首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liquid chromatography-pneumatically assisted electrospray mass spectrometry with negative ionization has been used for the determination of acidic herbicides in ground water. Eighteen pesticides or pesticide degradation products belonging to several different groups of acidic herbicides (phenoxy acids, sulfonylureas, phenols, etc.) were covered in the study. Optimization of electrospray inlet conditions is described as well as results from investigations of the linearity of the detector response. Conditions for tandem mass spectrometry (MS-MS) detection of characteristic daughter ions formed by collision-induced dissociation (CID) of the parent ion are described and a comparison of obtainable instrument detection limits by single MS and MS-MS was made. Detection limits using MS in the selected ion monitoring (SIM) mode were generally in the order of 1 microgram/l or below, whereas detection limits were three-four times higher using MS-MS detection. A principle of analysis is proposed based on single quadrupole MS as a method for quantitative determination followed by verification of positive findings by CID MS-MS. Application of the method for detecting acidic herbicides residues in a "real-world" ground water sample is demonstrated.  相似文献   

2.
Three trypsin inhibitors from Sicyos australis, have been isolated, purified and sequenced. Following protein extraction with ammonium sulphate, the mixture of inhibitors was separated from other proteins by trypsin-affinity chromatography. Subsequent purification of the individual inhibitors was accomplished by reversed-phase HPLC. The primary structures of each inhibitor were elucidated by a combination of protein sequencing and electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS-MS) on both the untreated and the reduced and S-carboxymethylated inhibitors. All three inhibitors show extensive sequence similarity with inhibitors from cultivated Cucurbitaceae species, although there are a number of novel residues present. One of the inhibitors has a blocked N-terminus (pyroglutamic acid) and the use of MS-MS was crucial to the elucidation of its primary structure. ESI-MS was further used to characterize the non-covalent complex between one of the inhibitors and trypsin.  相似文献   

3.
Pharmacokinetic studies of molsidomine require a sensitive analytical method to allow the determination of concentrations of this compound and its active metabolite 3-morpholinosydnonimine (Sin-1) in the ng/ml range in plasma. The method developed is based on on-line LC-MS-MS using pneumatically assisted electrospray ionisation as an interface, preceded by off-line solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (automated sample preparation with extraction cartridges; ASPEC system). The DEC, filled with phenyl-modified silica, was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol containing formic acid (0.2%) and water. The liquid chromatographic separation of molsidomine and Sin-1 was achieved on an RP-8 stationary phase (5 microns). The mobile phase was a mixture of methanol-water-formic acid (65:35:0.1, v/v/v). The HPLC system was then coupled to a MS-MS system with an atmospheric pressure ionisation interface in the positive ion mode. The chromatographed analytes were detected in the multiple reaction monitoring mode. The MS-MS ion transitions monitored were (m/z) 243-->86 for molsidomine and 171-->86 for Sin-1. The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 74 +/- 3 and 55 +/- 5% for molsidomine and Sin-1, respectively. The method was found to be linear in the 0.5-50 ng/ml concentration range for the two analytes (r2 = 0.999 for both molsidomine and Sin-1). The mean RSD values for repeatability and intermediate precision were 3.4 and 4.8% for moldsidomine and 3.1-7.7% for the metabolite. The method developed was successfully used to investigate the bioequivalence of oral doses of molsidomine between a generic tablet and a reference product.  相似文献   

4.
Hydroxylated polychlorinated biphenyls also known as biphenylols, are suspected estrogen mimics found in the environment. Various derivatization schemes were evaluated and a gas chromatography-ion trap mass spectrometry method was developed for the trifluoroacetyl derivative using MS-MS techniques for the analysis of eleven biphenylols. A time-segmented chromatographic method was developed using the respective MS-MS parameters to analyze all the eleven biphenylols in a single chromatographic run. Isomers were differentiated based on the MS-MS data of the trofluoroacetyl-biphenylol derivatives. The method was applied to detect 40 pg on-column of these compounds in a spiked egg sample which simulates a real world sample.  相似文献   

