首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The performance of CO2 refrigeration systems strongly depends on the operating conditions. The specific characteristics of low critical temperature and high operating pressure limit its applications and imply the implementation of different control strategies. This study compares the performance of different CO2 system solutions for supermarket refrigeration with R404A system. Some possible modifications and improvements on the CO2 system have been investigated. The COP of the investigated CO2 system solution can be improved by about 3–7% along the ambient temperature range of 10–40 °C. The annual energy consumption calculations in three different climates; cold, moderate and hot, show that the centralized trans-critical CO2 system is good solution for cold climates whereas the NH3–CO2 cascade system has the lowest energy consumption in hot climates. Both systems proved to be good alternatives to R404A DX system for supermarket refrigeration.  相似文献   

2.
A cold generation system featuring a Rankine cycle powered refrigeration cycle actuated by a supersonic ejector was theoretically investigated in view of the thermo-fluid-dynamic optimization of the working fluid characteristics.

The ejector model was validated against well established performance charts relating to water. A reference system was considered in which a Rankine cycle at moderate top temperature delivers its expansion power by means of an ideal turbine to an ideal compressor of a refrigeration cycle. Two main optimizing variables were ascertained: the fluid critical temperature and the complexity of the fluid molecule. The best performance of such reference cycle is around 80% of that of an ideal fully reversible, Carnot cycle based, system (COP of 2.0 for tE,PC = 150 °C, tE,RC = 5 °C, and tC = 35 °C). As easily predictable the ejector compression introduces severe losses mainly due to the normal shock and the mixing of the motive and of the driven fluid. Overall COP for the above quoted temperatures decreases from 2.0 (reference cycle) to 0.4–0.7. The optimization of the working fluid showed that comparatively low critical temperatures are favoured and that a fluid complexity similar to that of CH5N or CH2Cl2 gives the best performance. A detailed losses analysis explains this behaviour. In particular at low reduced temperatures the theoretical gain related to the better shape in the T–S plane of both the power and the refrigeration cycle is more than offset by the higher ejector losses due to the stronger normal shock needed to cope with an increased pressure ratio.

Notwithstanding an extensive fluid screening we did not succeed in finding a fluid that could be considered optimum from all points of view including ambient and safety issues. However, a number of traditional (non-zero ODP) chloro-fluoro-carbons and of new (zero ODP) refrigerants were found that yield, on the whole, a satisfactory performance.

Provided calculated COP will be confirmed by experimental testing, ejector powered refrigerators could compete with absorption systems in many applications.  相似文献   


3.
Capillary tubes have been used in refrigeration systems for many years, but not with a transcritical CO2 system. In this article, the effects of capillary tubes in a transcritical CO2 refrigeration system have been investigated experimentally and theoretically. Different types of capillary tubes with different lengths (0.5–4 m) and diameters (1–2 mm) have been tested. The result of this work is a static model, which is used in the further work to make a simulation model (static) of a complete refrigeration system. The model is based on Friedel's and Colebrook's pressure drop correlations.

The behaviour of an adiabatic capillary tube in a refrigeration cycle has been investigated theoretically. The conclusion is that the COP of a system with capillary tubes generally is better than when a fixed high pressure is used, but not as good as when variable optimal high pressure is used. Capillary tubes are especially interesting in applications where the evaporation pressure is constant and the temperature out of the gas cooler varies no more than ±10 K from the design condition. The reduction in COP is more significant at low temperatures out of the gas cooler.  相似文献   


4.
This paper is an answer to the need of finding the optimal solution for the throttling system in refrigerating machines using CO2 as working fluid; such a solution must combine reliability, low installation cost and high energy efficiency. To this purpose, different expansion systems are compared by means of a simulation programme, including a new one, operating with a differential valve, a liquid receiver and a thermostatic valve. The typical compression refrigerating cycle performed by CO2 involves transcritical operations and therefore the upper pressure needs to be adjusted to the optimal value, that, unlike the traditional cycle, is not determined by heat transfer. The innovative system here proposed shows an intrinsic self-adjusting capability that leads to COP values quite close to the maximum ones when a fixed suitable value of the differential pressure is chosen, even if the temperature of the secondary fluid varies to a large extent.  相似文献   

