PURPOSE: To assess possible changes in quality control (QC) practices at mammography sites in the United States. MATERIALS AND METHODS: Mammography site surveys were conducted in 1990, 1992, and 1995 through the Colorado Mammography Advocacy Project (CMAP). Data from mammography sites applying for American College of Radiology (ACR) accreditation were collected between August 1987 and August 1993 through the ACR Mammography Accreditation Program. Data from both of these surveys were analyzed to assess temporal changes in mammography QC practices in the United States between 1987 and 1995. RESULTS: CMAP results indicated statistically significant improvement in medical physicist QC practices between 1990 and 1992 and in technologist QC practices between 1990 and 1995. Improvements in radiologic technologist QC practices coincided with increases in radiologic technologist continuing education in mammography. ACR results indicated statistically significant improvement in technologist QC practices between 1988 and 1992. CONCLUSION: There have been substantial improvements in QC practices at mammography sites in the United States during the past decade.  相似文献   

2.
Provides information on funding sources for research activities. Grant and contract programs sponsored by various federal agencies are described, including those of the National Science Foundation, various branches of Health, Education and Welfare (the National Institute of Mental Health, the National Institute of Child Health and Human Development, the Office of Education, and the Social and Rehabilitation Service), and the Departments of Labor, Transportation, Defense, State, Justice, Housing and Urban Development, and the National Aeronautics and Space Program. Programs of 31 private foundations are also listed, including the foundation name and address, and the purposes and activities of the respective support programs. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

3.
Some inherent limitations to further technical improvement in film-screen mammography exist. Many of these limitations can be overcome effectively with digital mammography, in which image acquisition, display, and storage are performed independently, thus allowing the optimization of each. Presented is a brief background of digital and analog imaging with emphasis on the features and drawbacks of digital mammography systems. Image storage, processing, and display, computer-aided detection and diagnosis, as well as telemammography are also discussed.  相似文献   

4.
DICOM (Digital Imaging and Communications in Medicine) Working Group XI, formerly called ACR/NEMA (American College of Radiology/National Electrical Manufacturers' Association) Working Group XI, is currently developing a display function standard. The main objective of the standard is to define mathematically a display function for all image presentation systems. As a secondary objective, the standard aims at providing similarity in gray-scale perception for a given image between display systems of different luminance and at facilitating efficient utilization of the available digital input levels of a display system. The design of the display function incorporates the concept of perceptual linearization. The proposed standard applies to monochrome image presentation devices such as cathode ray tube monitor-display controller systems and digital laser image printers. The standard does not eliminate the use of application-specific display functions but rather ensures their effectiveness. Neither does the standard guarantee equal information transfer between image presentation devices with different physical properties; it does, however, from the basis for applying image processing to compensate for such differences.  相似文献   

5.
OBJECTIVE: To investigate practical solutions that can integrate cryptographic techniques and picture archiving and communication systems (PACS) to improve the security of medical images. DESIGN: The PACS at the University of California San Francisco Medical Center consolidate images and associated data from various scanners into a centralized data archive and transmit them to remote display stations for review and consultation purposes. The purpose of this study is to investigate the model of a digital trust center that integrates cryptographic algorithms and protocols seamlessly into such a digital radiology environment to improve the security of medical images. MEASUREMENTS: The timing performance of encryption, decryption, and transmission of the cryptographic protocols over 81 volumetric PACS datasets has been measured. Lossless data compression is also applied before the encryption. The transmission performance is measured against three types of networks of different bandwidths: narrow-band Integrated Services Digital Network, Ethernet, and OC-3c Asynchronous Transfer Mode. RESULTS: The proposed digital trust center provides a cryptosystem solution to protect the confidentiality and to determine the authenticity of digital images in hospitals. The results of this study indicate that diagnostic images such as x-rays and magnetic resonance images could be routinely encrypted in PACS. However, applying encryption in teleradiology and PACS is a tradeoff between communications performance and security measures. CONCLUSION: Many people are uncertain about how to integrate cryptographic algorithms coherently into existing operations of the clinical enterprise. This paper describes a centralized cryptosystem architecture to ensure image data authenticity in a digital radiology department. The system performance has been evaluated in a hospital-integrated PACS environment.  相似文献   

