 共查询到20条相似文献,搜索用时 62 毫秒
1.
This paper presents a control for a three phase five-level neutral clamped inverter (NPC) for grid connected PV system. The maximum power point tracking (MPPT) is capable of extracting maximum power from the PV array connected to each DC link voltage level. The MPPT algorithm is solved by fuzzy logic controller. The fuzzy MPPT is integrated with the inverter so that a DC–DC converter is not needed and the output shows accurate and fast response. A digital PI current control algorithm is used to remain the current injected into the grid sinusoidal and to achieve high dynamic performance with low total harmonic distortion (THD). The validity of the system is verified through MATLAB/Simulink and the results are compared with three phase three-level grid connected NPC inverter in terms of THD.  相似文献   

2.
Fault ride through of fully rated converter wind turbines in an offshore wind farm connected to onshore network via either high voltage AC (HVAC) or high voltage DC (HVDC) transmission is described. Control of the generators and the grid side converters is shown using vector control techniques. A de-loading scheme was used to protect the wind turbine DC link capacitors from over voltage. How de-loading of each generator aids the fault ride through of the wind farm connected through HVAC transmission is demonstrated. The voltage recovery of the AC network during the fault was enhanced by increasing the reactive power current of the wind turbine grid side converter. A practical fault ride through protection scheme for a wind farm connected through an HVDC link is to employ a chopper circuit on the HVDC link. Two alternatives to this approach are also discussed. The first involves de-loading the wind farm on detection of the fault, which requires communication of the fault condition to each wind turbine of the wind farm. The second scheme avoids this complex communication requirement by transferring the fault condition via control of the HVDC link to the offshore converter. The fault performances of the three schemes are simulated and the results were used to assess their respective capabilities.  相似文献   

3.
针对基于储能的并网永磁直驱风力发电系统的运行特点,提出了一种对电网侧变换器的模糊功率控制策略,当电网发生电压瞬时跌落时使电网侧变换器运行在模糊功率控制模式,依据电网电压跌落深度及风机输出功率大小通过模糊控制器来确定发出无功电流的大小,从而使风电系统能够适度地向电网提供一定的无功功率来支撑电网电压。仿真结果表明,所提出的控制策略正确、有效。  相似文献   

4.
Emphasis in this article is on the design of a co‐ordinated voltage control strategy for doubly fed induction generator (DFIG) wind turbines that enhances their capability to provide grid support during grid faults. In contrast to its very good performance in normal operation, the DFIG wind turbine concept is quite sensitive to grid faults and requires special power converter protection. The fault ride‐through and grid support capabilities of the DFIG address therefore primarily the design of DFIG wind turbine control with special focus on power converter protection and voltage control issues. A voltage control strategy is designed and implemented in this article, based on the idea that both converters of the DFIG (i.e. rotor‐side converter and grid‐side converter) participate in the grid voltage control in a co‐ordinated manner. By default the grid voltage is controlled by the rotor‐side converter as long as it is not blocked by the protection system, otherwise the grid‐side converter takes over the voltage control. Moreover, the article presents a DFIG wind farm model equipped with a grid fault protection system and the described co‐ordinated voltage control. The whole DFIG wind farm model is implemented in the power system simulation toolbox PowerFactory DIgSILENT. The DFIG wind farm ride‐through capability and contribution to voltage control in the power system are assessed and discussed by means of simulations with the use of a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk. The simulation results show how a DFIG wind farm equipped with voltage control can help a nearby active stall wind farm to ride through a grid fault, without implementation of any additional ride‐through control strategy in the active stall wind farm. Copyright © 2006 John Wiley &Sons, Ltd.  相似文献   

5.
针对风电电压波动的问题,文章基于风电机组无功裕度预测,提出了一种风电场无功分层控制策略.该策略首先以并网点电压偏差和线路有功损耗最小为目标,使用二次规划算法在线实时求解最优并网电压,进而求解风电场无功参考值;其次,采用EWT-LSSVM预测算法进行风电功率预测,并提出预测功率校正方法实时修正预测功率,精确求解风电机组的...  相似文献   

6.
This paper concentrates on the design and control of a three-level grid side converter (GSC) for direct drive high power wind turbines. The three-level, neutral point clamped (NPC) topology was investigated. The proposed control scheme, based on vector current control, offers very satisfying performances regarding to structure stability and grid connection requirements (GCR). In order to have an accurate evaluation of grid voltage source, two grid synchronization methods are developed and their performances are compared. The GSC performances are evaluated under both normal and grid fault conditions. Simulation results show that stability is maintained during voltage dips and that the proposed direct drive wind turbine satisfies completely GCR.  相似文献   

