1.
An up-flow anaerobic sludge blanket (UASB) - down-flow hanging sponge (DHS) was applied to Japanese municipal sewage treatment, and its treatability, energy consumption, and sludge production were evaluated. The designed sewage load was 50 m(3)/d. The sewage typically had a chemical oxygen demand (COD) of 402 mg/L, a suspended solids (SS) content of 167 mg/L, and a temperature of 17-29 °C. The UASB and DHS exhibited theoretical hydraulic retention times of 9.7 and 2.5 h, respectively. The entire system was operated without temperature control. Operation was started with mesophilic anaerobic digested sludge for the UASB and various sponge media for the DHS. Continuous operational data suggest that although the cellulose decomposition and methanogenic process in the UASB are temperature sensitive, stable operation can be obtained by maintaining a satisfactory sludge volume index and sludge concentration. For the DHS, the cube-type medium G3-2 offers superior filling rates, biological preservation and operational execution. The SS derived from the DHS contaminated the effluent but could be removed by optional sand filtration. A comparison with conventional activated sludge (CAS) treatment confirmed that this system is adequate for municipal sewage treatment, with an estimated energy requirement and excess sludge production approximately 75 and 85% less than those of CAS, respectively.  相似文献   

2.
In TFT-LCD industry, water plays a variety of roles as a cleaning agent and reaction solvent. As good quality water is increasingly a scarce resource and wastewater treatment costs rises, the once-through use of industrial water is becoming uneconomical and environmentally unacceptable. Instead, recycling of TFT-LCD industrial wastewater is become more attractive from both an economic and environmental perspective. This research is mainly to explore the capacity of TFT-LCD industrial wastewater recycling by the process combined with membrane bioreactor and reverse osmosis processes. Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 97.3%. For TOC and BOD5 items, the average removal efficiencies were 97.8 and 99.4% respectively. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of the UF membrane device incorporated with biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After treatment of RO, excellent water quality of permeate were under 5 mg/l, 2.5 mg/l and 150 micros/cm for COD, TOC and conductivity respectively. The treated water can be recycled for the cooling tower make-up water or other purposes.  相似文献   

3.
以某大型制浆造纸厂废水处理工程为例,介绍了水解酸化—好氧生物处理联合Fenton氧化深度处理工艺在造纸和制浆中段废水处理中的应用。厂内造纸废水量为0.77万~2.91万m3/d,COD为2 150~4 430mg/L,SS为1 316~2 414mg/L,经生化处理后,出水COD和SS平均分别为309mg/L和53mg/L;制浆废水量为0.84万~3.68万m3/d,COD为1 720~4 360mg/L,SS为1 184~1 994mg/L,生化处理出水COD和SS平均分别为370mg/L和56mg/L。两种废水的生化处理出水经Fenton氧化和絮凝沉淀处理后,出水COD为67~98mg/L,SS为21~29mg/L,可达《制浆造纸工业水污染物排放标准》(GB 3544—2008)排放要求。废水处理成本为2.01元/m3,具有良好的经济效益和环境效益。  相似文献   

4.
This research project aimed to determine the technologically feasible and applicable wastewater treatment systems which will be constructed to solve environmental problems caused by small communities in Turkey. Pilot-scale treatment of a small community's wastewater was performed over a period of more than 2 years in order to show applicability of these systems. The present study involves removal of organic matter and suspended solids in serially operated horizontal (HFCW) and vertical (VFCW) sub-surface flow constructed wetlands. The pilot-scale wetland was constructed downstream of anaerobic reactors at the campus of TUBITAK-MRC. Anaerobically pretreated wastewater was introduced into this hybrid two-stage sub-surface flow wetland system (TSCW). Wastewater was first introduced into the horizontal sub-surface flow system and then the vertical flow system before being discharged. Recirculation of the effluent was tested in the system. When the recirculation ratio was 100%, average removal efficiencies for TSCW were 91 +/- 4% for COD, 83 +/- 10% for BOD and 96 +/- 3% for suspended solids with average effluent concentrations of 9 +/- 5 mg/L COD, 6 +/- 3 mg/L BOD and 1 mg/L for suspended solids. Comparing non-recirculation and recirculation periods, the lowest effluent concentrations were obtained with a 100% recirculation ratio. The effluent concentrations met the Turkish regulations for discharge limits of COD, BOD and TSS in each case. The study showed that a hybrid constructed wetland system with recirculation is a very effective method of obtaining very low effluent organic matter and suspended solids concentrations downstream of anaerobic pretreatment of domestic wastewaters in small communities.  相似文献   