6.
A National Aeronautics and Space Administration (NASA) research and technology program called the large deployable antenna (LDA) program was initiated in early 1989 by NASA Langley Research Center to investigate and demonstrate the availability of critical technologies for passive microwave imagers. The NASA Office of Aeronautics, Exploration, and Technology (OAET) sponsored this research program to provide advanced sensor technologies for mission to planet Earth remote sensing applications. The goal of the OAET program is to provide the technology needed to enable and enhance the long‐term observations, documentation, and understanding of the Earth as a system. The LDA program involved university, industry, and NASA researchers and technologists with a range of skills and experience from electromagnetic theory to advanced materials and deployable structures. The study approach involved determining basic operational parameters and configurations for a geosynchronous wide‐scanning radiometer from which specific structural requirements were used as goals (rather than specifications) with which specific technologies could be evaluated. The study team performed a detailed technology review, evaluated the feasibility and technology readiness for a large dual‐reflector radiometer, and developed a system concept for a 25 m deployable radiometer. This paper describes the science objectives, reviews the current state of the art, presents electromagnetic configurations under consideration, and discusses the mechanical systems development effort.  相似文献   

7.
This study examines the suitability of working with a selection of images in a teleradiology consulting system in neurological or neurosurgical emergency situations. The teleradiology system was based on IBM-compatible personal computers, video digitization for data acquisition, and data transmission by Integrated System Digital Network. Forty normal and 60 abnormal emergency cranial computed tomograms were shown to a radiologist on call who presented all cases he regarded as pathologic to a neuroradiologic expert by teleradiology. To reduce transmission time, only a selection of images from the CT study was presented (up to four images per case). For each case the on-call radiologist's diagnosis (D(on-call)), the expert's diagnosis on the teleradiology screen (D(monitor)), and the expert's diagnosis on the original film (D(original)) was documented, together with an estimation of the agreement between those diagnoses. There was clinically relevant disagreement between the on-call radiologist's diagnosis and the neuroradiologist's diagnosis based on the image selection on the teleradiology monitor in 23% of cases. A clinically important discrepancy between the neuroradiologist's diagnosis based on the image selection and his diagnosis using the original films was found in 30% of cases. This was due to the presence of clinically relevant information on images not transferred by the on-call radiologist. Image quality of the transferred images was sufficient in all cases. Drastic selection of images from a complete CT study leads to a high rate of incorrect diagnoses and is not appropriate to reduce transmission time in teleradiology.  相似文献   

8.
A key advantage in the conversion from film-based to digital radiology is the possibility of a long-term on line electronic archival of patient studies. The popular approach based on optical disk jukeboxes for the long-term archive and magnetic disk storage for data caching is not economically attractive because of the cost of both the jukebox and the medium. Strategies for extending the archival system design with a tape jukebox have been studied. The proposed strategy calls for the use of high-ratio lossy compression together with low-cost tape storage to make long-term on line archiving more affordable. An intelligent prefetching algorithm based on hospital information system and radiologic information system triggers, which in turn are augmented by manual case preparation, can effectively overcome the longer latency of ad hoc retrievals. This longer latency is caused by both system-level bottlenecks and the sequential access constraint of the tape drive. Strategies for image clustering and tape allocation by patient classification also enhance retrieval efficiency. This archival design using image compression, prefetching, and clustering could be implemented in many of the existing teleradiology and picture archiving and communication systems.  相似文献   

9.
Economical applications of teleradiology and telemedicine are limited to the existing telephone network infrastructure, which greatly limits the speed of digital information transfer. Telephone lines are inherently slow, requiring image transmission times to be unacceptably long for large, complex, or numerous images. JPEG (Joint Photographic Experts Group) image transmission has been shown to compress images to 10% of the original file size without a noticeable change in the quality of the image. This study was carried out to assess the quality of medical diagnostic images after JPEG compression and decompression. X-rays, computed tomography scans, and ultrasound samples were compressed and decompressed using JPEG. The compressed JPEG images were indistinguishable from the original images. The JPEG images were approximately 10% of the original file size. This would reduce image transmission times by 90% (eg, an unacceptable time of 50 minutes would be reduced to an acceptable time of 5 minutes). JPEG can be used to optimize teleradiology and telemedicine.  相似文献   

10.
Reviews technological progress that has been made by the National Aeronautics and Space Administration (NASA) in the field of biotelemetry over the past 5 yrs. Emphasis is placed on those developments that have direct applications for human or animal use on earth. Examples of biobelt personal telemetry systems, swallowable telemetry capsules, cardiovascular multichannel implantable telemetry units, and long-range radiotelemetry of biologic data are presented. (19 ref) (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