7.
Offshore wind power plants (WPPs) built near each other but far from shore usually connect to the main grid by a common high‐voltage DC (HVDC) transmission system. In the resulting decoupled offshore grid, the wind turbine converters and the high‐voltage DC voltage‐source converter share the ability to inject or absorb reactive power. The overall reactive power control dispatch influences the power flows in the grid and hence the associated power losses. This paper evaluates the respective power losses in HVDC‐connected WPP clusters when applying 5 different reactive power control strategies. The case study is made for a 1.2‐GW–rated cluster comprising 3 WPP and is implemented in a combined load flow and converter loss model. A large set of feasible operating points for the system is analyzed for each strategy. The results show that a selection of simulations with equal wind speeds is sufficient for the annual energy production comparison. It is found that the continuous operation of the WPPs with unity power factor has a superior performance with low communication requirements compared with the other conventional strategies. The optimization‐based strategy, which is developed in this article, allows a further reduction of losses mainly because of the higher offshore grid voltage level imposed by the high‐voltage DC voltage‐source converter. Reactive power control in HVDC‐connected WPP clusters change significantly the overall power losses of the system, which depend rather on the total sum of the injected active power than on the variance of wind speeds inside the cluster.  相似文献   

8.
This paper describes the modelling and control system of a direct-drive PMSG wind turbine for effective active and reactive power generation control and voltage control at the grid connection point. This study focuses on the maximum power capability of the wind turbine, which is limited by its generator and power converter. The ability of this model and control strategy are assessed by means of simulations and discussed at length. The results of our study show that a PMSG wind turbine is able to actively participate in grid operation because it can independently control active and reactive power production (operating as a PQ node) or the active power and voltage at the connection node (operating as a PV node).  相似文献   

9.
针对海上风电多端柔性直流(VSC-MTDC)并网系统,重点研究风电VSC-MTDC对岸上电网调频功能.通过建立详细风电场、换流站和电网模型,提出一种适用于海上风电VSC-MTDC并网系统动态频率调节方法,即改进斜率控制.整个海上风电场VSC-MTDC加入改进斜率控制后,可使有功功率在若干岸上换流站之间合理分配,从而确保...  相似文献   

10.
As a result of the increasing wind power penetration on power systems, the wind farms are today required to participate actively in grid operation by an appropriate generation control. This paper presents a comparative study on the performance of three control strategies for DFIG wind turbines. The study focuses on the regulation of the active and reactive power to a set point ordered by the wind farm control system. Two of them (control systems 1 and 2) are based on existing strategies, whereas the third control system (control system 3) presents a novel control strategy, which is actually a variation of the control system 2. The control strategies are evaluated through simulations of DFIG wind turbines, under normal operating conditions, integrated in a wind farm with centralized control system controlling the wind farm generation at the connection point and computing the power reference for each wind turbine according to a proportional distribution of the available power. The three control systems present similar performance when they operate with power optimization and power limitation strategies. However, the control system 3 with down power regulation presents a better response with respect to the reactive power production, achieving a higher available reactive power as compared with the other two. This is a very important aspect to maintain an appropriate voltage control at the wind farm bus.  相似文献   

11.
This paper will describe the possibilities of coordinated control and management for different wind farm concepts to guarantee that operational set points of active and reactive power, specified by the Spanish transmission system operator (TSO), are reached. This coordinated control has been designed and implemented by a hierarchical and robust control structured from a central control level to each wind farm control board and finally to an individual wind turbine level. This article will demonstrate that both technologies, fixed and variable speed based wind farms can contribute to power and voltage control. In particular, this paper will deal with the use of under-load tap changing transformers in the point of common coupling of the wind farm with the grid, and the reactive power compensation by means of convectional mechanical switched capacitors enhancing the integration of the fixed speed wind farms in the power system.  相似文献   

12.
In this paper, it is reported that energy capacitor system (ECS), which combines power electronic devices and electric double‐layer capacitor, can significantly decrease voltage and power fluctuations of grid‐connected fixed‐speed wind generator. The proper selection of wind farm output power reference is still a problem for smoothing the wind farm output power. This paper proposes exponential moving average to generate the reference output power of a grid‐connected wind farm. The objective of the control system is to follow the line power reference by absorbing or providing real power to or from the ECS. Moreover, the necessary reactive power can also be supplied to keep the wind farm terminal voltage at the desired reference level. Real wind speed data were used in the simulation analyses, which validate the effectiveness of the proposed control strategy. Simulation results clearly show that our proposed ECS can be suitable for wind power application. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

13.
双馈感应式风力发电系统低电压运行特性研究   总被引:2,自引:1,他引:1  
双馈感应发电机(DFIG)具有有功、无功功率独立调节能力及励磁变频器所需容量小等优点,在风力发电系统中得到越来越广泛的应用。但正是励磁变频器的过流能力限制使得其对电网故障非常敏感,电网故障下DFIG风电机组的控制能力受到限制。当前国外大多数风电并网标准都要求风力发电机在电网电压跌落的情况下不能从电网中解列,以便在故障后电网恢复过程中提供功率支持,避免发生后续更为严重的电网故障,这即是对风电机组低电压穿越能力的要求。为了保护变流器和对电网提供支撑,需要研制一种能够在电网故障发生时为故障电流进行旁路的设备——Crowbar电路。针对Crowbar的电流旁路装置进行了研究,说明Crowbar电路具有抑制转子浪涌电流和保护直流母线的作用,并在小功率平台上进行了试验,证明了这种设备对于提高DFIG系统的LVRT能力具有重要的作用。  相似文献   

