共查询到20条相似文献,搜索用时 15 毫秒
1.
We study atomic-resolution annular electron energy-loss spectroscopy (AEELS) in scanning transmission electron microscopy (STEM) imaging with experiments and numerical simulations. In this technique the central part of the bright field disk is blocked by a beam stop, forming an annular entry aperture to the spectrometer. The EELS signal thus arises only from electrons scattered inelastically to angles defined by the aperture. It will be shown that this method is more robust than conventional EELS imaging to variations in specimen thickness and can also provide higher spatial resolution. This raises the possibility of lattice resolution imaging of lighter elements or ionization edges previously considered unsuitable for EELS imaging. 相似文献
2.
Two independent strategies are presented for reducing the computation time of multislice simulations of scanning transmission electron microscope (STEM) images: (1) optimal probe sampling, and (2) the use of desktop graphics processing units. The first strategy is applicable to STEM images generated by elastic and/or inelastic scattering, and requires minimal effort for its implementation. Used together, these two strategies can reduce typical computation times from days to hours, allowing practical simulation of STEM images of general atomic structures on a desktop computer. 相似文献
3.
D. J. WALLIS N. D. Browning C. M. Megaridis & P. D. Nellist 《Journal of microscopy》1996,184(3):185-194
The chemical reactions that take place at surfaces as well as internally in nanoscale particles are of great scientific interest. Such reactions control the catalytic properties of small metal particles and thus are technologically very important. In order to allow enhancement of the performance of such catalytic systems, an understanding of the processes taking place at the atomic scale is necessary. Z-contrast imaging and electron energy-loss spectroscopy (EELS) in the dedicated scanning transmission electron microscope can give atomic-scale information and thus provide a unique opportunity to study such nanoscale systems. Here, iron particles from known positions in a ferrocene-seeded flame and their effects on soot formation are studied. Using EELS, spatial variations in oxidation state of the metal atoms are detected across individual nanometre-sized particles collected from the post-flame region. The surfaces of these particles are found to be less oxidized than their centres. Additionally, the particles are imaged with atomic resolution allowing their structure to be identified. Using these results and those for particles collected from in-flame regions, direct evidence is provided for the catalytic role of Fe-containing particles in the removal of carbonaceous soot produced during combustion of hydrocarbon-based fuels. 相似文献
4.
Eisaku Oho Misuzu Baba Norio Baba Yoshinori Muranaka Toshihide Sasaki Koichi Adachi Masako Osumi Koichi Kanaya 《Microscopy research and technique》1987,6(1):15-30
Recently, the reliability of field-emission electron guns has increased. In addition, the cost of computer systems for on-line processing has dropped. Hence, we should now consider the use of scanning transmission electron microscopy (STEM) for routine work, especially, in the field of biology where one may expect to utilize digital image processing techniques. An STEM has been constructed, without disturbing the original functions, by converting a commercial scanning electron microscope equipped with a fieldemission gun. The STEM is generally operated at accelerating voltage 30 kV, focal length 7.5 mm, and beam current 1?2 × 10?10 A. Several improvements have been incorporated for removing the effects of vibration, contamination, and stray magnetic fields. Also, an adjustable detector aperture was utilized. The modified instrument was connected to an on-line digital image processing system for utilizing the information obtained from STEM images. The advantages of the modified system were studied from various viewpoints. 相似文献
5.
H. F. KNAPP R. WYSS R. HRING C. HENN R. GUCKENBERGER A. ENGEL 《Journal of microscopy》1995,177(1):31-42
A hybrid scanning transmission electron/scanning tunnelling microscope vacuum system is introduced, which allows freeze drying and metal coating of biological samples and their simultaneous observation by scanning transmission electron microscopy and scanning tunnelling microscopy (STM). Different metal coatings and STM tips were analysed to obtain the highest possible resolution for such a system. Bovine liver catalase was used as a test sample and the STM results are compared to a molecular scale model. 相似文献
6.
The scanning transmission electron microscope constructed at Johns Hopkins follows the general layout of the first instrument at the University of Chicago. It is currently operating at 50 kV with a resolution of about 3 A. Its detector scheme consists of scintillation crystals coupled to photomultipliers in such a way as to eliminate introduction of unnecessary statistical noise. A unique alignment scheme utilizes the spherical aberration of the objective lens. 相似文献
7.
A scanning transmission electron microscope (STEM) produces a convergent beam electron diffraction pattern at each position of a raster scan with a focused electron beam, but recording this information poses major challenges for gathering and storing such large data sets in a timely manner and with sufficient dynamic range. To investigate the crystalline structure of materials, a 16×16 analog pixel array detector (PAD) is used to replace the traditional detectors and retain the diffraction information at every STEM raster position. The PAD, unlike a charge-coupled device (CCD) or photomultiplier tube (PMT), directly images 120–200 keV electrons with relatively little radiation damage, exhibits no afterglow and limits crosstalk between adjacent pixels. Traditional STEM imaging modes can still be performed by the PAD with a 1.1 kHz frame rate, which allows post-acquisition control over imaging conditions and enables novel imaging techniques based on the retained crystalline information. Techniques for rapid, semi-automatic crystal grain segmentation with sub-nanometer resolution are described using cross-correlation, sub-region integration, and other post-processing methods. 相似文献
8.
