首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Imaging of a coimmobilized diaphorase and albumin surface was investigated by scanning electrochemical microscopy (SECM) with shear force based tip-substrate distance control. A microelectrode tip was attached to a commercially available tuning fork to detect the shear force between the microelectrode tip and the surface. We used the standing approach mode, which repeats an approach and retraction at each data point of the surface to obtain simultaneous current and topographic images. To check the performance of our SECM system, we imaged a platinum-patterned array electrode and a diaphorase/albumin coimmobilized glass surface. Since the system acquires current when the tip is retracted to a desired distance, this mode is useful for a relatively large microelectrode (approximately 10 microm) and for scanning a large area (few hundreds of micrometers). Furthermore, by retracting the tip when the tip moves laterally to the next data point to avoid contact between the tip and sample surface, we successfully imaged the surface without destroying its morphology.  相似文献   

2.
Lee Y  Bard AJ 《Analytical chemistry》2002,74(15):3626-3633
A technique that combines scanning electrochemical microscopy (SECM) and optical microscopy (OM) was implemented with a new probe tip. The tip for scanning electrochemicaVoptical microscopy (SECM/OM) was constructed by insulating a typical gold-coated near-field scanning optical microscopy tip using electrophoretic anodic paint. Once fabricated, the tip was characterized by steady-state cyclic voltammetry, as well as optical and electrochemical approach experiments. This tip generated a stable steady-state current and well-defined SECM approach curves for both conductive and insulating substrates. Durable tips whose geometry was a ring with < 1 microm as outer ring radius could be consistently fabricated. Simultaneous electrochemical and optical images of an interdigitated array electrode were obtained with a resolution on the micrometer scale, demonstrating good performance of the tip as both an optical and an electrochemical probe for imaging microstructures. The SECM feedback current measurements were successfully employed to determine tip-substrate distances for imaging.  相似文献   

3.
We have already reported a method for fabricating ultramicroelectrodes (Suzuki, K. JP Patent, 2004-45394, 2004). This method is based on the selective chemical etching of optical fibers. In this work, we undertake a detailed investigation involving a combination of etched optical fibers with various types of tapered tip (protruding-shape, double- (or pencil-) shape and triple-tapered electrode) and insulation with electrophoretic paint. Our goal is to establish a method for fabricating nanometer-sized optical fiber electrodes with high reproducibility. As a result, we realized pencil-shaped and triple-tapered electrodes that had radii in the nanometer range with high reproducibility. These nanometer-sized electrodes showed well-defined sigmoidal curves and stable diffusion-limited responses with cyclic voltammetry. The pencil-shaped optical fiber, which has a conical tip with a cone angle of 20 degrees , was effective for controlling the electrode radius. The pencil-shaped electrodes had higher reproducibility and smaller electrode radii (r(app) < 1.0 nm) than those of other etched optical fiber electrodes. By using a pencil-shaped electrode with a 105-nm radius as a probe, we obtained simultaneous electrochemical and optical images of an implantable interdigitated array electrode. We achieved nanometer-scale resolution with a combination of scanning electrochemical microscopy SECM and optical microscopy. The resolution of the electrochemical and optical images indicated sizes of 300 and 930 nm, respectively. The neurites of living PC12 cells were also successfully imaged on a 1.6-microm scale by using the negative feedback mode of an SECM.  相似文献   

4.
A batch fabrication process at the wafer-level integrating ring microelectrodes into atomic force microscopy (AFM) tips is presented. The fabrication process results in bifunctional scanning probes combining atomic force microscopy with scanning electrochemical microscopy (AFM-SECM) with a ring microelectrode integrated at a defined distance above the apex of the AFM tip. Silicon carbide is used as AFM tip material, resulting in reduced mechanical tip wear for extended usage. The presented approach for the probe fabrication is based on batch processing using standard microfabrication techniques, which provides bifunctional scanning probes at a wafer scale and at low cost. Additional benefits of batch fabrication include the high processing reproducibility, uniformity, and tuning of the physical properties of the cantilever for optimized AFM dynamic mode operation. The performance of batch-fabricated bifunctional probes was demonstrated by simultaneous imaging micropatterned platinum structures at a silicon dioxide substrate in intermittent (dynamic) and contact mode, respectively, and feedback mode SECM. In both, intermittent and contact mode, the bifunctional probes provided reliable correlated electrochemical and topographical data. In addition, simulations of the diffusion-limited steady-state currents at the integrated electrode using finite element methods were performed for characterizing the developed probes.  相似文献   

