首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The use of solar energy in buildings is an important contribution for the reduction of fossil fuel consumption and harmful emissions to the environment. Solar thermal cooling systems are still in their infancy regarding practical applications, although the technology is sufficiently developed for a number of years. In many cases, their application has been conditioned by the lack of integration between cooling and heating systems. This study aims to evaluate the potential of integrated solar absorption cooling and heating systems for building applications. The TRNSYS software tool was used as a basis for assessment. Different building types were considered: residential, office and hotel. The TRNSYS models are able to run for a whole year (365 days), according to control rules (self-deciding whether to operate in heating or cooling modes), and with the possibility of combining cooling, heating and DHW applications. Three different locations and climates were considered: Berlin (Germany), Lisbon (Portugal), and Rome (Italy). Both energy and economic results are presented for all cases. The different local costs for energy (gas, electricity and water) were taken into account. Savings in CO2 emissions were also assessed. An optimization of solar collector size and other system parameters was also analysed.  相似文献   

2.
In this paper, the simulation of the performance of solar-assisted heating and cooling systems is analyzed. Three different plant layouts are considered: (i) the first one consists of evacuated solar collectors and a single-stage LiBr–H2O absorption chiller; here in order to integrate the system in case of insufficient solar radiation, an electric water-cooled chiller is activated; (ii) configuration of the secondly considered system is similar to the first one, but the absorption chiller and the solar collector area are sized for balancing about 30% of the building cooling load only; (iii) the layout of the thirdly considered system differs from the first one since the auxiliary electric chiller is replaced by a gas-fired heater. Such system configurations also include: circulation pumps, storage tanks, feedback controllers, mixers, diverters and on/off hysteresis controllers.  相似文献   

3.
In this paper, a solar combi-system which consists of solar collectors and a carbon dioxide heat pump is proposed and investigated through simulation and optimization. Performance analysis and comparison are primarily conducted to show the feasibility and reasonability of using a CO2 heat pump as an auxiliary heater under local weather conditions. Then, a system model with a test building in TRNSYS is developed for performance optimization. The most influential variables are identified using influence and sensitivity analyzes of single parameters. Subsequently, a multi-parameter optimization using the high-weight parameters is carried out to obtain a final design result. The simulated results of the optimized case show that the average coefficient of performance of the CO2 heat pump is 2.38, and the solar fraction of the system is 69.0% for the entire heating season. The time when a comfortable temperature level can be achieved in the indoor environment accounts for 81.6% of the entire heating season. Furthermore, the performance characteristics of the proposed system are evaluated in terms of the thermal balance, fraction of the thermal energy saving, feasibility of net zero energy, economic factor, and CO2 emissions reduction.  相似文献   

4.
This paper presents energetic, economic, and environmental (3E) analyses of four configurations of solar heating and cooling (SHC) systems based on coupling evacuated tube collectors with a single-effect LiBr–H2O absorption chiller. In the first configuration (SHC1), a gas-fired heater is used as the back-up system, while a mechanical compression chiller is employed as the auxiliary cooling system in the second configuration (SHC2). The capacity of the absorption chiller is designed based on the maximum building cooling load in these configurations. The third and fourth configurations (SHC3 and SHC4) are similar to SHC2, but the absorption chiller size is reduced to 50% and 20%, respectively. The results show that the highest primary energy saving is achieved by SHC2, leading to a solar fraction of 71.8% and saving 54.51% primary energy as compared to a reference conventional HVAC system. The economic performance of all configurations is still unsatisfactory (without subsidies) due to their high capital costs. However, if a government subsidy of 50% is considered, the results suggest that SHC4 can be economically feasible, achieving a payback period of 4.1 years, net present value of 568,700 AUD and solar fraction of 43%, contributing to 27.16% decrease in the plant primary energy consumption.  相似文献   

