1.
Reichardt J 《Applied optics》2000,39(33):6058-6071
A formalism for the error treatment of lidar ozone measurements with the Raman differential absorption lidar technique is presented. In the presence of clouds wavelength-dependent multiple scattering and cloud-particle extinction are the main sources of systematic errors in ozone measurements and necessitate a correction of the measured ozone profiles. Model calculations are performed to describe the influence of cirrus and polar stratospheric clouds on the ozone. It is found that it is sufficient to account for cloud-particle scattering and Rayleigh scattering in and above the cloud; boundary-layer aerosols and the atmospheric column below the cloud can be neglected for the ozone correction. Furthermore, if the extinction coefficient of the cloud is ?0.1 km(-1), the effect in the cloud is proportional to the effective particle extinction and to a particle correction function determined in the limit of negligible molecular scattering. The particle correction function depends on the scattering behavior of the cloud particles, the cloud geometric structure, and the lidar system parameters. Because of the differential extinction of light that has undergone one or more small-angle scattering processes within the cloud, the cloud effect on ozone extends to altitudes above the cloud. The various influencing parameters imply that the particle-related ozone correction has to be calculated for each individual measurement. Examples of ozone measurements in cirrus clouds are discussed.  相似文献   

2.
提出了一种新的探测对流层低层大气温度的转动拉曼激光雷达方法,通过测量N2和O2的后向散射的纯转动拉曼谱的强度,计算它们的比值来确定大气温度的垂直分布,并对其性能进行了数值模拟。转动拉曼激光雷达的光源是一个调Q的Nd:YAG激光器,经扩束器后输出能量200mJ;采用双光栅单色仪提取所需要的氮气和氧气的转动拉曼谱;接收机采用光电倍增管和双通道光子计数器,量子效率是10%(48000个脉冲累加)。夜晚它对近地面10.2km高度内的探测信噪比在10:1以上,白天它对近地面3.6km高度内的探测信噪比在10:1以上,计算的温度与模拟用的温度真值阔线相差约0.3K。  相似文献   

3.
Pal SR  Bissonnette LR 《Applied optics》1998,37(27):6500-6510
Single-scattering and multiple-scattering lidar signals are calculated for a spaceborne differential absorption lidar system for global ozone measurements at the on and off wavelength pair at 305 and 315 nm. The effect of multiple scattering is found to be negligible on stratospheric and tropospheric ozone retrieval under background stratospheric aerosol. Under low-visibility conditions in the planetary boundary layer the presence of multiple scattering causes an overestimation in maritime aerosol and an underestimation in urban as well as in rural aerosol. This effect is also examined in three cirrus models. The multiple scattering does not permit accurate ozone retrieval within cirrus; however, below it the solution recovers somewhat with generally an underestimation depending on the type and density of cirrus. The effect of aerosol and Rayleigh extinction on the ozone retrieval is also discussed.  相似文献   

4.
An airborne differential absorption lidar (DIAL) system has been developed at the NASA Langley Research Center for remote measurements of atmospheric water vapor (H(2)O) and aerosols. A solid-state alexandrite laser with a 1-pm linewidth and > 99.85% spectral purity was used as the on-line transmitter. Solid-state avalanche photodiode detector technology has replaced photomultiplier tubes in the receiver system, providing an average increase by a factor of 1.5-2.5 in the signal-to-noise ratio of the H(2)O measurement. By incorporating advanced diagnostic and data-acquisition instrumentation into other subsystems, we achieved additional improvements in system operational reliability and measurement accuracy. Laboratory spectroscopic measurements of H(2)O absorption-line parameters were perfo med to reduce the uncertainties in our knowledge of the absorption cross sections. Line-center H(2)O absorption cross sections were determined, with errors of 3-6%, for more than 120 lines in the 720-nm region. Flight tests of the system were conducted during 1989-1991 on the NASA Wallops Flight Facility Electra aircraft, and extensive intercomparison measurements were performed with dew-point hygrometers and H(2)O radiosondes. The H(2)O distributions measured with the DIAL system differed by ≤ 10% from the profiles determined with the in situ probes in a variety of atmospheric conditions.  相似文献   