5.
Betacyanins from cell cultures of Phytolacca americana were characterized and compared with those of the stems and ripening fruits of the plant. Whereas in fruits prebetanin (betanin 6'-O-sulphate) and its isoform predominate, in the stem and cell cultures feruloylated derivatives occur as the major components. These were rigorously identified by various spectroscopic techniques (DAD-HPLC, NMR, LC-MS and electrospray MS-MS) and carbohydrate analyses as betanidin 5-O-[(5"-O-E-feruloyl)-2'-O-beta-D-apiofuranosyl] -beta-D-glucopyranoside, a new betacyanin of higher plants, and betanidin 5-O-(6'-O-E-feruloyl)-beta-D-glucopyranoside (lampranthin II), together with their isoforms.  相似文献   

6.
Positive ion electrospray ionization mass spectrometry was used to obtain a lipid profile of vesicles prepared from egg yolk lethicin and enriched with arachidonylstearoyl phosphatidylcholine and dipalmitoyl phosphatidylcholine. The vesicles were oxidized by treatment with tert-butylhydroperoxide and iron (II) sulfate, and the formation of hydroperoxides of the polyunsaturated lipid arachidonylstearoyl phosphatidylcholine was observed. The native lipid signal at 832 a.m.u. decreased and new signals appeared at 864, 896, and 928 a.m.u., corresponding to the addition of one (+32), two (+64), and three (+96) molecules of dioxygen. The dihydroperoxide was found to be the most favourable peroxide product, but it appeared that a degradation of the hydroperoxides was occurring concomitant with their formation, and only their net formation was observed. The rate of depletion of the polyunsaturated lipid and the rate of accumulation of the hydroperoxides was found to increase with the Fe2+ concentration between 10 microM and 2 mM, and was also dependent on the tert-butylhydroperoxide concentration. This is the first report of analysis of lipid hydroperoxides by electrospray mass spectrometry, showing that technique offers a sensitive, direct, and informative approach to the study of oxidative damage to biological membranes.  相似文献   

7.
Arachidonic acid (AA) can be metabolized to a variety of lipid mediators including prostaglandins (PGE), and hydroxyeicosatetraenoic acids (HETE) by cyclooxygenase, lipoxygenase and cytochrome P450-dependent monooxygenase enzymatic pathways. Traditional experimental procedures to quantify these lipid mediators require purification, often by high performance liquid chromatography (HPLC), prior to derivatization for gas chromatography/mass spectrometry (GC/MS) analysis. This paper describes a rapid and simple technique for the simultaneous quantitative analysis of PGE2, 12-HETE, and AA by HPLC/electrospray ionization mass spectrometry on cultured human dermal fibroblast supernatants. Extension of the method to analyse 5-HETE and 15-HETE was investigated. The advantages of this method include minimal sample preparation and elimination of the problem associated with thermal stability for GC/MS analysis. A detection limit of 20pg on column for PGE2 and 5pg on column for 12-HETE and AA was determined.  相似文献   

8.
An analytical method based on radioimmunoassay (RIA) has been developed for the determination of the antiarrhythmic agent, MK-0499, in plasma and urine. Owing to the potency of the drug, the specificity of this assay in human plasma could not be adequately determined using conventional RIA procedures. A highly specific procedure, based on LC/MS-MS, was developed to cross-validate the RIA. The lower quantifiable limits of the RIA and LC/MS-MS-based methods were 0.05 and 0.013 ng ml-1, respectively. Cross-validation data, compared using paired student's t-test regression analysis, showed excellent correlation between methods. The mass spectrometric assay was also used to simultaneously measure plasma concentrations of unlabeled and 14C-labeled MK-0499 following administration of the drug at high specific activity to volunteers.  相似文献   