5.
With a view to a reduction of the discharge from combined water outflow, the increase of the influent to a wastewater treatment plant can be an efficient solution, for cases in which the discharge concentration of the wastewater treatment plant would not deteriorate significantly as a result. Through bypassing the aeration with combined water and a direct feed of the combined water into the final clarification (Mina-Process) the specific sludge volume loading, which is significant to the efficiency of the final clarification, will not be raised. But the adsorption capability of the aerated sludge, the sedimentation effect of the final clarification, and the partial recirculation over return-sludge can be used for an elimination of suspended solids, chemical oxygen demand (COD), ammonia and phosphate from the combined wastewater. In large-scale tests in Wilhelmshaven (160,000 PE), removal efficiencies for the elimination in the bypass of 75% of COD, 60% of ammonia and 89% of suspended solids were reached. In comparison with conventional procedures for combined water treatment (e.g. storage volumes, soil filter) the Mina-Process has the possibility to achieve a highly efficient and economical combined water treatment by using the capability of existing clarifiers.  相似文献   

6.
雷萍  朱佳 《给水排水》2012,38(5):129-132
针对某条流经城市人口密集区域河流的重度污染现状,在多个断面布点,对干流和支流水质进行了全面监测,以追踪分析水质变化趋势和污染成因.结果显示,该河流从上游到下游水质有所好转,COD从321 mg/L下降至100~135 mg/L,BOD5从226 mg/L下降至27~36 mg/L,悬浮物从159 mg/L下降至15~30 mg/L,总磷从8.91 mg/L下降至3~4 mg/L.位于河流上游的污水处理厂在水质改善中发挥了重要作用,COD整体去除率达到77.6%,但不能根本改善河流的污染现状.4条支流污染严重,是造成干流水质污染的主要原因,COD均在230 mg/L以上,最高达到512mg/L,BOD5最高达295 mg/L.对支流D实行重点监测,发现氨氮和总氮规律性升高,镍、锰、铜、锌、铬等重金属多次检出,铅的检出率高达77.1%.针对污染现状提出了治理建议.  相似文献   

7.
Fenton试剂处理港口化学品洗舱废水   总被引:1,自引:0,他引:1  
根据珠海某港口化学品洗舱废水的组成,配置甲醛、甲苯、苯酚的单独污染物模拟废水,采用Fenton试剂对港口废水和模拟废水进行氧化处理。通过实验探讨了不同的H2O2和Fe2+浓度、pH值、反应时间下各种废水COD的去除情况,确定了各种废水最佳的操作条件。港口废水在最佳的操作条件下COD去除率约为88%,废水的COD质量浓度从2 000~2 200 mg/L降到低于280 mg/L,废水由原来的无法生化变为易生物降解。苯酚、甲醛、甲苯模拟废水在各自最佳的操作条件下,COD去除率也都达到85%以上。  相似文献   

8.
Chemical pre-treatment of synthetic Procaine Penicillin G (PPG) effluent with ozone (applied dose = 1440 mg/h; treatment duration = 60 min) at pH = 7 was investigated. Successive biological treatability studies were performed with raw, ozonated penicillin formulation effluent and synthetic readily biodegradable substrate as simulated domestic wastewater. The PPG effluent additions were adjusted to constitute approximately 30% of the total COD in the reactor. Ozonation of PPG effluent resulted in practically complete removal of the parent pollutant accompanied by 40% COD abatement. Speaking for the raw PPG effluent, prolonged acclimation periods were necessary to obtain significant COD removal efficiencies. Batch activated sludge treatment experiments and respirometric studies have demonstrated that the selection of true retention time is extremely crucial for having high amount of slowly hydrolysable substrate or complex wastewater, like pharmaceutical effluent. The effect of ozonation time on biological treatability performance of PPG has been evaluated in the study. Pre-ozonation of PPG effluent did not improve its ultimate biodegradability.  相似文献   

