《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

2.
A 10N·m dead weight torque standard machine (10-N·m-DWTSM) has been developed and evaluated since 2006 at the National Metrology Institute of Japan (NMIJ), a part of the National Institute of Advanced Industrial Science and Technology (AIST). Previously, the lengths of a moment arm, made of a low-thermal-expansion alloy (Super Invar), and the sensitivity limit of the fulcrum were evaluated. However, it is known that mechanical parts made of Super Invar vary in size with time. Therefore, the sensitivity limit of the fulcrum should be investigated under real calibration conditions. In this study, the moment arm lengths and the sensitivity limit of the fulcrum were re-evaluated. The moment arm lengths were found to have increased by an average of 6.3 μm in five years. The relative combined standard uncertainty of the moment arm length, warm, was re-evaluated in consideration of the uncertainty of the secular length change and was found to be 1.8 × 10−5. The sensitivity limit of the fulcrum was investigated by using a highly accurate, small-rated-capacity torque measuring device. The relative combined standard uncertainty due to the sensitivity limit of the fulcrum was 2.5 × 10−5 in the 0.1–10N·m torque range. The uncertainty budget table of the 10-N·m-DWTSM was completed. The relative expanded uncertainty of torque realized by the 10-N·m-DWTSM, Wtsm, was evaluated in the 0.1–10N·m torque range and was found to be 6.6 × 10−5, with a coverage factor, k, being equal to 2. In addition, the 10-N·m-DWTSM was compared with the existing 1-kN·m-DWTSM at NMIJ by using small-rated-capacity torque measuring devices at 5N·m and 10N·m torque steps. Two loading conditions were adopted in this comparison. The comparison results showed good agreement within the uncertainties in all cases. Thus, the torque realized by the 10-N·m-DWTSM was shown to be equivalent to that achieved by the 1-kN·m-DWTSM.  相似文献   

3.
Ion implantation has found to be an effective approach to modify surface properties of materials. The present research investigates the effect of (1) nitrogen (N), and (2) carbon subsequently with nitrogen (C + N) implantations on the mechanical and tribological properties of the titanium–aluminium–silicon–nitride (Ti–Al–Si–N) coatings. Superhard TiAlSiN coatings produced by magnetron sputtering, of approximately 2.5 μm thickness, were post-treated by implantations of N or C + N at an energy level of 50 keV. The dose range was between 5 × 1016 and 1 × 1018 ions cm?2. After implantation, the tribological performance of the coatings was investigated by a ball-on-disk tribometer against WC–6 wt.%Co ball under dry condition in ambient air. The wear performance of the samples was examined by a variety of characterization techniques, such as secondary electron microscopy (SEM), 3D profilometry, atomic force microscopy (AFM), and micro-Raman. The results showed that the wear performance of the samples depended strongly on the implanted elements and doses. There was slight improvement on the samples implanted with N whereas significant improvement was found on the C + N implantations. Particularly, the friction coefficient of the sample with 5 × 1017 C+ cm?2 and 5 × 1017 N+ cm?2 could reach 0.1. In addition, the specific wear rate of the sample was extremely low (0.85 × 10?7 mm3/Nm), which was nearly two orders of magnitude below that of the un-implanted coating. The speculation of the mechanical and tribological analyses of the samples indicates that the improvement of the N implanted and C + N implanted TiAlSiN samples could be due to a combined effect of improved hardness, plus enhanced adhesive and cohesive strength. In addition, the improved performance of the C + N implanted samples could be explained by the formation of lubricating implanted-layer, which existed mostly in sp2 C–C and C–N forms. The formation of such implanted layer could lead to a change of wear mode from strong abrasive wear to mostly adhesive wear, and result in a drop of friction coefficient and wear rate.  相似文献   