9.
A new sheath flow microelectrospray interface combines capillary electrophoretic separation of protein standards with condensation particle counting detection. Protein separations are performed in both coated and uncoated fused-silica columns. The electrospray needle utilizes a sheath flow rate between 0 and a few microL/min. Typically, the makeup flow is equal to or less than the electroosmotic flow from the separation capillary; thus there is minimal dilution while still providing pH adjustment and solid electrical contact with the separation capillary. While there are some inherent restrictions to a condensation particle counting detector, the microelectrospray needle performs well and has direct application to electrospray mass spectrometry.  相似文献   

10.
A methodology is described for creating a monolithic chromatography support within a pulled fused-silica electrospray needle. The monolith was formed from a mixture of styrene, divinylbenzene, 1-dodecanol, and toluene using 2,2'-azobis(isobutyronitrile) as the catalyst. The mixture was loaded into 150-micron-i.d. fused-silica capillary tubing with a pulled 5-10-micron needle tip at one end. Polymerization at 65 degrees C followed by removal of the porogen material yielded a stable, porous, monolithic support which had excellent properties for the separation and on-line, electrospray, mass spectrometry analysis of peptides and proteins. The performance of the monolith-filled electrospray needles was compared with similar needles filled with commercial C18 silica and polymeric particulate supports. Separation efficiencies for both protein and peptide mixtures were generally equal to or better than the particulate supports at comparable pressures and flow rates. The ion chromatograms derived from the on-line MS analysis were remarkably free from chemical background signals that often complicate the LC/MS analysis of femtomole amounts of sample. Good sequence coverage was obtained by LC/MS/MS analysis of the peptide mixture obtained from a protein isolated by silver-stained gel electrophoresis. The capability of the monolith to do peak parking experiments was demonstrated by the characterization of an immunoreactive HPLC fraction. The simple fabrication method, chromatographic performance, and robust nature of these microscale integrated column electrospray sources make them ideally suited for high-sensitivity tandem LC/MS analyses.  相似文献   

11.
Heating or freezing leads to loss in infectivity of oocysts of Cryptosporidium parvum toward neonatal BALB/c mice and is reflected in the profile of the polar lipid fatty acids. Upon loss of infectivity, the ratio of polar lipid to neutral lipid fatty acid decreased and the relative proportions of 18:1n-9 also decreased; proportions of 18:2n-6 and 20:5n-6 increased, whereas the proportions of 16:0 remained constant with freezing. During these investigations, a novel fatty acid, 10-OH 18:0, was discovered in the glycolipid fraction. The identification of a fatty acid unique to species of Cryptosporidium was thought to provide a specific biomarker for this organism. Cryptosporidium also demonstrated fluctuations in absolute quantities of 10-OH 18:0 with events that lead to loss of infectivity. This led to the presumed correlation of this biomarker with infectious Cryptosporidium. The 10-OH 18:0 was putatively localized at the sn-2 position of phosphatidylethanolamine. High-performance liquid chromatography/electrospray ionization mass spectrometry revealed that the 10-OH 18:0 existed principally in the free fatty acid form. Herein, we establish that the free fatty acid 10-OH 18:0 was, in actuality, an artifact of the procedures for sample preparation.  相似文献   

12.
Analyses of the peptidoglycan nucleotide precursor contents of enterococci and staphylococci treated with ramoplanin, tunicamycin, or vancomycin were carried out by high-pressure liquid chromatography coupled with mass spectrometry (MS). In all cases, a sharp increase in the UDP-N-actetylmuramoyl-pentapeptide or -pentadepsipeptide pool was observed. Concomitantly, new peptidoglycan nucleotide peptides of higher molecular masses with hexa- or heptapeptide moieties were identified: UDP-MurNAc-pentapeptide-Asp or pentadepsipeptide-Asp in enterococci and UDP-MurNAc-pentapeptide-Gly or -Ala and UDP-MurNAc-pentapeptide-Gly-Gly or -Ala-Gly in staphylococci. These new compounds are derivatives of normal UDP-MurNAc-pentapeptide or -pentadepsipeptide precursors with the extra amino acid(s) linked to the lysine epsilon-amino group as established by various analytical procedures (MS, MS-MS fragmentation, chemical analysis, and digestion with R39 D,D carboxypeptidase). Except for tunicamycin-treated cells, it was not possible to ascertain whether these unusual nucleotides were formed by direct addition of the amino acids to UDP-MurNAc-pentapeptide (or -pentadepsipeptide) or whether they arose by reverse reactions from lipid I intermediates to which the amino acids had been added.  相似文献   

