首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Temperature gradient focusing (TGF) is a counterflow gradient focusing technique, which utilizes a temperature gradient across a microchannel or capillary to separate analytes. With an appropriate buffer, the temperature gradient creates a gradient in both the electric field and electrophoretic velocity. Combined with a bulk counter flow, ionic species concentrate at a unique point where the total velocity sums to zero and separate from each other. Scanning TGF uses varying bulk flow so that a large number of analytes that have large differences in electrophoretic mobility can be sequentially focused and passed by a single detection point. Up to now, scanning TGF examples have been performed using a linear temperature gradient which has limitations in improving peak capacity and resolution at the same time. In this work, we develop a bilinear temperature gradient along the separation channel that improves both peak capacity and separation resolution simultaneously. The temperature profile along the channel consists of a very sharp gradient used to preconcentrate the sample followed by a shallow gradient that increases separation resolution. A specialized design is developed for the heaters to achieve the bilinear profile using both analytical and numerical modeling. The heaters are integrated onto a hybrid PDMS/glass chip fabricated using conventional sputtering and soft-lithography techniques. Separation performance is characterized by separating several different dyes and amino acids that have close electrophoretic mobilities. Experiments show a dramatic improvement in peak capacity and resolution in comparison to the standard linear temperature gradient.  相似文献   

2.
We describe the serial combination of temperature gradient focusing (TGF) and field-amplified continuous sample injection (FACSI) for improved analyte enrichment and electrophoretic separation. TGF is a counterflow equilibrium gradient method for the simultaneous concentration and separation of analytes. When TGF is implemented with a low conductivity sample buffer and a (relatively) high conductivity separation buffer, a form of sample enrichment similar to field-amplified sample stacking (FASS) or field-amplified sample injection (FASI) is achieved in addition to the normal TGF sample enrichment. FACSI-TGF differs from FASI in two important respects: continuous sample injection, versus a discrete injection, is utilized; because of the counterflow employed for TGF, the stacking interface exists in a pseudo-stationary region outside of the separation column. Notably, analyte concentration enrichment factors greater than the ratio of separation and sample conductivities (gamma) were achieved in this method. For gamma=6.1, the concentration factor for one model analyte (Oregon Green 488) was found to be 36-fold higher with FACSI-TGF as compared to TGF without FACSI. A separation of five fluorescently labeled amino acids is also demonstrated with the technique, yielding an average enrichment of greater than 1000-fold.  相似文献   

3.
We present an experimental study of temperature gradient focusing (TGF) exploiting an inherent Joule heating phenomenon. A simple variable-width PDMS device delivers rapid and repeatable focusing of model analytes using significantly lower power than conventional TGF techniques. High electric potential applied to the device induces a temperature gradient within the microchannel due to the channel's variable width, and the temperature-dependent mobility of the analytes causes focusing at a specific location. The PDMS device also shows simultaneous separation and concentration capability of a mixture of two sample analytes in less than 10 min. An experiment combining Joule heating with external heating/cooling further supports the hypothesis that temperature is indeed the dominant factor in achieving focusing with this technique.  相似文献   

4.
A novel format for performing capillary isotachophoresis (ITP) is described -- gradient elution ITP (GEITP). GEITP merges the recently described electrophoretic separation technique of gradient elution moving boundary electrophoresis (GEMBE) with an ITP enrichment step. GEMBE utilizes a combination of continuous sample injection with a pressure-controlled counterflow; as the counterflow is reduced, analytes are sequentially eluted onto the separation column and detected as boundary interfaces. By incorporating leading electrolytes into the counterflow and terminating electrolytes into the sample matrix, an ionic interface can be formed near the capillary inlet. The discontinuous buffer system forms highly enriched analyte zones outside of the capillary, which are then eluted onto the separation capillary as the counterflow is reduced. Separation of fluorescent analytes was achieved either through discrete electrolyte spacers added to the sample or by using ampholyte mixtures to form a continuum of spacers. As the ITP process occurs off-column, extremely short length separations can be achieved, as demonstrated by a separation in 30 microm. The effects of various parameters on the GEITP enrichment process are investigated, including initial counterflow rates, electric field, leading electrolyte concentration, and counterflow acceleration, which is an adjustable parameter allowing for highly flexible separations. Typical enhancements in limits of detection and sensitivity were greater than 10,000-fold and were achieved in less than 2 min, yielding low-picomolar detection limits using arc lamp illumination and low-cost CCD detection. An optimized system afforded greater than 100,000-fold improvement in detection of carboxyfluorescein in 8 min. Specific examples of enrichment and separation demonstrated include the following: small dye molecules, DNA, amino acid mixtures, and protein mixtures.  相似文献   