5.
In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.  相似文献   

6.
The aim of this paper is to investigate, both experimentally and theoretically, the potential of improving the cycle efficiency through two stage compression with intermediate cooling, at operating conditions typical of air conditioning. The experimental set-up consists of two closed loop air circuits acting as heat sink and heat source for gas-cooler and evaporator, respectively. The tested refrigerating circuit includes two tube-and-fin heat exchangers as gas-cooler and evaporator, a back-pressure valve as throttling device and a double-stage semi-hermetic compound, two-piston, reciprocating compressor equipped with oil separator and intercooler. A full set of thermocouples, pressure transducers and flow-meters allows measurement of all the main parameters of the CO2 cycle, enabling to perform heat balance both air and refrigerant side. Tests were run at fixed evaporation pressure, evaporator outlet superheating and gas-cooler outlet temperature, varying the gas-cooler outlet pressure in the range 8–11 MPa. The optimal gas-cooler pressure for this application as well as the effect of the intercooler efficiency on the cycle performance were investigated.

A FORTRAN code for the simulation of an improved two-stage cycle was validated against the experimental results; a theoretical analysis performed with this code is proposed for optimisation and energy performance evaluation of such a cycle.  相似文献   


7.
The rotary process presented here is designed for continuous operation and to use the concept of a heat regeneration cycle developed for solid sorption cold production systems. Based on the analysis of the thermodynamic cycle followed by the reagent, the system is modeled in the form of counter-flow heat exchangers in series. This allows an estimate of the energy performance of the process in terms of coefficient of performance (COP) and cold production capacity. It appears that for a given set of thermodynamic operating conditions, the number of transfer units (NTU) of the heat exchangers is the parameter, which conditions the value of the COP. A comparison between the rotary system by adsorption and by chemical reaction helps to select the ideal reagent according to the temperature level for cold production.  相似文献   

8.
Jet-refrigeration cycles seem to provide an interesting solution to the increasing interest in environment protection and the need for energy saving due to their low plant costs, reliability and possibility to use water as operating fluid. A steam/steam ejector cycle refrigerator is investigated introducing a two-stage ejector with annular primary at the second stage. The steady_state refrigerator, exchanging heat with the water streams at inlet fixed temperatures at the three shell and tube heat exchangers, evaporator, condenser and generator, is considered as an open system. Heat transfer irreversibilities in the heat exchangers and external friction losses in the water streams are considered, ignoring the internal pressure drop of the vapor. A simulation program numerically searches the maximum COP at given external inlet fluid temperatures as a function of mass flows, dimensions and temperature differences in the heat exchangers. The code gives the ejector and heat exchangers design parameters.  相似文献   

9.
This study presents experimental results obtained from a transcritical R744 system using a refrigerant ejector. The results were compared to that of a conventional system with an expansion valve. For the test conditions considered, the cooling capacity and COP simultaneously improved by up to 8% and 7%, respectively. Experiments were analyzed to quantitatively assess the effects on system performance as a result of changes in basic ejector dimensions such as motive nozzle and diffuser sizing. Small angles of 5° yielded best results for the static pressure recovery of the high-speed two-phase flow entering the diffuser. Experiments confirmed that like in a conventional transcritical R744 system with expansion valve, the high-side pressure control integrated into the ejector could be used to maximize the system performance. Numerical simulation results helped identifying this basic trend. Due to difficulties in the ejector throat pressure measurements, a more practical performance metric was introduced in order to quantify overall ejector efficiencies. According to this definition, the prototype ejector was able to recover up to 14.5% of the throttling losses.  相似文献   

10.
A combined-cycle refrigeration system (CCRS) that comprises a conventional refrigeration and air-conditioning system using mechanical compressor (RAC/MC) and an ejector-cooling cycle (EJC) is proposed and studied. The EJC is driven by the waste heat from the RAC/MC and acts as the bottom cycle of the RAC/MC. A system analysis shows that the COP of a CCRS is significantly higher than a single-stage refrigeration system. Improvement in COP can be as high as 18.4% for evaporating temperature of the RAC/MC Te at −5°C. A prototype of the CCRS was built and tested in the present study. Experimental results show that at Te=−4.5°C, COP is improved by 14% for a CCRS. For Te at 5°C, COP can be improved by 24% for a CCRS with higher condensing temperature of the RAC/MC. The present study shows that the CCRS using the ejector-cooling cycle as the bottom cycle of the RAC/MC is viable. Further improvement in COP is possible since the prototype is not designed and operated at an optimal condition.  相似文献   

