首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experiments were performed to examine the feasibility of mass spectrometry (MS) depth profiling of animal tissue by ~75 fs, 800 nm laser pulses to expose underlying layers of tissue for subsequent MS analysis. Matrix assisted laser desorption ionization mass spectrometry (MALDI-MS) was used to analyze phospholipids and proteins from both intact bovine eye lens tissue and tissue ablated by ultrashort laser pulses. Laser desorption postionization mass spectrometry (LDPI-MS) with 10.5 eV single photon ionization was also used to analyze cholesterol and other small molecules in the tissue before and after laser ablation. Scanning electron microscopy was applied to examine the ablation patterns in the tissue and estimate the depth of the ablation craters. Ultrashort pulse laser ablation was found to be able to remove a layer of several tens of micrometers from the surface of eye lens tissue while leaving the underlying tissue relatively undamaged for subsequent MS analysis. MS analysis of cholesterol, phospholipids, peptides, and various unidentified species did not reveal any chemical damage caused by ultrashort pulse laser ablation for analytes smaller than ~6 kDa. However, a drop in intensity of larger protein ions was detected by MALDI-MS following laser ablation. An additional advantage was that ablated tissue displayed up to an order of magnitude higher signal intensities than intact tissue when subsequently analyzed by MS. These results support the use of ultrashort pulse laser ablation in combination with MS analysis to permit depth profiling of animal tissue.  相似文献   

2.
Zhu K  Kim J  Yoo C  Miller FR  Lubman DM 《Analytical chemistry》2003,75(22):6209-6217
A method has been developed for high sequence coverage analysis of proteins isolated from breast cancer cell lines. Intact proteins are isolated using multidimensional liquid-phase separations that permit the collection of individual protein fractions. Protein digests are then analyzed by both matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) peptide mass fingerprinting and by capillary electrophoresis-electrospray ionization (CE-ESI)-TOF MS peptide mapping. These methods can be readily interfaced to the relatively clean proteins resulting from liquid-phase fractionation of cell lysates with little sample preparation. Using combined sequence information provided by both mapping methods, 100% sequence coverage is often obtained for smaller proteins, while for larger proteins up to 75 kDa, over 90% coverage can be obtained. Furthermore, an accurate intact protein MW value (within 150 ppm) can be obtained from ESI-TOF MS. The intact MW together with high coverage sequence information provides accurate identification. More notably the high sequence coverage of CE-ESI-TOF MS together with the MS/MS information provided by the ion trap/reTOF MS elucidates posttranslational modifications, sequence changes, truncations, and isoforms that may otherwise go undetected when standard MALDI-MS peptide fingerprinting is used. This capability is critical in the analysis of human cancer cells where large numbers of expressed proteins are modified, and these modifications may play an important role in the cancer process.  相似文献   

3.
The small molecular analyte 3,5-dibromotyrosine (Br(2)Y) and chitosan-alginate polyelectrolyte multilayers (PEM) with and without adsorbed Br(2)Y were analyzed by laser desorption postionization-mass spectrometry (LDPI-MS). LDPI-MS using a 7.87 eV laser and tunable 8-12.5 eV synchrotron vacuum ultraviolet (VUV) radiation found that desorption of clusters from Br(2)Y films allowed detection by ≤8 eV single photon ionization. Thermal desorption and electronic structure calculations determined the ionization energy of Br(2)Y to be ~8.3 ± 0.1 eV and further indicated that the lower ionization energies of clusters permitted their detection at ≤8 eV photon energies. However, single photon ionization could only detect Br(2)Y adsorbed within PEMs when using either higher photon energies or matrix addition to the sample. All samples were also analyzed by 25 keV Bi(3)(+) secondary ion mass spectrometry (SIMS), with the negative ion spectra showing strong parent ion signal which complemented that observed by LDPI-MS. However, the negative ion SIMS appeared strongly dependent on the high electron affinity of this specific analyte and the analyte's condensed phase environment.  相似文献   

4.
Vacuum and extreme ultraviolet radiation from 8 - 24 eV generated at a synchrotron was used to postionize laser desorbed neutrals of antibiotic-treated biofilms and a modified fullerene using laser desorption postionization mass spectrometry (LDPI-MS). Results show detection of the parent ion, various fragments, and extracellular material from biofilms using LDPI-MS with both vacuum and extreme ultraviolet photons. Parent ions were observed for both cases, but extreme ultraviolet photons (16 - 24 eV) induced more fragmentation than vacuum ultraviolet (8 - 14 eV) photons.  相似文献   