5.
Temperature gradient focusing (TGF) is a recently developed technique for the simultaneous concentration and electrophoretic separation of ionic analytes in microfluidic channels. One drawback to TGF as it has previously been described is the limited peak capacity; only a small number of analyte peaks (approximately 2-3) can be simultaneously focused and separated. In this paper, we report on a variation of the TGF method whereby the bulk flow rate is varied over time so that a large number of analytes can be sequentially focused, moved past a fixed detection point, and flushed to waste. In addition to improved peak capacity, the detection limits of the scanning TGF method can be adjusted on-the-fly, as needed for different samples. Finally, scanning TGF provides a technique by which high-resolution, high-peak-capacity electrophoretic separations can be performed in simple, straight, and short microfluidic channels.  相似文献   

6.
We employed a liquid core waveguide to image both DNA electrophoresis separations and isoelectric focusing of proteins. The utility of the system is demonstrated for DNA fragment sizing and protein separations. The system utilizes the liquid-core waveguide as an efficient window for both the excitation of separated samples and the collection of light through total internal reflectance, with an ability to detect target molecules in the zeptomolar range. Scanning the excitation laser along the length of the electrophoresis capillary excites individually separated analyte bands, while the fluorescence is collected end-on by an optical fiber coupled to a photomultiplier, thus, creating an image of the separation along the length of the capillary.  相似文献   

7.
A novel method for performing electrophoretic separations is described-gradient elution moving boundary electrophoresis (GEMBE). The technique utilizes the electrophoretic migration of chemical species in combination with variable hydrodynamic bulk counterflow of the solution through a separation capillary or microfluidic channel. Continuous sample introduction is used, eliminating the need for a sample injection mechanism. Only analytes with an electrophoretic velocity greater than the counterflow velocity enter the separation channel. The counterflow velocity is varied over time so that each analyte is brought into the separation column at different times, allowing for high-resolution separations in very short channels. The new variable of bulk flow acceleration affords a new selectivity parameter to electrophoresis analogous to gradient elution compositions in chromatography. Because it does not require extra channels or access ports to form an injection zone and because separations can be performed in very short channels, GEMBE separations can be implemented in much smaller areas on a micro-fluidic chip as compared to conventional capillary electrophoresis. Demonstrations of GEMBE separations of small dye molecules, amino acids, DNA, and immunoassay products are presented. A low-cost, polymeric, eight-channel multiplexed microfluidic device was fabricated to demonstrate the reduced area requirements of GEMBE; the device was less than 1 in.2 in area and required only n + 1 fluidic access ports per n analyses (in this instance, nine ports for eight analyses). Parallel separations of fluorescein and carboxyfluorescein yielded less than 3% relative standard deviation (RSD) in interchannel migration times and less than 5% RSD in both peak and height measurements. The device was also used to generate a calibration curve for a homogeneous insulin immunoassay using each of the eight channels as a calibration point with less than 5% RSD at each point with replicate analyses.  相似文献   

8.
We report the use of a molecular micelle for the simultaneous separation and concentration of neutral and hydrophobic analytes using micellar affinity gradient focusing (MAGF). The technique, MAGF, combines the favorable features of micellar electrokinetic chromatography and temperature gradient focusing. The focusing of neutral coumarin analytes was accomplished by the use the molecular micelle, poly(sodium undecenyl sulfate) (poly-SUS). Concentration enhancements of 10-25-fold/min were achieved for focusing of the coumarin dyes. The effect of varying the temperature gradient on the resolution of two of the coumarin dyes was also investigated, demonstrating that improved resolution could be achieved by reducing the steepness of the temperature gradient. In addition, with scanning-mode MAGF (in which the peaks are sequentially scanned past a fixed detection point by varying the buffer counterflow velocity), the use of poly-SUS was shown to produce repeatable and quantitative analyte peaks, making quantitative separations possible with the MAGF technique. Finally, it was shown that peak areas could be increased in scanning MAGF by reducing the scan rate so that the sensitivity of the method can be adjusted as needed.  相似文献   