11.
In this article, a special configuration of Stirling refrigerator for domestic refrigeration purpose is introduced. A thermal buffer tube is installed between the refrigerator cold-end and the expansion piston to improve the system reliability by moving the expansion piston from low temperature to ambient temperature. Furthermore, a commercial oil-lubricated dual-piston compressor is modified to drive the refrigerator, inside which an elastic membrane is used to transfer acoustic work and separate the working gas of the refrigerator from that of the compressor. Experimental investigations on the refrigerator are performed using helium as the working fluid and a cooling power of 200 W at −78 °C is achieved at 15 Hz working frequency and 2.5 MPa mean pressure. Meanwhile, a rough estimation of the refrigerator COP in terms of cooling power divided by input acoustic power gives the value of 0.64. It gives the possibility of building a low-cost, high efficiency domestic refrigerator.  相似文献   

12.
Modern multi-evaporator air-conditioners (MEACs) incorporate variable-speed compressors and variable-opening expansion valves as the actuators for improving cooling performance and energy efficiency. These actuators have to be properly feedback-controlled; otherwise the systems may exhibit even poorer performance than the conventional machines which use fixed-speed compressors and conventional expansion valves. In this paper, feedback controller design for the MEAC system is first addressed through experimental identification. The identification produces a low-order, linear model suitable for controller design. The feedback controller employed is multi-input–multi-output-based and possesses a cascade structure for dealing with the fast and slow dynamics in the system. To determine appropriate control parameters, conditions that establish the stability for the cascade design are given. Due to the deficiency in control inputs, the proposed control structure exhibits steady-state errors in the superheat responses which in turn can produce unacceptable steady-state superheats. To resolve this issue, the reference superheat settings are determined via an optimization procedure so that the resultant steady-state superheats become acceptable. The control experiments indicate that the proposed controller can successfully regulate the indoor temperatures and maintain the steady-state superheat temperatures at acceptable levels.  相似文献   

13.
The main purpose of this study is to investigate the performance of an autocascade refrigeration system using zeotropic refrigerant mixtures of R744/134a and R744/290. One of the advantages of this system is the possibility of keeping the highest pressure of the system within a limit by selecting the composition of a refrigerant mixture as compared to that in the vapor compression system using pure carbon dioxide. Performance test and simulation have been carried out for an autocascade refrigeration system by varying secondary fluid temperatures at evaporator and condenser inlets. Variations of mass flow rate of refrigerant, compressor power, refrigeration capacity, and coefficient of performance (COP) with respect to the mass fraction of R744 in R744/134a and R744/290 mixtures are presented at different operating conditions. Experimental results show similar trends with those from the simulation. As the composition of R744 in the refrigerant mixture increases, cooling capacity is enhanced, but COP tends to decrease while the system pressure rises.

Résumé

The main purpose of this study is to investigate the performance of an autocascade refrigeration system using zeotropic refrigerant mixtures of R744/134a and R744/290. One of the advantages of this system is the possibility in keeping the highest pressure of the system within a limit by selecting the composition of a refrigerant mixture as compared to that in the vapor compression system using pure carbon dioxide. Performance test and simulation have been carried out for an autocascade refrigeration system by varying secondary fluid temperatures at evaporator and condenser inlets. Variations of mass flow rate of refrigerant, compressor power, refrigeration capacity, and coefficient of performance (COP) with respect to the mass fraction of R744 in R744/134a and R744/290 mixtures are presented at different operating conditions. Experimental results show similar trends with those from the simulation. As the composition of R744 in the refrigerant mixture increases, cooling capacity is enhanced, but COP tends to decrease while the system pressure rises.  相似文献   


14.
The objectives of this study are to analyze performance characteristics during partial load operation and to calculate energy consumption amount of H2O/LiBr absorption chiller with a capacity of 210 RT. The effect of cooling water flow rate and cooling water inlet temperature on the absorption performance and energy saving is quantified during the partial load operation. It is found that the performance of absorption system is more sensitive to the change of inlet water temperature rather than the cooling water flow rate. Even if the cooling water flow rate is reduced to 60% of the standard value, the capacity is recovered if the temperature of cooling water decreases about 2.0 °C. The pumping power of cooling water is 4 times higher than that of cooling tower during the partial operation mode and the pumping power of cooling water becomes more significant with decreasing the partial load. It is concluded that when the partial load is in the range of 100–40%, the reduction of the required power by 23% can be realized by decreasing the cooling water inlet temperature of 1.0 °C.  相似文献   

