1.
本文以大庆市热计量试点项目中三栋建筑作为研究对象,测试了供热期间三栋试验建筑的耗热量,比较了传统建筑和安装温控阀建筑的节能潜力。安装温控阀的建筑单位采暖耗热量为21.8W/m^2,未安装温控阀的建筑采暖单位采暖耗热量为25.5W/m^2,节能潜力为13.3%;未安装温控阀的地板辐射采暖系统建筑单位采暖耗热量为31.2W/m^2,节能潜力达到32.8%。比较发现,只有安装温控阀的建筑单位采暖耗热量没有超过国家标准限值,其它两栋建筑单位采暖耗热量超标率分别为24.5%和41.8%。同时发现,地板辐射采暖系统建筑能源浪费严重,说明了实行供热计量的重要性和必要性。  相似文献   

2.
The building area in northern heating areas accounting for 70% of the total land area in China is 6,500,000,000 m2. The average heating energy consumption in northern China is 100–200% times more than developed countries in the same latitude. This paper introduced firstly the heat metering and energy efficiency retrofit background of existing residential buildings in northern heating areas of China organized by mohurd and MOF, and then put forward the total principle and contents of retrofit. Through analyzing some retrofit cases in Germany, Poland and China, some technological experiences were summarized and finally a technology line suitable for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China which involved retrofit for heat metering and temperature regulation of heating systems, heat balance of heat source and network, and building envelope was described to provide a systematic, scientific, technological guide for the retrofit projects of 0.15 billion m2 in “the Eleventh Five-Year Plan” period.  相似文献   

3.
吴曦  郁文红  蔡迎杰 《节能》2007,26(9):34-36
通过工程实例对我国节能建筑集中供暖热计量系统设计所存在的问题进行讨论。目前我国居住建筑集中供暖系统热计量设计模式单一,没有充分考虑我国国情和不同类型居住建筑的特点,加之我国的供热体制改革滞后,使得新建居住建筑的节能效果无法保证,还增加了工程建设费用。相关的技术规程予以补充和完善。  相似文献   

4.
Heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China is organized and implemented in a large scale by local government in 15 provinces of North China with the unified guidance and control of central government. Firstly, this paper introduced the target of energy-saving reformation of existing residential buildings in North China and the importance of check and evaluation on this target, then pointed out the necessity of building up an evaluation system for energy-saving retrofit. According to the analytical hierarchy process (AHP), three-grade evaluation system was built up for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China. Also, based on multi-index comprehensive evaluation method combined with life cycle assessment (LCA) theory, post-evaluation thought and successful degree evaluation method, a mathematical model was established. Finally, a set of scientific method for evaluating heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China systematically, scientifically, comprehensively and objectively was created.  相似文献   

5.
针对新疆地区集中供热事业面临的问题,价格主管部门进行的供热价格改革的研究。方法:2004~2005年供暖期间,在乌鲁木齐市选择三栋住宅楼进行热计量收费的试点,进行调研。结果:根据试点的情况,提出两种制定供热价格的方式。  相似文献   

6.
许富昌 《热能动力工程》2000,15(3):312-313,321
本文提出了一种具有分户供热和分户计量热量功能的采暖系统设计方案,可以利用简单热水表有效实施热量计量。  相似文献   

7.
In the existent paper, the performance of thermal storage hybrid buildings exploiting the latent heat of phase change materials (PCMs) for thermal refrigeration and heating of the contemporary period has been investigated. The conventional buildings consume a large amount of electricity, primarily for the heating and cooling applications. Electricity generation primarily relies on coal-based thermal power plants. The emissions from these establishments pose a serious threat to the environment. Moreover, conventional heating/cooling units rely on exorbitant energy cost. The usage of any kind of thermal storage system is an efficacious way of stockpiling thermal energy and utilizing it when needed. This paper gives a comprehensive overview of the available thermal storage units incorporating PCMs. The various segments of the buildings, viz, ceiling, window, wall, and floor have been analyzed in details. The results are quite promising in terms of load reduction and overall energy saving. Indoor surface temperature reduction of up to 7oC has been achieved. The energy saving of up to 40% can be realized by employing PCM. A comprehensive list of the PCMs is also tried to build up for end users according to their temperature requirement.  相似文献   