5.
In recent years, more and more attention has been paid on the application potential of solar cooling for buildings. Due to the fact that the efficiency of solar collectors is generally low at the time being, the effectiveness of solar cooling would be closely related to the availability of solar irradiation, climatic conditions and geographical location of a place. In this paper, five types of solar cooling systems were involved in a comparative study for subtropical city, which is commonly featured with long hot and humid summer. The solar cooling systems included the solar electric compression refrigeration, solar mechanical compression refrigeration, solar absorption refrigeration, solar adsorption refrigeration and solar solid desiccant cooling. Component-based simulation models of these systems were developed, and their performances were evaluated throughout a year. The key performance indicators are solar fraction, coefficient of performance, solar thermal gain, and primary energy consumption. In addition, different installation strategies and types of solar collectors were compared for each kind of solar cooling system. Through this comparative study, it was found that solar electric compression refrigeration and solar absorption refrigeration had the highest energy saving potential in the subtropical Hong Kong. The former is to make use of the solar electric gain, while the latter is to adopt the solar thermal gain. These two solar cooling systems would have even better performances through the continual advancement of the solar collectors. It will provide a promising application potential of solar cooling for buildings in the subtropical region.  相似文献   

6.
Due to the production of hydrogen, using fuel cells for energy conversion and storing encounters safety problems. Combining high-temperature solid oxide fuel cells with photovoltaic solar panels or zinc oxide solar panels can be a good candidate to produce/convert and store the energy more efficiently for using at peak times. The current paper intends to analyze the efficiency of integration of zinc oxide solar panels and fuel cells to produce hydrogen directly. Therefore, the excess step of converting electricity to hydrogen and re-converting it to electricity, which is customarily used for the integration of the photovoltaic and solid oxide fuel cells, could be skipped. The new method paves the way for providing the required energy for heating/cooling through the floor heating and ceiling cooling systems as well as generating electricity. The article also demonstrates that it is possible to have heat during the day and night for an area of 1920 m2 and 542 m2. It is also possible to create coolness during the day and night for an area of 925 m2 and 260 m2.  相似文献   

7.
Solar space cooling is important in the countries of the Arabian Peninsula where nearly half of the total produced electricity is used for air conditioning of residential commercial and public buildings. In Kuwait, large proportion of funds were allocated for research in solar cooling applications. By the year 1985, several small and medium capacity demonstration projects were installed and tested and more were anticipated for the future. These systems used flat plate collectors and small vapor absorption refrigeration (VAR) system of 5 to 10 tons cooling capacity (TR). The first large installation in Kuwait was carried out in the early eighties for a school building. Immediately thereafter, an equally important installation comprising of 300 m2 of flat plate collector area and three 10 TR VAR chillers, was completed in 1983 for an office building of the Ministry of Defense (MOD). These two well instrumented installations were tested for more than one summer season. The system at MOD is the most successful installation and it has been functioning excellently, to-date. Performance results of the system taken during the summer of 1995 have been presented in this paper.  相似文献   

8.
A cogeneration system consisting of a solar collector, a gas burner, a thermal storage reservoir, a hot water heat exchanger, and an absorption refrigerator is devised to simultaneously produce heating (hot water heat exchanger) and cooling (absorption refrigerator system). A simplified mathematical model, which combines fundamental and empirical correlations, and principles of classical thermodynamics, mass and heat transfer, is developed. The proposed model is then utilized to simulate numerically the system transient and steady state response under different operating and design conditions. A system global optimization for maximum performance (or minimum exergy destruction) in the search for minimum pull-down and pull-up times, and maximum system second law efficiency is performed with low computational time. Appropriate dimensionless groups are identified and the results presented in normalized charts for general application. The numerical results show that the three way maximized system second law efficiency, ηII,max,max,max, occurs when three system characteristic mass flow rates are optimally selected in general terms as dimensionless heat capacity rates, i.e., (ψsp,s,ψwx,wx,ψH,s)opt≅(1.43,0.23,0.14). The minimum pull-down and pull-up times, and maximum second law efficiencies found with respect to the optimized operating parameters are sharp and, therefore important to be considered in actual design. As a result, the model is expected to be a useful tool for simulation, design, and optimization of solar collector based energy systems.  相似文献   