5.
The fabrication and characterization of novel micropipet probes for use in scanning electrochemical microscopy (SECM) are described. These can be used to dispense small (pL) amounts of a solution while monitoring the electrochemical response at a substrate and at a ring electrode tip on the micropipet probe. The probes were constructed by insulating gold-coated borosilicate micropipets with electrophoretic paint and exposing a ring electrode at the tip by heat treatment. Characterization of the probes was performed using scanning electron microscopy, cyclic voltammetry, and SECM approach curve experiments. Routine construction of tips with diameters of the order of 3 microm was possible using this technique. The probes exhibited stable steady-state currents and positive and negative feedback approach curves that agreed with those predicted by theory. Demonstrative SECM imaging experiments were performed using a picodispenser to continuously dispense an electroactive solution (ferrocenemethanol) to the SECM cell while the probe was located within a few micrometers of a Pt substrate surface. Oxidation of the dispensed electroactive solution was performed at the substrate, and feedback currents were measured at the probe tip by holding the gold ring at a reducing potential. This mode of tip-dispensing SECM was used to obtain images of a platinum substrate electrode while monitoring both the substrate current and the feedback current at the probe.  相似文献   

6.
Local feedback mode is introduced as a novel operation mode of scanning electrochemical microscopy (SECM) for electrochemical characterization of a single one-dimensional (1D) nanostructure, for example, a wire, rod, band, and tube with 1-100-nm width and micrometer to centimeter length. To demonstrate the principle, SECM feedback effects under diffusion limitation were studied theoretically and experimentally with a disk probe brought near a semi-infinitely long band electrode as a geometrical model for a conductive 1D nanostructure. As the band becomes narrower than the disk diameter, the feedback mechanism for tip current enhancement is predicted to change from standard positive feedback mode, to positive local feedback mode, and then to negative local feedback mode. The negative local feedback effect is the only feedback effect that allows observation of a 1D nanostructure without serious limitations due to small lateral dimension, available tip size, or finite electron-transfer rate. In line-scan and approach-curve experiments, an unbiased Pt band electrode with 100-nm width and 2.6-cm length was detectable in negative local feedback mode, even using a 25-microm-diameter disk Pt electrode. Using a 2-microm-diameter probe, both well-defined and defected sites were observed in SECM imaging on the basis of local electrochemical activity of the nanoband electrode. Noncontact and spatially resolved measurement is an advantage of this novel SECM approach over standard electrochemical approaches using electrodes based on 1D nanostructure.  相似文献   

7.
Combined scanning electrochemical atomic force microscopy (SECM-AFM) is a recently introduced scanned probe microscopy technique where the probe, which consists of a tip electrode and integrated cantilever, is capable of functioning as both a force sensor, for topographical imaging, and an ultramicroelectrode for electrochemical imaging. To extend the capabilities of the technique, two strategies for noncontact amperometric imaging-in conjunction with contact mode topographical imaging-have been developed for the investigation of solid-liquid interfaces. First, SECM-AFM can be used to image an area of the surface of interest, in contact mode, to deduce the topography. The feedback loop of the AFM is then disengaged and the stepper motor employed to retract the tip a specified distance from the sample, to record a current image over the same area, but with the tip held in a fixed x-y plane above the surface. Second, Lift Mode can be employed, where a line scan of topographical AFM data is first acquired in contact mode, and the line is then rescanned to record SECM current data, with the tip maintained at a constant distance from the target interface, effectively following the contours of the surface. Both approaches are exemplified with SECM feedback and substrate generation-tip collection measurements, with a 10-microm-diameter Pt disk UME serving as a model substrate. The approaches described allow electrochemical images, acquired with the tip above the surface, to be closely correlated with the underlying topography, recorded with the tip in intimate contact with the surface.  相似文献   

