首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A good route (template-directed synthetic route) for the fabrication of ZnO hollow nanospheres (ZnO-HNSPs) was proposed. ZnO hollow nanosphere is a wonderful platform to immobilize glucose oxidase for glucose biosensor owing to the high specific surface area and high isoelectric point (IEP). Along with nafion and glucose oxidase (GOD), a glucose sensor was designed. Nafion/ZnO-HNSPs/GOD/GCE displays higher catalytic activity toward the glucose oxidation than Nafion/ZnO nano-Flowers/GOD/GCE. Linear response was obtained over a concentration range from 5.0 × 10−3 mM to 13.15 mM with a detection limit of 1.0 μM (S/N = 3), and the sensitivity was 65.82 μA/(mM cm2). Satisfyingly, the Nafion/ZnO-HNSPs/GOD/GCE could effectively avoid the interferences from the common interfering species such as uric acid (UA), ascorbic acid (AA), dopamine (DA) and fructose. The Nafion/ZnO-HNSPs/GOD modified electrode allows high sensitivity, excellently selective, stable, and fast amperometric sensing of glucose and thus is promising for the future development of glucose sensors.  相似文献   

2.
A biosensor based on bovine serum albumin (BSA) and poly-o-phenylenediamine (PoPD)/carbon-coated nickel (C-Ni) nanobiocomposite film modified electrode has been developed to study the interaction of BSA with papaverine (PAP). The well-dispersed C-Ni nanoparticles were dripped onto the glassy carbon electrode (GCE) surface firstly, and PoPD films were subsequently electropolymerized by cyclic voltammetry (CV) to prepare PoPD/C-Ni/GCE. Finally, the BSA was easily immobilized on the PoPD films via electrostatic adsorption. The morphology and the electrochemical properties of the fabricated composite electrodes were examined by scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS), respectively. The interaction of PAP with BSA was monitored by differential pulse voltammetry (DPV), using PoPD as the electrochemical indicator. The binding constant (K), obtained by DPV, was 1.7 × 104 L/mol, which was consistent with the fluorescence analysis. This constructed biosensor also exhibited a fine linear correlation with PAP concentration range of 2.5 × 10−9-4.5 × 10−5 mol/L and a detection limit of 8.3 × 10−10 mol/L was achieved by DPV.  相似文献   

3.
In this work, an electrochemical sensor based on ordered mesoporous carbon (OMC) for the amperometric detection of isoniazid was developed. OMC was dispersed in a solution of Nafion, and the suspension was modified onto the surface of glassy carbon (GC) electrode. Cyclic voltammetry and amperometry were used to investigate the electrochemical behaviors of isoniazid on Nafion-OMC modified electrode (Nafion-OMC/GC). The results indicate that OMC can facilitate the electrochemical oxidation of isoniazid with a great decrease of overpotential in pH 7.0 phosphate buffer solution. The proposed biosensor provides excellent performance towards the determination of isoniazid with a high sensitivity of 0.031 μA/μM, a low detection limit of 8.4 × 10−8 M and wide linear range from 1.0 × 10−7 M to 3.7 × 10−4 M at +0.20 V vs. Ag/AgCl. The method was successfully applied to the determination of isoniazid tablets with satisfying results. All the results suggest that Nafion-OMC/GC electrode is a potential candidate for a stable and efficient electrochemical sensor to detect isoniazid.  相似文献   

4.
This article reports a new amperometric glucose biosensor based on ordered mesoporous carbon (OMC) supported platinum nanoparticles (Pt/OMC) modified electrode. The Pt/OMC nanocomposite modified electrode exhibited excellent electrocatalytic activities towards the reduction and oxidation of H2O2 as well. This feature allowed us to use it as bioplatform on which glucose oxidase (GOD) was immobilized by entrapment in electropolymerized pyrrole film for the construction of the glucose biosensor. The biosensor showed good analytical performances in terms of low detection (0.05 mM), high sensitivity (0.38 μA/mM) and wide linear range (0.05-3.70 mM). In addition, the effects of pH value, applied potential, electroactive interference and the stability of the biosensor were discussed. The applicability to blood analysis was also evaluated.  相似文献   