9.
10.
A methodology for deriving an analytical, simplified solar system performance prediction model is presented. Factors related to system design can be examined; for example, storage tank temperature variations, solar system turn-on and turn-off times and system ‘memory’. A simple domestic water heating type system is used as a basis for illustrating derivation of performance models. Predicted performance results are in good agreement with results obtained from another design method. A generalized procedure is described for deriving new system models. The lumped analysis simulation may prove useful for non-standard applications where other simplified design methods are not defined and where detailed simulation capability is not available.  相似文献   

11.
This study outlines the economic feasibility for utilization of solar heating systems for some buildings in the selected typical cities in different climatic regions of Iran. The feasibility of application of the solar heating systems has been determined by means of proper economic criteria and a life time of 25 years for capital investment. It has been found that utilization of such systems could be feasible in some of the regions for specific applications.  相似文献   

12.
A new combined cooling, heating and power (CCHP) system is proposed. This system is driven by solar energy, which is different from the current CCHP systems with gas turbine or engine as prime movers. This system combines a Rankine cycle and an ejector refrigeration cycle, which could produce cooling output, heating output and power output simultaneously. The effects of hour angle and the slope angle of the aperture plane for the solar collectors on the system performance are examined. Parametric optimization is conducted by means of genetic algorithm (GA) to find the maximum exergy efficiency. It is shown that the optimal slope angle of the aperture plane for the solar collectors is 60° at 10 a.m. on June 12, and the CCHP system can reach its optimal performance with the slope angle of 45° for the aperture plane at midday. It is also shown that the system can reach the maximum exergy efficiency of 60.33% under the conditions of the optimal slope angle and hour angle.  相似文献   

13.
In this paper, a transient analysis of a forced circulation solar water heating system with and without heat exchangers in the collector loop and storage tank has been presented for a parallel flat plate collector. The effect of various water heating system parameters on its performance have been studied. Numerical calculations have been made for a typical cold day viz. 26 January 1980 in Delhi.  相似文献   

14.
This paper focuses on the optimization of the performance of a solar absorption cooling system composed by four units with interior energy storage. A full dynamic simulation model that includes the solar collector field, the absorption heat pump system and the building load calculation has been developed. It has been applied to optimize the coupling of a system based on this new technology of solar powered absorption heat pump, to a bioclimatic building recently constructed in the Plataforma Solar de Almeria (PSA) in Spain. The absorption heat pump system considered is composed by four heat pumps that store energy in the form of crystallized salts so that no external storage capacity is required. Each heat pump is composed of two separate barrels that can charge (store energy from the solar field) and discharge (deliver heat or cold to the building) independently. Different configurations of the four units have been analysed taking into account the storage possibilities of the system and its capacity to respond to the building loads. It has been shown how strong the influence of the control strategies in the overall performance is, and the importance of using hourly simulations models when looking for highly efficient buildings.  相似文献   

15.
The influence of the design conditions on the coefficient of performance (COP) of a solar vapour thermal compression chiller was investigated from an operational point of view. Based on a well known model, a number of COP evaluation runs were conducted and the results are presented in graph form as a function of the main design parameters. Through these graphs the influence of the main operating parameters on the performance is quantitatively shown. Finally, the calculated COP is compared to that of a solar absorption system operating under similar conditions.  相似文献   

16.
This paper presents a brief review of the available latent heat storage systems for solar energy utilization. A new concept of latent heat storage of solar energy via the refrigerant-absorbent mass storage in absorption cycle heat pump systems used for solar space heating/cooling has been proposed and assessed thermodynamically. A computer modelling and numerical simulation study shows that the concept of refrigerant storage is fundamentally sound, technically feasible and yields the following advantages over other storage methods: (i) the storage capacity per unit volume is high as the latent heat of vaporization of the refrigerant is high; (ii) the heat loss from the storage to the surroundings is minimum as the storage temperature is near the ambient; (iii) prolonged energy storage is possible with no degradation in system performance and hence suitable for combined solar heating and airconditioning. The effects of operating parameters on the energy storage concentration and storage efficiency have been studied in detail.  相似文献   