4.
We developed a promising shearing force sensor that is small in size and can measure shearing force along two axes independently. This sensor consists of an elastic gum frame and an optical sensor chip (6 mm × 6 mm × 8 mm). From the experimental results, the resolutions of the sensor along the x- and y-axes are found to be 0.070 N and 0.063 N. We also experimentally demonstrated that the sensor can separately measure shearing force along two axes. Finally, we demonstrated that the scale factor which correspond to resolution and linear portion which correspond to measuring range of the signals can be changed easily by using three types of elastic gum frame. This sensor can be embedded in the finger of a robot hand and use it to not only measure shearing force but also detect the slip phenomenon.  相似文献   

5.
A deadweight force standard machine is a mechanical structure that generates force by subjecting deadweights to the local gravitational field. The Korea Research Institute of Standards and Science (KRISS) developed and installed a 100 kN deadweight force standard machine for national force standards. It can generate forces from 2 kN to 110 kN in increments of 1 kN. The uncertainty of the force machine was estimated and declared as 2 × 10−5. This 100 kN deadweight force machine was compared with the 500 kN deadweight force standard machine at KRISS and the 20 kN and 50 kN deadweight force standard machines at the National Metrology Institute of Japan (NMIJ). The measurement results showed good agreement between the deadweight force machines, and the accuracy level of the 100 kN deadweight force machine was verified.  相似文献   

6.
We report on the design, construction and evaluation of a low-cost digital environmental monitoring system based on a popular micro-computer board and mass market digital sensors. The system is based around the use of open source software and readily available digital sensors, providing key parameters required for environmentally-controlled calibration laboratories: air temperature, pressure and humidity. Each system logs data at set intervals with front-panel display, web page graphical display and email alerting when exceeding set tolerances. The sensors have been calibrated at the National Physical Laboratory using standards traceable to the SI. Long term stability of the system is estimated and in addition to monitoring of laboratory environments for regulatory purposes, the systems can also be used to provide on-demand values for local refractive index with an expanded (k = 2) uncertainty of 1.1 × 10−7 as required for many optical-based measuring systems.  相似文献   

7.
《Measurement》2007,40(7-8):741-745
In this paper, we investigate the characteristics of a piezoresistive AFM cantilever in the range of 0–1.6 μN by using nano force calibrator (NFC), which consists of a high precision balance with resolution of 1 nN and 1-D fine positioning stage. Brief modeling of the cantilever is presented and then, the calibration results are shown. Tests revealed a linear relationship between the probing force and sensor output (resistance change), but the force vs. deflection is not as linear as the force vs. sensor output curve. The force constant of the cantilever was measured to 0.26 N/m with a standard deviation of 0.01 N/m. It shows that there is big difference between measured and nominal spring constant of 1 N/m provided by the manufacturer’s specifications.  相似文献   

8.
Phase noise is an important parameter to characterise the frequency stability of oscillators and synthesised signal generators. Accurate measurement of phase noise is required for various applications in radar, communication and navigation systems. A single-channel phase-detector based phase noise measurement system is described. The system’s measurement errors and uncertainties have been analysed in details. The expanded uncertainty is about 2.7 dB for calibrating phase noise of a signal generator at 0.001–1.6 GHz for frequency offsets from 1 Hz to 100 kHz. The uncertainty budget for measuring a signal generator’s phase noise at 640 MHz is also presented.  相似文献   

9.
A 50 N dead-weight type force standard machine (DWM) was developed by the National Metrology Institute of Japan to expand the lower end of calibration force from 10 N to 1 N. The weights of the DWM consisted of a loading frame and a linkage-weight stack. The loading frame applied a gravitational force of 1 N to a force transducer under calibration. The calibration and measurement capability of the 50 N DWM was verified to be 2 × 10−5 relative using a tuning-fork type force transducer in accordance with ISO 376. The equivalence between the 50 N and 500 N DWMs was confirmed by performing an intralaboratory comparison using the tuning-fork type force transducer. Moreover, the competence of the transducer for the evaluation of DWMs was demonstrated.  相似文献   