9.
A novel strategy for one-step concentration of analytes during capillary electrophoresis (CE) is presented. A short platinum wire was inserted into the 75-microm-i.d. separation capillary. When a high voltage was applied for CE separation, a sharp pH gradient along the capillary was created dynamically by the electrolysis of water in the running buffer. Concentration of a large volume of injected analytes was accomplished by the change in analyte charge due to the dynamic pH gradient. Depending on the polarity of the applied potential and the direction of electroosmotic flow, either anions or cations can be concentrated. Several hundredfold concentration factors were achieved. Fluorescence imaging by a CCD camera was used to monitor 10 cm of the capillary near the platinum wire during the concentration process. The observations are consistent with a sweeping mechanism.  相似文献   

10.
Dynamic pH junction is an on-line preconcentration method in capillary electrophoresis (CE) based on electrokinetic focusing of weakly ionic analytes with in large sample volumes in a multisection electrolyte system. In this report, experiments and computer simulations were performed to gain a better insight of the analyte focusing mechanism when a dynamic pH junction was used. A computer program, SIMUL, was used to simulate the band-narrowing process of a group for phenol derivatives under optimized buffer conditions, which were compared with experimental results. Computer simulations revealed the formation of a sharp moving pH boundary within the sample zone causing efficient focusing of long plugs of weakly acidic analytes based on their pKa. These studies offered useful information for understanding the band-narrowing process by control of the depth and lifetime of the moving pH boundary as a function of analyte pKa, sample pH, and injection length. The change in pH of the sample within the capillary was also estimated by measuring the absorbances of an analyte at two different wave-lengths. Optimization of analyte focusing resulted in enhanced detection responses of about 60-450-fold in terms of peak heights for some phenol derivatives' relation to conventional injections. Dynamic pH junction represents a novel approach to control band dispersion (peak width) and selectivity (mobility) of specific analytes for high-resolution CE separations.  相似文献   

11.
An interesting new approach to capillary affinity gel electrophoresis (CAGE) has been developed for the selective capture and separation of homopolymer and heteropolymer oligonucleotides. The combination of selectivity of bioaffinity recognition and high-resolution power of capillary gel electrophoresis allows the on-line sequence- and size-specific separation of oligonucleotides. Both rigid gel formulations and viscous replaceable polymer solutions having user-defined, single-stranded oligonucleotides covalently attached as recognition sequences are used. Contrary to most known affinity systems in capillary electrophoresis, which operate in a continuous mode, binding and release are accomplished in two steps, effectively separating the affinity from the separation step. At low temperature, oligonucleotides with complementary sequences in the analyte solution will bind to the immobilized recognition sequence while unrelated oligonucleotides will continue to migrate. This step is a preseparation, removing all nonspecific solutes from the sample. The release of the bound solutes is achieved at elevated temperature, allowing a probe of cross-reactivity for a given biorecognition element. Applications for high-resolution separations of short oligonucleotides and their mismatches are shown, and the potential for on-line preconcentration and separation of dilute analyte solutions, thus effectively enhancing the sensitivity, is demonstrated.  相似文献   

12.
Wei W  Yeung ES 《Analytical chemistry》2002,74(15):3899-3905
A novel approach for on-line concentration of proteins and peptides in capillary electrophoresis (CE) is presented. A short section (approximately 0.5-1 cm) along the capillary was etched with HF. The etched section became a porous membrane that allowed electrical conductivity but prevented passage of the analyte ions. The capillary was isolated into two parts by the etched section. Thus, we were able to use three buffer vials to perform CE experiments in the capillary by applying high voltages independently. Concentration and separation were performed at the two respective regions. When high voltage was applied to the concentration capillary (between the inlet end and the etched section), proteins and peptides were concentrated at the etched portion, because the porous capillary wall allowed only small buffer ions to pass through and there was no electric field gradient beyond that point. After focusing, the narrow sample zone was introduced into the separation capillary (between the etched section and the outlet end) by hydrodynamic flow or by electroosmotic flow. Finally, conventional CE was carried out for separation of the analytes. Several different concentration schemes for proteins and peptides were successfully demonstrated by using this new approach.  相似文献   

