首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
采用电感耦合等离子体发射光谱法测定铜尾矿中铅、锌、砷、锑、铋、镁等6种元素,其测定范围ω(Pb):0.10%~2.50%;ω(Zn):0.50%~3.50%;ω(As):0.05%~0.35%;ω(Sb):0.01%~0.30%;ω(Bi):0.008%~0.20%;ω(Mg):0.10%~1.50%。经加标回收试验,各元素的加标回收率为96%~103%(n=3),相对标准偏差(RSD)小于4.7%(n=11)。这一方法准确、快速,适用于铜尾矿中铅、锌、砷、锑、铋、镁等元素含量的测定。  相似文献   

2.
采用盐酸-硝酸-氢氟酸并采用微波消解处理样品,高氯酸冒烟至尽干,加盐酸溶解盐类,选择Pb 220.353nm、Zn 206.200nm、Cu 327.393/Cu 324.752nm、As 193.696nm、Sb 206.836nm、Bi 190.171nm、Cd 214.440nm/Cd 226.502nm为分析谱线,使用电感耦合等离子体原子发射光谱法(ICP-AES)同时测定铅、锌、铜、砷、锑、铋、镉,从而建立了银精矿中铅、锌、铜、砷、锑、铋、镉等杂质元素的分析方法。铅、锌、锑在0.50%~5.00%,铜、铋在0.10%~5.00%,砷在0.10%~3.00%,镉在0.050%~0.50%范围内校准曲线呈线性,线性相关系数r均大于0.9999。方法中各元素的检出限为0.001%~0.014%。实验方法用于测定两个银精矿样品中铅、锌、铜、砷、锑、铋、镉,结果的相对标准偏差(RSD,n=11)为0.74%~2.9%,并与相应的国标方法测定值相吻合(其中铅和锌采用火焰原子吸收光谱法(YS/T 445.9—2001),铜采用火焰原子吸收光谱法(YS/T 445.2—2001),砷和铋采用氢化物发生-原子荧光光谱法(YS/T 445.3—2001),锑参照采用氢化物发生-原子荧光光谱法(YS/T 445.3—2001),镉采用原子吸收光谱法(YS/T 445.8—2001))。按照实验方法测定两个银精矿样品中铅、锌、铜、砷、锑、铋、镉,并进行加标回收试验,回收率为96%~105%。  相似文献   

3.
混合铅锌精矿化学分析方法中的砷、镉、铜等杂质的含量,是采用每个元素分别测定的方法,测定周期长,分析成本高。因此,作者提出采用一次溶样,用电感耦合等离子体原子发射光谱法(即ICP-AES法)对原标准中砷、镉、铜同时进行测定,并增加了钴、铋、镍、锑4种杂质元素的测定。经大量的试验和实际样品测定,结果表明该方法快速,准确、可靠,加标回收率均在95%~106%之间。能够满足混合铅锌精矿中砷、铋、镉、钴、铜、镍、锑含量的测定要求。  相似文献   

4.
程键 《冶金分析》2007,27(11):1-1
试验了电感耦合等离子体原子发射光谱法测定锌精矿及焙砂中铅、锑、砷、铜、镉、铁、钴、镍、银、铟10种杂质元素的方法,确立了最佳工作条件。样品用王水溶解,为防止锑的挥发,加入酒石酸作为络合剂。采用基体匹配方法消除基体干扰。标准加入回收率在95%~103%之间,相对标准偏差为0.5%~5.9%,应用于锌精矿及焙砂中杂质元质的测定,测定结果与化学法相符。  相似文献   

5.
建立了铝含量高的镍精矿中钙、镁、铝、锌、铬、铅和锰7种元素的电感耦合等离子体原子发射光谱测定方法。样品用无水碳酸钠和过氧化钠混合熔剂熔融,盐酸浸取、酸化。在选定的测量条件下,用电感耦合等离子体原子发射光谱法测定试液中7种元素含量。在最佳实验条件下,钙、镁、铝、锌、铬、铅和锰测定范围分别为0.50%~2.50%,0.50%~2.50%,0.50%~10.00%,0.005%~1.00%,0.005%~1.00%,0.005%~1.00%,0.005%~1.00%。精密度试验结果表明,样品中各元素测定结果的相对标准偏差(RSD)小于7%。  相似文献   

6.
锡精矿经盐酸和硝酸的混合酸消解,水解分离锡后,电感耦合等离子体原子发射光谱法测定锡精矿中的铅、砷、铜、锌、铋杂质元素。对溶样条件、测定介质、基体及共存元素间干扰进行了相关讨论;20倍的镁、钙、钨,100倍的硅和质量分数小于10%的铁等共存元素对待测元素几乎没有干扰。方法基体效应较小,各待测元素之间也没有明显干扰。在仪器最佳工作条件下,方法的回收率为85%~102%,相对标准偏差(RSD,n=12)为0.91%~2.36%。使用该法分析标准物质和实际样品,分析结果与认定值或其他常规方法测定值一致,均在允许误  相似文献   