5.
This paper presents the amperometric biosensor that determines choline and cholinesterase activity using a screen printed graphite electrode. In order to detect H2O2 we have blanket modified the electrode material with manganese dioxide nanoparticles layer. Using layer-by-layer technique on the developed hydrogen peroxide sensitive electrode surface choline oxidase was incorporated into the interpolyelectrolyte nanofilm. Its ability to serve as a detector of choline in bulk analysis and cholinesterase assay was investigated. We examined the interferences from red-ox species and heavy metals in the blood and in the environmental sample matrixes. The sensor exhibited a linear increase of the amperometric signal at the concentration of choline ranging from 1.3 × 10−7 to 1.0 × 10−4 M, with a detection limit (evaluated as 3σ) of 130 nM and a sensitivity of 103 mA M−1 cm−2 under optimized potential applied (480 mV vs. Ag/AgCl). The biosensor retained its activity for more than 10 consecutive measurements and kept 75% of initial activity for three weeks of storage at 4 °C. The R.S.D. was determined as 1.9% for a choline concentration of 10−4 M (n = 10) with a typical response time of about 10 s. The developed choline biosensor was applied for butyrylcholinesterase assay showing a detection limit of 5 pM (3σ). We used the biosensor to develop the cholinesterase inhibitor assay. Detection limit for chlorpyrifos was estimated as 50 pM.  相似文献   

6.
A novel amperometric biosensor for the determination of catechol was developed accordingly to the electrochemical template procedure. The optimum fabricating conditions of the biosensor were studied. The resulting biosensor with the limit of less than 0.05 μM can be used for detection of catechol in the linear range of 2.5-140 μM. The maximum response current (Imax) and the Michaelis-Menten constant (km) are 3.08 μA and 77.52 μM, respectively. The activation energy (Ea) of the polyphenol oxidase (PPO) catalytic reaction is 25.56 kJ mol−1 in the B-R buffer. The stability of the PANI-CA biosensor fabricated with the electrochemical template process (retains 86% of the original activity after four months) is much higher than that fabricated with one-step and two-step processes (retains 75% of the original activity after four months). The effects of potential and pH on the response current of the biosensor are also described.  相似文献   

7.
A label-free DNA biosensor for hybridization detection of short DNA species related to the transgenic plants gene fragment of cauliflower mosaic virus (CaMV) 35S promoter was developed in this paper. The nanocomposite containing chitosan (CS) and mutiwalled carbon nanotubes (MWNTs) was first coated on a glassy carbon electrode. Then a highly reactive dialdehyde reagent of glutaraldehyde (GTD) was applied as an arm linker to covalently graft the 5′-amino modified probe DNA to the CS-MWNTs surface via the facile aldehyde-ammonia condensation reaction. The hybridization capacity of the developed biosensor was monitored with electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/4− as an indicating probe, and the experimental results showed that the biosensor had fast hybridization rate and low background interference. A wide dynamic detection range (1.0 × 10−13-5 × 10−10 M) and a low detection limit (8.5 × 10−14 M) were achieved for the complementary sequence. In addition, the hybridization specificity experiments showed that the sensing system can accurately discriminate complementary sequence from mismatch and noncomplementary sequences.  相似文献   

8.
We report on the electrodeposition of a 3-aminopropyltriethoxysilane-chitosan (APTES-CS) hybrid gel film for in situ immobilization of glucose oxidase (GOx) on an Au or platinized Au (Ptnano/Au) electrode for biosensing of glucose. Controllable electroreduction of p-benzoquinone is used to lift the electrode-surface pH for the GOx-APTES-CS codeposition, which was monitored by an electrochemical quartz crystal microbalance. The fabrication procedures of the biosensor and the parameters influencing the biosensing performance were optimized. The prepared porous GOx-APTES-CS/Ptnano/Au and GOx-APTES-CS/Au electrodes can be used to detect the enzymatically generated H2O2 at 0.5 and 0.7 V vs SCE, respectively. The enzyme electrodes exhibited linear responses to glucose concentration from 0.2 μM to 8.2 mM (R = 0.998, at Ptnano/Au substrate) and from 0.2 μM to 5.5 mM (R = 0.998, at Au substrate), with current sensitivities of 69.5 (Ptnano/Au) and 65 (Au) μA mM−1 cm−2, respectively, and a detection limit of 0.2 μM (S/N = 3) was achieved for each electrode. The response time was less than 5 (Ptnano/Au) or 8 (Au) s. It is striking that the enzyme electrodes remained their initial response sensitivity after storage for 5 (Au) and >6 (Ptnano/Au) months in 0.10 M PBS (pH 7.0) at 4 °C.  相似文献   