13.
Some basic aspects of capillary electrophoresis (CE) separations on a poly(methyl methacrylate) chip provided with two separation channels in the column-coupling (CC) configuration and on-column conductivity detectors were studied. The CE methods employed in this study included isotachophoresis (ITP), capillary zone electrophoresis (CZE), and CZE with on-line ITP sample pretreatment (ITP-CZE). Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed, and electrophoresis was a dominant transport process in the separations performed by these methods. Very reproducible migration velocities of the separated constituents were typical under such transport conditions, and consequently, test analytes could be quantified by various ITP techniques with 1-2% RSD. The CC configuration of the separation channels provides means for an effective combination of an enhanced load capacity of the separation system with high detection sensitivities for the analytes in concentration-cascade ITP separations. In this way, for example, succinate, acetate, and benzoate could be separated also in instances when they were present in the loaded sample (1.2 microL) at 1 mmol/L concentrations while their limits of detection ranged from 8 to 12 micromol/L concentrations. A well-defined ITP concentration of the analyte(s) combined with an in-column sample cleanup (via an electrophoretically driven removal of the matrix constituents from the separation compartment) can be integrated into the separations performed on the CC chip. These sample pretreatment capabilities were investigated in ITP-CZE separations of model samples in which nitrite, phosphate, and fluoride (each at a 10 micromol/L concentration) accompanied matrix constituents (sulfate and chloride) at considerably higher concentrations. Here, both the concentration of the analytes and cleanup of the sample were included in the ITP separation in the first separation channel while the second separation channel served for the CZE separation of the ITP pretreated sample and the detection of the analytes.  相似文献   

14.
The combination of several gradient modes (solvent, temperature, and flow programming) is rarely used in HPLC analysis. In this work, the separations obtained utilizing simultaneous flow and temperature gradient in capillary column and microcolumn HPLC were compared with the separations performed under isocratic, isothermal, and isorheic (constant flow) conditions. When the mobile phase flow rate and the column temperature were changed simultaneously during the separation run, the analysis time was shortened up to 50%, while the separation efficiency was preserved. The separations obtained with combined temperature and flow gradients show high reproducibility (relative standard deviation <2.0%), comparable to the reproducibility normally seen with a mobile phase gradient. For capillary HPLC, simultaneous temperature and flow programming is the method of choice because of the great technical difficulties involved in performing solvent gradient elution.  相似文献   

15.
It is generally acknowledged that enantiomer separations in capillary electrophoresis are based on differences in the affinities of the analyte enantiomers toward the chiral selector expressed as equilibrium constants of the resulting temporary diastereomeric associates. However, as can be derived from theoretical considerations, a separation of enantiomers by CE is in principle also possible solely based on differences in the mobilities of the temporary diastereomeric complexes per se, when equal binding constants between analyte enantiomers and the chiral selector are assumed and observed.  相似文献   

16.
A systematic study of selective analyte focusing in a multisection electrolyte system by capillary electrophoresis (CE) is presented. It was found that a dynamic pH junction between sample and background electrolyte zones can be used to focus zwitterionic catecholamines and weakly acidic compounds without the use of special ampholytes. Differences in pH and concentration of complexing agents, such as borate, in the sample and background electrolyte zones were determined to cause focusing through changes in the local velocity of the analyte in two different segments of the capillary. Velocity-difference induced focusing (V-DIF) of analytes using a dynamic pH junction allowed the injection of large sample volumes and significantly improved the concentration sensitivity of CE. Under optimized conditions, the limit of detection for epinephrine was determined to be about 4 x 10(-8) M (the original sample) with conventional UV absorbance detection. Moreover, separation efficiencies greater than a million theoretical plates can be achieved by focusing such large sample volumes into narrow zones. Multisection electrolyte systems, which lead to the formation of a dynamic pH junction, can be tuned toward improving the concentration sensitivity of specific analytes if their chemical properties are known.  相似文献   

