1.
根据上海的气候条件,以上海地区某写字楼为对象,提出4种太阳能驱动的溴化锂吸收式与电动蒸汽压缩式热泵联合制冷与供暖系统。这4种系统分别由热管式真空管集热器或抛物面槽形聚光集热器,单效或双效溴化锂吸收式制冷机,以及风冷热泵或水源热泵构成。分析比较这4种系统的节能型和经济性的结果表明,采用抛物面槽形聚光集热器+双效溴化锂吸收式制冷机+风冷热泵组成的系统,同时具备较好的节能性与经济性,一次能源利用率可降低约50%。  相似文献   

2.
Solar energy is receiving much more attention in building energy systems in recent years. Solar thermal utilization should be based on integration of solar collectors into buildings. The facades of buildings can be important solar collectors, and, therefore, become multifunctional. In addition, solar collectors can be used to enhance the appearance of the facade when considering their aesthetic compatibility. Currently, installation of collectors on the south tilted roofs, south walls, balconies or awnings of buildings are the feasible approaches for integration of solar collectors into buildings. The most well known solar energy demonstration projects in China are introduced in this paper, which cover different integrated approaches, and solar heating and cooling systems. In China's cities, the process of rebuilding apartment roofs from flat to inclined offers the ideal opportunity to carry out solar renovation in combination with roof-integrated collectors. It can be seen from the demonstration projects over the last twenty years, that, solar cooling systems were mainly used in public buildings for either absorption or adsorption. Besides, nearly all solar cooling systems are multifunctional. They have been used to supply heating and hot water in other seasons for the purpose of high solar fraction. In the 11th Five-year research project (duration 2006–2010), the government has encouraged solar energy researchers to study, develop, and break through the key technologies involved in the integration of solar thermal technologies with buildings.  相似文献   

3.
For absorption cooling systems to operate and produce their cooling effects they need both thermal and electrical energy, while vapor compression systems need electrical energy only. When operating on solar energy the absorption system may receive all its thermal energy needs from solar sources while its electrical needs (parasitic power) are to be supplied from conventional sources. In order to conduct a fair comparison between the two cooling systems, it is proposed to supply both systems with equal amounts of conventional power and to supplement the rest of their needs from solar sources. A solar coefficient of performance, defined as the ratio of the refrigeration effect to the solar radiation input, is introduced and used for comparing some parameters of engineering ane economic importance in both systems. Economic analysis of solar cooling systems indicates that their initial cost is a function of both their design capacities and the number of hours of full load operation required to fulfill the total daily cooling demand. It indicates, also, that the initial cost of both solar cooling systems would break even before the cost of their respective solar conversion devices do.  相似文献   

4.
Although solar energy is able to power the heat-driven refrigeration, its contribution is quite limited due to the conventional cooling requirement. In building air-conditioning, it is common to supply low temperature chilled water, usually in 5–7 °C. If this temperature can be elevated, it would enhance the effectiveness to harness solar energy and minimize auxiliary heating. Solar refrigeration would then be more effective through high temperature cooling, by providing 15–18 °C chilled water instead. In such provision, radiant ceiling cooling can be coupled to handle the space cooling load, particularly space sensible load. And the space latent load and ventilation load are handled by a separate dehumidification provision, like the heat-driven desiccant dehumidification. Therefore, a solar hybrid air-conditioning system is formulated, using adsorption refrigeration, chilled ceilings and desiccant dehumidification. In this study, the year-round performances of the proposed solar hybrid air-conditioning systems were evaluated for two typical office types. The performance metrics include the solar fraction, coefficient of performance, solar thermal gain, primary energy consumption and indoor conditions. Comparative study was conducted for the hybrid air-conditioning system worked with the three common types of chilled ceilings, namely the chilled panels, passive chilled beams and active chilled beams. The solar hybrid air-conditioning system was also benchmarked with the conventional vapour compression refrigeration for office use. It is found that the proposed solar hybrid air-conditioning system is technically feasible through high temperature cooling. Among the three types of chilled ceilings, the passive chilled beams is the most energy-efficient option to work with the solar adsorption refrigeration for space conditioning in the subtropical city.  相似文献   

5.
Large scale heat-driven absorption cooling systems are available in the marketplace for industrial applications but the concept of a solar driven absorption chiller for air-conditioning applications is relatively new. Absorption chillers have a lower efficiency than compression refrigeration systems, when used for small scale applications and this restrains the absorption cooling system from air conditioning applications in residential buildings. The potential of a solar driven ammonia–water absorption chiller for residential air conditioning application is discussed and analyzed in this paper. A thermodynamic model has been developed based on a 10 kW air cooled ammonia–water absorption chiller driven by solar thermal energy. Both energy and exergy analyses have been conducted to evaluate the performance of this residential scale cooling system. The analyses uncovered that the absorber is where the most exergy loss occurs (63%) followed by the generator (13%) and the condenser (11%). Furthermore, the exergy loss of the condenser and absorber greatly increase with temperature, the generator less so, and the exergy loss in the evaporator is the least sensitive to increasing temperature.  相似文献   

