (i.e., suppressed), were determined and ranked in order of their cleavage preferences as primary, secondary, or tertiary cleavage effects. For example, primary positive cleavage effects were observed for Xaa-Pro and Asp-Xaa bond cleavage for mobile and nonmobile peptide ion categories, respectively. We also report specific pairwise interactions (e.g., Asn-Gly) that result in enhanced amide bond cleavages analogous to those observed in solution-phase chemistry. Peptides classified as nonmobile gave low or insignificant scores, below reported MS/MS score thresholds (cutoff filters), indicating that incorporation of the relative proton mobility scale classification would lead to improvements in current MS/MS scoring functions.  相似文献   

14.
We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.  相似文献   

15.
The coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) with Fourier transform mass spectrometry (FTMS) is described, and its significance for the high-resolution analysis of complex peptide mixtures is demonstrated. High kinetic energy and extensive metastable decay characteristic of ions generated by vacuum MALDI have been known to constitute a possible obstacle to high-resolution analysis by FTMS. Since the initial coupling of laser desorption techniques with FTMS was realized two decades ago, several different solutions have been proposed to control the energy of the ions and fulfill the promise of high sensitivity and high resolution offered by this analytical method. Initial results obtained on quadrupole time-of-flight and ion trap analyzers have shown that ions generated by MALDI at atmospheric pressure are intrinsically less energetic than those provided by vacuum MALDI. Our report indicates that this characteristic is particularly beneficial for FTMS applications in which a sharp reduction of metastable decay can make larger ion currents available for detection and possible tandem experiments. In our hands, AP MALDI-FTMS has enabled the analysis of complex peptide mixtures with resolution and accuracy comparable to those obtained by analogous electrospray ionization-FTMS experiments, with no evidence of either metastable decomposition or significant formation of matrix adducts. Analysis of a trypsin digest of bovine serum albumin provided signal-to-noise ratios and limits of detection similar to those obtained by ion trap analyzers, but with unmatched resolution and accuracy. AP MALDI has been shown to provide stable precursor ions in amounts that allowed for informative tandem experiments. Finally, the potential of AP MALDI-FTMS for the high-resolution screening of complex mixtures was demonstrated by the analysis of isobaric peptides differing in mass by less than 0.04 Da.  相似文献   

16.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

17.
Comparing the relative abundance of each protein present in two or more complex samples can be accomplished using isotope-coded tags incorporated at the peptide level. Here we describe a chemical labeling strategy for the incorporation of a single isotope label per peptide, which is completely sequence-independent so that it potentially labels every peptide from a protein including those containing posttranslational modifications. It is based on a gentle chemical labeling strategy that specifically labels the N-terminus of all peptides in a digested sample with either a d5- or d0-propionyl group. Lysine side chains are blocked by guanidination prior to N-terminal labeling to prevent the incorporation of multiple labels. In this paper, we describe the optimization of this N-terminal isotopic tagging strategy and validate its use for peptide-based protein abundance measurements with a 10-protein standard mixture. Using a results-driven strategy, which targets proteins for identification based on MALDI TOF-MS analysis of isotopically labeled peptide pairs, we also show that this labeling strategy can detect a small number of differentially expressed proteins in a mixture as complex as a yeast cell lysate. Only peptides that show a difference in relative abundance are targeted for identification by tandem MS. Despite the fact that many peptides are quantitated, only those few showing a difference in abundance are targeted for protein identification. Proteins are identified by either targeted LC-ES MS/MS or MALDI TOF/TOF. Identifications can be accomplished equally well by either technique on the basis of multiple peptides. This increases the confidence level for both identification and quantitation. The merits of ES MS/MS or MALDI MS/MS for protein identification in a results-driven strategy are discussed.  相似文献   

18.
An atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) source coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT ICR MS) under UV laser and solid matrix conditions has been demonstrated to analyze a variety of labile oligosaccharides including O-linked and N-linked complex glycans released from glycoproteins. Spectra were acquired by both AP MALDI and vacuum MALDI and directly compared. The results presented here confirm that AP MALDI can generate significantly less energetic ions than vacuum MALDI and is able to produce the intact molecular ions with little or no fragmentation in both positive and negative ion mode analyses. Under certain conditions, noncovalent complexes of sialylated oligosaccharides were observed. The sensitivity attainable by AP MALDI was found to be comparable to conventional MALDI, and tandem mass spectrometry of oligosaccharides ionized by AP MALDI was shown to allow detailed structural analysis. Analysis of N-glycan mixtures derived from human fibrinogen further demonstrated that AP MALDI-FT ICR MS is ideal for the study of complex glycan samples as it provides high-accuracy, high-resolution mass analysis with no difficulty in distinguishing sample constituents from fragment ions.  相似文献   

19.
This paper presents application of sequential enhanced data processing procedures to high-resolution tandem mass spectra for identification of peptides using the Mascot database search algorithm. A strategy for (1) selection of fragment ion peaks from MS/MS spectra, (2) utilization of improved mass accuracy of the precursor ions, and (3) wavelet denoising of the mass spectra prior to fragment ion selection have been developed. The number of peptide identifications obtained using the enhanced processing was then compared with that obtained using software provided by the instrument manufacturer. Approximately 9000 MS/MS spectra acquired by the Applied Biosystems 4700 TOF/TOF MS instrument were used as a model data set. After application of the new processing, an increase of 33% unique peptides and 22% protein identifications with at least two unique peptides were found. The influence of the processing on the percentage of false positives, estimated by searching against a randomized database, was estimated to increase false positive identifications from 2.7 to 3.9%, which was still below the 5% error rate specified in the Mascot search. These data processing approaches increase the amount of information that can be extracted from LC-MS analysis without the necessity of additional experiments.  相似文献   

20.
MALDI imaging allows the creation of a "molecular image" of a tissue slice. This image is reconstructed from the ion abundances in spectra obtained while rastering the laser over the tissue. These images can then be correlated with tissue histology to detect potential biomarkers of, for example, aberrant cell types. MALDI, however, is known to have problems with ion suppression, making it difficult to correlate measured ion abundance with concentration. It would be advantageous to have a method which could provide more accurate protein concentration measurements, particularly for screening applications or for precise comparisons between samples. In this paper, we report the development of a novel MALDI imaging method for the localization and accurate quantitation of proteins in tissues. This method involves optimization of in situ tryptic digestion, followed by reproducible and uniform deposition of an isotopically labeled standard peptide from a target protein onto the tissue, using an aerosol-generating device. Data is acquired by MALDI multiple reaction monitoring (MRM) mass spectrometry (MS), and accurate peptide quantitation is determined from the ratio of MRM transitions for the endogenous unlabeled proteolytic peptides to the corresponding transitions from the applied isotopically labeled standard peptides. In a parallel experiment, the quantity of the labeled peptide applied to the tissue was determined using a standard curve generated from MALDI time-of-flight (TOF) MS data. This external calibration curve was then used to determine the quantity of endogenous peptide in a given area. All standard curves generate by this method had coefficients of determination greater than 0.97. These proof-of-concept experiments using MALDI MRM-based imaging show the feasibility for the precise and accurate quantitation of tissue protein concentrations over 2 orders of magnitude, while maintaining the spatial localization information for the proteins.  相似文献   