1.
This paper presents a study of local thermal sensation (LTS) and comfort in a field environmental chamber (FEC) served by displacement ventilation (DV) system. The FEC, 11.12 m (L)×7.53 m (W)×2.60 m (H), simulates a typical office layout. A total of 60 tropically acclimatized subjects, 30 male and 30 female, were engaged in sedentary office work for 3 h. Subjects were exposed to three vertical air temperature gradients, nominally 1, 3 and 5 K/m, between 0.1 and 1.1 m heights and three room air temperatures of 20, 23 and 26 °C at 0.6 m height. The objective of this study is to investigate the mutual effect of local and overall thermal sensation (OTS) and comfort in DV environment. The results show that in a space served by DV system, at OTS close to neutral, local thermal discomfort decreased with the increase of room air temperature. The OTS of occupants was mainly affected by LTS at the arm, calf, foot, back and hand. Local thermal discomfort was affected by both LTS and OTS. At overall cold thermal sensation, all body segments prefer slightly warm sensation. At overall slightly warm thermal sensation, all body segments prefer slightly cool sensation. 相似文献
2.
The effect of vertical air temperature gradient on overall and local thermal comfort at different overall thermal sensations and room air temperatures (at 0.6 m height) was investigated in a room served by displacement ventilation system. Sixty tropically acclimatized subjects performed sedentary office work for a period of 3 h during each session of the experiment. Nominal vertical air temperature gradients between 0.1 and 1.1 m heights were 1, 3 and 5 K/m while nominal room air temperatures at 0.6 m height were 20, 23 and 26 °C. Air velocity in the space near the subjects was kept at below 0.2 m/s. Relative humidity at 0.6 m height was maintained at 50%. It was found that temperature gradient had different influences on thermal comfort at different overall thermal sensations. At overall thermal sensation close to neutral, only when room air temperature was substantially low, such as 20 °C, percentage dissatisfied of overall body increased with the increase of temperature gradient. At overall cold and slightly warm sensations, percentage dissatisfied of overall body was non-significantly affected by temperature gradient. Overall thermal sensation had significant impact on overall thermal comfort. Local thermal comfort of body segment was affected by both overall and local thermal sensations. 相似文献
3.
K.W.D. Cheong W.J. Yu R. Kosonen K.W. Tham S.C. Sekhar 《Building and Environment》2006,41(12):1661-1670
This paper presents a thermal comfort study using a thermal manikin in a field environment chamber served by the Displacement Ventilation (DV) system. The manikin has a female body with 26 individually heated and controlled body segments. The manikin together with subjects was exposed to 3 levels of vertical air temperature gradients, nominally 1, 3 & 5 K/m, between 0.1 and 1.1 m heights at 3 room air temperatures of 20, 23 and 26 °C at 0.6 m height. Relative humidity at 0.6 m height and air velocity near the manikin and the subjects were maintained at 50% and less than 0.2 m/s, respectively. The aims of this study are to assess thermally non-uniform environment served by DV system using the manikin and correlate the subjective responses with measurements from the manikin. The main findings indicate that room air temperature had greater influence on overall and local thermal sensations and comfort than temperature gradient. Local thermal discomfort decreased with increase of room air temperature at overall thermally neutral state. The local discomfort was affected by overall thermal sensation and was lower at overall thermally neutral state than at overall cold and cool sensations. 相似文献
4.
The purpose of this paper is to investigate, using a validated computational fluid dynamics simulation, the effect of the position of doors on performance of the displacement ventilation system. The results are reported in terms of thermal comfort and indoor air quality. The study focuses on a typical Hong Kong office under local thermal and boundary conditions. It was found that the presence of large heat sources such as from a window can cause the lateral movement of airflow, disrupting the convection effect which the displacement ventilation system relies on. Doors can create this situation when they are opened by changing the thermal boundary conditions of indoor spaces. The designer should be made aware of this possibility and make appropriate design decisions to accommodate for this fact. 相似文献
5.
A field survey of occupants' response to the indoor environment in 10 office buildings with displacement ventilation was performed. The response of 227 occupants was analyzed. About 24% of the occupants in the survey complained that they were daily bothered by draught, mainly at the lower leg. Vertical air temperature difference measured between head and feet levels was less than 3 degrees C at all workplaces visited. Combined local discomfort because of draught and vertical temperature difference does not seem to be a serious problem in rooms with displacement ventilation. Almost one half (49%) of the occupants reported that they were daily bothered by an uncomfortable room temperature. Forty-eight per cent of the occupants were not satisfied with the air quality. PRACTICAL IMPLICATIONS: The PMV and the Draught Rating indices as well as the specifications for local discomfort because of the separate impact of draught and vertical temperature difference, as defined in the present standards, are relevant for the design of a thermal environment in rooms with displacement ventilation and for its assessment in practice. Increasing the supply air temperature in order to counteract draught discomfort is a measure that should be considered carefully; even if the desired stratification of pollution in the occupied zone is preserved, an increase of the inhaled air temperature may have a negative effect on perceived air quality. 相似文献
6.