8.
In Sweden, where district heating accounts for a significant share of residential heating, it has been argued that improvements in end-use energy efficiency may be counter-productive since such measures reduce the potential of energy efficient combined heat and power production. In this paper we model how the potential trade-offs between energy supply and end-use technologies depend on climate policy and energy prices. The model optimizes a combination of energy efficiency measures, technologies and fuels for heat supply and district heating extensions over a 50 year period. We ask under what circumstances improved end-use efficiency may be cost-effective in buildings connected to district heating? The answer hinges on the available technologies for electricity production. In a scenario with no alternatives to basic condensing electricity production, high CO2 prices result in very high electricity prices, high profitability of combined heat and power production, and little incentive to reduce heat demand in buildings with district heating. In contrast, in a scenario where electricity production alternatives with low CO2 emissions are available, the electricity price will level out at high CO2 prices. This gives heat prices that increase with the CO2 price and make end-use efficiency cost-effective also in buildings with district heating.  相似文献   

9.
热流量计量分析与应用   总被引:3,自引:0,他引:3       下载免费PDF全文
阐述了蒸汽闭路循环系统的热能计量原理与方法,在一定的范围内,建立了过热水蒸气热和冷凝水热流量计算的数学模型;给出了闭路循环系统中用户实际消耗热能的计算式和计量方法,使热能计量更趋于合理。采用热能计量方法,促进了企业能源节约和合理使用,节能效果显著。  相似文献   

10.
To promote energy efficiency and emission reduction, the Chinese government has invested large amounts of resources in heat-metering reform over the past decade. However, heat-metering, which can reduce energy consumption by 15% at least in developed countries, is still not well known in China. This paper quantitatively analyzed the arousal effect of heat-metering policy on occupancy behavior regarding energy saving utilizing statistics method based on measured data of heating energy consumption of approximately 20000 users from 2008 to 2012 in Tianjin. The statistical data showed significant difference on energy consumption between users based on metering and based on area. The energy-saving rate in the heating season increased significantly from 4.11% in 2008–2009 to 10.27% in 2011–2012 as the implement of the heat-metering policy. The difference in energy-saving according to various outdoor temperatures showed that the energy-saving of occupancy behavior was more significant in a warm season than in a cold season. It also showed that the impact of heat-metering policy would be more pronounced in generally insulated buildings (15.55%) than in better insulated units (6.45%). Besides, this paper proposed some feasible suggestions for the formulation and implementation of heat-metering policy in northern heating areas of China.  相似文献   

11.
Individual metering of energy in flats is a real opportunity to save energy and money for the occupiers of collective-ownership buildings with centralised heating systems. The individual management of energy, through such devices, make users more responsible and also stimulates them to implement energy retrofit interventions in their flats. The use of individual metering systems in existing apartments, however, could have some critical aspects. The purpose of this paper is to analyse the application of individual energy systems in existing collective-ownership residential buildings, highlighting the critical aspects and providing practical solutions to overcome them. A study has been made of an individual metering application in an existing residential block of flats located in Milan (Italy) with poor thermal insulation between the various dwellings themselves and for the outside walls of the building. Although a net reduction of 50.4 % in the global costs for winter heating, obtained exclusively through plant-modification works, represents an optimum goal for energy savings, the study highlight some critical aspects. The savings for different apartments differ greatly and depend upon the criteria chosen for burden sharing. This study shows that the phenomenon of “heat theft” can prove to be important and provides the possibility of reducing to zero the quota of expenses from consumption whilst still benefiting from comfortable temperatures. Once the problems have been identified, the paper then proposes solutions to overcome them through a revision of the criteria for the allocation of energy costs.  相似文献   

12.
地源热泵结合地板辐射供暖系统在东北地区的应用前景   总被引:3,自引:0,他引:3  
将地源热泵与地板辐射采暖相结合用于东北地区供暖,末端实行分户热计量。该系统不仅节能环保,而且有利于加快供热体制改革的步伐。  相似文献   