7.
采用富氧底吹"三连炉"造锍捕金工艺处理高砷锑复杂难处理金精矿,实现多金属高效回收。针对复杂金精矿火法处理工艺中金属收得率和工艺调控需求,结合生产实践总结了多种杂质元素分配行为与规律,优化了配矿中不同杂质元素含量,并对不同复杂金精矿在熔炼过程中的铜锍品位进行有针对性的调控,即高砷物料铜锍品位控制在65%,高铅物料铜锍品位控制在72%。可实现复杂难处理金精矿三连炉熔炼中铅、锌、砷、锑、铋、镍整体脱除率达98%以上,为黄金行业绿色冶炼及可持续发展提供参考。  相似文献   

8.
杨峥  梁钪  张艳  刘喜山  庞晓辉  高颂 《冶金分析》2021,40(11):63-70
铜冶炼烟尘中含有较高含量的铅、铜、砷、铝、铁、锑、铋等元素,对滴定法测镉产生干扰。采用氟化铵-盐酸-硝酸-高氯酸分解试样,用氢溴酸除去砷、锑、锡等干扰元素。硫酸铅沉淀分离铅,氨水沉淀分离铁、铋、部分铝等共存元素,在稀硫酸介质中加入硫代硫酸钠使铜离子以硫化亚铜状态从溶液中分离,滤液中加入过量的Na2EDTA标准滴定溶液,加入氟化钾掩蔽剩余铝,在pH 5.5~5.6的盐酸-六次甲基四胺缓冲溶液中,以二甲酚橙为指示剂,用锌标准滴定溶液返滴定。测得结果为锌、镉合量,扣除锌量,即为镉量。优化了氨水用量、氟化钾用量等实验条件,建立了Na2EDTA返滴定法测定铜冶炼烟尘中镉含量的方法。方法用于测定铜冶炼烟尘中镉,结果与电感耦合等离子体原子发射光谱法(ICP-AES)一致,结果的相对标准偏差(RSD,n=11)为0.56%~0.92%。按照实验方法对铜冶炼烟尘样品进行加标回收试验,回收率为99.6%~100.2%。  相似文献   

9.
石镇泰  罗文蕊 《冶金分析》2012,32(11):61-66
通过采用硫酸沉淀分离基体铅和选择合适的分析线及背景校正方法消除基体和共存元素干扰,实现了高纯铅中痕量杂质元素砷、铋、铜、锑、锡、锌、铁的电感耦合等离子体原子发射光谱法测定。对仪器的各项测定参数进行优化并将所建立的测定方法应用于实际样品分析,结果表明:用本法测定高纯铅标准样品中砷、铋、铜、锑、锡、锌、铁,测定值与认定值相符,测定结果的相对标准偏差均小于7%。  相似文献   

10.
银精矿中铋元素含量直接影响到冶炼工艺的选取和金属平衡管理,是评价银精矿的重要指标,但对于高铋银精矿中大于5%(质量分数)铋的测定方法还鲜见报道,因此迫切需要一种快速、准确的检测高铋银精矿中铋的方法。采用波长色散X射线荧光光谱仪(WDXRF)、高频红外碳硫分析仪对高铋银精矿试样进行半定量成分分析,确定其主要含有银、铅、铋、铜、锑、铁、硫、硅、碳等元素。在此基础上,对溶样体系及共存元素的干扰和消除方法进行了探讨,结果表明,以盐酸-硝酸-高氯酸-氢溴酸体系溶解试样后溶液清亮,终点明显;利用盐酸挥发去除样品中硫,硝酸和高氯酸加热至冒浓烟除碳;采用氢溴酸挥发2次的溶样方式可基本将砷、锡、硒挥发完全,大部分锑也会被挥发出去,残留的少部分锑可通过加入5mL 100g/L酒石酸溶液的方式来掩蔽;加入5mL饱和硫脲溶液可掩蔽铜;加入0.2g抗坏血酸可掩蔽铁(III);其他共存元素的干扰试验表明,试样中的银、铅、锌、镉、镁、钼对测定的干扰可忽略。用饱和乙酸铵溶液和硝酸(4+96)调节样品溶液pH值至1.5~1.7,以EDTA标准滴定溶液滴定铋,建立了EDTA滴定法测定高铋银精矿中铋的方法。按照实验方法对3个高铋银精矿样品中铋进行加标回收试验,回收率为98%~102%。实验方法用于测定5个高铋银精矿样品中铋,测定结果的相对标准偏差(RSD,n=11)为0.39%~0.87%,所得结果与电感耦合等离子体原子发射光谱法(ICP-AES)测定结果相吻合。  相似文献   

11.
12.
ICP-AES法测定铍铜合金中Be, Ni, Ti, Co, Fe, Al, Si, Mg和Pb   总被引:3,自引:0,他引:3  
通过操作条件的试验研究,用基体匹配法校正基体干扰,并选择了最佳工作条件。样品加标回收率为96%~110%,方法快速、简便、可靠,适用于铍铜合金的快速检验。  相似文献   