8.
The oxygen reduction reaction (ORR) in acidic medium was studied on different electrode materials by scanning electrochemical microscopy (SECM) operating in a new variation of the tip generation-substrate collection mode. An ultramicroelectrode tip placed close to the substrate electrode oxidizes water to oxygen at a constant current. The substrate is held at a potential where the tip-generated oxygen is reduced and the resulting substrate current is measured. By changing the substrate potential, it is possible to obtain a polarization (current-potential) curve, which depends on the electrocatalytic activity of the substrate material. The main difference between this mode and the classical feedback SECM mode of operation is that the feedback diffusion process is not required for the measurement, allowing its application for studying the ORR in acidic solutions. Activity-sensitive images of heterogeneous surfaces, e.g., with Pt and Au electrodes, were obtained from the substrate current when the x-y plane was scanned with the tip. The usefulness of this technique for imaging electrocatalytic activity of smooth metallic electrodes and of highly dispersed fuel cell-type electrocatalysts was demonstrated. The application of this method to the combinatorial chemical analysis of electrode materials and electrocatalysts is discussed.  相似文献   

9.
On the basis of an experimentally validated simple theoretical model, it is demonstrated unambiguously that when an unbiased conductor is probed by a scanning electrochemical tip (scanning electrochemical microscopy, SECM), it performs as a bipolar electrode. Though already envisioned in most recent SECM theories, this phenomenon is generally overlooked in SECM experimental investigations. However, as is shown here, this may alter significantly positive feedback measurements when the probed conductor is not much larger than the tip.  相似文献   

10.
A new generation of platinum nanoelectrodes for constant-distance mode scanning electrochemical microscopy (CD-SECM) has been prepared, characterized, and used for high spatial resolution electrochemical measurements and visualization of electrochemically induced concentration gradients in microcavities. The probes have long (1-2 cm), narrow quartz tips that were conically polished and have a Pt nanoelectrode that is slightly offset from center. Because of the size and location of the electrode on the probe, it does not exhibit SECM feedback while approaching the analyzed sample surfaces even to distances within a few hundred nanometers. The probe was positioned near the surface while scanning and performing electrochemical measurements through use of nonoptical shear force control of the tip-to-sample distance. Test structures consisted of cylindrically shaped microcavities that are 50 microm in diameter with three individually addressable electrodes: a gold disk at 8-microm depth, a crescent-shaped gold ring at 4-microm depth along the wall, and a top gold electrode at the rim. Different electrodes within the microcavity were used to reduce and oxidize redox species in 250 microL of a solution of 5 mM hexaamineruthenium(III) chloride and 0.1 M potassium chloride, protected from evaporation by mineral oil, while the SECM tip followed the topography of the structures and monitored the current from the oxidation of [Ru(NH3)6]2+. Electrochemically generated concentration profiles were obtained from these complex test structures that are not possible with any other SECM technology at this time.  相似文献   

11.
Epithelial cell monolayers from rat kidney were imaged by scanning electrochemical microscopy (SECM) with sub-micrometer resolution in both lateral and vertical direction. Platinum disk ultra-microelectrodes (UMEs) with effective electrode radii between 200 and 600 nm were operated in the constant-height mode. The quality of the recorded SECM images compare favorably with those of phase contrast and confocal laser scanning microscopy. Besides the acquisition of SECM images, the UME was used to selectively attack a single living cell within the monolayer ensemble. Hydroxide ions were locally generated in the vicinity of a single target cell by the UME. The increase in pH induced cell necrosis that was subsequently imaged by SECM. It could be clearly demonstrated that the single target cell was selectively affected, whereas the adjacent reference cells remained unchanged.  相似文献   

