首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Temperature is one of the factors that most influences chlorine decay rates in drinking water systems. The current paper assesses and demonstrates the importance of using a temperature dependent chlorine bulk decay model for the accurate prediction of disinfectant residuals in water supply systems. Chlorine concentration in a water transmission system was modelled for two seasons using a temperature-dependent bulk decay model at a constant and variable temperature. Results show that water temperature can vary within the system and that the accurate prediction of residuals may additionally require the incorporation of a water temperature model in the simulators. In this case study such approach was developed innovatively by establishing a water-age-dependent temperature function.  相似文献   

2.
An ever-growing need exists for rapid, quantitative and meaningful methods to quantify and characterize the effect of different treatment steps on the microbiological processes and events that occur during drinking water treatment and distribution. Here we compared cultivation-independent flow cytometry (FCM) and adenosine tri-phosphate (ATP) analysis with conventional cultivation-based microbiological methods, on water samples from two full-scale treatment and distribution systems. The two systems consist of nearly identical treatment trains, but their raw water quality and pre-treatment differed significantly. All of the drinking water treatment processes affected the microbiological content of the water considerably, but once treated, the finished water remained remarkably stable throughout the distribution system. Both the FCM and ATP data were able to describe the microbiology of the systems accurately, providing meaningful process data when combined with other parameters such as dissolved organic carbon analysis. Importantly, the results highlighted a complimentary value of the two independent methods: while similar trends were mostly observed, variations in ATP-per-cell values between water samples were adequately explained by differences in the FCM fingerprints of the samples. This work demonstrates the value of alternative microbial methods for process/system control, optimization and routine monitoring of the general microbial quality of water during treatment and distribution.  相似文献   

3.
Inhalation exposure to THMs from drinking water in south Taiwan   总被引:4,自引:0,他引:4  
Trihalomethanes (THMs) are important disinfection byproducts (DBPs) in drinking water. To understand the magnitude of exposure to THMs for the people in southern Taiwan, models are used to estimate the inhalation exposure associated with drinking water based on raw water quality. Two parts of models are used in this study, one for estimating THM concentration from raw water quality, and one for estimating inhalation exposure to people. Important raw water quality and operational parameters, including TOC, UV254, pH, temperature, chlorine dosage, and water residence time of a major water treatment plant in south Taiwan were collected. An empirical THM formation model was then employed to predict the THM concentration at consumers' dwellings based on the parameters collected. Differences between the predicted results and experimental data were found to be small, indicating that the model is appropriate. The predicted THM concentration distribution was served as input parameters for the exposure models. Three major scenarios associated with probable inhalation exposure of THMs, including shower, pre- and post-cooking activities, and cooking processes, were considered in the exposure models. The model results show that the mean inhalation exposure of THMs for shower, pre- and post-cooking activities, and cooking processes are 26.4, 1.56, 3.29 micrograms/day, respectively. The total inhalation exposure (summation of the three scenarios) was found to be comparable with that for direct ingestion, indicating that inhalation is an important pathway for THM exposure from drinking water.  相似文献   

4.
Investigation of assimilable organic carbon (AOC) in flemish drinking water   总被引:2,自引:0,他引:2  
The aim of the study was to investigate the drinking water supplied to majority of residents of Flanders in Belgium. Over 500 water samples were collected from different locations, after particular and complete treatment procedure to evaluate the efficiency of each treatment step in production of biologically stable drinking water. In this study assimilable organic carbon (AOC) was of our interest and was assumed as a parameter responsible for water biostability. The influence of seasons and temperature changes on AOC content was also taken into account. The AOC in most of the non-chlorinated product water of the studied treatment plants could not meet the biostability criteria of 10 mug/l, resulting in the mean AOC concentration of 50 microg/l. However, majority of the examined chlorinated water samples were consistent with proposed criteria of 50--100 microg/l for systems maintaining disinfectant residual. Here, mean AOC concentration of 72 microg/l was obtained. Granular activated carbon filtration was helpful in diminishing AOC content of drinking water; however, the nutrient removal was enhanced by biological process incorporated into water treatment (biological activated carbon filtration). Disinfection by means of chlorination and ozonation increased the water AOC concentration while the ultraviolet irradiation showed no impact on the AOC content. Examination of seasonal AOC variations showed similar fluctuations in six units with the highest values in summer and lowest in winter.  相似文献   