9.
为探寻污水厂二级出水深度处理方法,以阜新市某污水处理公司二级出水为研究对象,进行H2O2与沸石联用去除水中COD、氨氮的研究。结果表明:在二氧化锰的催化作用下,pH值为7时,H2O2和沸石的投加量分别为1.5mL和2g,二级出水的COD从138.24mg/L降到52.76mg/L,去除率达到75.36%,NH3-N从20mg/L降到5mg/L,去除率为74.59%,出水有机物和氨氮含量达到国家相关出水标准。  相似文献   

10.
In order to treat wastewater to a low residual COD-concentration such as 125 mg/L, classical biological treatment is not sufficient for many types of industry. This research focused on the integrated treatment of the wastewater of the paper industry, with a membrane bioreactor (MBR) and an oxidation step. The optimal configuration was examined. Screening tests with different types of oxidation showed that ozonation after biological treatment could reduce the COD with 40% with an ozone dose of 0.4-0.8g O3/g COD. BOD/COD ratio could be increased up to 0.19. Neither combination of ozone with UV and/or hydrogen peroxide nor the process H2O2/UV or (photo-)Fenton reagents gave any improvement in COD reduction or BOD increase, unless the doses were very high. Based on these results, an integrated system MBR-ozonation was designed, with recirculation of MBR effluent over ozonation. This test showed that reduction of COD up to 125 mg/L immediately behind the MBR required a lot of ozone. A technically feasible solution was to discharge the water after an extra ozonation step, which resulted in a high total ozone dosage. The alternative, the consecutive treatment activated sludge-ozonation-activated sludge, did not give a better COD-removal with the same ozone dose as the integrated concept. The economic evaluation proves that the integrated chemical and biological treatment is expensive for the paper industry if a low discharge limit of COD has to be complied with.  相似文献   

11.
The operation of an activated sludge process at a paper mill (AIPM) in Hedera, Israel, was often characterized by disturbances. As part of a research and development project, a study on new biological treatment was initiated. The study included the operation of three pilot units: a. anaerobic treatment by upflow anaerobic sludge blanket (UASB); b. aerobic treatment by two pilot units including activated sludge and membrane bioreactor (MBR), which have been operated in parallel for comparison reasons. The pilot plant working on anaerobic treatment performed COD reduction from 2,365 to 755 mg/L, expressed as average values. Based on the pilot study, a full scale anaerobic treatment system has been erected. During a period of 100 days, after achieving steady state, the MBR system provided steady operation performance, while the activated sludge produced effluent characterized by oscillatory qualities. The following results, based on average values, indicate much lower suspended solids concentrations in the MBR effluent, 2.5 mg/L, as compared to 25 mg/L in the activated sludge. The ability to develop and maintain a concentration of over 11,000 mg/L of mixed liquor volatile suspended solids in the MBR enabled an intensive bioprocess at relatively high cell residence time. This study demonstrates that the anaerobic process, followed by aerobic MBR can provide effluent of high quality which can be considered for economic reuse in the paper mill industry.  相似文献   

12.
超临界水氧化技术在城市污泥处理中的应用   总被引:1,自引:0,他引:1  
综述了超临界水氧化(SCWO)技术的基本原理和工艺、在城市污泥处理中应用的国内外研究进展,并就SCWO处理城市污泥的前景作了展望。SCWO技术处理城市污泥,污泥中有机物的去除率可达99.9%以上,污泥氧化后的最终残余固体产物的容积仅为浓缩污泥容积的1.2%左右,反应后剩余收集液的COD质量浓度小于10 mg/L,处理后的残留固体还可以进行磷酸盐和重金属回收。  相似文献   

