首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Pure diamond-like carbon (DLC) thin films and boron-doped DLC thin films have been deposited on silicon substrates using femtosecond pulsed laser. The amorphous carbon materials (DLC), have been deposited at room temperature by ablating graphite targets with an amplified Ti:sapphire laser of 800 nm wavelength and a pulse duration of 150 fs in high vacuum conditions. Doping with boron has been performed by ablating alternatively graphite and boron targets.In this study, the DLC films were used as working electrodes for the electrochemical detection of trace heavy metals namely, Cd2+, Pb2+, Ni2+ and Hg2+, by using square wave anodic stripping voltammetry (SWASV) technique. Four metals were detected at −1.3 V deposition potential, and 90 s deposition time. The DLC films have been characterized by multiwavelength Raman spectrometry and high resolution scanning electron microscopy. The effect of the boron doping on the electrochemical behavior has been shown. The a-C:B 8%/Si3N4 electrode gives the more sensitive detection. The four metals are detected simultaneously with a detection limit of 1 μg/L or 2 μg/L and a dynamic range from 1 or 2 to 25 μg/L for every metal, as presented in third table of this article. The different sensitivities obtained are 6.2, 20.0, 1.2 and 6.6 μA/ppb or μA μg−1 L for Cd2+, Pb2+, Ni2+ and Hg2+, respectively.  相似文献   

2.
A new dopamine-derivative, i.e. N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide (N-DHPB), was synthesized and its application was investigated for the simultaneous determination of N-acetylcysteine (NAC) and acetaminophen (AC) using modified multiwall carbon nanotubes paste electrode. This modified electrode exhibited a potent and persistent electron mediating behavior followed by well separated oxidation peaks of NAC and AC. The peaks current of differential pulse voltammograms of NAC and AC increased linearly with their concentration in the ranges of 0.5-200 μmol L−1 NAC and 15.0-270 μmol L−1 AC. The detection limits for NAC and AC were 0.2 μmol L−1 and 10.0 μmol L−1, respectively. The relative standard deviation for seven successive assays of 1.0 and 30.0 μmol L−1 NAC and AC were 1.7% and 2.2%, respectively. The proposed sensor was successfully applied for the determination of NAC in human urine, tablet, and serum samples.  相似文献   

3.
A highly sensitive electrochemical sensor for the determination of acetaminophen at the multiwalled carbon nanotube-alumina-coated silica (MWCNT-ACS) nanocomposite modified glassy carbon electrode is reported. The morphology of the MWCNT-ACS nanocomposite was characterized by field emission scanning electron microscopy. The electrocatalytic properties of the MWCNT-ACS nanocomposite modified glassy carbon electrode were characterized by cyclic voltammetry and square-wave voltammetry in the presence of acetaminophen. The MWCNT-ACS nanocomposite modified glassy carbon electrode exhibited the abilities to raise the current response and to decrease the electrooxidation potential. In cyclic voltammetric responses, the oxidation peak current of acetaminophen obtained at the MWCNT-ACS modified glassy carbon electrode was 100 times greater than that of bare glassy carbon electrode. The MWCNT-ACS nanocomposite modified glassy carbon electrode for the determination of acetaminophen displayed a sensitivity of 376.5 A M−1 cm−2 and a detection limit of 0.05 μM using square-wave voltammetry. The analytical applicability of the developed method was achieved by analyzing the content of acetaminophen in five commercial drugs without pretreatment.  相似文献   

4.
A novel sensor was developed for simultaneous detection of Pb, Cd and Zn, based on the differential pulse anodic stripping response at a bismuth/poly(p-aminobenzene sulfonic acid) (Bi/poly(p-ABSA)) film electrode. This electrode was generated in situ by depositing simultaneously bismuth and the metals by reduction at −1.40 V on the poly(p-ABSA) modified electrode. Compared with the bismuth film electrode, the Bi/poly(p-ABSA) film electrode can yield a larger stripping signal for Pb, Cd and Zn. Under the optimum conditions, a linear response was observed for Cd and Zn in the range from 1.00 to 110.00 μg L−1 and for Pb in the range from 1.00 to 130.00 μg L−1. The detection limits of Pb(II), Cd(II) and Zn(II) were 0.80, 0.63 and 0.62 μg L−1, respectively. Finally this sensor had been applied to the simultaneous determination of Pb(II), Cd(II) and Zn(II) in river water samples and the results were quite corresponding to the value obtained by atomic absorption spectrometry.  相似文献   

