首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The growing demand on water resources has increased the interest in wastewater reclamation for multiple end-use applications such as indirect and direct potable reuse. In these applications, the removal of organic micropollutants is of a greater concern than in conventional wastewater treatment. This article presents a collection of data of trace organic micropollutants in an urban wastewater treatment plant (WWTP) in North East Spain using reverse osmosis (RO) membrane treatment. The RO rejection values of the organic molecules studied with a wide range of solute size and hydrophobicity were determined. Several chromatographic methods monitoring different endocrine disrupting chemicals (EDCs), pharmaceuticals and personal care products (PPCPs) were used. Results indicated that secondary effluents from this Spanish WWTP contained most of the studied organic compounds indicating incomplete removal of organics in the conventional treatment of the plant. However, the rejection of most micropollutants was high for all three RO membrane types (low energy, high rejection, fouling resistant) tested. It was observed that some selected micropollutants were less efficiently removed (e.g. the small and polar and the more hydrophobic) and the molecular weight and membrane material influenced removal efficiencies.  相似文献   

2.
New stricter nitrogen effluent standards and increasing influent loads require existing wastewater treatment plans (WWTPs) to extend or optimize. At WWTPs with limited aeration capacity, limited denitrification capacity or shortage of aerobic sludge age, implementation of SHARON to improve nitrogen effluent quality can be a solution. SHARON is a compact, sustainable and cost-effective biological process for treatment of nitrogen-rich rejection waters. At WWTP Rotterdam-Dokhaven and WWTP Utrecht a SHARON has been in operation for several years. For both WWTPs the effect of SHARON on the nitrogen effluent quality has been evaluated. WWTP Rotterdam-Dokhaven has limited aeration capacity. By implementation of SHARON, the ammonia load of the effluent was reduced by 50%. WWTP Utrecht had limited denitrification capacity. The implementation of SHARON improved the effluent nitrate load by 40%. The overall TN removal efficiency increased from 65% to over 75% and strict nitrogen effluents standards (TN = 10 mg N/l) could be reached. Through modelling and supported by full scale practice it has been shown that by implementation of SHARON in combination with enhanced influent pre-treatment, the aerobic sludge age can be extended to maintain total nitrogen removal at lower temperatures.  相似文献   

3.
In TFT-LCD industry, water plays a variety of roles as a cleaning agent and reaction solvent. As good quality water is increasingly a scarce resource and wastewater treatment costs rises, the once-through use of industrial water is becoming uneconomical and environmentally unacceptable. Instead, recycling of TFT-LCD industrial wastewater is become more attractive from both an economic and environmental perspective. This research is mainly to explore the capacity of TFT-LCD industrial wastewater recycling by the process combined with membrane bioreactor and reverse osmosis processes. Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 97.3%. For TOC and BOD5 items, the average removal efficiencies were 97.8 and 99.4% respectively. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of the UF membrane device incorporated with biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After treatment of RO, excellent water quality of permeate were under 5 mg/l, 2.5 mg/l and 150 micros/cm for COD, TOC and conductivity respectively. The treated water can be recycled for the cooling tower make-up water or other purposes.  相似文献   

4.
An integrated membrane process (IMP) comprising a membrane bioreactor (MBR) and a reverse osmosis (RO) process was developed for water reclamation. Wastewater was treated by an MBR operated at a sludge retention time (SRT) of 20 days and a hydraulic retention time (HRT) of 5.5 h. The IMP had an overall recovery efficiency of 80%. A unique feature of the IMP was the recycling of a fraction of RO concentrate back to the MBR. Experimental results revealed that a portion of the slow- and hard-to-degrade organic constituents in the recycle stream could be degraded by an acclimated biomass leading to an improved MBR treatment efficiency. Although recycling concentrated constituents could impose an inhibitory effect on the biomass and suppress their respiratory activities, results obtained suggested that operating MBR (in the novel IMP) at an F/M ratio below 0.03 g TOC/g VSS.day could yield an effluent quality comparable to that achievable without concentrate recycling. It is noted in this study that the novel IMP could achieve an average overall TOC removal efficiency of 88.940% and it consistently produced product water usable for high value reuse applications.  相似文献   