5.
Perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) have been recognized as global environmental pollutants. Although PFOS and PFOA have been detected in tap water from Japan and several other countries, very few studies have examined the fate, especially removal, of perfluorinated compounds (PFCs) in drinking water treatment processes. In this study, we analyzed PFOS and PFOA at every stages of drinking water treatment processes in several water purification plants that employ advanced water treatment technologies. PFOS and PFOA concentrations did not vary considerably in raw water, sand filtered water, settled water, and ozonated water. Sand filtration and ozonation did not have an effect on the removal of PFOS and PFOA in drinking water. PFOS and PFOA were removed effectively by activated carbon that had been used for less than one year. However, activated carbon that had been used for a longer period of time (>1 year) was not effective in removing PFOS and PFOA from water. Variations in the removal ratios of PFOS and PFOA by activated carbon were found between summer and winter months.  相似文献   

6.
Detection of enteroviruses in treated drinking water   总被引:4,自引:0,他引:4  
Vivier JC  Ehlers MM  Grabow WO 《Water research》2004,38(11):2699-2705
This study deals with the routine monitoring of drinking water for the presence of enteroviruses, over a period of 1 year. A rapid and simple method was employed for the simultaneous detection and typing of enteroviruses in large-volume water samples. This included an integrated cell culture/nested PCR approach, followed by restriction enzyme analysis. The two drinking water supplies studied were derived from acceptable quality surface water sources using treatment processes, which conform to international specifications for the production of safe drinking water. Enteroviruses (predominantly coxsackie B viruses) were detected in 11% and 16% of the drinking water samples from two treatment plants, respectively. This study confirms that acceptable water quality indicators do not necessarily reflect the virus content of drinking water.  相似文献   

7.
Chloramine is widely used in United States drinking water systems as a secondary disinfectant, which may promote the growth of nitrifying bacteria because ammonia is present. At the onset of nitrification, both nitrifying bacteria and their products exert a monochloramine demand, decreasing the residual disinfectant concentration in water distribution systems. This work investigated another potentially significant mechanism for residual disinfectant loss: monochloramine cometabolism by ammonia-oxidizing bacteria (AOB).Monochloramine cometabolism was studied with the pure culture AOB Nitrosomonas europaea (ATCC 19718) in batch kinetic experiments under drinking water conditions. Three batch reactors were used in each experiment: a positive control to estimate the ammonia kinetic parameters, a negative control to account for abiotic reactions, and a cometabolism reactor to estimate the cometabolism kinetic constants. Kinetic parameters were estimated in AQUASIM with a simultaneous fit to all experimental data. The cometabolism reactors showed a more rapid monochloramine decay than in the negative controls, demonstrating that cometabolism occurs. Cometabolism kinetics were best described by a pseudo first order model with a reductant term to account for ammonia availability. Monochloramine cometabolism kinetics were similar to those of ammonia metabolism, and monochloramine cometabolism was a significant loss mechanism (30–60% of the observed monochloramine decay). These results suggest that monochloramine cometabolism should occur in practice and may be a significant contribution to monochloramine decay during nitrification episodes in drinking water distribution systems.  相似文献   

8.
Removal or inactivation of viruses in drinking water treatment processes can be quantified by measuring the concentrations of viruses or virus indicators in water before and after treatment. Virus reduction is then calculated from the ratio of these concentrations. Most often only the average reduction is reported. That is not sufficient when treatment efficiency must be characterized in quantitative risk assessment.We present three simple models allowing statistical analysis of series of counts before and after treatment: distribution of the ratio of concentrations, and distribution of the probability of passage for unpaired and paired water samples.Performance of these models is demonstrated for several processes (long and short term storage, coagulation/filtration, coagulation/sedimentation, slow sand filtration, membrane filtration, and ozone disinfection) using microbial indicator data from full-scale treatment processes.All three models allow estimation of the variation in (log) reduction as well as its uncertainty; the results can be easily used in risk assessment. Although they have different characteristics and are present in vastly different concentrations, different viruses and/or bacteriophages appear to show similar reductions in a particular treatment process, allowing generalization of the reduction for each process type across virus groups.The processes characterized in this paper may be used as reference for waterborne virus risk assessment, to check against location specific data, and in case no such data are available, to use as defaults.  相似文献   