17.
A solar pond consisting of honeycomb panels placed on a thin layer (~ 1 cm) of silicone oil floating on the body of a hot water reservoir is considered and analysed for the heat transfer processes in the system. An explicit expression for the transient rate of heat extraction at constant temperature is derived to obtain the annual variation of retrieved heat flux. The year-round thermal performance of the system has been investigated. For a solar pond with a 10 cm high honeycomb structure, annual average efficiencies of 65, 48, 33 and 24% are predicted for retrieved heat flux at temperatures of 40, 60, 80 and 90°C, respectively. A comparison between honeycomb solar pond and salt-gradient solar pond is also presented.  相似文献   

18.
Many state-level Renewable Portfolio Standards (RPS) include preferences for solar generation, with goals of increasing the generation diversity, reducing solar costs, and encouraging local solar industries. Depending on their policy design, these preferences can impact the RPS program costs and emissions reduction. This study evaluates the impact of these policies on costs and emissions, coupling an economic dispatch model with optimized renewable site selection. Three policy designs of an increased RPS in Michigan are investigated: (1) 20% Solar Carve-Out, (2) 5% Distributed Generation Solar Carve-Out, and (3) 3× Solar Multiplier. The 20% Solar Carve-Out scenario was found to increase RPS costs 28%, while the 5% Distributed Generation Solar Carve-Out increased costs by 34%. Both of these solar preferences had minimal impact on total emissions. The 3× Solar Multiplier decreases total RPS program costs by 39%, but adds less than half of the total renewable generation of the other cases, significantly increasing emissions of CO2, NOx, and SO2 relative to an RPS without the solar credit multiplier. Sensitivity analysis of the installed cost of solar and the natural gas price finds small changes in the results of the Carve-Out cases, with a larger impact on the 3× Solar Multiplier.  相似文献   

19.
This paper describes the theoretical rationale for a new low temperature phase-change desalination process, and six examples of applications to illustrate how this process can be engineered for sustainable desalination. In this process, brackish water is evaporated at near-ambient temperatures under near-vacuum pressures created by the barometric head without any mechanical energy input. Thermodynamic advantages and benefits of low temperature phase-change desalination are discussed and results from simulation studies and a prototype test system are presented. Three of the examples illustrate how the proposed process can be driven by solar energy: a) utilizing direct solar energy; b) inclusion of an external reflector; c) utilizing photovoltaic energy during non-sunlight hours. The other examples illustrate how the proposed process can be driven by waste heat: i) waste heat rejected by an absorption refrigeration unit driven by grid power; ii) waste heat rejected by an absorption refrigeration unit driven by solar collectors; and iii) waste heat rejected by an absorption refrigeration unit supported by a photovoltaic array. Merits of utilizing solar energy and process waste heat in reducing energy consumption and greenhouse gas emissions are discussed in detail.  相似文献   

20.
Evacuating the space connecting cover and absorber significantly improves evacuated tube collector (ETC) performance. So, ETCs are progressively utilised all over the world. The main goal of current study is to explore ETC thermal efficiency in hot and severe climate like Kuwait weather conditions. A collector test facility was installed to record ETC thermal performance for one-year period. An extensively developed model for ETCs is presented, employing complete optical and thermal assessment. This study analyses separately optics and heat transfer in the evacuated tubes, allowing the analysis to be extended to different configurations. The predictions obtained are in agreement with experimental. The optimum collector parameters (collector tube length and diameter, mass flow rate and collector tilt angle) are determined. The present results indicate that the optimum tube length is 1.5 m, as at this length a significant improvement is achieved in efficiency for different tube diameters studied. Finally, the heat generated from ETCs is used for solar cooling of a house. Results of the simulation of cooling system indicate that an ETC of area 54 m2, tilt angle of 25° and storage tank volume of 2.1 m3 provides 80% of air-conditioning demand in a house located in Kuwait.  相似文献   