5.
Bösenberg J 《Applied optics》1998,37(18):3845-3860
A comprehensive formulation of the differential absorption lidar (DIAL) methodology is presented that explicitly includes details of the spectral distributions of both the transmitted and the backscattered light. The method is important for high-accuracy water-vapor retrievals and in particular for temperature measurements. Probability estimates of the error that is due to Doppler-broadened Rayleigh scattering based on an extended experimental data set are presented, as is an analytical treatment of errors that are due to averaging in the nonlinear retrieval scheme. System performance requirements are derived that show that water-vapor retrievals with an accuracy of better than 5% and temperature retrievals with an accuracy of better than 1 K in the entire troposphere are feasible if the error that results from Rayleigh-Doppler correction can be avoided. A modification of the DIAL technique, high-spectral-resolution DIAL avoids errors that are due to Doppler-broadened Rayleigh backscatter and permits simultaneous water-vapor and wind measurements with the same system.  相似文献   

6.
A 2 microm wavelength, 90 mJ, 5 Hz pulsed Ho laser is described with wavelength control to precisely tune and lock the wavelength at a desired offset up to 2.9 GHz from the center of a CO(2) absorption line. Once detuned from the line center the laser wavelength is actively locked to keep the wavelength within 1.9 MHz standard deviation about the setpoint. This wavelength control allows optimization of the optical depth for a differential absorption lidar (DIAL) measuring atmospheric CO(2) concentrations. The laser transmitter has been coupled with a coherent heterodyne receiver for measurements of CO(2) concentration using aerosol backscatter; wind and aerosols are also measured with the same lidar and provide useful additional information on atmospheric structure. Range-resolved CO(2) measurements were made with <2.4% standard deviation using 500 m range bins and 6.7 min? (1000 pulse pairs) integration time. Measurement of a horizontal column showed a precision of the CO(2) concentration to <0.7% standard deviation using a 30 min? (4500 pulse pairs) integration time, and comparison with a collocated in situ sensor showed the DIAL to measure the same trend of a diurnal variation and to detect shorter time scale CO(2) perturbations. For vertical column measurements the lidar was setup at the WLEF tall tower site in Wisconsin to provide meteorological profiles and to compare the DIAL measurements with the in situ sensors distributed on the tower up to 396 m height. Assuming the DIAL column measurement extending from 153 m altitude to 1353 m altitude should agree with the tower in situ sensor at 396 m altitude, there was a 7.9 ppm rms difference between the DIAL and the in situ sensor using a 30 min? rolling average on the DIAL measurement.  相似文献   

7.
Proffitt MH  Langford AO 《Applied optics》1997,36(12):2568-2585
The National Oceanic and Atmospheric Administration Aeronomy Laboratory's rapid tunable daylight differential absorption lidar system for monitoring ozone throughout the free troposphere is described. The system components are optimized to provide continuously and rapidly profiles of ozone, day or night, with a vertical resolution of 1 km and an absolute accuracy of +/-10% to the tropopause under clear sky conditions. Routine observations of ozone with frequent error assessments are made by scanning wavelengths between 286 and 292 nm.  相似文献   

8.
Wang Z  Nakane H  Hu H  Zhou J 《Applied optics》1997,36(6):1245-1252
We present a three-wavelength dual differential absorption lidar (dual-DIAL) method with which one can obtain an accurate stratospheric ozone profile in the presence of volcanic aerosols. Results of theoretical analysis and comparisons with conventional DIAL and backscatter correction methods show that the three-wavelength dual-DIAL method greatly reduces the effect of volcanic aerosol on stratospheric ozone measurements, and system errors that are due to aerosols are kept at a low level. In addition this method is almost completely insensitive to wavelength dependence of aerosol backscatter, its spatial change, and spatial inhomogeneity of aerosol loading. Therefore, one does not need to know detailed information about these aerosol properties, and accurate stratospheric ozone profiles can be obtained directly from lidar return signals. An example of the experimental result indicates that the proposed method is effective.  相似文献   