The importance of the intake positioning height above the floor level on the performance of “ductless” personalized ventilation (“ductless” PV) in conjunction with displacement ventilation (DV) was examined with regard to the quality of inhaled air and of the thermal comfort provided. A typical office room with two workstations positioned one behind the other was arranged in a full-scale room. Each workstation consisted of a table with an installed “ductless” PV system, PC, desk lamp and seated breathing thermal manikin. The “ductless” PV system sucked the clean and cool displacement air supplied over the floor at four different heights, i.e. 2, 5, 10 and 20 cm and transported it direct to the breathing level. Moreover, two displacement airflow rates were used with a supply temperature adjusted in order to maintain an exhaust air temperature of 26 °C. Two pollution sources, namely air exhaled by one of the manikins and passive pollution on the table in front of the same manikin were simulated by constant dosing of tracer gases. The results show that the positioning of a “ductless” PV intake height up to 0.2 m above the floor will not significantly influence the quality of inhaled air and thermal comfort. 相似文献
7.
Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged. 相似文献
8.
Xiaoli Hao Guoqiang Zhang Youming Chen Shenghua Zou Demetrios. J. Moschandreas 《Building and Environment》2007
Different types of heating, ventilation, and air-conditioning (HVAC) systems consume different amounts of energy yet they deliver similar levels of acceptable indoor air quality (IAQ) and thermal comfort. It is desirable to provide buildings with an optimal HVAC system to create the best IAQ and thermal comfort with minimum energy consumption. In this paper, a combined system of chilled ceiling, displacement ventilation and desiccant dehumidification is designed and applied for space conditioning in a hot and humid climate. IAQ, thermal comfort, and energy saving potential of the combined system are estimated using a mathematical model of the system described in this paper. To confirm the feasibility of the combined system in a hot and humid climate, like China, and to evaluate the system performance, the mathematical model simulates an office building in Beijing and estimates IAQ, thermal comfort and energy consumption. We conclude that in comparison with a conventional all-air system the combined system saves 8.2% of total primary energy consumption in addition to achieving better IAQ and thermal comfort. Chilled ceiling, displacement ventilation and desiccant dehumidification respond consistently to cooling source demand and complement each other on indoor comfort and air quality. It is feasible to combine the three technologies for space conditioning of office building in a hot and humid climate. 相似文献
9.
介绍了一个芬兰地下空间病态建筑综合症调查实例,分析了地下空间的热环境特点和影响其空气品质的主要因素,提出了改善地下空间空气品质的方法。 相似文献
10.
Ventilation in Scandinavian buildings is commonly performed by means of a constant flow ventilation fan. By using a regulated fan, it is possible to make a seasonal adjustment of outdoor ventilation flow. Energy saving can be achieved by reducing the mechanical ventilation flow during the heating season, when natural ventilation driven by temperature differences between outdoor and indoor is relatively high. This ventilation principle has been called 'seasonally adapted ventilation (SAV)'. The aim was to study if a 25-30% reduction of outdoor ventilation flow during heating season influenced sick building syndrome (SBS) and the perception of the indoor environment. This was done in a 1-year cross-over intervention study in 44 subjects in a multi-family building. During the first heating season (November to April), one part of the building (A) got a reduced flow during the heating season [0.4-0.5 air exchanges per hour (ACH)] while the other part (B) had constant flow (0.5-0.8 ACH). The next heating season, part A got constant flow, while part B got reduced ventilation flow. Reduced ventilation increased the relative air humidity by 1-3% in the living room (mean 30-37% RH), 1-5% in the bathroom (mean 48-58% RH) during heating season. The room temperature increased 0.1-0.3 degrees C (mean 20.7-21.6 degrees C), mean carbon dioxide (CO2) concentration in the bedroom increased from 920 to 980 p.p.m. at reduced flow. The indoor air quality was perceived as poorer at reduced outdoor airflow, both in the bedroom and in the apartment as a whole. There was a significant increase of stuffy odor (P = 0.05) at reduced outdoor airflow and the indoor air quality was perceived as poorer, both in the bedroom (P = 0.03) and in the apartment as a whole (P = 0.04). No significant influence on SBS symptoms or specific perceptions such as odors, draught, temperature, air dryness or stuffy air could be detected. In conclusion, reducing the ventilation flow in dwellings to a level below the current Swedish ventilation standard (0.5 ACH) may cause a perception of impaired air quality. Technical measurements could only demonstrate a minor increase of indoor temperature, relative air humidity, and bedroom CO2 concentration. This illustrates that it is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. PRACTICAL IMPLICATIONS: It is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. Reduction of outdoor airflow in dwellings below the current ventilation standard of 0.5 ACH may lead to a perception of impaired air quality, despite only a minor increase of bedroom CO2-concentration. 相似文献
11.