9.
An amperometric glucose biosensor based on a multilayer made by layer-by-layer assembly of single-walled carbon nanotubes modified with glucose oxidase (GOx-SWCNT conjugates) and redox polymer (PVI-Os) on a screen-printed carbon electrode (SPCE) surface was developed. The SPCE surface was functionalized with a cationic polymer by electrodeposition of the PVI-Os, followed by alternating immersions in anionic GOx-SWCNT conjugate solutions and cationic PVI-O solutions. The purpose is to build a multilayer structure which is further stabilized through the electrodeposition of PVI-Os on the multilayer film. The electrochemistry of the layer-by-layer assembly of the GOx-SWCNT conjugate/PVI-Os bilayer was followed by cyclic voltammetry. The resultant glucose biosensor provided stable and reproducible electrocatalytic responses to glucose, and the electrocatalytic current for glucose oxidation was enhanced with an increase in the number of bilayers. The glucose biosensor displayed a wide linear range from 0.5 to 8.0 mM, a high sensitivity of 32 μA mM−1 cm−2, and a response time of less than 5 s. The glucose biosensor proved to be promising amperometric detectors for the flow injection analysis of glucose.  相似文献   

10.
The magnetic core-shell Au-Fe3O4@SiO2 nanocomposite was prepared by layer-by-layer assembly technique and was used to fabricate a novel bienzyme glucose biosensor. Glucose oxidase (GOD) and horseradish peroxidase (HRP) were simply mixed with Au-Fe3O4@SiO2 nanocomposite and cross-linked on the ITO magnetism-electrode with nafion (Nf) and glutaraldehyde (GA). The modified electrode was designated as Nf-GOD-HRP/Au-Fe3O4@SiO2/ITO. The effects of some experimental variables such as the pH of supporting electrolyte, enzyme loading, the concentration of the mediator methylene blue (MB) and the applied potential were investigated. The electrochemical behavior of the biosensor was studied using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and chronoamperometry. Under the optimized conditions, the biosensor showed a wide dynamic range for the detection of glucose with linear ranges of 0.05-1.0 mM and 1.0-8.0 mM, and the detection limit was estimated as 0.01 mM at a signal-to-noise ratio of 3. The biosensor exhibited a rapid response, good stability and anti-interference ability. Furthermore, the biosensor was successfully applied to detect glucose in human serum samples, showing acceptable accuracy with the clinical method.  相似文献   

11.
We developed a 2 × 5 model quartz crystal microbalance (QCM) DNA biosensor array for detection of five bacteria, which based on hybridization analysis of bacterial 16S-23S rDNA internal transcribed spacer (ITS) region. A pair of universal primers was designed for PCR amplification of the ITSs. The PCR products were analyzed by the biosensor. We used gold nanoparticles to amplify the frequency shift signals. Fifty clinical samples were detected by both the biosensor and conventional bacteria culture method. We found a linear quantitative relationship between frequency shift and logarithmic concentration of synthesized oligonucleotides or bacteria cells. The measurable concentration ranged from 10−12 to 10−8 M for synthesized oligonucleotides and 1.5 × 102 to 1.5 × 108 CFU/mL for bacteria. The 10−12 M of synthesized oligonucleotides or 1.5 × 102 CFU/mL of Pseudomonas aeruginosa could be detected by the biosensor system. The detection could be completed within 5 h including the PCR amplification procedure. Compared with bacteria culture method, the detection sensitivity and specificity of the biosensor system were 94.12% and 90.91%, respectively. There was no significant difference between these two methods (P = 0.625 > 0.05). The biosensor system provides a rapid and sensitive method for parallelized and quantitative analysis of multiple pathogenic bacteria in clinical diagnosis.  相似文献   

12.
An electrochemical biosensor for determination of hydrogen peroxide (H2O2) has been developed by the hybrid film of poly(methylene blue) and FAD (PMB/FAD). The PMB/FAD hybrid film was performed in PBS (pH 7) containing methylene blue and FAD by cyclic voltammetry. Repeatedly scanning potential range of −0.6-1.1 V, FAD was immobilized on the electrode surface by electrostatic interaction while methylene blue was electropolymerized on electrode surface. This modified electrode was found surface confined and pH dependence. It showed good electrocatalytic reduction for H2O2, KBrO3, KIO3, and NaClO as well as electrocatalytic oxidation for NADH. At an applied potential of −0.45 V vs. Ag/AgCl, the sensor showed a rapid and linear response to H2O2 over the range from 0.1 μM to 960 μM, with a detection limit of 0.1 μM and a significant sensitivity of 1109 μA mM−1 cm−2 (S/N = 3). It presented excellent stability at room temperature, with a variation of response current less than 5% over 30 days.  相似文献   