9.
A method is described for the empirical determination of altitude range resolutions of ozone profiles obtained by differential absorption lidar (DIAL) analysis. The algorithm is independent of the implementation of the DIAL analysis, in particular of the type and order of the vertical smoothing filter applied. An interpretation of three definitions of altitude range resolution is given on the basis of simulations carried out with the Jet Propulsion Laboratory ozone DIAL analysis program, SO3ANL. These definitions yield altitude range resolutions that differ by as much as a factor of 2. It is shown that the altitude resolution calculated by SO3ANL, and reported with all Jet Propulsion Laboratory lidar ozone profiles, corresponds closely to the full width at half-maximum of a retrieved ozone profile if an impulse function is used as the input ozone profile.  相似文献   

10.
Coherent differential absorption lidar measurements of CO2   总被引:6,自引:0,他引:6  
A differential absorption lidar has been built to measure CO2 concentration in the atmosphere. The transmitter is a pulsed single-frequency Ho:Tm:YLF laser at a 2.05-microm wavelength. A coherent heterodyne receiver was used to achieve sensitive detection, with the additional capability for wind profiling by a Doppler technique. Signal processing includes an algorithm for power measurement of a heterodyne signal. Results show a precision of the CO2 concentration measurement of 1%-2% 1sigma standard deviation over column lengths ranging from 1.2 to 2.8 km by an average of 1000 pulse pairs. A preliminary assessment of instrument sensitivity was made with an 8-h-long measurement set, along with correlative measurements with an in situ sensor, to determine that a CO2 trend could be detected.  相似文献   

11.
A sum-frequency-generation system for differential absorption lidar measurement of atmospheric nitrogen dioxide in the lower troposphere was developed. The system uses a combination of a pair of KD*P crystals and a tunable dye laser with LDS 765 dye pumped by the second harmonic of a Nd:YAG laser to generate lambdaon and lambdaoff alternatively. Compared with the conventional system that uses Coumarin 445 dye pumped by the third harmonic, the output energy and long-term stability were improved. By use of this system, atmospheric NO2 concentrations of approximately 10-50 ppb were measured, with an instrumental error of approximately 7 ppb.  相似文献   

12.
Little LM  Papen GC 《Applied optics》2001,40(21):3417-3427
The design and evaluation of a prototype fiber-based lidar system for autonomous measurement of atmospheric water vapor are presented. The system components are described, along with current limitations and options for improvement. Atmospheric measurements show good agreement with modeled signal returns from 400 to 1000 m but are limited below 400 m as a result of errors in signal processing caused by violation of the assumptions used in the derivation of the differential absorption lidar equation.  相似文献   

13.
Gibert F  Flamant PH  Bruneau D  Loth C 《Applied optics》2006,45(18):4448-4458
A 2 microm heterodyne differential absorption lidar (HDIAL) has been operated at the Inst?tut Pierre Simon Laplace, Laboratoire de Météorologie Dynamique (Paris) to monitor the CO(2) mixing ratio in absolute value at high accuracy in the atmospheric boundary layer. Horizontal measurements at increasing range are made to retrieve the optical depth. The experimental setup takes advantage of a heterodyne lidar developed for wind velocity measurements. A control unit based on a photoacoustic cell filled with CO(2) is tested to correct afterward for ON-line frequency drift. The HDIAL results are validated using in situ routine measurements. The Doppler capability is used to follow the change in wind direction in the Paris suburbs.  相似文献   

14.
The performance of a spaceborne temperature lidar based on the pure rotational Raman (RR) technique in the UV has been simulated. Results show that such a system deployed onboard a low-Earth-orbit satellite would provide global-scale clear-sky temperature measurements in the troposphere and lower stratosphere with precisions that satisfy World Meteorological Organization (WMO) threshold observational requirements for numerical weather prediction and climate research applications. Furthermore, nighttime temperature measurements would still be within the WMO threshold observational requirements in the presence of several cloud structures. The performance of aerosol extinction measurements from space, which can be carried out simultaneously with temperature measurements by RR lidar, is also assessed. Furthermore, we discuss simulations of relative humidity measurements from space obtained from RR temperature measurements and water-vapor data measured with the differential absorption lidar (DIAL) technique.  相似文献   

