Patent ductus arteriosus is an uncommon anomaly in adult patients. Surgical closure of patent ductus arteriosus in this age group presents difficult problems to the surgeon. We report our experience of 21 adult patients (19-62 years of age, mean 40 years) who underwent closure of the ductus by transfemoral implantation of a Rashkind double umbrella device. The patients came to light because of atrial fibrillation, congestive heart failure, residual flow after surgical ligation of the duct or because of incidental diagnosis made during physical examination or chest X-ray. In ten patients the pulmonary arterial pressure was normal (systolic pressure < 30 mmHg), in eleven it was elevated (systolic pressure from 30 to 100 mmHg, mean 50 mmHg). In seven patients the duct was clearly calcified and the size of the duct varied from 3 to 9 mm (mean 4.3 mm). In 16 patients the ductus resulted perfectly closed after implantation of the first double umbrella device, two patients had minimal residual aortopulmonary flow, whereas in three patients the residual shunt was significant; two of these also developed haemolysis and went to surgery, in the latter the shunt was completely abolished after implantation of a second 17-mm device 16 months later. In conclusion transcatheter closure of patent ductus arteriosus in adults is feasible, even in the presence of calcifications and/or pulmonary hypertension; taking into account the significant surgical risk, PDA umbrella closure should be considered the first choice procedure in this group of patients.  相似文献   

2.
Two patients who underwent transcatheter closure of patent ductus arteriosus, one with a Rashkind umbrella device and the other with a coil, suffered from acute hemolysis following the procedure. Hemolysis ceased after deployment of second device(s) within 48 hr without needing to retrieve the first devices in either patient. We conclude that immediate deployment of a second device(s) is an alternative to surgery when acute hemolysis occurs following transcatheter closure of ductus.  相似文献   

3.
Three patients were submitted to the Rashkind device technique for closure of a patent ductus arteriosus. The percutaneous transvenous technique was employed in every cases. A 12 mm prosthesis was utilized in one case and 17 mm prostheses in the other two cases. In the first case, after temporary occlusion of the ductus arteriosus, the prostheses was removed due to the technical impossibility of evaluation of the proximal umbrella position. In the second and third cases, the prostheses were duly liberated in the proper position, thus occluding the defects. This technique does not require general anesthesia, is indicated in patients over 6 kgs of body weight, and is a therapeutic alternative to the habitual surgical procedure.  相似文献   

4.
From May 1991 to August 1994, we performed transcatheter closure of patent ductus arteriosus with Rashkind umbrella system in 25 patients. In one, the device had embolism, to the right pulmonary artery and was operated 24 hs afterwards without complications. Seven had residual shunts, two had subsequent surgery, two are being followed (one for mild and one for moderate residual shunt). In the other three cases we inserted a second device. We used a 12 mm device in two cases and a 17 mm device in the other. Two cases had total occlusion 24 hrs after and in one had mild residual shunt without clinical repercussion. There were no complications. All had electrocardiographic and clinical improvement, take no medication, and their cardiomegaly had decreased (Cardiac index pre 61 vs post 54%). In conclusion the insertion of a second device is safe and effective alternative for residual shunt after first Rashkind occluder.  相似文献   

5.
AIM: The aim of this study was to investigate whether before releasing the Rashkind occluder system for occlusion of persistently patent ductus arteriosi Botalli from the delivery catheter its position can be adequately demonstrated sonographically to avoid angiography. METHOD: From March to August 1993 occlusion of a persistently patent ductus arteriosus by means of the Rashkind system was carried out in 10 patients. A standard technique using transthoracic echocardiography was used. RESULTS: Echocardiography allowed to demonstrate and locate the occluder system in all cases. CONCLUSION: Echocardiography is a reliable means for locating the Rashkind occluder system avoiding angiography.  相似文献   

6.
The results of new methods for catheter treatment of congenital heart defects are presented. Between 1989 and 1996 closure of a patent ductus arteriosus was performed in 66 instances on 63 patients, eight of which were with coils. Three patients were treated twice, one with an additional umbrella, two with coils. The overall complete closure rate for umbrellas was 75%, after two ducts, which were initially totally occluded, recanalized. In six more patients the procedure was either aborted or indication was not present. All six ducts treated with coils as the first procedure were completely closed. One of two patients who had residual leak after previous umbrella treatment achieved complete closure after subsequent coil implantation. Closure of atrial septal defects in the oval fossa was performed using the Amplatzer septal occluder in seven children. Complete closure was achieved in all of them. There have been no complications, in particular there have been no cases of embolization in any of the groups. The results seem to indicate that coil occlusion of a persistently patent duct may be at least as good as the umbrella in terms of complete closure. So far both methods have been safe, but experience with coils is limited. The closure of atrial septal defects shows encouraging results. We will continue to offer this treatment as an alternative to open heart surgery in carefully selected patients.  相似文献   