5.
Na DH  DeLuca PP  Lee KC 《Analytical chemistry》2004,76(9):2669-2673
A quantitative determination of peptides incorporated into poly(d,l-lactide-co-glycolide) microspheres by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was accomplished in a single step without pretreatment for extracting the peptide from the microsphere. The conventional extraction methods often underestimate the actual amount of peptide because of incomplete extraction from the microspheres or loss during the procedures. In this study, the microspheres dissolved in acetonitrile containing 0.1% trifluoroacetic acid were mixed with matrix solution containing the internal standard, and the peptide content was directly determined by MALDI-TOF MS. The drug content values determined by MALDI-TOF MS in both the leuprolide- and salmon calcitonin-incorporated microspheres were closer to the theoretical contents than those determined by the conventional extraction method. This method using MALDI-TOF MS could be a good alternative to time-consuming and less-accurate conventional methods.  相似文献   

6.
While matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has revolutionized the manner by which many large molecules are characterized, the highly variable appearance of MALDI mass spectra remains a concern. We have developed MALDI-based imaging as a diagnostic tool for examining the relationships between preparation strategy, sample morphology, and spectral quality. The imaging protocol involves the automated acquisition of mass spectra at 400-1600 positions within a single sample, followed by off-line processing and image display. Several sample types have been characterized, including a simple peptide mixture prepared in dried droplets of 2,5-dihydroxybenzoic acid and in thin films of alpha-cyano-4-hydroxycinnamic acid as well as a complex biological sample consisting of intact peptidergic neurons from the marine mollusk Aplysia californica. Imaging experiments provide a wealth of unbiased information concerning sample defects, spectral reproducibility, mass accuracy, differential analyte distributions, and the validity of internal standards.  相似文献   

7.
Stable-isotope dimethyl labeling for quantitative proteomics   总被引:1,自引:0,他引:1  
Hsu JL  Huang SY  Chow NH  Chen SH 《Analytical chemistry》2003,75(24):6843-6852
In this paper, we report a novel, stable-isotope labeling strategy for quantitative proteomics that uses a simple reagent, formaldehyde, to globally label the N-terminus and epsilon-amino group of Lys through reductive amination. This labeling strategy produces peaks differing by 28 mass units for each derivatized site relative to its nonderivatized counterpart and 4 mass units for each derivatized isotopic pair. This labeling reaction is fast (less than 5 min) and complete without any detectable byproducts based on the analysis of MALDI and LC/ESI-MS/MS spectra of both derivatized and nonderivatized peptide standards and tryptic peptides of hemoglobin molecules. The intensity of the a(1) and y(n-1) ions produced, which were not detectable from most of the nonderivatized fragments, was substantially enhanced upon labeling. We further tested the method based on the analysis of an isotopic pair of peptide standards and a pair of defined protein mixtures with known H/D ratios. Using LC/MS for quantification and LC/MS/MS for peptide sequencing, the results show a negligible isotopic effect, a good mass resolution between the isotopic pair, and a good correlation between the experimental and theoretical data (errors 0-4%). The relative standard deviation of H/D values calculated from peptides deduced from the same protein are less than 13%. The applicability of the method for quantitative protein profiling was also explored by analyzing changes in nuclear protein abundance in an immortalized E7 cell with and without arsenic treatment.  相似文献   

8.
We describe the impact of advances in mass measurement accuracy, +/- 10 ppm (internally calibrated), on protein identification experiments. This capability was brought about by delayed extraction techniques used in conjunction with matrix-assisted laser desorption ionization (MALDI) on a reflectron time-of-flight (TOF) mass spectrometer. This work explores the advantage of using accurate mass measurement (and thus constraint on the possible elemental composition of components in a protein digest) in strategies for searching protein, gene, and EST databases that employ (a) mass values alone, (b) fragment-ion tagging derived from MS/MS spectra, and (c) de novo interpretation of MS/MS spectra. Significant improvement in the discriminating power of database searches has been found using only molecular weight values (i.e., measured mass) of > 10 peptide masses. When MALDI-TOF instruments are able to achieve the +/- 0.5-5 ppm mass accuracy necessary to distinguish peptide elemental compositions, it is possible to match homologous proteins having > 70% sequence identity to the protein being analyzed. The combination of a +/- 10 ppm measured parent mass of a single tryptic peptide and the near-complete amino acid (AA) composition information from immonium ions generated by MS/MS is capable of tagging a peptide in a database because only a few sequence permutations > 11 AA's in length for an AA composition can ever be found in a proteome. De novo interpretation of peptide MS/MS spectra may be accomplished by altering our MS-Tag program to replace an entire database with calculation of only the sequence permutations possible from the accurate parent mass and immonium ion limited AA compositions. A hybrid strategy is employed using de novo MS/MS interpretation followed by text-based sequence similarity searching of a database.  相似文献   