9.
In temperate regions, seasonal variability of environmental factors affects the bacterial community in source water and finished drinking water. Therefore, the bacterial core community and its seasonal variability in cold and the respective hot drinking water was investigated. The bacterial core community was studied by 16S rRNA-based SSCP fingerprint analyses and band sequencing of DNA and RNA extracts of cold and hot water (60 °C). The bacterial communities of cold and hot drinking water showed a highly different structure and phylogenetic composition both for RNA and DNA extracts. For cold drinking water substantial seasonal dynamics of the bacterial community was observed related to environmental factors such as temperature and precipitation affecting source and drinking water. Phylogenetic analyses of the cold water community indicated that the majority of phylotypes were very closely affiliated with those detected in former studies of the same drinking water supply system (DWSS) in the preceding 6 years, indicating a high stability over time. The hot water community was very stable over time and seasons and highly distinct from the cold water with respect to structure and composition. The hot water community displayed a lower diversity and its phylotypes were mostly affiliated with bacteria of high temperature habitats with high growth rates indicated by their high RNA content. The conversion of the cold to the hot water bacterial community is considered as occurring within a few hours by the following two processes, i) by decay of most of the cold water bacteria due to heating, and ii) rapid growth of the high temperature adapted bacteria present in the hot water (co-heated with the cold water in the same device) using the nutrients released from the decaying cold water bacteria. The high temperature adapted bacteria originated partially from low abundant but beforehand detected members of the cold water; additionally, the rare members (“seed bank “) of the cold water are considered as a source.  相似文献   

10.
Discolouration of drinking water is one of the main reasons customers complain to their water company. Though corrosion of cast iron is often seen as the main source for this problem, the particles originating from the treatment plant play an important and potentially dominant role in the generation of a discolouration risk in drinking water distribution systems. To investigate this thesis a study was performed in a drinking water distribution system. In two similar isolated network areas the effect of particles on discolouration risk was studied with particle counting, the Resuspension Potential Method (RPM) and assessment of the total accumulated sediment. In the ‘Control Area’, supplied with normal drinking water, the discolouration risk was regenerated within 1.5 year. In the ‘Research Area’, supplied with particle-free water, this will take 10-15 years. An obvious remedy for controlling the discolouration risk is to improve the treatment with respect to the short peaks that are caused by particle breakthrough.  相似文献   

11.
There has been increasing interest in the widely used perfluorinated chemicals such as perfluorooctane sulphonate (PFOS). PFOS has been shown to be toxic, persistent and bioaccumulative in the environment and is a focus for restriction within the European Union. Limited monitoring data, especially in the United Kingdom, are available for PFOS in environmental waters, and even less for its detection in drinking water. Data available in the United Kingdom indicate that PFOS contamination of environmental waters has only occurred following specific incidents. Monitoring of 20 raw and treated drinking water sites in England, covering four seasonal periods, showed that PFOS is not a widespread background contaminant of raw and treated drinking water in England. Low levels of PFOS (0.012–0.208 μg/L) were detected at four specific sites, which were at a higher risk for contamination. At three of these sites, where PFOS was detected in both raw and final drinking water, treatment processes [chlorination, ozonation and granular activated carbon (GAC)] did not appear to remove PFOS. The findings of this work are pertinent to risk assessments now required by the drinking water quality regulations.  相似文献   

12.
Drinking water systems are vulnerable and subject to a wide range of risks. To avoid sub-optimisation of risk-reduction options, risk analyses need to include the entire drinking water system, from source to tap. Such an integrated approach demands tools that are able to model interactions between different events. Fault tree analysis is a risk estimation tool with the ability to model interactions between events. Using fault tree analysis on an integrated level, a probabilistic risk analysis of a large drinking water system in Sweden was carried out. The primary aims of the study were: (1) to develop a method for integrated and probabilistic risk analysis of entire drinking water systems; and (2) to evaluate the applicability of Customer Minutes Lost (CML) as a measure of risk. The analysis included situations where no water is delivered to the consumer (quantity failure) and situations where water is delivered but does not comply with water quality standards (quality failure). Hard data as well as expert judgements were used to estimate probabilities of events and uncertainties in the estimates. The calculations were performed using Monte Carlo simulations. CML is shown to be a useful measure of risks associated with drinking water systems. The method presented provides information on risk levels, probabilities of failure, failure rates and downtimes of the system. This information is available for the entire system as well as its different sub-systems. Furthermore, the method enables comparison of the results with performance targets and acceptable levels of risk. The method thus facilitates integrated risk analysis and consequently helps decision-makers to minimise sub-optimisation of risk-reduction options.  相似文献   