There are few incidence studies on sick building syndrome (SBS). We studied two-year change of SBS in Chinese pupils in relation to parental asthma/allergy (heredity), own atopy, classroom temperature, relative humidity (RH), absolute humidity (AH), crowdedness, CO?, NO?, and SO?. A total of 1993 participated at baseline, and 1143 stayed in the same classrooms after two years. The prevalence of mucosal and general symptoms was 33% and 28% at baseline and increased during follow-up (P < 0.001). Twenty-seven percent reported at least one symptom improved when away from school. Heredity and own atopy were predictors of SBS at baseline and incidence of SBS. At baseline, SO? was associated with general symptoms (OR=1.10 per 100 μg/m3), mucosal symptoms (OR=1.12 per 100 μg/m3), and skin symptoms (OR=1.16 per 100 μg/m3). NO? was associated with mucosal symptoms (OR=1.13 per 10 μg/m3), and symptoms improved when away from school (OR=1.13 per 10 μg/m3). Temperature, RH, AH, and CO? were negatively associated with prevalence of SBS. Incidence or remission of SBS was not related to any exposure, except a negative association between SO? and new skin symptoms. In conclusion, heredity and atopy are related to incidence and prevalence of SBS, but the role of the measured exposures for SBS is more unclear. PRACTICAL IMPLICATIONS: We found high levels of CO? indicating inadequate ventilation and high levels of SO? and NO?, both indoors and outdoors. All schools had natural ventilation, only. Relying on window opening as a tool for ventilation in China is difficult because increased ventilation will decrease the level of CO? but increase the level of NO? and SO? indoors. Prevalence studies of sick building syndrome (SBS) might not be conclusive for causal relationships, and more longitudinal studies on SBS are needed both in China and other parts of the world. The concept of mechanical ventilation and air filtration should be introduced in the schools, and when planning new schools, locations close to heavily trafficked roads should be avoided. 相似文献
12.
Schools may be poorly ventilated and may contain furry pet allergens, particles and microorganisms. We studied health effects when changing from mixing ceiling ventilation to two types of displacement ventilation, front ventilation system (FVS) and floor master system (FMS). The study included pupils in three elementary school classes (N = 61), all with floor heating. One class received blinded interventions; the two others were unchanged (controls). Ventilation flow and supply air temperature was kept constant. The medical investigation included tear film stability (BUT), nasal patency and a questionnaire containing rating scales. When changing from mixing ventilation to FVS, the pupils (N = 26) perceived better air quality (P = 0.006) and less dyspnoea (P = 0.007) as compared to controls (N = 35), and BUT was improved (P = 0.03). At desk level, mean CO(2) was reduced from 867 to 655 ppm. Formaldehyde and viable bacteria were numerically lower, while total bacteria and molds were higher with displacement ventilation. There was no difference in symptoms or signs when changing from FVS to FMS. Cat (Der p1), dog (Can f1) and horse allergen (Equ cx) were common in air at all conditions. In conclusion, displacement ventilation may have certain positive health effects among pupils, as compared to conventional mixing ceiling systems. PRACTICAL IMPLICATIONS: Displacement ventilation may be a suitable ventilation principle for achieving good indoor environment in classrooms. The type of supply air diffuser does not seem to be of major importance. The combination of floor heating and displacement ventilation can be a useful way of avoiding the previously described problem of thermal discomfort. 相似文献
13.