13.
城市小区雨水径流水质的污染主要为有机污染和悬浮固体污染,且污染物的可生化性差,采用投加混凝剂同时加细砂的强化混凝沉淀实验,确定了小区径流混凝沉淀处理最适宜的混凝剂种类、最佳的混凝反应运行条件及最优的药剂和细砂投加量.实验表明:在混凝沉淀过程中投加细砂,不仅能提高混凝沉淀效果,而且能提高沉淀速度.小区径流强化混凝沉淀的浊度去除率达99.7%,COD去除率达92.6%,处理水的浊度1.66 NTU,COD 35mg/L两主要指标均优于杂用水水质标准.因此,投加细料的混凝沉淀是小区雨水径流处理利用及污染控制最简便易行且有效的处理方法.  相似文献   

14.
Wine production is seasonal, and thus the wastewater flow and its chemical oxygen demand (COD) concentrations greatly vary during the vintage and non-vintage periods, as well as being dependant on the winemaking technologies used, e.g. red, white or special wines production. Due to this seasonal high variability in terms of organic matter load, the use of membrane biological reactors (MBR) could be suitable for the treatment of such wastewaters. MBR offers several benefits, such as rapid start up, good effluent quality, low footprint area, absence of voluminous secondary settler and its operation is not affected by the settling properties of the sludge. A pilot scale hollow fibre MBR system of 220 L was fed by adequately diluting white wine with tap water, simulating wastewaters generated in wineries. The COD in the influent ranged between 1,000 and 4,000 mg/L. In less than 10 days after the start up, the system showed a good COD removal efficiency. The COD elimination percentage was always higher than 97% regardless of the organic loading rate (OLR) applied (0.5-2.2 kg COD/m3 d), with COD concentrations in the effluent ranging between 20 and 100 mg/L. Although the biomass concentration in the reactor increased from 0.5 to 8.6 g VSS/L, the suspended solids concentration in the effluent was negligible. Apparent biomass yield was estimated in 0.14 g VSS/g COD.  相似文献   

15.
在对洗车用水特点及高效循环水洗车技术进行分析的基础上,针对当前洗车行业耗水量大、洗车废水污染环境等问题,结合北京社会发展、水资源状况、节水力度、行业节水推广情况,阐述了基于WR-RO、WR-UF技术的洗车循环用水设备的工艺流程、技术特征、运行工况及处理效果。洗车废水中含有油污、泥砂、表面活性剂及其他可溶性有机物。以超滤为核心工艺处理洗车废水,对浊度、COD、阴离子表面活性剂的去除率分别为98%、68%、69%。高效循环水洗车技术具有可操作性强、处理水质安全、运行成本低、效益可观等特点,应用推广价值高。  相似文献   

16.
For the treatment of paracetamol in water, the UV-C Fenton oxidation process and classic Fenton oxidation have been found to be the most effective. Paracetamol reduction and chemical oxygen demand (COD) removal are measured as the objective functions to be maximized. The experimental conditions of the degradation of paracetamol are optimized by the Fenton process. Influent pH 3, initial H(2)O(2) dosage 60 mg/L, [H(2)O(2)]/[Fe(2+)] ratio 60 : 1 are the optimum conditions observed for 20 mg/L initial paracetamol concentration. At the optimum conditions, for 20 mg/L of initial paracetamol concentration, 82% paracetamol reduction and 68% COD removal by Fenton oxidation, and 91% paracetamol reduction and 82% COD removal by UV-C Fenton process are observed in a 120 min reaction time. By HPLC analysis, 100% removal of paracetamol is observed at the above optimum conditions for the Fenton process in 240 min and for the UV-C photo-Fenton process in 120 min. The methods are effective and they may be used in the paracetamol industry.  相似文献   