10.
A modified carbon paste electrode for haloperidol drug based on haloperidol-phosphomolybdate (HP-PM) as an ion-exchanger dissolved in plasticizer DBP and its potentiometric characteristics were discussed. The electrode exhibited a good Nernstian slope of 56.9 ± 0.3 mV/decade with a linear concentration range from 3.2 × 10−6 to 1.0 × 10−2 M for the haloperidol ion. The limit of detection (LOD) was 1.5 × 10−6 M. It had response time of 5–8 seconds (s), useable in pH range of 6.2–8.6 and temperature of 20–60 °C. The electrode shows clear discrimination of haloperidol drug from several inorganic ions, sugars and some common drug excipients. The sensor was applied for determination of haloperidol drug in urine and in pharmaceutical formulations using potentiometric determination, standard addition and the calibration curve methods. The results are satisfactory with excellent percentage recovery comparable or better than those obtained by other routine methods.  相似文献   

11.
Measurement uncertainty is an important parameter to express measurement results including means and reliability. The uncertainty analysis of the biomedical measurement system needs to be established. A perspiration measurement system composed of several sensors was developed. We aim to estimate the measurement uncertainty of this system with several uncertainty sources, including airflow rate, air density, and inlet and outlet absolute humidity. Measurement uncertainty was evaluated and compared by the Guide to the expression of the uncertainty in measurement (GUM) method and Monte Carlo simulation. The standard uncertainty for the perspiration measurement system was 6.81 × 10−6 kg/s and the uncertainty percentage <10%. The major source of the uncertainty was airflow rate, and inlet and outlet absolute humidity. The Monte Carlo simulation could be executed easily with available spreadsheet software programs of the Microsoft Excel. GUM and Monte Carlo simulation did not differ in measurement uncertainty with precision to two decimal places. However, the sensitivity coefficient derived by GUM provided useful information to improve measurement performance, which was not evaluated with the Monte Carlo simulation method.  相似文献   

12.
The paper discusses the development of the ring shaped force transducers for measurement of force in lower capacity to meet the industrial requirements with the increasing technological developments. A 50 N ring shaped force transducer for tension mode has been developed by studying the analytical and computational methods. The force transducer developed has been metrologically studied according to the calibration procedure based on the standard ISO 376 and uncertainty of measurement of the force transducer is found to be±0.10% (k=2), while taking into account the relative uncertainty contribution due to necessary factors like repeatability, reproducibility, zero offset, interpolation, resolution and reversibility. The force transducer developed may further be studied for improvement of metrological performance and may suitably be developed for other lower capacities like 10 N, 20 N etc. The force transducer developed offers very economical alternative of complex shaped force transducers with simple design and manufacturing features. The force transducer developed may be proved very helpful in providing traceability to the user industries and calibration laboratories in the lower range of force measurement and serve as force transfer standard.  相似文献   

13.
Lubrication conditions and blank holder force (BHF) are two key processing parameters in deep drawing. This is more obvious in micro forming because of the miniaturization of the specimen size. Micro conical–cylindrical cups with internal conical bottom diameter of only 0.4 mm were well formed. The influences of lubrication conditions and BHF on micro deep drawing of micro conical–cylindrical cups were investigated using a micro blanking–deep drawing compound mold. Pure copper C1100 with a thickness of 50 μm, which was annealed at 450 °C for 2 h in vacuum condition, was chosen as the specimen material. The experiments were conducted on a universal testing machine with a forming velocity of 0.05 mm/s under 4 kinds of lubrication conditions and BHF. The experimental results showed that a micro conical–cylindrical cup with internal conical bottom diameter of only 0.4 mm was well formed, and the limiting drawing ratio (LDR) reached 2.1. The polyethylene (PE) film, which decreased the drawing force and increased the drawing ratio (DR), was superior to castor oil, petroleum jelly and dry friction, and can be chosen as a proper lubricant for micro deep drawing. The rim of the micro cup seriously wrinkled when BHF was less than 4.2 N. The bottom of the micro cup cracked when the BHF was larger than 5.6 N.  相似文献   