15.
16.
Langford AO 《Applied optics》1995,34(36):8330-8340
Differential absorption lidar (DIAL) is a powerful remote-sensing technique widely used to probe the spatial and temporal distribution of ozone and other gaseous atmospheric trace constituents. Although conceptually simple, the DIAL technique presents many challenging and often subtle technical difficulties that can limit its useful range and accuracy. One potentially serious source of error for many DIAL experiments is nonlinearity in the analog-to-digital converters used to capture lidar return signals. The impact of digitizer nonlinearity on DIAL measurements is examined, and a simple and inexpensive low-frequency dithering technique that significantly reduces the effects of ADC nonlinearity in DIAL and other applications in which the signal is repetitively averaged is described.  相似文献   

17.
Ancellet G  Ravetta FO 《Applied optics》1998,37(24):5509-5521
An airborne lidar has been developed for tropospheric ozone monitoring. The transmitter module is based on a solid-state Nd:YAG laser and stimulated Raman scattering in deuterium to generate three wavelengths (266, 289, and 316 nm) that are used for differential ozone measurements. Both analog and photon-counting detection methods are used to produce a measurement range up to 8 km. The system has been flown on the French Fokker 27 aircraft to perform both lower tropospheric (0.5-4-km) and upper tropospheric (4-12-km) measurements, with a 1-min temporal resolution corresponding to a 5-km spatial resolution. The vertical resolution of the ozone profile can vary from 300 to 1000 m to accommodate either a large-altitude range or optimum ozone accuracy. Comparisons with in situ ozone measurements performed by an aircraft UV photometer or ozone sondes and with ozone vertical profiles obtained by a ground-based lidar are presented. The accuracy of the tropospheric ozone measurements is generally better than 10-15%, except when aerosol interferences cannot be corrected. Examples of ozone profiles for different atmospheric conditions demonstrate the utility of the airborne lidar in the study of dynamic or photochemical mesoscale processes that control tropospheric ozone.  相似文献   

18.
The availability of new laser sources that are tunable in the IR spectral region opens new perspectives for differential absorption lidar (DIAL) measurements. A region of particular interest is located in the near IR, where some of the atmospheric pollutants have absorption lines that permit monitoring of emissions from industrial plants and in urban areas. In DIAL measurements, the absorption lines for the species to be measured must be carefully chosen to prevent interference from other molecules, to minimize the dependence of the absorption cross section on temperature, and to optimize the measurements with respect to the optical depth. We analyze the influence of these factors and discuss a set of criteria for selecting the best pairs of wavelengths (lambda(on) and lambda(off)) to be used in DIAL measurements of several molecular species (HCl, CO, CO(2), NO(2), CH(4), H(2)O, and O(2)). Moreover, a sensitivity study has been carried out for selected lines in three different regimes: clean air, urban polluted air, and emission from an incinerator stack.  相似文献   

19.
An a posteriori corrective method based on photo-acoustic cell (PAC) information is proposed to correct for laser transmitter spectral shift during atmospheric CO(2) measurements by 2 microm heterodyne differential absorption lidar (HDIAL) technique. The method for using the PAC signal to retrieve the actual atmospheric CO(2) absorption is presented in detail. This issue is tackled using a weighting function. The performance of the proposed corrective method is discussed and the various sources of error associated with the PAC signal are investigated. For 300 shots averaged and a frequency shift (from the CO(2) absorption line center) lower than the CO(2) absorption line half-width, the relative error on HDIAL CO(2) mixing ratio measurements is lower than 1.3%. The corrective method is validated in absolute value by comparison between HDIAL and in situ sensor measurements of CO(2).  相似文献   

20.
From lidar signals detected with a shot per shot differential absorption lidar instrument tuned for tropospheric ozone measurements and recording each individual return, we reconstruct histograms of their sampled values for each channel of our digitizers. The analysis of their shape permits the correction of our measurements for experimental biases. In particular, a negative correlation is found between the skew of the histograms and the intensity of the backscattered light. The skew comes from a tail at high sampled values, interpreted as due to a raise of the relative contribution to the signal of a signal-induced noise when this intensity diminishes. By fitting a Gaussian function to the histograms without considering their tails, we calculate average signals unbiased by the corresponding noise. This approach allows us to increase the range of our ozone profiles, up to as much as double it in some cases.  相似文献   