13.
A novel method for detecting human IgG is reported, which is based on Au/Ag alloy nanocomposites for amplifying surface plasmon resonance response. Au/Ag alloy nanocomposites were characterized in detail by transmission electron microscopy (TEM), UV-vis absorption spectroscopy and X-ray photoelectron spectroscopy (XPS). Covalent immobilization of about 24 nm diameter of Au/Ag alloy nanocomposites on the Au film results in a large shift in resonance wavelength, which is due to the increase of the thickness of the sensing membrane, high dielectric constant of Au/Ag nanoparticles, and electromagnetic coupling between Au/Ag alloy nanocomposites and Au film. The SPR biosensor based on Au/Ag alloy nanocomposites exhibits a satisfactory response for human IgG in the concentration range of 0.15-40.00 μg mL−1. While the biosensor based on Au nanoparticles shows a response in the concentration range of 0.30-20.00 μg mL−1 and the biosensor based on Au film shows a response for human IgG in the concentration range of 1.25-20.00 μg mL−1.  相似文献   

14.
15.
A simple and new way to immobilize glucose dehydrogenase (GDH) enzyme onto nile blue (NB) covalently assembled on the surface of functionalized single-walled carbon nanotubes (f-SWCNTs) modified glassy carbon (GC) electrode (GDH/NB/f-SWCNTs/GC electrode) was described. The GDH/NB/f-SWCNTs/GC electrode possesses promising characteristics as glucose sensor; a wide linear dynamic range of 100-1700 μM, low detection limit of 0.3 μM, fast response time (1-2 s), high sensitivity (14 μA cm−2 mM−1), anti-interference ability and anti-fouling. Moreover, the performance of the GDH/NB/f-SWCNTs/GC bioanode was successfully tested in a glucose/O2 biofuel cell. The maximum power density delivered by the assembled glucose/O2 biofuel cell could reach 32.0 μW cm−2 at a cell voltage of 0.35 V with 40 mM glucose. The present procedure can be applied for preparing a potential platform to immobilize different enzymes for various bioelectrochemical applications.  相似文献   

16.
An electrochemical sensor based on graphene-polyaniline (GR-PANI) nanocomposite for voltammetric determination of 4-aminophenol (4-AP) is presented. The electrochemical behavior of 4-AP at the GR-PANI composite film modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry. 4-AP exhibits enhanced voltammetric response at GR-PANI modified GCE. This electrochemical sensor shows a favorable analytical performance for 4-AP detection with a detection limit of 6.5 × 10−8 M and high sensitivity of 604.2 μA mM−1. Moreover, 4-AP and paracetamol can be detected simultaneously without interference of each other in a large dynamic range.  相似文献   

17.
Neurotoxic organophosphorus (OP) compounds are commonly used as chemical warfare agents and pesticides. Due to their high toxicity, rapid and sensitive field detection of these compounds has been an ongoing topic of interest. Biosensors made with organophosphate hydrolase enzyme (OPH) are generally designed to either amperometrically detect an electroactive leaving group produced following enzymatic cleavage, or to potenitometrically detect the pH change that occurs during cleavage. Since OPs are more likely to have phenolic leaving groups as compared to electroactive leaving groups, we have developed a new amperometric dual enzyme electrochemical assay that enables the detection of a broad class of OP compounds using the OPH enzyme combined with horseradish peroxidase (HRP). The assay has been applied to the detection of dichlofenthion, which does not have an electroactive leaving group and is not a commonly investigated OPH substrate. Using reverse phase HPLC, we have determined the Michaelis-Menten kinetic parameters of an engineered OPH enzyme to be KM = 0.11 ± 0.02 mM and kcat = 0.046 ± 0.003 s−1 with dichlofenthion as the substrate. Detection of the phenolic leaving group from the OPH enzyme reaction using the HRP electrode is carried out at −50 mV vs. Ag/AgCl where the noise and background are low and interferences are negligible. After optimization of the solution pH, the dual enzyme biosensor was found to have a limit of detection (LOD) of 24 μM (7.6 ppm), and a sensitivity of 0.095 ± 0.024 nA/μM for dichlorofenthion. By detecting the phenolic leaving groups from the OP targets using the HRP electrode, biosensors made using this new platform have the potential to detect a broad range of important OP compounds.  相似文献   