12.
Zu Y  Ding Z  Zhou J  Lee Y  Bard AJ 《Analytical chemistry》2001,73(10):2153-2156
Electrogenerated chemiluminescence at electrodes with effective diameters down to 155 nm was used as a stable light source for near-field scanning optical microscopy imaging of an interdigitated array and a submicrometer size test substrate. Light was generated in a thin (approximately 500 microm) layer of an aqueous solution of 15 mM Ru(bpy)3(2+) and 100 mM tri-n-propylamine in a pH 7.5 buffer. The resolution obtained was compared to that found with a micrometer size electrode. The shear force from the tip attached to a quartz tuning fork was used to monitor and control the tip-to-substrate separation within the near field regime.  相似文献   

13.
Positionable voltammetric cells with tip diameters of < 50 microm were constructed from theta glass capillaries. One channel of the pulled glass capillary contains a carbon fiber microelectrode sealed in epoxy while the other houses a Ag/AgCl reference electrode that makes electrical contact to the analyte solution via a salt bridge at the tip. The device can be operated as a two-electrode cell and can therefore make measurements in droplets of solution that are similar in size to the tip. Alternatively, if the droplet of solution is larger than the tip, spatially resolved measurements of a substrate in solution can be made. Voltammetric experiments and feedback imaging with the scanning electrochemical microscope (SECM) were accomplished in microdroplets with solution volumes of less than 1 nL. pH images of a substrate immersed in 70-microL-thick films of solution were obtained in the generator-collector mode of SECM using an iridium oxide-modified microcell. This type of microcell is particularly useful for making electrochemical measurements in very small droplets of solution where a mobile working electrode could easily collide with a separately positioned reference electrode.  相似文献   

14.
The electrochemical behavior of electrodes made by sealing carbon nanofibers in glass or with electrophoretic paint has been studied by scanning electrochemical microscopy (SECM). Because of their small electroactive surface area, conical geometry with a low aspect ratio and high overpotential for proton and oxygen reduction, carbon nanofiber (CNF) electrodes are promising candidates for producing electrode nanogaps, imaging with high spatial resolution and for the electrodeposition of single metal nanoparticles (e.g., Pt, Pd) for studies as electrocatalysts. By using the feedback mode of the SECM, a CNF tip can produce a gap that is smaller than 20 nm from a platinum disk. Similarly, the SECM used in a tip-collection substrate-generation mode, which subsequently shows a feedback interaction at short distances, makes it possible to detect a single CNF by another CNF and then to form a nanometer gap between the two electrodes. This approach was used to image vertically aligned CNF arrays. This method is useful in the detection in a homogeneous solution of short-lifetime intermediates, which can be electrochemically generated at one electrode and collected at the second at distances that are equivalent to a nanosecond time scale.  相似文献   

15.
Alternating current impedance imaging of a 6-microm thick membrane containing conical-shaped pores (60-nm and 2.5-microm diameter openings) using scanning electrochemical microscopy (SECM) is described. Impedance images of the pore openings were obtained by rastering a glass-sealed conically shaped Pt tip (approximately 1-microm radius) above the membrane surface, while measuring the total impedance between the tip and a large area Pt electrode located on the opposite side of the membrane. Individual pore openings in the high pore density membrane (approximately 8 x 10(4) pores/cm2) are observed in the SECM impedance image. The image contrast is due to the decrease in tip and membrane resistance, in the vicinity of the pore opening. An equivalent circuit for the SECM cell and membrane is proposed and evaluated against the measured SECM imaging impedance. Criteria for employing SECM in impedance mode to image membranes are discussed.  相似文献   

16.
A scanning electrochemical microscopy (SECM) methodology for localized quantitative kinetic studies of electrode reactions based on the tip generation-substrate collection (TG-SC) operation mode is presented. This approach does not use the mediator feedback required in typical kinetic SECM experiments. The reactant is galvanostatically electrogenerated on a tip placed in proximity to the substrate. It diffuses through the tip-substrate gap and undergoes the reaction of interest on the substrate surface. The substrate current is monitored with time until it reaches an apparent steady-state value. The process was digitally simulated using an explicit finite difference method, for an irreversible first-order electrode reaction at the substrate. Transient responses, steady-state polarization curves, and TG-SC approach curves can be used to obtain substrate kinetics. The effects of the experimental parameters were analyzed. The possibility of easily changing the experimental conditions with the SECM is an attractive approach to obtain independent evidence that can be used for a strict test of reaction mechanisms. The technique was applied for a preliminary simplified kinetic examination of the oxygen reduction reaction in phosphoric acid.  相似文献   