13.
张会粉  张培  吕东岚  王可龙 《节能》2006,25(1):55-57
居住建筑的室内温度总是在高于规定温度的一定范围内波动。在建筑围护结构和管网敷设情况一定的情况下,供暖燃料的实际耗量只是随着室外气象条件的变化而变化。本文针对东营地区的地理位置和气候条件,采用理论分析和基本调查的方法给出了供暖期每天燃料耗量的具体算法,考虑了室外温度、天气情况和风速等三个因素对热耗量的影响。  相似文献   

14.
Based upon the results from extensive building monitoring and surveys on occupant’s behaviors in a representative nine-story apartment building in northern China, building energy simulations were performed to evaluate the impacts of integrative retrofits implemented. Integrative retrofits required by the newer building energy standard produced significant heating-energy savings (i.e., 53%) when compared with baseline buildings commonly built in early 1980s. Taking into account district-heating-system upgrades as part of integrative retrofit measures, a representative apartment building was 66% more efficient than the baseline building. Contrary to expectation, little behavioral change was found in response to the provisions of monetary incentive, billing-method reform, or metering of heating energy use in individual apartment units. Yet this paper identified sizable energy savings potential if occupants’ behavioral changes were to actually happen. This indicates that provisions of financial incentives or individual metering were insufficient for triggering substantial behavioral changes leading toward more energy savings in the current buildings. It is recommended that innovative energy policies, technology upgrades, and education would be needed to promote behavioral changes toward additional energy savings. Finally, measures and strategies to further enhance thermal integrity criteria (e.g., insulations of roof and balcony) are recommended in China’s future building energy policy reforms.  相似文献   

15.
张兴科 《中外能源》2012,17(3):32-36
减少我国冬季采暖所造成的大气污染,降低供暖系统的能耗,节约能源一直是建筑节能追求的目标.目前太阳能光伏发电已经成为人类利用太阳能的最主要方式之一,地源热泵已被作为一项旨在解决建筑冷热源问题的新技术,日渐受到人们的重视.将光伏转换与热泵循环有机结合在一起,从而形成了太阳能光伏-地源热泵系统.该系统提高了光电转换和光热吸收效率,光电/光热综合利用,极大地提高了单位面积太阳辐照的利用效率,同时可提高热泵系统在寒冷地区运行的适用性;利用光电效应把太阳能中高能带区域的光能直接转化成电能,可大大提高太阳能的可用能效率;在增加能量储存装置和逆变器的条件下,可以使系统脱离公用电网运行,从而增加了系统的适用性和灵活性;与普通的空气源热泵相比,太阳能地源热泵具有较高的热性能,具有一机多用的功效;与建筑物相结合的太阳能热泵系统,可以增加建筑物的隔热效果,起到减少建筑物冷暖负荷的作用,同时可极大地减少环境污染.  相似文献   

16.
The Danish government plans to make the Danish energy system to be completely free of fossil fuels by 2050 and that by 2035 the energy supply for buildings and electricity should be entirely based on renewable energy sources. To become independent from fossil fuels, it is necessary to reduce the energy consumption of the existing building stock, increase energy efficiency, and convert the present heat supply from fossil fuels to renewable energy sources. District heating is a sustainable way of providing space heating and domestic hot water to buildings in densely populated areas. This paper is a theoretical investigation of the district heating system in the Copenhagen area, in which heat conservation is related to the heat supply in buildings from an economic perspective. Supplying the existing building stock from low-temperature energy resources, e.g. geothermal heat, might lead to oversized heating plants that are too expensive to build in comparison with the potential energy savings in buildings. Long-term strategies for the existing building stock must ensure that costs are minimized and that investments in energy savings and new heating capacity are optimized and carried out at the right time.  相似文献   