5.
An electrochemical biosensor for determination of hydrogen peroxide (H2O2) has been developed by the hybrid film of poly(methylene blue) and FAD (PMB/FAD). The PMB/FAD hybrid film was performed in PBS (pH 7) containing methylene blue and FAD by cyclic voltammetry. Repeatedly scanning potential range of −0.6-1.1 V, FAD was immobilized on the electrode surface by electrostatic interaction while methylene blue was electropolymerized on electrode surface. This modified electrode was found surface confined and pH dependence. It showed good electrocatalytic reduction for H2O2, KBrO3, KIO3, and NaClO as well as electrocatalytic oxidation for NADH. At an applied potential of −0.45 V vs. Ag/AgCl, the sensor showed a rapid and linear response to H2O2 over the range from 0.1 μM to 960 μM, with a detection limit of 0.1 μM and a significant sensitivity of 1109 μA mM−1 cm−2 (S/N = 3). It presented excellent stability at room temperature, with a variation of response current less than 5% over 30 days.  相似文献   

6.
An amperometric glucose sensor based on Pd-Ni/SiNW electrode has been investigated. The silicon nanowire (SiNW) electrodes were first fabricated by chemical etching, and then nickel and palladium particles were deposited onto the surfaces of SiNWs via electroless co-plating technique followed by annealing in nitrogen atmosphere at 350 °C for 300 s. The morphology of Pd-Ni/SiNW electrode was characterized by scanning electron microscope (SEM) and X-ray diffraction (XRD). The sensor performance was characterized by cyclic voltammetry (CV) and fixed potential amperometry techniques. In 0.1 M KOH alkaline medium with different glucose concentrations, the sensor shows an excellent sensitivity of 190.72 μA mM−1 cm−2 with the detection limit (S/N ratio = 3) of 2.88 μM. And it also exhibits superior anti-interference properties to the species including ascorbic acid (AA), uric acid (UA) and 4-acetamidophenol (AP). All results demonstrate that this Pd-Ni/SiNW electrode is a candidate with great potential for glucose detection.  相似文献   

7.
The direct electrochemistry of house fly cytochrome P4506A1 (CYP6A1) confined in dioctadecyl dimethyl ammonium bromide (DDAB) film was achieved. The immobilized CYP6A1 displayed a pair of redox peaks with a formal potential of −0.36 mV in pH 7.0 O2-free phosphate buffers at scan rate of 1 V s−1 and the direct electron transfer of CYP6A1 was characterized by voltammetry. The CYP6A1 in the DDAB film retained its bioactivity and could catalyze the reduction of dissolved oxygen. Upon addition of its substrate aldrin or heptachlor to the air-saturated solution, the reduction peak current of dissolved oxygen increased, which indicates the catalytic behavior of CYP6A1 to its substrates. By amperometry a calibration linear range was obtained to be 9.08 × 10−6-4.54 × 10−5 mol L−1 with a sensitivity of 80 μA mM−1 for aldrin or 8.91 × 10−6-4.46 × 10−5 mol L−1 with a sensitivity of 66 μA mM−1 for heptachlor. The apparent Michaelis-Menten constant for the electrocatalytic activity of CYP6A1 was found to be 7.468 × 10−5 mol L−1 for aldrin and 4.316 × 10−5 mol L−1 for heptachlor. The bioelectrocatalytic products were analysed using gas chromatography (GC) and electron ionization-mass spectrometry (EI-MS). The results confirmed that epoxidation was the main pathways of CYP6A1-mediated organochlorine pesticides oxidation.  相似文献   

8.
4-Nonylphenol (4-NP) was reported to affect the health of wildlife and humans through altering endocrine function. A novel electrochemical sensor for sensitive and fast determination of 4-NP was developed. Titanium oxide (TiO2) nanoparticles and gold nanoparticles (AuNPs) were introduced for the enhancement of electron conduction and sensitivity. 4-NP-imprinted functionalized AuNPs composites with specific binding sites for 4-NP was modified on electrode. The resulting electrodes were characterized by cyclic voltammetry (CV). Rebinding experiments were carried out to determine the specific binding capacity and selective recognition. The linear range was over the range from 4.80 × 10−4 to 9.50 × 10−7 mol L−1, with the detection limit of 3.20 × 10−7 mol L−1 (S/N = 3). The sensor was successfully employed to detect 4-NP in real samples.  相似文献   