6.
A solar hybrid cooling design is proposed for high cooling load demand in hot and humid climate. For the typical building cooling load, the system can handle the zone cooling load (mainly sensible) by radiant cooling with the chilled water from absorption refrigeration, while the ventilation load (largely latent) by desiccant dehumidification. This hybrid system utilizes solar energy for driving the absorption chiller and regenerating the desiccant wheel. Since a high chilled water temperature generated from the absorption chiller is not effective to handle the required latent load, desiccant dehumidification is therefore involved. It is an integration of radiant cooling, absorption refrigeration and desiccant dehumidification, which are powered up by solar energy. In this study, the application potential of the solar hybrid cooling system was evaluated for the high-tech offices in the subtropical climate through dynamic simulation. The high-tech offices are featured with relatively high internal sensible heat gains due to the intensive office electric equipment. The key performance indicators included the solar fraction and the primary energy consumption. Comparative study was also carried out for the solar hybrid cooling system using two common types of chilled ceilings, the passive chilled beams and active chilled beams. It was found that the solar hybrid cooling system was technically feasible for the applications of relatively higher cooling load demand. The annual primary energy consumption of the solar hybrid cooling system was lower than that of the conventional vapour compression refrigeration system up to 36.5%. Between the two options of chilled ceilings, the passive chilled beams were more energy-efficient to work with the solar hybrid cooling system in the hot and humid climate. Harnessing solar energy for driving air-conditioning would help in reducing the carbon emission, hence alleviating the climate change.  相似文献   

7.
A prototype low capacity (10 kW) single stage Li–Br absorption heat pump (AHP), suitable for residential and small building applications has been developed as a collaborative result between various European research institutes and industries. The primary heat source for the AHP is supplied from flat plate solar collectors and the hot/chilled water from the unit is delivered to a floor heating/cooling system. In this paper we present the simulation results and an overview of the performance assessment of the complete system. The calculations were performed for two building types (high and low thermal mass), three climatic conditions, with different types of solar collectors and hot water storage tank sizes and different control systems for the operation of the installation. The simulations were performed using the thermal simulation code TRNSYS. The estimated energy savings against a conventional cooling system using a compression type heat pump was found to be in the range of 20–27%.  相似文献   

8.
Vapour absorption cooling systems, powered by solar thermal energy, are now commercially manufactured in sizes ranging from 1.5 to over 20 RT (one refrigeration ton = 3.51 kW of cooling). The needed thermal energy at appropriate temperature potential can either be provided by solar thermal collectors or else from a solar pond. The paper gives the assessment criteria and results for technical and economic evaluation of the performance of absorption chiller using a solar pond. These results, based on Kuwait's environmental data and costs, have been compared with three alternate cooling systems, namely:
  • 1 Solar thermal collector absorption cooling system.
  • 2 Solar photovoltaic cooling system.
  • 3 Standard vapour compression cooling system.
The criteria, used for performance evaluation of the solar cooling systems on a technical basis, consists of assessing the extent to which such systems can make a positive contribution in a conserving fossil fuel. This is done by first estimating the total electrical energy needed by the standard system (defined in para. 3 above) to produce one unit of cooling output. Solar cooling systems are then analysed and compared with a standard system to establish their electrical energy saving or generation capability, after accounting for the parasitic electrical energy used in pump/fan motors and equivalent energy needed for the production of soft water (used-up in the cooling tower) from seawater desalination. The economic analysis considers the cost and life of subsystems and that of the electrical and water desalination plants to arrive at the unit cooling cost. The unit cooling is defined as the ratio of amortized capital investments plus operation and maintenance costs over the year and the total yearly cooling production by the system. The results show that the solar pond absorption cooling system is the closest competitor to the conventional cooling system.  相似文献   

9.
The OSE Project aims at developing the technology to utilize solar energy for heating, cooling and hot water supply on the basis of various technology for energy conservation in buildings. For the first step of this project a solar heating and cooling system with flat plate collectors and absorption refrigeration machine was installed in a house in 1974. This paper reports outlines of the system and operating results.  相似文献   

10.
In subtropical Hong Kong, solar heat gain via glazing contributes to a significant proportion of the building envelope cooling load. The principal fenestration design includes eliminating direct sunlight and reducing cooling requirements. Daylighting is an effective approach to allow a flexible building façade design strategy, and to enhance an energy-efficient and green building development. This paper studies the lighting and cooling energy performances for a fully air-conditioned open-plan office when solar control films together with daylight-linked lighting controls are being used. Measurements were undertaken at two stages including the electricity expenditures for the office using photoelectric dimming controls only (first stage) and together with the solar control film coatings on the windows (second stage). Electric lighting and cooling energy consumption, transmitted daylight illuminance and solar radiation were systematically recorded and analysed. The measured data were also used for conducting and validating the building energy simulations. The findings showed that the solar film coatings coupled with lighting dimming controls cut down 21.2% electric lighting and 6.9% cooling energy consumption for the open-plan office.  相似文献   