13.
The erm family of 23S rRNA adenine-N6-methyltransferases confers resistance to all macrolide-lincosamide-streptograminB (MLS) antibiotics, but not all MLS antibiotics induce synthesis of Erm methyltransferase with equal efficiency in a given organism. The induction efficiency of a test panel of MLS antibiotics was studied by using two translational attenuator-lac reporter gene fusion constructs, one based on ermSV from Streptomyces viridochromogenes NRRL 2860 and the other based on ermC from Staphylococcus aureus RN2442. Four types of responses which were correlated with the macrolide ring size were seen, as follows: group 1, both ermSV and ermC were induced by the 14-membered-ring macrolides erythromycin, lankamycin, and matromycin, as well as by the lincosamide celesticetin; group 2, neither ermSV nor ermC was induced by the 12-membered-ring macrolide methymycin or by the lincosamide lincomycin or the streptogramin type B antibiotic ostreogrycin B; group 3, ermSV was selectively induced over ermC by the 16-membered-ring macrolides carbomycin, chalcomycin, cirramycin, kitasamycin, maridomycin, and tylosin; and group 4, ermC was selectively induced over ermSV by the 14-membered-ring macrolide megalomicin. These data suggest that the leader peptide determines the specificity of induction by different classes of MLS antibiotics and that for a given attenuator, a major factor which determines whether a given macrolide induces resistance is its size.  相似文献   

14.
臧慕文  刘英  王爱慈  张丽 《稀有金属》2005,29(4):397-402
试验研究建立了同一试料溶液连续、同时测定铂饰品中各成分的分析方法。主体Pt以氯铂酸铵称量法及火焰原子吸收光谱(FAAS)法或电感耦合等离子发射光谱(ICP-AES)法测定滤液中残留Pt进行补差而测定。主成分Pd,Au,Ag,Cu和焊料成分Ni,Zn,Fe以FAAS法或ICP-AES法测定。其方法回收率分别为:Pt99.9%~100%;Pd99.3%~99.7%;Au99.5%~l01.5%;Ag98.0%~100%;Cu97.7%~99.3%;Zn98.0%~99.0%;Ni94.0%~105%;Fe95.0%~99.0%。实际试样分析时,各成分质量分数之和一般在99.12%~l01.2%之间,接近于100%,间接说明方法的可靠性。本法适用于Pt-Pd二元体系和Pt-Pd-Au-Cu多元复杂体系的铂饰品的破坏分析,可用于校正X荧光光谱法无损检测铂饰品的分析结果。  相似文献   

15.
稀土金属中14种非稀土杂质的ICP-MS法同时测定   总被引:1,自引:0,他引:1  
本文研究了用 ICP- MS仪器同时测定稀土金属中 Mg、Al、Ti、Cr、Mo、Mn、Co、Ni、Cu、Zn、Pb、W、Nb、Ta等 14种非稀土杂质。研究了各稀土基体对被分析元素的基体效应 ,选择了相匹配的内标元素。比较了标准曲线法与标准加入法的测定结果。确定了用内标元素校正基体效应及仪器漂移 ,以标准曲线法直接测定。进行了加料回收和精密度实验 ,回收率在 94%~ 113%之间 ,RSD<10 %。被分析元素的检出限为 0 .0 1~ 0 .2 0 ng/ m L,测定下限为1~ 2 0 μg/ g。  相似文献   

16.
An insertable head gradient coil with a maximum gradient amplitude of 45 mT/m and a rise time of 150 musec along all three major axes was used to collect high-spatial-resolution, single-shot, spin-echo, echo-planar, diffusion-weighted magnetic resonance images with b values ranging from 0 to 2,200 sec/mm2. Improvements in spatial resolution allowed better visualization of large white matter tracts and their relation to adjacent anatomic structures. Excellent contrast and anatomic detail were revealed for most structures in the brain when a sufficient number of acquisitions were collected.  相似文献   

17.
土壤无机污染物铅、铬、镉、汞、砷、锌、铜、镍这八大重金属,是一般土壤检测中的必检项目。金属元素在土壤中积累富集后,有可能通过雨水迁移,造成地下水,地表水污染,或者通过农作物进入食物链,进而影响食品安全和人体健康,因此,对这些元素的检测显得尤为重要。本文采用原子荧光光谱法对土壤中的金属元素进行测量,同时结合微波消解技术对样品进行处理,确保测量数据的准确性。  相似文献   

18.
Agar dilution MICs of 10 agents against 410 non-Pseudomonas aeruginosa gram-negative nonfermentative rods were determined. MICs at which 50 and 90% of the isolates were inhibited, respectively, were as follows (in micrograms per milliliter): sparfloxacin, 0.5 and 8.0; levofloxacin, 1.0 and 8.0; ciprofloxacin, 2.0 and 32.0; ofloxacin, 2.0 and 32.0; D-ofloxacin, 32.0 and > 64.0; ceftazidime, 8.0 and 64.0; piperacillin with or without tazobactam, 16.0 and > 64.0; trimethoprim-sulfamethoxazole, 0.5 and > 64.0; imipenem, 2.0 and > 64.0. With the exception of those for Stenotrophomonas maltophilia, Burkholderia cepacia, and Alcaligenes faecalis-A. odorans, agar dilution MICs for all strains tested were within 1 dilution of inhibitory (bacteriostatic) levels as determined by time-kill methodology.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号