17.
In this paper, we present a technique to rapidly and directly examine ultramicroelectrodes (UMEs) by white light vertical scanning interferometry (VSI). This technique is especially useful in obtaining topographic information with nanometer resolution without destruction or modification of the UME and in recognizing tips where the metal is recessed below the insulating sheath. Two gold UMEs, one with a metal radius a = 25 μm and relative insulating sheath radius RG = 2 and the other with a = 5 μm and RG = ~1.5, were examined, and the average depth of the gold recessions was determined to be 1.15 μm and 910 nm, respectively. Electrodeposition of gold was performed to fill the recessed hole, and the depth was reduced to ~200 nm. With the electrodeposited gold electrode and a conventional microelectrode (a = 25 μm) as a tip and substrate, respectively, a tip/substrate distance, d, of 600 nm was achieved allowing scanning electrochemical microscopy (SECM) in positive feedback mode at a close distance, which is useful for measuring fast kinetics.  相似文献   

18.
We describe a wet process for the fabrication of poly(tetrafluoroethylene) (PTFE)-covered electrodes in which arrays of holes ( approximately 200 microm) are formed. The PTFE coating provides electrical insulation of most of the electrode surface with selected regions exposed for electrochemical experiments. The arrays of microholes can be controllably patterned and filled with precursor solutions using a piezoelectric dispenser. A micrometer spot of electrocatalyst is produced after reduction of the precursor. The application is tested for scanning electrochemical microscopy (SECM) in the tip generation-substrate collection (TG-SC) studies of electrocatalysts. The method is shown to reduce the substrate background currents that are included in the electrochemical signal read from the local perturbation induced with the SECM tip to the substrate in the TG-SC mode of SECM. This background current reduction is consistent with the decrease in the exposed area of the electrode. The general methodology for the fabrication of the substrate electrodes and two proof-of-concept applications in the TG-SC SECM modality are described.  相似文献   

19.
A combined scanning electrochemical microscope (SECM)-atomic force microscope (AFM) is described. The instrument permits the first simultaneous topographical and electrochemical measurements at surfaces, under fluid, with high spatial resolution. Simple probe tips suitable for SECM-AFM, have been fabricated by coating flattened and etched Pt microwires with insulating, electrophoretically deposited paint. The flattened portion of the probe provides a flexible cantilever (force sensor), while the coating insulates the probe such that only the tip end (electrode) is exposed to the solution. The SECM-AFM technique is illustrated with simultaneous electrochemical-probe deflection approach curves, simultaneous topographical and electrochemical imaging studies of track-etched polycarbonate ultrafiltration membranes, and etching studies of crystal surfaces.  相似文献   

20.
The theory of the feedback mode of scanning electrochemical microscopy is extended for probing heterogeneous electron transfer at an unbiased conductor. A steady-state SECM diffusion problem with a pair of disk ultramicroelectrodes as a tip and a substrate is solved numerically. The potential of the unbiased substrate is such that the net current flow across the substrate/solution interface is zero. For a reversible substrate reaction, the potential and the corresponding tip current depend on SECM geometries with respective to the tip radius including not only the tip-substrate distance and the substrate radius but also the thickness of the insulating sheath surrounding the tip. A larger feedback current is obtained using a probe with a thinner insulating sheath, enabling identification of a smaller unbiased substrate with a radius that is approximately as small as the tip radius. An intrinsically slow reaction at an unbiased substrate as driven by a SECM probe can be quasi-reversible. The standard rate constant of the substrate reaction can be determined from the feedback tip current when the SECM geometries are known. The numerical simulations are extended to an SECM line scan above an unbiased substrate to demonstrate a "dip" in the steady-state tip current above the substrate center. The theoretical predictions are confirmed experimentally for reversible and quasi-reversible reactions at an unbiased disk substrate using disk probes with different tip radii and outer radii.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号