14.
The paper describes the design, measurement results and uncertainty analyses of the hydraulic driven piston-prover system which has been in operation at VSL since 2008. The 12-meter long, 0.6 m bore piston-prover is used for the realization of Reference Values for Gas-Volume at pressures between 1 and 65 bar(a) at several gases. The principle is based on the displacement of a piston acting as a Gas–Oil separator. The standard has a flow-rate range from 5 to 230 m3/h. The system is designed to calibrate reference meters. The Calibration and Measurement Capability (CMC) of the system is proven to be smaller than 0.1% (k=2). The paper also explains the coherence between the Gas–Oil piston-prover and other traceability generators and ‘flow rate bootstrapper systems’.  相似文献   

15.
《Wear》2007,262(1-2):93-103
A pin on disc machine was used to investigate the tribological behavior of a diffusion bonded sintered steel, with and without surface treatments of steam oxidation and manganese phosphating, over a wide range of speed (0.2–4 m/s) and applied load (4–500 N) in conditions of dry sliding and starved lubrication by oil impregnation of the porous structure of the materials. Besides the calculated wear rates, the wear mechanisms were determined by examination of the components of the rubbing system (sintered pin, disc and generated debris). A transition from a mild to a severe wear regime was identified, denoted by sharp changes of the wear rate. A transient wear regime, interposed between the mild and severe wear regimes, was detected. The rubbing surface quality degradation was in terms of material displacement around the pin circumference due to a delamination wear mechanism. Such regime was detected for the base sintered steel in dry sliding at 1 m/s for the load range 60–80 N and for both surface treatments in oil impregnated sliding at 0.5 m/s for the load range 200–300 N. Oil impregnation of the base sintered steel expanded the mild wear regime towards higher loads throughout the whole sliding speed range compared to dry sliding. For the lower speeds of 0.2 and 0.5 m/s, manganese phosphated samples in dry sliding exhibited higher transition loads compared to the base sintered steel. The lower oil impregnability of the surface treated samples, due to the sealing of porosity by steam oxidation, led to slightly lower transition loads in oil impregnated sliding, compared to the base sintered steel.  相似文献   

16.
Bilateral comparisons of the calibration of low nominal capacity torque measuring devices (TMDs) were conducted between NMIJ and PTB for the first time. A 10 N m deadweight torque standard machine (TSM) newly developed at NMIJ was compared with PTB’s two TSMs with nominal capacities of 1 N m and 1 kN m, in the range from 0.1 N m to 10 N m. The transfer measurement devices used had nominal capacities of 1 N m and 10 N m. The comparisons were made using two calibration procedures: one based on the CCM.T-K2 Key Comparison procedure and the other according to the daily calibration procedure adopted at each institute. As a result, the torque realized by the TSM at NMIJ was shown to be equivalent to that realized by the two TSMs at PTB. In addition, it was confirmed that the daily calibration procedures of both institutes yielded consistent results in the calibration of low nominal capacity TMDs.  相似文献   

17.
A new approach is proposed to improve a graphical approach with considering intensity coupling loss coefficients in the analytical derivation of the optical transfer functions for a symmetric double stage vertically coupled microring resonator. An optimum transmission coupling condition is determined with considering terms of couplers intensity loss which leads to low insertion loss of 1.2 dB, finesse of 1525, the out of band rejection ratio of 61.8 dB. The resonating system is used as an optical force sensing system to make the benefit of the accuracy of measurements in micro and nano scales. The sensitivity of proposed force sensor in terms of wavelength-shift is 33 nm/nN and the limit of detection is 1.6 × 10−2 nN. The proposed sensing system has the advantages of self-calibration and the low power consumption due to the low intensity.  相似文献   