13.
Previous studies have demonstrated high removal rates of amphetamine-type-stimulants (ATSs) through conventional drinking water treatments; however the behaviour of these compounds through disinfection steps and their transformation into disinfection-by-products (DBPs) is still unknown. In this work, for the first time, the reactivity of some ATSs such as amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) with chlorine has been investigated under simulated and real drinking water treatment conditions in order to evaluate their ability to give rise to transformation products. Two new DBPs from these illicit drugs have been found. A common chlorinated-by-product (3-chlorobenzo)-1,3-dioxole, was identified for both MDA and MDEA while for MDMA, 3-chlorocatechol was found. The presence of these DBPs in water samples collected through drinking water treatment was studied in order to evaluate their formation under real conditions. Both compounds were generated through treatment from raw river water samples containing ATSs at concentration levels ranging from 1 to 15 ng/L for MDA and from 2.3 to 78 ng/L for MDMA. One of them, (3-chlorobenzo)-1,3-dioxole, found after the first chlorination step, was eliminated after ozone and GAC treatment while the MDMA DBP mainly generated after the postchlorination step, showed to be recalcitrant and it was found in final treated waters at concentrations ranging from 0.5 to 5.8 ng/L.  相似文献   

14.
Cho DH  Kong SH  Oh SG 《Water research》2003,37(2):402-408
In many drinking water treatment plants, the chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of trihalomethanes (THMs) such as chloroform, dichlorobromomethane, chlorodibromomethane and bromoform. In this study, headspace-solid-phase microextraction (HS-SPME, 85 microm carboxen/polydimethylsiloxane fiber) technique was applied for the analysis of THMs in drinking water. The effects of experimental parameters such as kinds of SPME fiber, the volume ratio of sample to headspace, the addition of salts, magnetic stirring, extraction temperature, extraction time and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The results of THMs from the survey of Seongnam (Korea) drinking water samples showed that the highest total trihalomethane and chloroform were 24.03 and 13.34 microg/l, which were well within the Korean drinking water quality standard of 100 and 80 microg/l, respectively.  相似文献   

15.
Pintar KD  Slawson RM 《Water research》2003,37(8):1805-1817
The establishment of ammonia-oxidizing bacteria (AOB), a group of autotrophic microorganisms responsible for nitrification in chloraminated distribution systems, was studied in a bench-scale distribution system. The potential significance of temperature and disinfectant residual associated with chloramination in full-scale drinking water distribution systems was assessed. Biofilm development was primarily monitored using AOB abundance and nitrite concentrations. The bench-scale system was initially operated under typical North American summer (22 degrees C) and fall (12 degrees C) temperatures, representing optimal and less optimal growth ranges for these microorganisms. Additional experimentation investigated AOB establishment at a suboptimal winter distribution system temperature of 6 degrees C. The effect of chloramine residual on AOB establishment was studied at higher (0.2-0.6mg/L) and lower (0.05-0.1mg/L) ranges, using a 3:1 (w/w) chlorine:ammonia dosing ratio. Conditions were selected to represent those typically found in a North American distribution system, in areas of low flow and longer retention times, respectively. Finally, the effect of a free chlorine residual on an established nitrifying biofilm was briefly examined. Results clearly indicate that AOB development occurs at all examined temperatures, as well as at selected monochloramine residuals. The maintenance of a disinfectant residual was difficult at times, but was more inhibitory to the nitrifying biofilm than the lower temperature. It can be concluded from the data that nitrification may not be adequately inhibited during the winter months, which may result in more advanced stages of nitrification the following season. Free chlorination can be effective in controlling AOB activity in the short term, but may not prevent reestablishment of a nitrifying biofilm upon return to chloramination.  相似文献   

16.
Stimulated by cholera epidemics in The Netherlands in the second half of the nineteenth century, it was for reasons of public health that public drinking water systems were established. At that stage it was still possible to select unpolluted water resources for the drinking water supply. Even since, the people got an almost unlimited confidence in the quality of their drinking water.Nowadays it becomes more and more difficult for the water companies notto betray this confidence because of the increased pollution of ground and surface water and the technical limitations in purifying this water. In our attempts to remove or to reduce hazardous constituents even other unwanted substance may be introduced into the drinking water.Advanced detection methods for measuring the quality of the water have made suspect nearly all water resources. However, besides getting information about the presence of a suspected constituent one has to know also which concentration in drinking water may be dangerous to public health. In this field a lot of research still has to be done.It is important to realize that in spite of our extended knowledge onpurification systems it is better to rely on wellprotected raw water resources for which ‘relatively simple’ purification methods are sufficient to produce a safe drinking water. The geographical situation of The Netherlands in the delta of the Rhine ans the Meuse does not make it easy to pursue such a policy. International cooperation in cleaning these river basins is a first requisite.  相似文献   