9.
Monoclonal antibodies (MAb) have been commonly applied to measure LDL in vivo and to characterize modifications of the lipids and apoprotein of the LDL particles. The electronegative low density lipoprotein (LDL) has an apolipoprotein B-100 modified at oxidized events in vivo. In this work, a novel LDL electrochemical biosensor was developed by adsorption of anti-LDL MAb on an (polyvinyl formal)-gold nanoparticles (PVF-AuNPs)-modified gold electrode. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to characterize the recognition of LDL. The interaction between MAb-LDL leads to a blockage in the electron transfer of the [Fe(CN)6]4−/K4[Fe(CN)6]3− redox couple, which may could result in high change in the electron transfer resistance (RCT) and decrease in the amperometric responses in CV analysis. The compact antibody-antigen complex introduces the insulating layer on the assembled surface, which increases the diameter of the semicircle, resulting in a high RCT, and the charge transferring rate constant κ0 decreases from 18.2 × 10−6 m/s to 4.6 × 10−6 m/s. Our results suggest that the interaction between MAb and lipoprotein can be quantitatively assessed by the modified electrode. The PVF-AuNPs-MAb system exhibited a sensitive response to LDL, which could be used as a biosensor to quantify plasmatic levels of LDL.  相似文献   

10.
An electrochemical sensor based on graphene-polyaniline (GR-PANI) nanocomposite for voltammetric determination of 4-aminophenol (4-AP) is presented. The electrochemical behavior of 4-AP at the GR-PANI composite film modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry. 4-AP exhibits enhanced voltammetric response at GR-PANI modified GCE. This electrochemical sensor shows a favorable analytical performance for 4-AP detection with a detection limit of 6.5 × 10−8 M and high sensitivity of 604.2 μA mM−1. Moreover, 4-AP and paracetamol can be detected simultaneously without interference of each other in a large dynamic range.  相似文献   

11.
A biosensor based on bovine serum albumin (BSA) and poly-o-phenylenediamine (PoPD)/carbon-coated nickel (C-Ni) nanobiocomposite film modified electrode has been developed to study the interaction of BSA with papaverine (PAP). The well-dispersed C-Ni nanoparticles were dripped onto the glassy carbon electrode (GCE) surface firstly, and PoPD films were subsequently electropolymerized by cyclic voltammetry (CV) to prepare PoPD/C-Ni/GCE. Finally, the BSA was easily immobilized on the PoPD films via electrostatic adsorption. The morphology and the electrochemical properties of the fabricated composite electrodes were examined by scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS), respectively. The interaction of PAP with BSA was monitored by differential pulse voltammetry (DPV), using PoPD as the electrochemical indicator. The binding constant (K), obtained by DPV, was 1.7 × 104 L/mol, which was consistent with the fluorescence analysis. This constructed biosensor also exhibited a fine linear correlation with PAP concentration range of 2.5 × 10−9-4.5 × 10−5 mol/L and a detection limit of 8.3 × 10−10 mol/L was achieved by DPV.  相似文献   

12.
A novel label-free electrochemical immunosensor for sensitive detection of kanamycin based on water-soluble graphene sheet (WGS)/prussian blue-chitosan (PB-CTS)/nanoporous gold (NPG) composited film has been reported. PB was selected as an electron transfer mediator, and was modified onto the electrode together with WGS through electrostatic adsorption. Then NPG was immobilized onto the as-prepared film for biomolecules anchoring. The electroactivity of PB was greatly enhanced in the presence of WGS and NPG. It could mainly be ascribed to the fact that the good conductivity of WGS and NPG promoted electron transfer and enhanced the sensitivity. kanamycin antibody, as a model, was immobilized onto the composite film for the detection of kanamycin. Under optimum conditions, the amperometric signal of PB decreased linearly with kanamycin concentration (0.02-14 ng mL−1), a linear calibration plot (y = 1.3817 + 4.7544x, r = 0.9993), resulting in a low limit of detection (6.31 pg mL−1). The novel immunosensor for the detection of kanamycin in real sample with satisfactory results has been proved. In addition, this method would be easily adapted for the detection of other residual antibiotics in animal derived foods.  相似文献   

13.
The electrocatalysis of hydrazine oxidation by poly-ethylenedioxy pyrrole (PEDOP)-coated MWCNTs-palladium nanoparticles [PEDOP/MWCNTs-Pd] was investigated as an electrochemical sensor on the surface of glassy carbon electrode (GCE) in aqueous medium. Electrochemical oxidation of hydrazine in phosphate buffer (pH 7.4) was performed using cyclic voltammetry (CV) and chronoamperometry (CA) methods. Using the proposed electrode, the catalytic oxidation peak current of hydrazine was high and the overpotential of its oxidation decreased. Based on the obtained results, a mechanism for electrooxidation of hydrazine at [PEDOP/MWCNTs-Pd/GCE] demonstrated an irreversible diffusion-controlled electrode process and a four-electron transfer involved in the overall reaction. The experimental results showed that the mediated oxidation peak currents of the hydrazine were linearly dependent on the concentration of hydrazine in the range of 1.0 × 10−7 to 5.0 × 10−3 M. The detection limit (S/N = 3) was found to be 4 × 10−8 M with a fast response time of 10 s.  相似文献   