18.
《Ultramicroscopy》2011,111(1):11-19
We present a new method to improve the accuracy of force application and hardness measurements in hard surfaces by using low-force (<50 μN) nanoindentation technique with a cube-corner diamond tip mounted on an atomic force microscopy (AFM) sapphire cantilever. A force calibration procedure based on the force-matching method, which explicitly includes the tip geometry and the tip-substrate deformation during calibration, is proposed. A computer algorithm to automate this calibration procedure is also made available. The proposed methodology is verified experimentally by conducting AFM nanoindentations on fused quartz, Si(1 0 0) and a 100-nm-thick film of gold deposited on Si(1 0 0). Comparison of experimental results with finite element simulations and literature data yields excellent agreement. In particular, hardness measurements using AFM nanoindentation in fused quartz show a systematic error less than 2% when applying the force-matching method, as opposed to 37% with the standard protocol. Furthermore, the residual impressions left in the different substrates are examined in detail using non-contact AFM imaging with the same diamond probe. The uncertainty of method to measure the projected area of contact at maximum force due to elastic recovery effects is also discussed.  相似文献   

19.
A method of enhancing the electrical conductivity of 3,4-ethylenedioxythiophene:poly styrene sulfonate (PEDOT:PSS) by combining solvent treatment (adding high polar solvent: 5 wt% ethylene glycol) and adding a small amount of silver (Ag) nanoparticles in a solution was investigated. The main purpose of this was to apply a PEDOT:PSS conductive layer to micro-thermal devices driven by electricity and, for this, to reduce the layer thickness (for low stiffness) while maintaining necessary high electrical conductivity. Layers with thicknesses of less than about 10 μm were examined for electrical conductivity and temperature when electricity was applied. The solvent treated PEDOT:PSS had suitable electrical resistance to generate appropriate temperature properties. The added Ag nanoparticles reduced the electrical resistance by 30–70% over the measured thickness range. The electric conductivity applied with this method was 200–260 Ω−1 cm−1 for thicknesses of 1–2 μm (conductive area: 12 mm × 10 mm) and the generated temperature increase was 20–50 °C at applied voltages of 3–5 V. These characteristics are considered to be suitable to use the conductive layer as a heating element. In addition, the method we used scarcely degraded the transparency of the layer. Measurements of the conductive area in a layer with conductive atomic force microscope (AFM) indicated that the added Ag nanoparticles contributed to increasing the conductive areas and distributing them more uniformly.  相似文献   

20.
《Wear》2006,260(4-5):401-411
In case of fabric reinforced composites of specialty polymers influence of orientation of fabric and its volume fraction on tribo-behaviour is sparingly studied. In our earlier work, we have reported on the influence of amount of Aramid fabric (AF) in polyethersulfone (PES) on abrasive wear performance. However, orientation effect of fabric with respect to abrading plane was not investigated. In this work three orientations of composites of PES containing Aramid (Kevlar 29) fabric with three concentrations 64, 72 and 83 wt.% were selected to study the influence on abrasive wear performance. Composites developed by compression molding technique were characterized for their mechanical and physical properties. The abrasive wear performance of the composites was evaluated by abrading 10 mm × 10 mm × 10 mm sample against silicon carbide (SiC) paper under various loads and two grades of abrasive papers. The fabric reinforcement enhanced the abrasive wear resistance of PES significantly (approximately 1.35–9.46 times depending on the operating conditions). It was observed that 83% fabric composite showed the highest resistance to abrasive wear and impact along with the best tensile strength and elongation properties. Its flexural strength and ILSS values, however, were the lowest. Sixty-four percent fabric composite, on the other hand, showed an exactly reverse trend among the three composites. Among the three orientations, fibres in normal and parallel (N–P) and normal and anti-parallel (N–AP) direction with respect to sliding plane proved to impart maximum wear resistance. N–P was best for light loads while N–AP was best for high loading conditions. Orientation parallel and anti-parallel (P–AP) was least beneficial in this respect. Moreover, the extent of improvement very much depended on the operating parameters such as grit size and load. Benefits endowed due to reinforcement were higher at less coarse grade paper. With increase in load, however, wear rate of composites with N–P orientation increased and for other two orientations it decreased. Thus, for severe operating conditions, N–AP orientation proved to be most beneficial. SEM studies proved supporting for understanding the influence of orientation on wear performance.  相似文献   