17.
While the available resource in terms of waste process heat in the UK is substantial, there are a wide variety of issues to consider and barriers to overcome in order to realise its potential. This paper discusses one particular factor, namely public opinion. We describe the results of two focus groups with a potential domestic client group, namely elderly people, and the postal questionnaire responses of 323 individuals living in the proximity of a large potential heat source, namely the Corus steel-works in Port Talbot, Wales. While those questioned were broadly supportive of the idea of district heating, particularly if this would involve reductions in domestic heating costs, both the qualitative and quantitative work revealed significant concern about contractual lock-in. In contrast, the stability of long-term demand is highly valued by those responsible for the supply-side. We also observe some gender differences in first reactions to district heating and the role of environmental commitment. We conclude that while the results imply that an appeal to the environmental performance of district heating with waste heat may facilitate acceptance, trust-building and price inducements will also be required to overcome end-user concerns.  相似文献   

18.
The objective of the study is to analyse the conditions for connection of residential buildings in heat sparse areas to district heating systems in order to increase electricity production in municipal combined heat and power plants. The European electricity market has been assumed to be fully deregulated. The relation between connection of heat sparse areas, increased electricity and heat production as well as electricity prices, fuel prices and emissions rights is investigated. The results of the study show that there is potential to expand the district heating market to areas with lower heat concentrations in the cities of Gävle, Sandviken and Borlänge in Sweden, with both economic and environmental benefits. The expansion provides a substantial heat demand of approximately 181 GWh/year, which results in an electricity power production of approximately 43 GWh/year. Since the detached and stand-alone houses in the studied heat sparse areas have been heated either by oil boiler or by direct electricity, connection to district heating also provides a substantial reduction in emissions of CO2. The largest reductions in CO2 emissions are found to be 211 ktonnes/year assuming coal-fired condensing power as marginal electricity production. Connection of heat sparse areas to district heating decrease the system costs and provide a profitability by approximately 22 million EURO/year for the studied municipalities if the price of electricity is at a European level, i.e. 110 EURO/MWh. Sensitivity analysis shows, among other things, that a strong relation exists between the price of electricity and the profitability of connecting heat sparse areas to district heating systems.  相似文献   

19.
Yin  Shaowu  Shi  Yongle  Tong  Lige  Liu  Chuanping  Wang  Li  Ding  Yulong 《热科学学报(英文版)》2020,29(2):343-351
The working principle of a controllable on-demand heating system based on off-peak electricity energy storage(COHSBOEES) is as follows: the cheap off-peak electricity energy is converted into heat energy for storage in the evening, and the heat energy can be extracted on demand for heating during daytime peak or flat electricity periods. This technology can promote the smooth operation of the power grid, solve the problem of peak regulation for the electrical network, and promote renewable energy consumption. Based on the controllable on-demand heating strategy, a COHSBOEES for a heating area of 1000 m^2 was designed and built. Variations in the energy consumption and operating cost of the COHSBOEES in different heating situations were analyzed. The results showed that, off-peak electricity energy storage for heating was energy saving in comparison with central heating when the heating intensity of the COHSBOEES was 70 W/m^2 and the on-demand heating rate was less than 73.0%, and the off-peak electricity energy storage for heating was energy saving at any on-demand heating rate when the COHSBOEES had a heating intensity of 50 W/m^2. After the COHSBOEES has been running for three complete heating seasons, when the off-peak electricity price was 0.25 yuan/kW·h, the energy consumption cost of the COHSBOEES can be saved by 77.6% in comparison with central heating.  相似文献   

20.
On-site hydrogen production through steam-methane reforming (SMR) from city gas or natural gas is believed to be a cost-effective way for hydrogen-based infrastructure due to high cost of hydrogen transportation. In recent years, there have been a lot of on-site hydrogen fueling stations under design or construction in China. This study introduces current developments and technology prospects of skid-mounted SMR hydrogen generator. Also, technical solutions and economic analysis are discussed based on China's first on-site hydrogen fueling station project in Foshan. The cost of hydrogen product from skid-mounted SMR hydrogen generator is about 23 CNY/kg with 3.24 CNY/Nm3 natural gas. If hydrogen price is 60 CNY/kg, IRR of on-site hydrogen fueling station project reaches to 10.8%. While natural gas price fall to 2.3 CNY/Nm3, the hydrogen cost can be reduced to 18 CNY/kg, and IRR can be raised to 13.1%. The conclusion is that skid-mounted SMR technology has matured and is developing towards more compact and intelligent design, and will be a promising way for hydrogen fueling infrastructures in near future.  相似文献   