9.
We report here the application of electrospray ionization tandem mass spectrometry for the characterization of protein ubiquitylation, an important posttranslational modification of cellular proteins. Trypsin digestion of ubiquitin-conjugated proteins produces diglycine branched peptides containing the modification sites. Chemical derivatization by N-terminal sulfonation was carried out on several model peptides for the formation of a characteristic fragmentation pattern in their MS/MS analysis. The fragmentation of derivatized singly charged peptides results in a product ion distribution similar to that already observed by MALDI-TOF MS/MS. Signature fragments distinguished the diglycine branched peptides from other modified and unmodified peptides, while the sequencing product ions reveal the amino acid sequence and the location of the ubiquitylation site. Doubly charged peptide derivatives fragment in a somewhat different manner, but several fragments characteristic to diglycine branched peptides were observed under low collision energy conditions. These signature peaks can also be used to identify peptides containing ubiquitylation sites. In addition, a marker ion corresponding to a glycine-modified lysine residue produced by high-energy fragmentation provides useful information for identity verification. The method is demonstrated by the analysis of three ubiquitin-conjugated proteins using LC/MS/MS.  相似文献   

10.
An approach for the characterization of glycosylation sites and oligosaccharide heterogeneity in glycoproteins based on a combination of nonspecific proteolysis, deglycosylation, and matrix-assisted laser desorption/ionization Fourier transform mass spectrometry (MALDI-FT MS) is described. Glycoproteins were digested with Pronase yielding primarily glycopeptides and amino acids. Nonglycosylated peptide fragments were susceptible to complete Pronase digestion to their constituent amino acids. Steric hindrance prohibited the digestion of the peptide moiety attached to the glycan. Glycopeptides were desalted and concentrated using solid-phase extraction and analyzed by MALDI MS. The oligosaccharides were also analyzed by MALDI MS after releasing the glycans from glycoproteins using PNGase F. The peptide moiety of the glycopeptides was identified by subtracting the masses of the glycans derived from PNGase F treatment from the masses of the glycopeptides. The experimental strategy was validated using glycoproteins with known oligosaccharide structures, ribonuclease B and chicken ovalbumin. This procedure was then used to determine the N-glycosylation sites and site heterogeneity of a glycoprotein whose glycosylation pattern was unknown, namely, the Xenopus laevis egg cortical granule lectin. This procedure is useful for determining protein site heterogeneity and structural heterogeneities of the oligosaccharide moiety of glycoproteins.  相似文献   

11.
Direct mass spectrometric quantification of peptides and proteins is compromised by the wide variabilities in ionization efficiency which are hallmarks of both the MALDI and ESI ionization techniques. We describe here the implementation of a fluorescence detection system for measurement of the UV-excited intrinsic fluorescence (UV-IF) from peptides and proteins just prior to their exit and electrospray ionization from an ESI capillary. The fluorescence signal provides a quantifiable measure of the amount of protein or peptide present, while direct or tandem mass spectrometric analysis (MS/MS) on the ESI-generated ions provides information on identity. We fabricated an inexpensive, modular fluorescence excitation and detection device utilizing an ultraviolet light-emitting diode for excitation in a ~300 nL fluorescence detection cell integrated into the fused-silica separation column. The fluorescence signal is linear over 3 orders of magnitude with on-column limits of detection in the low femtomole range. Chromatographically separated intact proteins analyzed using UV-IF prior to top-down mass spectrometry demonstrated sensitive detection of proteins as large as 77 kDa.  相似文献   