11.
There is a growing, government-led trend of applying renewable energy in Hong Kong. One area of interest lies in the wider use of solar-energy systems. The worldwide fast development of building-integrated solar technology has prompted the design alternative of fixing the solar panels on the external façades of buildings. In Hong Kong, high-rise buildings are found everywhere in the urban districts. How to make full use of the vertical facades of these buildings to capture the most solar radiation can be an important area in the technology promotion. In this numerical study, the potential application of a centralized solar water-heating system in high-rise residence was evaluated. Arrays of solar thermal collectors, that occupied the top two-third of the south and west façades of a hypothetical high-rise residence, were proposed for supporting the domestic hot-water system. Based on typical meteorological data, it was found that the annual efficiency of the vertical solar collectors could reach 38.4% on average, giving a solar fraction of 53.4% and a payback period of 9.2 years. Since the solar collectors were able to reduce the heat transmission through the building envelope, the payback was in fact even shorter if the energy saving in air-conditioner operation was considered.  相似文献   

12.
The thermal performances of solar collectors and solar combi systems with different solar fractions are studied under the influence of the Danish design reference year, DRY data file, and measured weather data from a solar radiation measurement station situated at the Technical University of Denmark in Kgs. Lyngby. The data from DRY data file are used for any location in Denmark. The thermal performances of the solar heating systems are calculated by means of validated computer models. The measured yearly solar radiation varies by approximately 23% in the period from 1990 until 2002, and the investigations show that it is not possible to predict the yearly solar radiation on a tilted surface based on the yearly global radiation.The annual thermal performance of solar combi systems cannot with reasonable approximation be fitted to a linear function of the annual total radiation on the solar collector or the annual global radiation. Solar combi systems with high efficient solar collectors are more influenced by weather variations from one year to another than systems with low efficient solar collectors.The annual thermal performance of solar collectors cannot be predicted from the global radiation, but both the annual thermal performance and the annual utilized solar energy can with a reasonable approximation be fitted to a linear function of the yearly solar radiation on the collector for both flat plate and evacuated tubular solar collectors. Also evacuated tubular solar collectors utilize less sunny years with large parts of diffuse radiation relatively better than flat plate collectors.  相似文献   

13.
14.
15.
Xavier   《Renewable Energy》2006,31(9):1371-1389
In spite of the fact that Spain is one of the EU countries with the highest solar resource on annual basis, the huge seasonal variation in solar radiation availability and the relatively short period with heating demand, make it difficult to reach significant contributions of solar energy to the buildings heating energy demand. This compromises the economic viability of big solar collector areas per capita, and introduces technical difficulties for the dissipation of the excess solar energy available in the summer months. On the other hand, in a large part of the Spanish territory, in other to reach adequate comfort conditions in our buildings, the energy demand for cooling is more important or of the same order than the heating demand. Cooling energy demand is now experiencing a fast growing rate as this comfort requirement becomes internalized. Domestic air conditioning equipments based on vapour compression cycles are being used to reach comfort conditions in some of the rooms of buildings that were designed without taking into account cooling requirements. In spite of their so far small contribution to the total building sector energy demand, these equipments are already imposing important constraints on the environment and the electricity distribution system. Solar absorption cooling arises as an interesting alternative, which at the same time allows reaching a higher solar contribution to the heating demand. However, solar cooling installations present several peculiarities with respect to the more known DHW or even heating installations, which require to incorporate a more detailed approach and additional considerations in the design and performance evaluation processes. Besides, some limitations still persist in solar absorption systems, which could make them loose their market potential for the benefit of other solar cooling options. In this paper, we present some conclusions arising from the experience gained in detailed TRNSYS dynamical simulation of some of the first commercial solar heating and cooling installations recently implemented in Spain, and analyse their perspectives in comparison with other solar cooling options.  相似文献   

16.
When the solar absorption and vapour compression cooling systems are viewed from the point of view of electrical energy consumption the differences between them can be expressed in terms of electrical energy saving with the former. As such, it is proposed that an economic comparison between photovoltaic-assisted vapour compression and solar absorption cooling systems be conducted, assuming that the former receives an amount of solar electricity equal to the potential electrical energy saving with the latter. The comparison is conducted with particular emphasis on the operational conditions in Kuwait. Analysis has shown that the potential electrical energy saving with a solar absorption cooling system is equal to 16 per cent of its refrigeration generation. The cost of supplying an equal amount of solar electricity is compared with the difference between the life-time costs of a solar absorption system and an equivalent vapour compression system. The economic comparison is conducted on the basis of the difference between the net present values of both systems. Given the current cost estimates and the prevailing climatic conditions in Kuwait it is shown that photovoltaic-assisted vapour compression cooling systems are likely to compete with the solar absorption cooling systems. This is particularly true in such applications where cooling is required for few hours during the day, and as the cost of the photovoltaic system decreases.  相似文献   