13.
Nanoelectrospray mass spectrometry, the infusion at low flow rates of unseparated peptide mixtures representing protein proteolytic digests into an electrospray ionization mass spectrometer (MS), has been shown to be a suitable method for the analysis of small amounts of proteins. However, the current technique is time consuming, tedious, and difficult to automate. We used microfabrication technologies to construct a device for the sequential infusion of different peptide samples into an electrospray ionization MS without the need for sample manipulation. In this device, etched sample and buffer reservoirs are connected via etched channels to microelectrospray ion source. Peptide samples, typically unseparated tryptic digests of proteins, are applied to different reservoirs. A flow of liquid originating from a specific reservoir is generated and selectively directed toward the microsprayer and the MS by electroosmotic pumping. The analyte proteins are identified by searching sequence databases with the information contained in the collision-induced spectra of selected peptides. With this system, we have achieved a limit of detection in the low femtomoles per microliter range for peptide standards. We also show that samples deposited in different reservoirs can be sequentially mobilized without cross-contamination and that proteins can be conclusively identified at the low femtomoles per microliter level. The successful coupling online of microfabricated devices to an electrospray ionization MS represents an essential step toward the construction of automated, high-throughput, and high-sensitivity analytical systems.  相似文献   

14.
The photochemical behavior of pesticides in a photolysis reactor coupled on-line with a liquid chromatography-electrospray ionization mass spectrometer (LC-hv-MS) was investigated. This paper describes the application of LC-hv-MS, in combination with tandem mass spectrometry (MS-MS), to identification of phototransformation products and to the establishment of possible photolytic pathways of pesticides. In addition, the applicability of LC-hv-MS as an alternative to LC-MS-MS, for trace and confirmatory multiresidue analysis in food samples was investigated. To demonstrate the potential of this technique, a series of N-heterocyclic compounds, phenylureas and carbamates, was studied. Several parameters, such as irradiation time and nature of photosensitizers, were investigated, and their impact on the photolytic transformation is presented here. The technique's versatility is also exhibited by using it for identification of triazine isomers, and for detection of pesticide residues in food sample extracts. Illustrative applications for analysis in lettuce and blueberry extracts are described.  相似文献   

15.
1. Free radical-dependent lipid peroxidation processes have long been thought to contribute to brain damage following stroke or cerebral ischemia/reperfusion. 2. The preponderance of evidence for this belief has been derived indirectly, through diminution of tissue injury indices (e.g., brain infarct volume) facilitated by application of free radical scavenger substances. 3. Direct, unequivocal evidence for lipid peroxidation in terms of classical assays (detection of conjugated diene absorbance or thiobarbituric acid-reactive substances) is considerably less common, and its validity can be questioned. 4. Correlations of treatment-induced diminishment of brain injury indices with reductions in lipid peroxidation level are rarer still. 5. Reasons underlying the disparity between the belief that lipid peroxidation contributes to ischemic brain injury and direct evidence for this contribution (at least acutely) are proposed, along with evidence that new methods are being developed which should provide the basis for obtaining a definitive answer.  相似文献   