12.
The peptide content of individual mammalian cells is profiled using matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Both enzymatic and nonenzymatic procedures, including a glycerol cell stabilization method, are reported for the isolation of individual mammalian cells in a manner compatible with MALDI MS measurements. Guided microdeposition of MALDI matrix allows samples to be created with suitable analyte-to-matrix ratios. More than 15 peptides are observed in individual rat intermediate pituitary cells. The combination of accurate mass data, expected cleavages by proteolytic enzymes, and postsource decay sequencing allows identification of 14 of these peptides as pro-opiomelanocortin prohormone-derived molecules. These protocols permit the classification of individual mammalian cells by peptide profile, the elucidation of cell-specific prohormone processing, and the discovery of new signaling peptides on a cell-to-cell basis in a wide variety of mammalian cell types.  相似文献   

13.
A new sample ionization technique, atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI), was coupled with a commercial ion trap mass spectrometer. This configuration enables the application-specific selection of external atmospheric ionization sources: the electrospray/APCI (commercially available) and AP MALDI (built in-house), which can be readily interchanged within minutes. The detection limit of the novel AP MALDI/ion trap is 10-50 fmol of analyte deposited on the target surface for a four-component mixture of peptides with 800-1700 molecular weight. The possibility of peptide structural analysis by MS/MS and MS3 experiments for AP MALDI-generated ions was demonstrated for the first time.  相似文献   

14.
Ramos AA  Yang H  Rosen LE  Yao X 《Analytical chemistry》2006,78(18):6391-6397
Parallel fragmentations of peptides in the source region and in the collision cell of tandem mass spectrometers are sequentially combined to develop parallel collision-induced-dissociation mass spectrometry (p2CID MS). Compared to MS/MS spectra, the p2CID mass spectra show increased signal intensities (2-400-fold) and number of sequence ions. This improvement is attributed to the fact that p2CID MS virtually samples all the ions generated by electrospray ionization, including intact and fragment ions of different charge states from a peptide. We implement the method using a quadrupole time-of-flight tandem mass spectrometer. The instrument is operated in TOF-MS mode that allows the ions from source region broadband-passing the first mass analyzer to enter the collision cell. Cone voltage and collision energy are investigated to optimize the outcome of the two parallel CID processes. In the in-source parallel CID, elevated cone voltage produces singly charged intact peptide ions and large fragment ions, as well as decreases the charge-state distribution of peptide ions mainly to double and single charges. The in-collision-cell parallel CID is optimized to dissociate the ions from the source region to produce small and medium fragment ions. The method of p2CID MS is especially useful for sequencing of large peptides with labile amide bonds and peptides with C-terminal arginine. It has unique potential for de novo sequencing of peptides and proteome analysis, especially for affinity-enriched subproteomes.  相似文献   

15.
A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic and hydrophilic polypeptides in mixtures, thereby reducing the complexity of mass spectra obtained by MALDI MS. The LLE technique was optimized for rapid and sensitive in situ (on-target) sample preparation for MALDI MS analysis of proteins and peptides at low-picomole and subpicomole levels. Addition of MALDI matrix to the organic solvent enhanced the efficiency of the LLE-MALDI MS method for analysis of hydrophobic peptides and proteins. LLE-MALDI MS enabled the detection of the hydrophobic membrane protein bacteriorhodopsin as a component in a simple protein mixture. Peptide mixtures containing phosphorylated, glycosylated, or acylated peptides were successfully separated and analyzed by the in situ LLE-MALDI MS technique and demonstrate the potential of this method for enhanced separation and structural analysis of posttranslationally modified peptides in proteomics research.  相似文献   