17.
On a European level there is intense research activity to broaden the applications of solar thermal systems beyond their established domains (hot water, space heating support) and to foster their participation in the energy maps of the EU-Member States. Concentrated Solar Thermal (CST) systems are expected to play a key role in this effort, especially for achieving the medium and high temperatures needed, for electricity generation, for industrial applications but also for hybridized solar heating/cooling and desalination applications.This paper presents a proposal for implementation of a CST system in the building sector, based on a research carried out in the Laboratory of Environmental and Energy Efficient Design of Buildings and Settlements at the University of Thrace. Specifically, an integrated solar cooling system using parabolic trough solar collectors and double-effect chiller is discussed, used to cover the cooling needs of typical office building in Greece.As it was shown, the use of concentrating solar collectors leads to significantly higher output temperatures that can enable the use of two stage absorption chillers with a higher COP. Alternatively, when low or medium temperature heat is required, the use of CST systems takes less space to cope with it than traditional flat plate collectors. The combination of these parameters can contribute to removing key barriers associated with the broader diffusion of solar cooling technology, enhancing the potential to become more competitive to the conventional air conditioning technologies.  相似文献   

18.
The high energy consumption in buildings in Mediterranean countries, especially in the spring and summer months due to the extensive use of air conditioning, requires immediate actions to minimise energy costs and environmental impact given the current energy crisis. Solar cooling systems offer an attractive solution, but the main drawbacks of this type of systems are the low efficiency of the currently used single-effect absorption chillers and the large areas of thermal collectors needed to produce the thermal energy. These large solar installations make difficult their building integration. A way to overcome these difficulties is the use of high efficient integrated solar concentrator systems able to achieve temperatures around 150 °C that could be used to activate the more energy efficient double-effect absorption chillers. In the frame of this concept, in the present work a comparison between two cooling systems for a specific three-floor building, with and without solar concentration, is performed. The first is a conventional system which consists of evacuated tube collectors feeding a single-effect absorption chiller. On the other hand, a Fresnel reflective solar concentrating system, integrated on the building façade, is coupled to a double-effect absorption chiller. The results show an important reduction of the solar collectors absorber area in the concentrating system compared with the standard solar thermal installation. However, the solar concentrating system requires a large aperture area. In addition, the rejected heat in the double-effect chiller is lower, implying that the investment and operation costs of the solar concentrating cooling system can be reduced significantly.  相似文献   

19.
Solar refrigeration represents an important application of solar energy due to the excellent matching between the high sunshine and the refrigeration needs. Solar adsorption refrigeration devices are among the significant techniques used to meet the needs for cooling requirements. Several solar refrigeration systems have been proposed and are under development such as sorption systems including liquid/vapor, solid/vapor absorption, adsorption, vapor compression and others. The purpose of this paper is to identify the influence of a cylindrical adsorber on the performances of a solar adsorption refrigerating machine. The adsorber heated by solar energy contains an activated carbon–ammonia pair; it is composed by many cylindrical tubes welded using external fins. A model based on the conservation equations of energy and mass in the adsorber has been developed and well described. Using real solar irradiance data as well as many initial conditions, the model computes for each point and in the considered time interval during the day, the temperature, the adsorbed mass, the pressure inside the adsorber and the solar performance coefficient (COP). The results show that the optimal diameter of the adsorber with fins is greater than the one without fins. Moreover the mass cycled in the case of an adsorber equipped with external fins is more significant than the one without fins, and the maximal temperature reached in the adsorber with fins attains 97 °C while in the adsorber without fins reaches 77 °C. Thus, the performances of the solar adsorption refrigerating machine with an adsorber equipped with fins are higher than the machine without fins.  相似文献   

20.
This paper investigates the amount of electrical power required, on top of thermal energy needs, in order to generate and deliver the cooling effect of solar absorption cooling systems as compared with the electrical power needs of equivalent vapour compression cooling systems. Further, the effects of degraded operating temperatures and partial load conditions on the power cost per unit of cooling effect in both systems are investigated. It is shown that, under unfavourable conditions, power cost in both systems will be equal. This condition is attained when the two equivalent systems operate at about one-third of their design cooling capacity. It is argued that electrical power saving with solar absorption systems would be improved if a multi-unit configuration is used instead of single unit configuration.  相似文献   