17.
The Kaldnes biomedia K1, which is used in the patented Kaldnes Moving Bed biofilm process, has been tested along with other types of biofilm carriers for biological pretreatment of a complex chemical industry wastewater. The main objective of the test was to find a biofilm carrier that could replace the existing suspended carrier media and at the same time increase the capacity of the existing roughing filter-activated sludge plant by 20% or more. At volumetric organic loads of 7.1 kg COD/m3/d the Kaldnes Moving Bed process achieved much higher removal rates and much lower effluent concentrations than roughing filters using other carriers. The Kaldnes roughing stage achieved more than 85% removal of organic carbon and more than 90% removal of BOD5 at the tested organic load, which was equivalent to a specific biofilm surface area load of 24 g COD/m2/d. Even for the combined roughing filter-activated sludge process, the Kaldnes carriers outperformed the other carriers, with 98% removal of organic carbon and 99.6% removal of BOD5. The Kaldnes train final effluent concentrations were only 22 mg FOC/L and 7 mg BOD5/L. Based on the successful pilot testing, the full-scale plant was upgraded with Kaldnes Moving Bed roughing filters. During normal operation the upgraded plant has easily met the discharge limits of 100 mg COD/L and 50 mg SS/L. For the month of September 2002, with organic loads between 100 and 115% of the design load for the second half of the month, average effluent concentrations were as low as 9 mg FOC/L, 51 mg COD/L and 12 mg SS/L.  相似文献   

18.
This work aims to investigate removal efficiency of oxidation and coagulation/flocculation processes, to provide an effective method for the treatment of biologically pre-treated leachate. Leachate containing 985 mg L(-1) COD was treated by using three treatment schemes, i.e. oxidation, coagulation/flocculation and the combined process of coagulation/flocculation followed by oxidation. The application of single oxidation resulted in the effective removal of COD and color up to 80.4 and 83.2%, respectively. However, residual COD values lower than 200 mg L(-1) could only be achieved under intensive experimental conditions (high dosage of Ca(ClO)(2) and prolonged oxidation time). Coagulation/flocculation yielded residual COD values higher than 200 mg L(-1) even at the optimum coagulation conditions. The combined treatment by coagulation/flocculation followed by oxidation yielded final COD lower than 100 mg L(-1) at the following conditions: pre-coagulation with 250 mg L(-1) PFS (poly-ferric sulfate) and over 30-min post-oxidation, or pre-coagulation with 300 mg L(-1) PFS and over 20-min post-oxidation. Hence, pre-coagulation with PFS followed by oxidation with Ca(ClO)(2) was recommended for advanced treatment of biologically treated leachate.  相似文献   

19.
维生素制药废水经过初步生化处理后,出水水质无法满足要求,具有难降解、COD和氨氮浓度高的特点,针对这些特点,本文采用"强化复合曝气水解酸化→高效厌氧复合反应→流离生物接触氧化"连续工艺深度处理维生素制药废水,研究其可行性。处理规模为7.2 m3/d的中型试验结果表明:强化复合曝气水解酸化能使进水B/C值由0.33提高到0.48,提高下一步生化反应的处理效率,当进水CODCr的浓度为150~641 mg/L,氨氮浓度为6~115 mg/L时,平均去除率分别达到84.28%、93.8%,出水COD浓度小于50mg/L,氨氮浓度小于5 mg/L,出水水质能够达到《城镇污水处理厂污染物排放标准》GB18918-2002中的一级A指标,该连续工艺深度处理此类废水具有可行性和稳定性。  相似文献   

20.
焦跃腾  顾正华  丁昊  周欣 《人民长江》2017,48(21):23-28
电絮凝作为一种具有广泛应用前景的低廉高效污水处理技术,已经被证明在工业废水、生活污水等污染严重的水体处理上具有显著效果,但是目前对于电絮凝净化微污染水的相关研究较少。通过对电絮凝分批处理河水的实验研究,分析电絮凝方法处理微污染水的可行性,讨论极板间距的改变对电絮凝处理效果的影响。结果表明,电絮凝处理技术可以用于微污染水净化中,在电流密度为17.75 A/m2、极板间距为1.5 cm的条件下,反应30 min时,色度去除率为73.76%,浊度去除率为76.00%,悬浮固体去除率为85.71%,化学需氧量去除率为42.86%,总磷去除率为61.36%。在电絮凝反应中,极板间距对于微污染水的色度、浊度、悬浮固体和总磷去除效果具有明显的影响。  相似文献   