17.
A method with the ability to increase greatly both the resolution and efficiency of a given capillary electrophoretic system is described. This method differs from traditional capillary electrophoresis (CE) in that a counterflow is induced in the direction opposite to the electrokinetic migration of the analyte. This has the effect of extending not only the time the analytes migrate in the electric field but also the effective length and the effective applied voltage of the system. Previous work in our group with flow counterbalanced capillary electrophoresis has utilized an open tube of small inner diameter to reduce peak broadening caused by hydrodynamic flow. Narrow-diameter capillaries (5-10 microm) restricted analysis to fluorescent analytes and laser-induced fluorescence detection. The method described here uses a capillary of much larger inner diameter (75 microm) that has been packed with nonporous silica particles. The packing material reduces the amount of band broadening caused by pressure-induced flow relative to that experienced in an open tube. A larger diameter capillary allows the detection of analytes by UV absorption, not only eliminating the need to tag analytes with fluorescent tags but also allowing for the detection of a much broader range of analytes. The system was evaluated by studying the separations of several enantiomers using only beta-cyclodextrin as the chiral selector. The system was also used to resolve the two naturally occurring isotopes of bromine and to resolve phenylalanine from phenylalanine-d8. Relative to traditional CE, large improvements in resolution and separation efficiency have been achieved with this method.  相似文献   

18.
An integrated proteome concentration/separation approach involving on-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed for providing significant analyte concentration and extremely high resolving power toward protein and peptide mixtures. Upon completion of analyte focusing, the self-sharpening effect greatly restricts analyte diffusion and contributes to analyte stacking in narrowly focused bands with a concentration factor of approximately 240. In addition to analyte focusing, CIEF as the first separation dimension resolves proteins/peptides on the basis of their differences in pI and offers greater resolving power than that achieved in strong cation exchange chromatography. The grouping of two highly resolving and completely orthogonal separation techniques of CIEF and CRPLC, together with analyte focusing and concentration, significantly enhances the dynamic range and sensitivity of conventional mass spectrometry toward the identification of low-abundance proteins. The CIEF-based multidimensional separation/concentration platform enables the identification of a greater number of yeast soluble proteins than methods presented in the literature, yet requires a protein loading of only 9.6 microg. This protein loading is 2-3 orders of magnitude lower than those employed by the reported non-gel-based proteome techniques. The distribution of a codon adaptation index value for identified yeast proteins approximates to that predicted for the entire yeast proteome and supports the capability of CIEF-based proteome separation technology for achieving comprehensive proteome analysis. By reducing the inner diameter of chromatography columns from 180 microm to 100 microm, the required protein loading is further decreased from 9.6 microg to 960 ng, illustrating the potential usage of this proteome technology for the analysis of protein profiles within small cell populations or limited tissue samples.  相似文献   

19.
A new technique is described for the concentration and separation of ionic species in solution within microchannels or capillaries. Concentration is achieved by balancing the electrophoretic velocity of an analyte against the bulk flow of solution in the presence of a temperature gradient. With an appropriate buffer, the temperature gradient can generate a corresponding gradient in the electrophoretic velocity, so that the electrophoretic and bulk velocities sum to zero at a unique point, and the analyte will be focused at that point. The technique is demonstrated for a variety of analytes, including fluorescent dyes, amino acids, DNA, proteins, and particles, and is shown to be capable of greater than 10,000-fold concentration of a dilute analyte.  相似文献   

20.
Electric field gradient focusing (EFGF) is an equilibrium gradient focusing technique that depends on an electric field gradient and a hydrodynamic counterflow to focus, concentrate, and separate charged analytes. In this work, EFGF devices were fabricated from poly(ethylene glycol) (PEG)-functionalized acrylic plastic. The separation channel was formed in an ionically conductive and protein-resistant PEG-functionalized hydrogel, which was cast in a changing cross-sectional cavity in the plastic device. A linear electric field gradient was obtained by applying a voltage lengthwise across the shaped hydrogel. Standard proteins were used as analytes to demonstrate the performance of these EFGF devices. With an increase in counterflow rate or decrease in applied voltage, analyte bands broadened, but resolution increased in agreement with theory. To reduce analyte band dispersion and improve focusing performance, a protein-compatible PEG-functionalized monolith was incorporated in the EFGF channel. Compared with focusing in an open channel, protein bands in the monolith-filled EFGF channel were significantly narrower.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号