JIANGLIN FENG REW P. SOMLYO AVRIL V. SOMLYO & ZHIFENG SHAO 《Journal of microscopy》2007,228(3):406-412
We report the successful implementation of a fully automated tomographic data collection system in scanning transmission electron microscopy (STEM) mode. Autotracking is carried out by combining mechanical and electronic corrections for specimen movement. Autofocusing is based on contrast difference of a focus series of a small sample area. The focus gradient that exists in normal images due to specimen tilt is effectively removed by using dynamic focusing. An advantage of STEM tomography with dynamic focusing over TEM tomography is its ability to reconstruct large objects with a potentially higher resolution. 相似文献
9.
Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equipped with a nanotip electron gun can provide images with higher spatial resolution and with better signal-to-noise ratio. This could present a considerable advantage over the current SEM electron gun technology if the tips are sufficiently long-lasting and stable for practical use. In this study, an older field-emission critical dimension (CD) SEM was used as an experimental test platform. Substitution of tungsten nanotips for the regular cathodes required modification of the electron gun circuitry and preparation of nanotips that properly fit the electron gun assembly. In addition, this work contains the results of the modeling and theoretical calculation of the electron gun performance for regular and nanotips, the preparation of the SEM including the design and assembly of a measuring system for essential instrument parameters, design and modification of the electron gun control electronics, development of a procedure for tip exchange, and tests of regular emitter, sharp emitter and nanotips. Nanotip fabrication and characterization procedures were also developed. Using a "sharp" tip as an intermediate to the nanotip clearly demonstrated an improvement in the performance of the test SEM. This and the results of the theoretical assessment gave support for the installation of the nanotips as the next step and pointed to potentially even better performance. Images taken with experimental nanotips showed a minimum two-fold improvement in resolution performance than the specification of the test SEM. The stability of the nanotip electron gun was excellent; the tip stayed useful for high-resolution imaging for several hours during many days of tests. The tip lifetime was found to be several months in light use. This paper summarizes the current state of the work and points to future possibilities that will open when electron guns can be designed to take full advantage of the nanotip electron emitters. 相似文献
10.
Murray Vernon King 《Microscopy research and technique》1988,8(4):389-390
A technique is described for preparing uniform, durable phosphor layers for viewing screens suitable for the transmission electron microscope; a settling procedure is used. The example described here is for a high-voltage instrument, but with adjustment of the coating density, the technique should be equally suitable for screen preparation for transmission electron microscopes that operate at lower acceleration voltages. 相似文献
11.
In the scanning transmission electron microscope, hardware aberration correctors can now correct for the positive spherical aberration of round electron lenses. These correctors make use of nonround optics such as hexapoles or octupoles, leading to the limiting aberrations often being of a nonround type. Here we explore the effect of a number of potential limiting aberrations on the imaging performance of the scanning transmission electron microscope through their resulting optical transfer functions. In particular, the response of the optical transfer function to changes in defocus are examined, given that this is the final aberration to be tuned just before image acquisition. The resulting three‐dimensional optical transfer functions also allow an assessment of the performance of a system for focal‐series experiments or optical sectioning applications. 相似文献
12.
In a dedicated scanning transmission electron microscope (STEM) secondary electron images with high spatial resolution and good contrast can be obtained. Two types of detector are described. These take into account the secondary electrons which depend on the post-specimen field strength of the objective lens. Due to the thinness of the samples and the collection geometry the images differ from those obtained in a convectional scanning microscope. Examples are given where secondary electron images augment the information obtained by the more commonly used imaging modes. 相似文献
13.
Felisari L Grillo V Jabeen F Rubini S Menozzi C Rossi F Martelli F 《Ultramicroscopy》2011,111(8):1018-1028
A dedicated specimen holder has been designed to perform low-voltage scanning transmission electron microscopy in dark field mode. Different test samples, namely InGaAs/GaAs quantum wells, InGaAs nanowires and thick InGaAs layers, have been analysed to test the reliability of the model based on the proportionality to the specimen mass-thickness, generally used for image intensity interpretation of scattering contrast processes. We found that size of the probe, absorption and channelling must be taken into account to give a quantitative interpretation of image intensity. We develop a simple procedure to evaluate the probe-size effect and to obtain a quantitative indication of the absorption coefficient. Possible artefacts induced by channelling are pointed out. With the developed procedure, the low voltage approach can be successfully applied for quantitative compositional analysis. The method is then applied to the estimation of the In content in the core of InGaAs/GaAs core-shell nanowires. 相似文献
14.