Zhang X Zhao Z Nordquist T Larsson L Sebastian A Norback D 《The Science of the total environment》2011,409(24):5253-5259
There are few longitudinal studies on sick building syndrome (SBS), which include ocular, nasal, throat, and dermal symptoms, headache, and fatigue. We studied the associations between selected microbial components, fungal DNA, furry pet allergens, and incidence and remission of SBS symptoms in schools in Taiyuan, China. The study was based on a two-year prospective analysis in pupils (N = 1143) in a random sample of schools in China. Settled dust in the classrooms was collected by vacuum cleaning and analyzed for lipopolysaccharide (LPS), muramic acid (MuA), and ergosterol (Erg). Airborne dust was collected in Petri dishes and analyzed for cat and dog allergens and fungal DNA. The relationship between the concentration of allergens and microbial compounds and new onset of SBS was analyzed by multi-level logistic regression. The prevalence of mucosal and general symptoms was 33% and 28%, respectively, at baseline, and increased during follow-up. At baseline, 27% reported at least one symptom that improved when away from school (school-related symptoms). New onset of mucosal symptoms was negatively associated with concentration of MuA, total LPS, and shorter lengths of 3-hydroxy fatty acids from LPS, C14, C16, and C18. Onset of general symptoms was negatively associated with C18 LPS. Onset of school-related symptoms was negatively associated with C16 LPS, but positively associated with total fungal DNA. In general, bacterial compounds (LPS and MuA) seem to protect against the development of mucosal and general symptoms, but fungal exposure measured as fungal DNA could increase the incidence of school-related symptoms. 相似文献
14.
Tomoko Takigawa Bing-Ling Wang Da-Hong Wang Reiko Kishi 《The Science of the total environment》2009,407(19):5223-5228
This study was performed to explore possible environmental risk factors, including indoor chemicals, mold, and dust mite allergens, which could cause sick building syndrome (SBS)-type symptoms in new houses. The study was conducted in 2004 and 2005 and the final study population consisted of 86 men and 84 women residing in Okayama, Japan. The indoor concentrations of indoor aldehydes, volatile organic compounds, airborne fungi, and dust mite allergens in their living rooms were measured and the longitudinal changes in two consecutive years were calculated. A standardized questionnaire was used concomitantly to gather information on frequency of SBS-type symptoms and lifestyle habits. About 10% of the subjects suffered from SBS in the both years. Crude analyses indicated tendencies for aldehyde levels to increase frequently and markedly in the newly diseased and ongoing SBS groups. Among the chemical factors and molds examined, increases in benzene and in Aspergillus contributed to the occurrence of SBS in the logistic regression model. Indoor chemicals were the main contributors to subjective symptoms associated with SBS. A preventive strategy designed to lower exposure to indoor chemicals may be able to counter the occurrence of SBS. 相似文献
15.
The aim was to develop a multiple logistic regression model to identify multi-family houses with an increase of sick building syndrome (SBS). In Stockholm, 609 multi-family buildings with 14,235 dwellings were selected by stratified random sampling. The response rate was 77%. Multiple logistic regression analysis was applied, adjusting for ownership of the building, building age and size, age, gender, and atopy. Females, subjects with allergy, those above 65 yr, and those in new buildings reported significantly more SBS. Subjects owning their own building reported less SBS, but the relationship between ownership and building age was strong. A regression model, including factors with a high explanatory value was developed. According to the model, 5% of all buildings built before 1961, 13% of those built 1976-1984, and 15% of those built 1985-1990 would have significantly more SBS than expected. In conclusion, SBS is related to personal factors, building age, and ownership of the building. To identify multi-family buildings with more SBS than expected, it is necessary to adjust for ownership and population characteristics. 相似文献
16.
Zhang Lin T.T. ChowC.F. Tsang K.F. FongL.S. Chan W.S. ShumLuther Tsai 《Building and Environment》2009
This paper presents a case to investigate the effect of partitions in an office on the performance of under floor air supply ventilation system via computational fluid dynamics. The assessment is in terms of thermal comfort and indoor air quality with the use of a validated computer model. The results indicate that the partitions may significantly affect airflow and performance of a under floor air supply ventilation system. In particular, the presence of a gap above the partition wall is able to improve air distribution owing to less air re-circulation in the upper zone. Its effect on thermal comfort and indoor air quality indicators are evaluated. 相似文献
17.
18.
Liddament MW 《Indoor air》2000,10(3):193-199
Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these aspects with particular reference to recent research and developments. Key aspects are concerned with identifying the role of ventilation and reviewing this role in the context of the other measures that must be taken to secure a healthy indoor environment. References are particularly made to the development of standards and recent related research. Although good progress is being made, areas that still need to be addressed include maintaining good outdoor air quality and preventing contaminated outdoor air from entering buildings. The outcome of recent research must also be disseminated in practical ways to policy makers, building occupiers and practitioners. Good indoor climate can be achieved, not so much by introducing expensive concepts, but by developing a rationale approach to identifying needs and applying the necessary tools to deal with each need. 相似文献
19.