7.
8.
9.
BACKGROUND: The Rashkind double umbrella device for patent arterial duct occlusion has been used in many patients. Its radiographic appearance has not been sufficiently described. OBJECTIVE: To present the varying radiographic appearances of the Rashkind double umbrella device on the chest X-ray. MATERIALS AND METHODS: The chest radiographs of 69 patients (median age 60 months; median weight 17 kg), who underwent closure of their patent arterial duct between March 1990 and August 1994, were reviewed. The following parameters were evaluated: 1) the size of the heart (cardio-thoracic ratio) and pulmonary vessels, 2) the position of the device in AP/PA and lateral projections. The results of occlusion of the patent arterial duct were also reviewed. RESULTS: Sixty-two of 69 (90 %) patients had complete occlusion after a follow-up between 2 months and 3(1)/2 years. The cardio-thoracic ratio showed significant reduction at follow-up (P < 0.001). The two different size devices could be well differentiated in the AP and the lateral projection. In 14 patients (20 %) the device was in an asymmetrical position. There was no significant correlation between position of the device and success of occlusion in our material. CONCLUSION: Complete occlusion of the arterial duct using Rashkind double umbrella devices can be achieved in 90 % of our population. In 20 % the device will have an asymmetrical position. There is no correlation between asymmetrical position of the device in the chest radiograph and residual shunting.  相似文献   

10.
It is unknown whether the decreased cerebral blood flow seen in infants with a large patent ductus arteriosus is associated with cerebral dysfunction. Decreased cerebral blood flow in adult human and animal models has been associated with altered electroencephalography (EEG), spectral-analyzed EEG, and EEG response to photic stimulation. Cerebral blood flow velocity, EEG, spectral analysis of EEG, and photic alteration of EEG spectra were evaluated in 8 infants before and after closure of a significant patent ductus arteriosus and in 10 control infants without a patent ductus arteriosus. All infants with patent ductus arteriosus had moderate or large shunts associated with a 25% mean reduction in cerebral blood flow velocity. There were no differences, however, in EEG, spectral analysis of EEG, or photic alteration of the spectral analysis for these infants before and after patent ductus arteriosus closure as compared to controls. It is concluded that the degree of decreased cerebral blood flow in infants with a significant patent ductus arteriosus is not sufficient to cause measurable alteration in electrocortical activity.  相似文献   

11.
The paediatric therapeutic heart catheterization becomes more and more important in the treatment of congenital heart disease. Depending on the situation, interventional therapy can become an alternative or a replacement or supplement to surgical intervention. The methods of interventional therapy include the balloon valvuloplasty of stenotic valves or vessels, the implantation of stents and the occlusion of defects as well as of unwanted vascular structures with coil embolisation or umbrella devices. The balloon valvuloplasty of pulmonary valve stenosis or the embolisation of small vessels have become the treatment of choice. Valvuloplasty of aortic stenosis, angioplasty of residual coarctation, balloon dilatation of peripheral pulmonic stenosis and occlusion of a patent ductus arteriosus with a Rashkind PDA-occluder are now a valuable alternative to surgical procedure although studies of long-term results are not yet available. Occlusions of atrial or ventricular septal defects as well as the implantation of stents are still investigational tools, but give enormous hope for the future.  相似文献   

12.
Controlled-release coils have become available recently for the closure of patent ductus arteriosus (PDA). Transcatheter closure of patent arterial ducts was attempted in 13 patients, ranging in age from 5 months to 15 years, mean 4.1 years. Implantation of controlled-release PDA coils was attempted via the femoral artery through 5 Fr catheters in all cases except one, in whom both the femoral arterial and venous routes were used. The procedure was successful in 10 of the 13 patients. In these, the pulmonary artery systolic pressure ranged between 25 and 42 mmHg and the duct diameter varied from 1.5 to 6 mm at its narrowest point. Six of the patients received a single coil. Two coils were inserted in three patients and three coils in one patient. In three patients the ducts were too large for safe release of the coils, despite attempted implantation of up to three coils simultaneously. These coils were easily withdrawn into the catheter. Immediately at the end of the procedure, the duct was completely occluded in nine of the 10 patients, and in one patient there was a small residual flow. The procedure time varied between 35 min and 2.5 h, mean 81 min and the fluoroscopy time varied from 5 to 78 min, mean 25 min. None of the patients experienced hemorrhage, diminished lower extremity pulse, hemolysis or infection. In one patient, a 5 mm coil embolized into the right pulmonary artery soon after release. It was retrieved with a snare, then 8 mm and a 5 mm coil were implanted satisfactorily in the arterial duct. At follow-up by color Doppler echocardiography, the duct was completely occluded in all patients. Transcatheter closure of patent arterial ducts by controlled-release PDA coils is effective and safe. Even when more than one coil is inserted, it is still cheaper than transcatheter umbrella closure. This method is therefore of great value, particularly in less affluent countries.  相似文献   