11.
The dramatic advances in radiology have increased the number and type of machines and of daily performed exams. Consequently, workload and management organization problems have also markedly increased. Automated, computerized scheduling of radiologic exams is certainly a step forward in a modern rational management of a Diagnostic Imaging service: the relationship with the patient is improved with the optimization of care delivered and of the radiologist's work, who with the new technology is able to rapidly consult the previous exams as well as the list of exams to be performed. The advances in health care information technology imply communications at a distance. From each ward of the hospital, requests for radiologic exams can be automatically scheduled or kept on a dynamic waiting list for automated input in future work shifts. Via the same system, reports (and also radiologic images) can by rapidly transmitted to the wards. At the "Università Cattolica del S. Cuore" from several years, an integrated information system has been implemented for management of patient data, exams and care delivered. Radiology represents one of major departmental systems of the network for the number of machines installed and the amount of information supplied. The system will be soon able to store images from all digital and nondigital machines, and visualize on dedicated workstations the images of ongoing exams or stored previous ones.  相似文献   

12.
The purpose of this investigation was to apply the recently developed CAMPI (computer analysis of mammography phantom images) method to a Fischer Mammotest Stereotactic Digital Biopsy machine. Another aim was to further elucidate the nature of the empirically introduced CAMPI measures. Images of an American College of Radiology (ACR) accreditation phantom centered on the largest two speck groups were obtained on this machine under a variety of x-ray conditions. An additional measure, alternative SNR (ASNR) is introduced which is complementary to the SNR measure. Analyses of the Mammotest images revealed that the mAs and kVp dependencies of the CAMPI measures could be understood from basic imaging physics principles. It is shown that: (1) the measures reflect the expected linearity of the digital detector and Poisson photon statistics; (2) under automatic exposure control (AEC) conditions the signal (SIG) measure is proportional to subject contrast; and (3) under AEC conditions the noise (NOI) measure is proportional to the square root of the average absorbed photon energy. Correspondence with basic imaging physics principles shows that the measures are significantly free of artifacts. Precision of the CAMPI measures exceeds that of human observers by orders of magnitude. CAMPI measures are expected to be more relevant to clinical mammography than Fourier metrics as the measurements are done on objects of arbitrary shape and size that were designed by the manufacturer to resemble various detection tasks in mammography. It is concluded that CAMPI can perform objective and highly precise evaluations of phantom image quality in mammography. It could be used as a sophisticated quality control tool, as a replacement for the current ACR/MQSA phantom evaluation program, and to evaluate the rapidly evolving digital mammography technology.  相似文献   

13.
The Canadian National Breast Screening Study (CNBSS) was the first study designed to determine the efficacy of screening for breast carcinoma in women 40-49 years old. Women were randomized to undergo either annual mammography and physical examination or usual care after an initial physical examination [1]. Women 50-59 years old were randomized to undergo either annual mammography and physical examination or annual physical examination only [2]. This study, published by epidemiologists on the efficacy of a radiologic examination, therefore, invites evaluation by radiologists.  相似文献   

14.
Imaging input technology is at its greatest rate of development ever, with CCD technology improving both in terms of image quality and image economy. The current diversity of imager modalities and application specializations allows for elegant matching of device capability to image subject photographic requirements. Both color and low-light imaging technologies continue to evolve, with ever-increasing resolution and dynamic range. The "order of magnitude" cost decreases that so aptly characterized the computer industry of the 1970s and 1980s is now upon the digital imager industry. Although analog cameras, based on video formats, still prevail, the direct digital camera will emerge as the preferred input device within a decade.  相似文献   

15.
PURPOSE: To determine trends in mammography in the United States. MATERIALS AND METHODS: A sample of mammographic facilities was selected for each year of the Nationwide Evaluation of X-ray Trends. The same protocol was followed for the 1985, 1988, and 1992 surveys. Data were collected with use of the same imaging phantom for all three surveys and also with a different phantom in the 1988 and 1992 surveys. RESULTS: Of the 356 facilities surveyed in 1992, 59% claimed to be in compliance with the Health Care Financing Administration (HCFA) mammography requirements, 42% were accredited by the American College of Radiology (ACR), and 23% did not hold credentials from either the HCFA or the ACR. Since 1985, there has been a 34% improvement in acceptable phantom image quality score and a 20% decrease in the mean glandular dose. CONCLUSION: Mammography as practiced today is essentially a screen-film technique. Mammographic phantom image quality has improved considerably. The overall mean glandular dose has decreased primarily because of the elimination of xeroradiography.  相似文献   