16.
A rapid and systematic LC-MS protocol is utilized to profile buspirone metabolites. Analysis of rat bile, urine and liver S9 samples using a standard LC-MS method provides structural information for 25 metabolites. The resulting buspirone metabolite structure database contains characteristic retention time, molecular mass and MS-MS product ion information for each compound. Metabolites are categorized according to profile groups, which illustrate that substitution reactions are primarily associated with the azaspirone decane dione and pyrimidine substructures. Structures of new buspirone metabolites are reported and include the despyrimidinyl, despyrimidinylpiperazine, glucuronide, hydroxyglucuronide (four isomers), methoxyglucuronide and hydroxymethoxyglucuronide (two isomers) buspirone metabolites.  相似文献   

17.
The production of vesicles, spherical shells formed from lipid bilayers, is an important aspect of their recent application to drug delivery technologies. One popular production method involves pushing a lipid suspension through cylindrical pores in polycarbonate membranes. However, the actual mechanism by which the polydisperse, multilamellar lipid suspension breaks up into a relatively monodisperse population of vesicles is not well understood. To learn about factors influencing this process, we have characterized vesicles produced under different extrusion parameters and from different lipids. We find that extruded vesicles are only produced above a certain threshold extrusion pressure and have sizes that depend on the extrusion pressure. The minimum pressure appears to be associated with the lysis tension of the lipid bilayer rather than any bending modulus of the system. The flow rate of equal concentration lipid solutions through the pores, after being corrected for the viscosity of water, is independent of lipid properties.  相似文献   

18.
An electrospray ionization-mass spectrometric procedure has been developed for determining glycohemoglobin. Whole-blood samples from 78 diabetic and 50 nondiabetic subjects (glycation range 3-15%, as determined by electrospray mass spectrometry) were diluted 500-fold in an acidic denaturing solvent and introduced directly into a mass spectrometer. The resulting mass spectra were then processed to estimate the percentage of glycohemoglobin present in the sample. Total analysis time, including plotting the spectra and computing the percentage of glycation, was approximately 3 min. The imprecision (CV) of the method was < 5.1% for inter- and intrabatch analyses for total glycohemoglobin in the range 3.6-14%. Comparison of the mass spectrometric results with those from established affinity chromatographic procedures showed good overall agreement. The relative glycation of the alpha- and beta-chains was determined directly and was shown to be constant (0.64:1) over the glycation range measured. Only single glucose attachment to both the alpha- and beta-chains was observed.  相似文献   

19.
A convenient and rapid micro-anion exchange liquid chromatography (LC) tandem electrospray mass spectrometry (MS) procedure was developed for quantitative analysis in serum of O-isopropyl methylphosphonic acid (IMPA), the hydrolysis product of the nerve agent sarin. The mass spectrometric procedure involves negative or positive ion electrospray ionization and multiple reaction monitoring (MRM) detection. The method could be successfully applied to the analysis of serum samples from victims of the Tokyo subway attack and of an earlier incident at Matsumoto, Japan. IMPA levels ranging from 2 to 135 ng/ml were found. High levels of IMPA appear to correlate with low levels of residual butyrylcholinesterase activity in the samples and vice versa. Based on our analyses, the internal and exposure doses of the victims were estimated. In several cases, the doses appeared to be substantially higher than the assumed lethal doses in man.  相似文献   

20.
To reliably identify the residual tetracycline antibiotics (TCs), oxytetracycline (OTC), tetracycline, chlortetracycline (CTC) and doxycycline (DC), in bovine tissues, we have established a confirmation method using electrospray ionization liquid chromatography-tandem mass spectrometry (ESI LC-MS-MS) with daughter ion scan. All TCs gave [M+H-NH3]+ and [M+H-NH3-H2O]+ as the product ions, except for DC when [M+H]+ was selected as the precursor ion. The combination of C18 cartridge clean-up and the present ESI LC-MS-MS method can reliably identify TCs fortified at a concentration of 0.1 ppm in bovine tissues, including liver, kidney and muscle, and has been successfully applied to the identification of residual OTC in bovine liver and residual CTC in bovine muscle samples previously found at concentrations of 0.58 ppm and 0.38 ppm by LC, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号