18.
The electrochemical monitoring of glucose consumption is relevant for cell biology studies because of its wide detection range, high sensitivity and easy implementation. Whereas the glucose consumption and cell growth rate can be tightly correlated, they should also be cell population density dependent. In this work, we fabricated high sensitive enzyme electrodes for accurate monitoring of glucose consumption of cells in different growth stages. The performance of the fabricated device was firstly evaluated by cyclic voltammetry (CV) with p-benzoquinone (PBQ) as redox mediator, showing a linear response over a wide detection range (0.3-60 mM), a high sensitivity (1.61 ± 0.10 μA mM−1 mm−2 (n = 5)) and a low detection limit (80 μM). Then, daily glucose consumptions of NIH 3T3 cells in 24-well plates were determined for a period of 7 days. The results could be compared to the cell population growth curve, showing a close correlation but different behavior. We found that the increase of the glucose consumption took place prior the cell number increase but the glucose consumption per cell decreases linearly in the exponential growth stage of cells.  相似文献   

19.
A promising material of poly(lactic-co-glycolic acid) (PLGA) and, room temperature ionic liquid (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4) was firstly used as an immobilization matrix to entrap proteins and its bioelectrochemical properties were studied. Direct electrochemistry and electrocatalytic behaviors of hemoglobin (Hb) entrapped in the PLGA/ILs composite film on the surface of glass carbon electrode were investigated. UV-vis spectroscopy, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the composite film. The obtained results demonstrated that the Hb molecule in the film kept its native structure and showed its good electrochemical behavior. A pair of well-defined redox peaks of Hb was obtained at the Hb/PLGA/ILs composite film-modified GC electrode through direct electron transfer between the protein and the underlying electrode. The proposed biosensor showed good reproducibility and high sensitivity to H2O2 with the detection limit of 2.37 × 10−7 M (S/N = 3). In the range of 5.0 × 10−6 to 8.05 × 10−3 M, the catalytic reduction current of H2O2 was proportional to its concentration. The apparent Michaelis-Menten constant of Hb in the PLGA/ILs composite film was estimated to be 0.069 mM, showing its high affinity.  相似文献   

20.
An electrochemical biosensor was optimised for the analysis of volatile alcohols directly from the gas phase without prior absorption or pre-concentration. The sensor is based on the alcohol oxidase (Pichia pastoris) catalyzed conversion of ethanol and the amperometric detection of the generated hydrogen peroxide. Key part of the three-electrode set-up was a gas-diffusion working electrode (potential: +600 mV vs. Ag/AgCl) that consisted of a porous Teflon membrane coated with a thin platinum layer. Headspace samples were analysed for alcohols and used to derive alcohol concentrations in the liquid phase. The biosensor had a sensitivity of 3.43 μA/mM for ethanol, a response time of 69 s, a linear dynamic range of 0.10-30 mM, a theoretical detection limit (3 < S/N) of 9.9 μM, and a stability of 86% during continuous operation (18 h @ 1 mM ethanol). Using one sensor on three consecutive days, the mean coefficient of variation was 1.3% (three measurements each day @ 10 mM ethanol). Alcohol contents of three apple juices determined with the biosensor were in the range 0.30 g/l-0.67 g/l (equivalent to 6.51 mM-14.5 mM). However, ethanol contents determined by high pressure liquid chromatography coupled to refractive index detection (HPLC-RI) and by a commercial enzyme test kit based on alcohol dehydrogenase ranged from 0.12 g/l to 0.38 g/l (equivalent to 2.60 mM-8.25 mM). Both indicate that the biosensor detected alcohols other than ethanol in the apple juices. HPLC-RI coupled to the biosensor in a flow-through configuration demonstrated that the biosensor detected methanol concomitant to ethanol. Thus, the biosensor could perform a qualitative analysis of the total content of volatile alcohols in apple juices by analysing the gas phase above the sample. This offers the additional advantage that possible, non-volatile interfering substances in the liquid sample cannot impair the measurement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号