14.
Emphasis in this paper is on the fault ride-through and grid support capabilities of multi-pole permanent magnet synchronous generator (PMSG) wind turbines with a full-scale frequency converter. These wind turbines are announced to be very attractive, especially for large offshore wind farms. A control strategy is presented, which enhances the fault ride-through and voltage support capability of such wind turbines during grid faults. Its design has special focus on power converters' protection and voltage control aspects. The performance of the presented control strategy is assessed and discussed by means of simulations with the use of a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk. The simulation results show how a PMSG wind farm equipped with an additional voltage control can help a nearby active stall wind farm to ride through a grid fault, without implementation of any additional ride-through control strategy in the active stall wind farm.  相似文献   

15.
This paper is on a wind energy conversion system simulation of a transient analysis due to a blade pitch control malfunction. The aim of the transient analysis is the study of the behavior of a back-to-back multiple point clamped five-level full-power converter implemented in a wind energy conversion system equipped with a permanent magnet synchronous generator. An alternate current link connects the system to the grid. The drive train is modeled by a three-mass model in order to simulate the dynamic effect of the wind on the tower. The control strategy is based on fractional-order control. Unbalance voltages in the DC-link capacitors are lessen due to the control strategy, balancing the capacitor banks voltages by a selection of the output voltage vectors. Simulation studies are carried out to evaluate not only the system behavior, but also the quality of the energy injected into the electric grid.  相似文献   

16.
In this paper a grid connected photovoltaic (PV) system is presented. The grid integration of the PV system is carried out via a three phase three level neutral point clamped (NPC) inverter. To control the inverter a modified version of voltage oriented control (VOC) method and the space vector pulse width modulation (SVPWM) technique have been applied. With the proposed modification the PV system operates as a shunt active power filter (SAPF), a reactive power compensator, and a load’s current balancer simultaneously. In this way the PV system operates more efficiently compared to the conventional PV systems and offers ancillary services to electric power system. The effectiveness of the proposed control scheme is established through simulation results with Matlab/Simulink in steady state and transient response of the electric power distribution system.  相似文献   

17.
This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed wind power generation. Appropriate state space model of the DFIG is deduced. An original control strategy based on a variable structure control theory, also called sliding mode control, is applied to achieve the control of the active and reactive power exchanged between the stator of the DFIG and the grid. A proportional-integral-(PI) controller is used to keep the DC-link voltage constant for a back-to-back PWM converter. Simulations are conducted for validation of the digital controller operation using Matlab/Simulink software.  相似文献   

18.
Grid‐connected photo voltaic (PV) systems are being developed very fast and systems from a few kW to tenths of a MW are now in operation. As an important source of distributed generation (DS) the PV systems need to comply with a series of standard requirements in order to ensure the safety and the seamless transfer of the electrical energy to the grid. Multilevel voltage source converters (VSC) is a heart of the PV system and are emerging as an important power converter options for low, medium, and high‐power applications. These VSCs have bought numerous advantages, especially in renewable energy systems such as PV and wind energy systems. In this article, several topologies of VSCs, which brings together some concepts from traditional converters and multi‐level converters, are presented. Also, several control strategies for controlling current, voltage, active power and reactive power have also been reviewed. Various topologies with their technical aspects have been reviewed and the best suitable topology and control scheme for grid connected PV and wind energy systems has been suggested. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
A control strategy for compensating AC network voltage unbalance using doubly fed induction generator (DFIG)-based wind farms is presented. A complete DFIG dynamic model containing both the rotor and grid side converters is used to accurately describe the average and ripple components of active/reactive power, electromagnetic torque and DC bus voltage, under unbalanced conditions. The principle of using DFIG systems to compensate grid voltage unbalance by injecting negative sequence current into the AC system is described. The injected negative sequence current can be provided by either the grid side or the rotor side converters. Various methods for coordinating these two converters are discussed and their respective impacts on power and torque oscillations are described. The validity of the proposed control strategy is demonstrated by simulations on a 30 MW DFIG-based wind farm using Matlab/Simulink during 2 and 4% voltage unbalances. The proposed compensation strategy can not only ensure reliable operation of the wind generators by restricting torque, DC link voltage and power oscillations, but also enable DFIG-based wind farms to contribute to rebalancing the connected network.  相似文献   

20.
王凯  闫广新 《电力与能源》2012,(1):55-58,61
采用超导储能(SMES)可以改善风电场并网运行的稳定性,针对风电系统中出现的联络线短路故障和风电场的风速扰动,提出利用超导储能安装点的电压偏差信号作为超导储能有功控制器的控制策略。为了验证这种策略的有效性,建立了风电机组和超导储能装置的数学模型,并利用MATLAB/Simulink软件搭建了风电场接入电网后的仿真模型。仿真结果表明,采用该控制策略不仅可以在网络故障后有效地提高风电场的稳定性,而且能够在快速的风速扰动下平滑风电场的功率输出,降低风电场对电网的冲击。  相似文献   