15.
A vapor compression cycle with a solution circuit and desorber/absorber heat exchange (DAHX) has been investigated experimentally using the ammonia/water mixture. A breadboard heat pump was designed and built to measure the cycle performance. COPs in the range of 1.2–1.8 were obtained experimentally for a temperature lift between 60 and 80°C. The cooling capacities were between 7 and 12 kW, which increased with an increase of the ammonia concentration. The pressure ratios encountered were in the range of 2–6. A COP of 1.44 at the temperature lift of 79°C was recorded with a cooling capacity at 10.25 kW. The experimental results are compared to that of the single-stage and two-stage cycle. The two-stage system had the highest temperature lift (110–120°C) and the lowest COP (0.69–1.04). The single-stage system has the highest COP (2.2–3.5) but the lowest temperature lift (40°C). Also, a solution bypass between the Absorber I outlet and Desorber II inlet was proposed to improve the cycle performance. The experimental results showed that the COP varied in the range of 1–2%, while the temperature lift increased by the range between 0 and 6°C. In addition, the analysis of the test result uncertainties was made.  相似文献   

16.
A theoretical and experimental study is presented and a mathematical model is introduced for a heat driven refrigeration system operating with continuous temperature control. The model consists of a refrigerated space, an absorption refrigerator, operating irreversibly, a temperature sensor and a reference signal, and a power law control action. The steady-state behavior of the absorption refrigerator model is validated by direct comparison between theoretical results and experimental data. The model is then used to identify an optimal thermal conductance allocation, for a fixed total thermal conductance inventory, such that the refrigeration rate is maximized and the ‘pull-down' time is minimized. A simulation of the system operating in a transient mode is carried out to show that closed-loop operation results in a large reduction of fuel consumption, with respect to the ‘on–off' operation. Appropriate dimensionless groups are identified and the generalized results reported in charts using dimensionless variables.  相似文献   

17.
An innovative hybrid hollow fiber membrane absorber and heat exchanger (HFMAE) made of both porous and nonporous fibers is proposed and studied via mathematical simulation. The porous fibers allow both heat and mass transfers between absorption solution phase and vapor phase, while the nonporous fibers allow heat transfer between absorption solution phase and cooling fluid phase only. The application of HFMAE on an ammonia–water absorption heat pump system as a solution-cooled absorber is analyzed and compared to a plate heat exchanger falling film type absorber (PHEFFA). The substantially higher amount of absorption obtained by the HFMAE is made possible by the vast mass transfer interfacial area per unit device volume provided. The most dominant factor affecting the absorption performance of the HFMAE is the absorption solution phase mass transfer coefficient. The application of HFMAE as the solution-cooled absorber and the water-cooled absorber in a typical ammonia–water absorption chiller allows the increase of COP by 14.8% and the reduction of the overall system exergy loss by 26.7%.  相似文献   

18.
This paper focuses on cascading an ideal vapor compression cycle and determining the optimal intermediate temperatures based on the entropy generation minimization method. Only superheating and throttle losses of the cycle are considered since they are inherent to the ideal vapor compression refrigeration cycle. The second law equations have been developed in terms of specific heats and temperature ratios with the intent of reducing involved property modeling. Also the entropy generation was expressed in terms of a single independent variable and minimized to develop an advanced rule for selecting optimum intermediate temperatures. Results for a cascade system operating between reduced temperatures of 0.684 and 0.981 with R-134a as the working fluid are presented. The approximate method presented here predicted the optimum intermediate reduced temperature for a two-stage system to be 0.88, a difference of 2% from the optimum. The method presented was a much better predictor of the optimum temperature than the geometric mean method which was 0.82, a difference of 5% from the optimum. The entropy generation distribution of the optimum solution was investigated. For a two-stage system, the lower stage and higher stage entropy generation was 44% and 56%, respectively. In comparison to the single stage, the two-stage reduced losses by 78%.  相似文献   

19.
20.
Emerging triple-effect LiBr–water absorption chillers operate at higher temperatures and pressures than traditional double-effect chillers. However, there is not enough data about thermodynamic properties of LiBr–water solutions at such high temperatures. Using recently measured data of vapor pressure and heat capacity, we have developed the equations which can calculate the vapor pressure, enthalpy and entropy of LiBr solutions at such high temperatures. The developed equations are valid from concentrations of 40–65 wt.% and also from temperatures of 40–210°C. These equations will be very helpful for the modeling and design of triple-effect LiBr–water chillers.  相似文献   