Biological structures imaged in a hybrid scanning transmission electron microscope and scanning tunneling microscope 总被引:1,自引:0,他引:1
A hybrid scanning transmission electron microscope (STEM) and scanning tunneling microscope (STM) is described which allows simultaneous imaging of biological structures adsorbed to electron-transparent specimen supports in both modes of scanning microscopy, as demonstrated on uncoated phage T4 polyheads. We further discuss the reproducibility and validity of height data obtained from STM topographs of biomacromolecules and present raw data from topographs of freeze-dried, metal-coated nuclear envelopes from Xenopus laevis oocytes. 相似文献
15.
Rosenauer A Mehrtens T Müller K Gries K Schowalter M Satyam PV Bley S Tessarek C Hommel D Sebald K Seyfried M Gutowski J Avramescu A Engl K Lutgen S 《Ultramicroscopy》2011,111(8):1316-1327
We suggest a method for chemical mapping that is based on scanning transmission electron microscopy (STEM) imaging with a high-angle annular dark field (HAADF) detector. The analysis method uses a comparison of intensity normalized with respect to the incident electron beam with intensity calculated employing the frozen lattice approximation. This procedure is validated with an In0.07Ga0.93N layer with homogeneous In concentration, where the STEM results were compared with energy filtered imaging, strain state analysis and energy dispersive X-ray analysis. Good agreement was obtained, if the frozen lattice simulations took into account static atomic displacements, caused by the different covalent radii of In and Ga atoms. Using a sample with higher In concentration and series of 32 images taken within 42 min scan time, we did not find any indication for formation of In rich regions due to electron beam irradiation, which is reported in literature to occur for the parallel illumination mode. Image simulation of an In0.15Ga0.85N layer that was elastically relaxed with empirical Stillinger-Weber potentials did not reveal significant impact of lattice plane bending on STEM images as well as on the evaluated In concentration profiles for specimen thicknesses of 5, 15 and 50 nm. Image simulation of an abrupt interface between GaN and In0.15Ga0.85N for specimen thicknesses up to 200 nm showed that artificial blurring of interfaces is significantly smaller than expected from a simple geometrical model that is based on the beam convergence only. As an application of the method, we give evidence for the existence of In rich regions in an InGaN layer which shows signatures of quantum dot emission in microphotoluminescence spectroscopy experiments. 相似文献
16.
A type of artificial contrast found in annular dark-field imaging is generated by spatial interference between the scanning grating of the electron beam and the specimen atomic lattice. The contrast is analogous to moiré fringes observed in conventional transmission electron microscopy. We propose using this scanning interference for retrieving information about the atomic lattice structure at medium magnifications. Compared with the STEM atomic imaging at high magnifications, this approach might have several advantages including easy observation of lattice discontinuities and reduction of image degradation from carbon contamination and beam damage. Application of the technique to reveal the Burgers vector of misfit dislocations at the interface of epitaxial films is demonstrated and its potential for studying strain fields is discussed. 相似文献
17.
The numerical processing of electron microscope images is becoming important as more investigators need quantitative data on size and density of objects visualized by means of a STEM system [1–3]. We describe the hard- and software of a system for acquisition and processing of such images. Traditionally, the processed negatives of electromicrographs are scanned by a microdensitometer to provide a digital image [4,5]. We decided upon direct digitization of the transmission detector's output without intermediate optical or photochemical steps. The system's performance was tested on latex spheres. 相似文献
18.
Takaaki Kanemaru Kazuho Hirata Shin-ichi Takasu Shin-ichiro Isobe Keiji Mizuki Shuntaro Mataka Kei-ichiro Nakamura 《Ultramicroscopy》2009
Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital camera microscope unit and this hybrid instrument was named a fluorescence SEM (FL-SEM). In the labeling of FL-SEM samples, both Fluolid, which is an organic EL dye, and Alexa Fluor, were employed. We successfully demonstrated that the FL-SEM is a simple and practical tool for correlative fluorescence and electron microscopy. 相似文献
19.
A new cryo‐scanning transmission electron microscopy (cryo‐STEM) technique for imaging casein micelles in a field emission scanning electron microscope is presented. Thin films of micellar casein suspensions on lacey carbon grids were prepared using a modified sample holder developed by Gatan UK. Bright and dark field images were obtained at ?135°C showing casein micelles in their frozen hydrated state and in the size range 30–500 nm. Results were compared favorably with published images of casein micelles obtained with conventional cryo‐transmission electron microscopy, suggesting that cryo‐STEM is a useful alternative technique for visualizing food colloids close to their native state. SCANNING 32: 150–154, 2010. © 2010 Wiley Periodicals, Inc. 相似文献
20.
Depth sectioning in high angular annular dark field scanning transmission electron microscopy is considered a candidate for three-dimensional characterization on the atomic scale. However at present the depth resolution is still far from the atomic level, due to strong limitations in the opening angle of the beam. In this paper we introduce a new, parameter based tomographic reconstruction algorithm that allows to make maximal use of the prior knowledge about the constituent atom types and the microscope settings, so as to retrieve the atomic positions and push the resolution to the atomic level in all three dimensions. 相似文献