17.
The ability to limit regrowth in drinking water is referred to as biological stability and depends on the concentration of disinfectant residual and on the concentration of substrate required for the growth of microorganisms. The biostability curve, based on this fundamental concept of biological stability, is a graphical approach to study the two competing effects that determine bacterial regrowth in a distribution system: inactivation due to the presence of a disinfectant, and growth due to the presence of a substrate. Biostability curves are a practical, system specific approach for addressing the problem of bacterial regrowth in distribution systems. This paper presents a standardized algorithm for generating biostability curves and this will enable water utilities to incorporate this approach for their site-specific needs. Using data from pilot scale studies, it was found that this algorithm was applicable to control regrowth of HPC in chlorinated systems where AOC is the growth limiting substrate, and growth of AOB in chloraminated systems, where ammonia is the growth limiting substrate.  相似文献   

18.
The occurrence of fifty-five pharmaceuticals, hormones and metabolites in raw waters used for drinking water production and their removal through a drinking water treatment were studied. Thirty-five out of fifty-five drugs were detected in the raw water at the facility intake with concentrations up to 1200 ng/L. The behavior of the compounds was studied at each step: prechlorination, coagulation, sand filtration, ozonation, granular activated carbon filtration and post-chlorination; showing that the complete treatment accounted for the complete removal of all the compounds detected in raw waters except for five of them. Phenytoin, atenolol and hydrochlorothiazide were the three pharmaceuticals most frequently found in finished waters at concentrations about 10 ng/L. Sotalol and carbamazepine epoxide were found in less than a half of the samples at lower concentrations, above 2 ng/L. However despite their persistence, the removals of these five pharmaceuticals were higher than 95%.  相似文献   

19.
There is a growing effort to provide drinking water that has the trust of consumers, but the processes underlying the perception of drinking water quality and risks are still not fully understood. This paper intends to explore the factors involved in public perception of the quality and risks of drinking water. This purpose was addressed with a cross-national mixed-method approach, based on quantitative (survey) and qualitative (focus groups) data collected in the UK and Portugal. The data were analysed using several methods, including structural equation models and generalised linear models. Results suggest that perceptions of water quality and risk result from a complex interaction of diverse factors. The estimation of water quality is mostly influenced by satisfaction with organoleptic properties (especially flavour), risk perception, contextual cues, and perceptions of chemicals (lead, chlorine, and hardness). Risk perception is influenced by organoleptics, perceived water chemicals, external information, past health problems, and trust in water suppliers, among other factors. The use of tap and bottled water to drink was relatively well explained by regression analysis. Several cross-national differences were found and the implications are discussed. Suggestions for future research are provided.  相似文献   

20.
The impact of temperature on nitrification in biological granular activated carbon (GAC) filters was evaluated in order to improve the understanding of the nitrification process in drinking water treatment. The study was conducted in a northern climate where very cold water temperatures (below 2 degrees C) prevail for extended periods and rapid shifts of temperature are frequent in the spring and fall. Ammonia removals were monitored and the fixed nitrifying biomass was measured using a method of potential nitrifying activity. The impact of temperature was evaluated on two different filter media: an opened superstructure wood-based activated carbon and a closed superstructure activated carbon-based on bituminous coal. The study was conducted at two levels: pilot scale (first-stage filters) and full-scale (second-stage filters) and the results indicate a strong temperature impact on nitrification activity. Ammonia removal capacities ranged from 40 to 90% in pilot filters, at temperatures above 10 degrees C, while more than 90% ammonia was removed in the full-scale filters for the same temperature range. At moderate temperatures (4-10 degrees C), the first stage pilot filters removed 10-40% of incoming ammonia for both media (opened and closed superstructure). In the full-scale filters, a difference between the two media in nitrification performances was observed at moderate temperatures: the ammonia removal rate in the opened superstructure support (more than 90%) was higher than in the closed superstructure support (45%). At low temperatures (below 4 degrees C) both media performed poorly. Ammonia removal capacities were below 30% in both pilot- and full-scale filters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号