16.
The acceptance of the Digital Imaging and Communication in Medicine (DICOM) standard and the Compact Disk-Recordable (CD-R) as the interchange medium have been critical developments for laboratories that need to move forward on the cine replacement front, while at the same time retain a means to communicate with other centers. One remaining essential component which has not been satisfactorily addressed is the issue of how digital image data should be archived within an institution. Every laboratory must consider the diverse issues which affect the choice of a digital archiving system. These factors include technical and economic issues, along with the clinical routines prevailing in their laboratory. A complete understanding of the issues will lead to the formulation of multiple options which may prove acceptable and will help to overcome the last obstacle which remains for the complete replacement of cine film in the cardiac catheterization laboratory.  相似文献   

17.
PURPOSE: Since the routine use of storage phosphor systems for mammography has been limited by its inadequate spatial resolution of 5 linepairs/mm, a combination of a magnification mammography technique with storage phosphor plates was investigated to detect microcalcifications. MATERIAL AND METHODS: A new mammography system with a microfocus tube using an anode of 0.05-0.12 mm allowed to obtain survey views of the breast with 1.7x magnification (m), and spot views with 4x magnification. The digital image receptor comprised a high resolution storage phosphor plate. To determine spatial resolution, contrast transfer curves were obtained, and the detection of microcalcifications was investigated by ROC (receiver operating characteristic) analysis. RESULTS: Spatial resolution for digital survey views (m = 1.7) was 8 linepairs/mm and for spot views (m = 4) was 18 linepairs/mm. ROC analysis demonstrated a significantly higher performance of the digital magnification technique compared to the conventional screen-film mammography technique. CONCLUSIONS: The limitations of digital mammography with respect to spatial resolution can be overcome by using a high magnification technique.  相似文献   

18.
Argues that numerous issues directly relevant to the field of personality and social psychology are present and may become increasingly important in the US space program. It is suggested that data from personality and social psychology have been underused resources in the US space program. The responsibility for this outcome is seen as resting both with investigators and in structural aspects of the National Aeronautics and Space Administration. The contrasting centrality of psychology in the Russian space program is noted. Suggestions for increasing the role of personality and social psychology in the US space program are offered. (25 ref) (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

19.
OBJECTIVES: This study examined the impact of state legislation on mammography quality and access in Michigan. METHODS: The impact of state legislation was analyzed with respect to utilization, numbers of machines and facilities, and image quality. RESULTS: The legislation had a positive effect on image quality improvement, had no impact on utilization by women aged 50 years and above, and resulted in few facility closures. CONCLUSIONS: Michigan's legislative intervention appears to have had a positive effect on efforts to improve mammography quality assurance with implications for other federal and state efforts to achieve quality assurance in health care delivery.  相似文献   

20.
Although teleradiology systems are available commercially, they are expensive ($30,000), and different makes are incompatible with each other, making them unusable for interhospital image transfers. Standard components were added to a personal computer (PC) to build a functional teleradiology unit capable of interhospital image transmission at a low cost ($600 upgrade). This PC teleradiology system was studied to assess its accuracy in the interpretation of soft-tissue lateral neck x-rays with epiglottitis or retropharyngeal abscesses and elbow x-rays with joint effusions, fractures, or both. A radiologist and a pediatric emergency physician were asked to read the PC teleradiology images. Both physicians read 13 of 13 soft-tissue lateral neck x-rays and 15 of 15 elbow x-rays correctly. This study supports the premise that PC teleradiology can be used to facilitate telephone consultation and patient transfers between tertiary pediatric emergency centers by transmitting pertinent radiographic information over a phone line. Although verbal communication can often suffice in a telephone consultation or transfer, there are many instances when visualizing a radiographic image such as an x-ray or computed tomography scan can provide important information that cannot be optimally described verbally. Rural hospitals can form interhospital image transmission links with tertiary center resources. Tertiary centers may elect to organize interhospital image transmission and referral networks with their rural hospital sources.  相似文献   