14.
A promising material of poly(lactic-co-glycolic acid) (PLGA) and, room temperature ionic liquid (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4) was firstly used as an immobilization matrix to entrap proteins and its bioelectrochemical properties were studied. Direct electrochemistry and electrocatalytic behaviors of hemoglobin (Hb) entrapped in the PLGA/ILs composite film on the surface of glass carbon electrode were investigated. UV-vis spectroscopy, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the composite film. The obtained results demonstrated that the Hb molecule in the film kept its native structure and showed its good electrochemical behavior. A pair of well-defined redox peaks of Hb was obtained at the Hb/PLGA/ILs composite film-modified GC electrode through direct electron transfer between the protein and the underlying electrode. The proposed biosensor showed good reproducibility and high sensitivity to H2O2 with the detection limit of 2.37 × 10−7 M (S/N = 3). In the range of 5.0 × 10−6 to 8.05 × 10−3 M, the catalytic reduction current of H2O2 was proportional to its concentration. The apparent Michaelis-Menten constant of Hb in the PLGA/ILs composite film was estimated to be 0.069 mM, showing its high affinity.  相似文献   

15.
An amperometric oxalate biosensor using nanohybrid film of multi-walled carbon nanotubes (MWCNTs) and gold colloidal nanoparticles (GNPs) via carbodiimide chemistry by forming amide linkages between carboxylic acid groups on the CNTs and amine residues of cysteamine self-assembled monolayer (SAM) has been prepared. The c-MWCNTs were immobilized on the gold (Au) electrode and characterized by FTIR. The morphologies of the c-MWCNT/Au and GNPs/MWCNT/Au electrodes were investigated by scanning electron microscopy (SEM) and the electrochemical performance of the Au, c-MWCNT/Au and GNPs/c-MWCNT/Au electrodes were also studied amperometrically. The Cl and NO3 insensitive oxalate oxidase from grain sorghum was finally immobilized on this electrode. The influence of pH, temperature and oxalate concentration on electrode activity was studied. The electrode showed optimum response within 7 s. The electrocatalytic response showed a linear dependence on the oxalic acid concentration ranging from 1 to 800 μM with a detection limit of 1 μM. The Km value for the oxalic acid sensor was 444.44 μM. The enzyme electrode retained 30% of its initial activity after 5 months, when stored at 4 °C. The electrode was employed for measurement of oxalic acid in serum, urine and foodstuffs.  相似文献   

16.
The graphite oxide (GO) was prepared via the chemical oxidation of natural graphite powder, and then used to modify the surface of glassy carbon electrode (GCE). The electrochemical behavior of acetaminophen was examined. In 0.01 mol L−1 HCl, an irreversible oxidation peak is observed for acetaminophen, and the peak current remarkably increases at the GO film-modified GCE. The influences of supporting electrolyte, amount of GO suspension, accumulation potential and time were studied on the oxidation peak current of acetaminophen. As a result, a new electrochemical method was developed for the detection of acetaminophen. The linear range is from 25 μg L−1 to 4 mg L−1, and the limit of detection is 6 μg L−1 based on three signal-noise ratio. Finally, it was successfully used to detect acetaminophen in tablets.  相似文献   

17.
Herein we report the photoelectrocatalytic regeneration of NADH at poly(4,4′-diaminodiphenyl sulfone)/nano TiO2 (PDDS/TiO2) composite modified indium tin oxide (ITO) electrode. The PDDS film growth was confirmed through in situ electrochemical quartz crystal microbalance (EQCM) studies. The prepared PDDS/TiO2 composite was characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM) and X-ray diffraction (XRD) studies. SEM and AFM results confirmed that TiO2 nanoparticles size is between 130 and 180 nm. XRD results showed that TiO2 nanoparticles are crystalline and belong to anatase phase. Electrochemical impedance spectroscopy (EIS) and light induced EIS results substantiate a rapid electron transfer process at PDDS/TiO2 composite surface. Cyclic voltammetry (CV) results demonstrated that composite film showed excellent response to the photoelectrocatalytic regeneration of NADH. The photoelectrocatalytic oxidation of NADH at composite film surface irradiated for 5 min (optimized irradiation time) produced a notable enhancement in anodic peak current and it was 18-fold higher than that of PDDS film and several folds higher than that of TiO2 and bare ITO electrodes. Further, composite film showed higher sensitivity of 124.1 μA μM−1 for NADH. From Square wave voltammetry (SWV) results, sensitivity of the irradiated composite film was obtained as 0.252 μA nM−1 of NADH. The linear concentration range was between 23 and 39 nM NADH respectively. Further, the composite film exhibits good selectivity towards NADH and no significant interference effect was observed even when 200-fold excess of ascorbic acid (AA), dopamine (DA) and uric acid (UA) coexist in the same supporting electrolyte solution.  相似文献   