13.
Intraoperative epicardial echocardiography (IEE) is very useful to assess the result of the surgical procedure. In infancy and childhood the authors performed 32 IEE (using high frequency transducer) out of 193 operations with congenital heart diseases. As a result of IEE study the surgical procedure was extended in 5 cases, as follows: closure of patent ductus arteriosus, exchange of transanular patch, repeated mitral repair, prosthetic mitral valve implantation, and correction of residual right to left shunt. No early or late reoperation was necessary in the remaining cases. Follow up echocardiography and autopsy in 4 cases confirmed the diagnosis of the IEE. The results suggest, that IEE will be the standard method for quality control of surgical procedures in congenital heart disease.  相似文献   

14.
Jackson screwing detachable coils, developed for arterial and venous embolization, have been successfully employed recently for the percutaneous occlusion of patent ductus arteriosus (PDA). Special screwing detachable coils were designed for closure of the PDA, and the experience gained by their use is described in this report. Occlusion was attempted in 29 patients with a minimal ductal diameter of 0.9-4.2 mm. Coils were successfully placed in all 29 patients. One coil, which embolized 10 min after detachment, was retrieved. In 26 patients (89%), complete closure was achieved. Only 35 coils were placed in 29 patients. Residual shunts in three patients are minimal, detectable only on color-flow mapping. Screwing detachable coils for closure of PDA are safe and effective for occlusion of PDA with a minimal diameter < 4.2 mm. Embolization of the coil is very rare. A high closure rate is achieved with a low number of placed coils.  相似文献   

15.
RATIONALE AND OBJECTIVES: Several devices have been suggested and tested for interventional closure of the persistent ductus arteriosus. Coils were found effective only in small ducts due to their lack of maneuverability and physical limitation of grip forces leading to risk of embolization. The authors evaluated the feasibility to place single coils with selectively enhanced stiffness into high shunting ductus arteriosus, the coils being deployed and controlled through a veno-arterial loop in a bovine model. METHODS: "Double-cone" shaped, stainless steel coils with enhanced stiffness of the outer rings were mounted on either end on a nitinol core wire. A snap-in mechanism attaches the coil to this delivery wire and is freed by a pusher system of coiled steel wire that is advanced over the core wire. Forming a veno-arterial loop across the patent ductus allows for repositioning into the pulmonary artery or aortic catheter. A chronic lamb model of large patent ductus arteriosus (PDAs) (> or = 9 mm) was used in which ductus patency was secured by a protocol of repetitive angioplasties. Different systems (n = 10) were placed having retrieved the previous coil by a snare after definitive release. RESULTS: Placement of coils was possible in all 10 attempts. The coils were pulled back into the catheters between five and eight times before definitive release. CONCLUSIONS: The device allows controlled placement of single coils in our model of large PDAs and may lead the way to overcome previous limitations of coils. Clinical trials are warranted.  相似文献   

16.
New insights into the closure of the ductus arteriosus may lead to more effective nonsurgical treatment in patent ductus arteriosus. ET-1 agonists may prove useful in future pharmacologic interventions.  相似文献   

17.
Transaxillary muscle-sparing patent ductus arteriosus closure performed as same-day surgery is described in 10 patients. This approach provides a superb cosmetic result while obviating the need for thoracostomy tube placement.  相似文献   

18.
In hearts with a common arterial trunk (truncus arteriosus), there is almost always an inverse development of the aortic arch and the ductus arteriosus. Truncus with a normal aortic arch and a patent ductus is a rare echocardiographic and surgical finding. In this report, we describe 2 neonates in whom truncus arteriosus with a normal aortic arch and a medium or large patent ductus was diagnosed by preoperative echocardiography (without catheterization) and confirmed intraoperatively.  相似文献   

19.
Release of the Rashkind ductus umbrella may be complicated in that the central wire of the delivery catheter may become trapped within the foam of the umbrella. This problem occurs only if the central retaining wire is advanced when trying to disengage the catheter and umbrella. We propose a simple solution to the problem: Retract the sleeve instead of advancing the retaining wire.  相似文献   

20.
OBJECTIVE: To evaluate retrospectively our surgical experience, techniques and long-term results in 11 patients with coronary artery fistulae associated with other cardiovascular anomalies. METHODS: From January 1980 to April 1995, 11 patients with coronary artery fistulae associated with other cardiovascular anomalies were found among 20,000 open-heart procedures and treated surgically. Besides closure of the fistulae, coronary artery bypass grafting was performed in 5 patients with atherosclerotic coronary artery disease, and aneurysm angioplasty was done in 4 patients with coronary artery aneurysm. Ventricular septal defect and patent ductus arteriosus were closed in one patient and mitral valve replacement was performed in another patient. RESULTS: There were no surgical deaths, but one late death due to acute myocardial infarction occurred 6 months after surgery. The mean follow-up time was 75.7 months and all patients' functional status improved by an average 1.4 judged by the New York Heart Association functional classification. CONCLUSIONS: Coronary artery fistula associated with other cardiovascular anomalies will aggravate symptoms and cause deterioration of heart function. Therefore, evaluation and surgical intervention should be done as soon as possible to restore coronary blood flow and correct concomitant cardiovascular anomalies. The surgical results are excellent with a low operative risk and good long-term results.  相似文献   