16.
The large-scale identification and quantitation of proteins via nanoliquid chromatography (LC)-tandem mass spectrometry (MS/MS) offers a unique opportunity to gain unprecedented insight into the microbial composition and biomolecular activity of true environmental samples. However, in order to realize this potential for marine biofilms, new methods of protein extraction must be developed as many compounds naturally present in biofilms are known to interfere with common proteomic manipulations and LC-MS/MS techniques. In this study, we used amino acid analyses (AAA) and LC-MS/MS to compare the efficacy of three sample preparation methods [6 M guanidine hydrochloride (GuHCl) protein extraction + in-solution digestion + 2D LC; sodium dodecyl sulfate (SDS) protein extraction + 1D gel LC; phenol protein extraction + 1D gel LC] for the metaproteomic analyses of an environmental marine biofilm. The AAA demonstrated that proteins constitute 1.24% of the biofilm wet weight and that the compared methods varied in their protein extraction efficiencies (0.85-15.15%). Subsequent LC-MS/MS analyses revealed that the GuHCl method resulted in the greatest number of proteins identified by one or more peptides whereas the phenol method provided the greatest sequence coverage of identified proteins. As expected, metagenomic sequencing of the same biofilm sample enabled the creation of a searchable database that increased the number of protein identifications by 48.7% (≥1 peptide) or 54.7% (≥2 peptides) when compared to SwissProt database identifications. Taken together, our results provide methods and evidence-based recommendations to consider for qualitative or quantitative biofilm metaproteome experimental design.  相似文献   

17.
A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.  相似文献   

18.
Many drugs and chemicals exert their biological effect by modulating protein-protein interactions. In vitro approaches to characterize these mechanisms are often based on indirect measurements (e.g., fluorescence). Here, we used mass spectrometry (MS) to directly monitor the effect of small-molecule ligands on the binding of a coactivator peptide (SRC1) by the human estrogen receptor alpha ligand binding domain (hERalpha LBD). Nanoelectrospray mass spectrometry (nanoESI-MS) and high-mass matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) combined with chemical cross-linking were employed to follow these processes. The chemical cross-linking protocol used prior to high-mass MALDI analysis allows detection of intact noncovalent complexes. The binding of intact hERalpha LBD homodimer with two coactivator peptides was detected with nanoESI-MS and high-mass MALDI-MS only in the presence of an agonist ligand. Furthermore, high-mass MALDI-MS revealed an increase of the homodimer abundance after incubating the receptor with a ligand, independent of the ligand character (i.e., agonist, antagonist). The binding characteristics of the compounds tested by MS correlate very well with their biological activity reported by cell-based assays. High-mass MALDI appears to be an efficient and simple tool for directly monitoring ligand regulation mechanisms involved in protein-protein interactions. Furthermore, the combination of both MS methods allows identifying and characterizing endocrine-disrupting compounds or new drug compounds in an efficient way.  相似文献   

19.
Li X  Franke AA 《Analytical chemistry》2011,83(8):3192-3198
We report a new method for fast and sensitive analyses of biologically relevant fatty acids (FAs) in red blood cells (RBC) by liquid chromatography mass spectrometry (LC-MS). A new chemical derivatization approach was developed forming picolylamides from FAs in a quantitative reaction. Fourteen derivatized FA standards, including saturated and unsaturated FAs from C14 to C22, were efficiently separated within 15 min. In addition, the use of a recently introduced benchtop orbitrap mass spectrometer under positive electrospray ionization (ESI) full scan mode showed a 2-10-fold improvement in sensitivity compared with a conventional tandem MS method, with a limit of detection in the low femtomole range for saturated and unsaturated FAs. The developed method was applied to determine FA concentrations in RBC with intra- and interday coefficients of variation below 10%.  相似文献   

20.
MALDI mass spectrometry imaging (MSI) is a promising technique in the field of molecular (immuno)histology but is confronted with the problematic large-scale identification of peptides from thin tissue sections. In this study we present a workflow that significantly increased the number of identified peptides in a given MALDI-MSI data set and we evaluated its power concerning relative peptide quantifications. Fourier transform mass spectrometry (FTMS) profiling on matrix-coated thin tissue sections allowed us to align spectra of different MS sources, matching identical peaks in the process, thus linking MSI data to tandem mass spectrometry (MS/MS) on one hand and semiquantitative liquid chromatography (LC)/MS data on the other. Bonanza clustering was applied in order to group MS/MS spectra of structurally related peptides, making it possible to infer the identity of MSI-detected compounds based on identified members within the same cluster, effectively increasing the number of identifications in a single MSI data set. Out of 136 detected peptides with MALDI-MSI, we were able to identify 46 peptides. For 31 of these, a LC/quadrupole time-of-flight (QTOF) counterpart was detected, and we observed similar obese (ob/ob) to wild-type (wt) peak intensity ratios for 18 peptides. This workflow significantly increased the number of identifications of peptide masses detected with MALDI-MSI and evaluated the power of this imaging method for relative quantification of peptide levels between experimental conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号