18.
In this work, an electrochemical sensor based on ordered mesoporous carbon (OMC) for the amperometric detection of isoniazid was developed. OMC was dispersed in a solution of Nafion, and the suspension was modified onto the surface of glassy carbon (GC) electrode. Cyclic voltammetry and amperometry were used to investigate the electrochemical behaviors of isoniazid on Nafion-OMC modified electrode (Nafion-OMC/GC). The results indicate that OMC can facilitate the electrochemical oxidation of isoniazid with a great decrease of overpotential in pH 7.0 phosphate buffer solution. The proposed biosensor provides excellent performance towards the determination of isoniazid with a high sensitivity of 0.031 μA/μM, a low detection limit of 8.4 × 10−8 M and wide linear range from 1.0 × 10−7 M to 3.7 × 10−4 M at +0.20 V vs. Ag/AgCl. The method was successfully applied to the determination of isoniazid tablets with satisfying results. All the results suggest that Nafion-OMC/GC electrode is a potential candidate for a stable and efficient electrochemical sensor to detect isoniazid.  相似文献   

19.
This paper presents a reusable polymer lab chip sensor for continuous and on-site heavy metal monitoring in nature. In particular, detection of lead (Pb(II)), which is the most common heavy metal pollutant, has been performed using the proposed lab chip sensor. The miniaturized lab chip sensor consists of a microfabricated silver working electrode that replaces the conventional mercury and bismuth electrodes, an integrated silver counter and quasi-reference electrode, and microfluidic channels. The proposed sensor targets on-site environmental monitoring in a continuous fashion without disturbing or contaminating the sensing environment when it is reused. The reusability of the miniaturized lab chip sensor was characterized through forty-three consecutive measurements in non-deoxygenating standard solutions inside the microchannels using square-wave anodic stripping voltammetry (SWASV). With only 13.5 μL of sample volume the sensor chip showed a correlation coefficient of 0.998 for the Pb(II) concentration range of 1-1000 ppb with the limit of detection of 0.55 ppb at 300 s deposition time. The peak potentials during the forty-three consecutive SWASV measurements showed a relative standard deviation of 1.0%, with a standard deviation of 0.005 V. The high repeatability and linearity of the sensor over the large, three orders of magnitude, dynamic range of 1-1000 ppb showed that the developed sensor chip can be reused for a variety of on-site measurements such as for soil pore water or groundwater, using only micro-volumes.  相似文献   

20.
The development of a preconcentrating sensor based on 6-O-palmitoyl-l-ascorbic acid (PAA)-modified graphite (GRA) electrodes for the determination of uranium is described. PAA, a water insoluble compound of ascorbic acid, was immobilized onto the surface of the GRA electrodes through physical adsorption from acetone solutions. Uranium was accumulated by heterogeneous complexation (10 min, in 0.1 M H3BO3, pH 4.3) and then, it was reduced by means of a differential pulse voltammetric scan in 0.1 M H3BO3, pH 3.4. Alternatively, the performance of both preconcentration and voltammetric steps in a single run, at 0.1 M H3BO3, pH 3.65, was also examined; however, in this case the observed current signals were lower by 30%. The experimental variables were investigated and under the selected conditions, a linear calibration curve in the range 2.7-67.5 μg L−1 U(VI) was constructed (r2 = 0.9981). The 3σ limit of detection and the relative standard deviation of the method were 1.8 μg L−1 U(VI) and 8% (n = 5, 20 μg L−1 U(VI), preconcentration time 10 min), respectively. By increasing the preconcentration time to 30 min, a limit of detection as low as 0.26 μg L−1 U(VI) can be achieved. The effect of potential interferences was also examined. The accuracy of the method was established by recovery studies in inoculated tap and lake water samples. A simple and fast procedure based on filtering of the sample through a C-18 microcolumn was successfully used to remove the organic matter from the lake water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号