5.
采用连续微滤(CMF)作为反渗透(RO)的预处理工艺,对印染废水二级生化出水进行深度处理。结果表明:CMF处理系统运行稳定,对色度、膜污染指数值的去除率均达到RO系统进水的要求。RO系统对盐度的去除率达到98%以上,出水水质优于自来水,各项水质指标满足印染工艺回用的要求。  相似文献   

6.
试验采用超滤+反渗透集成膜分离技术,目的是研究其集成工艺处理有色冶金工业废水的合理性和可行性。超滤试验主要测试了在不同水质情况下超滤膜的相关运行参数,主要测定指标有超滤系统的进水、产水和反冲洗水的水量,运行压力,出水浊度,SDI值等;反渗透试验主要测定指标有电导率,反渗透系统的进、出水量,运行压力等。试验研究表明:以预处理+超滤+反渗透组成的集成膜处理工艺,能够满足有色冶金工业废水处理回用的要求。  相似文献   

7.
A pilot scale membrane plant was constructed and monitored in Shah Alam, Malaysia for municipal wastewater reclamation for industrial application purposes. The aim of this study was to verify its suitability under the local conditions and environmental constraints for secondary wastewater reclamation. Immersed-type crossflow microfiltration (IMF) was selected as the pretreatment step before reverse osmosis filtration. Secondary wastewater after chlorine contact tank was selected as feed water. The results indicated that the membrane system is capable of producing a filtrate meeting the requirements of both WHO drinking water standards and Malaysian Effluent Standard A. With the application of an automatic backwash process, IMF performed well in hydraulic performance with low fouling rate being achieved. The investigations showed also that chemical cleaning is still needed because of some irreversible fouling by microorganisms always remains. RO treatment with IMF pretreatment process was significantly applicable for wastewater reuse purposes and promised good hydraulic performance.  相似文献   

8.
The Mediterranean seaside resort of Le Grau du Roi includes 40 hectares of landscaped areas spray irrigated with river water supplied through a separate network. Wastewater collected from several municipalities is treated in an activated sludge wastewater treatment plant (WWTP) and polished in waste stabilization ponds (WSPs). Planned substitution of treated wastewater for river water is hindered by spray irrigation prohibition within a 100 m distance from houses and recreational areas. WWTP and WSP effluents were monitored for pathogens with a particular attention to Legionella in Spring and Summer 2006. Helminth eggs, salmonellae and enteroviruses were never detected neither in WWTP effluent nor in the ponds. Legionella spp content was slightly higher or of the order of magnitude of river water contents. Regarding Legionella pneumophila contents, WSP effluent did not significantly differ from the river water. E.coli and enterococci contents in WSP effluents complied with the "excellent quality" criteria of the European Directive for coastal bathing waters. Therefore, substituting WSP effluents to river water is unlikely to alter health risks related to spray irrigation and, in this case, the buffer zone required by the French water reuse guidelines appears being short of support.  相似文献   

9.
We created a database in order to quantitatively assess the occurrence and removal efficiency of PPCPs in WWTPs. From 113 scientific publications, we compiled 5887 data on the concentrations and loads of PPCPs in WWTP influents and effluents, and on their removal efficiency. The first outputs of our database include: (1) a list of the most frequently studied molecules, their frequency of detection, their mean concentration and removal in liquid influent and effluent; (2) a comparison of the removal efficiency for different WWTP processes; (3) a study of the influence of the operating conditions (sludge and hydraulic retention times).  相似文献   

10.
A brief review of the fate of micropollutants in membrane-based wastewater treatment due to sorption, stripping, biological degradation/transformation and membrane separation is discussed, to give an overview of these technologies due to the growing importance for water reuse purposes. Compared with conventional activated sludge treatment (CAS) micropollutant removal in membrane bioreactor (MBR) is slightly improved due to complete suspended solids removal and increased sludge age. For discharge to sensitive receiving waters advanced treatment, such as post-ozonation or activated carbon adsorption, is recommended. In water reuse plants nanofiltration (NF) and reverse osmosis (RO) efficiently reject micropollutants due to size exclusions as well as electrostatic and hydrophobic effects reaching potable quality. To remove micropollutants fully, additionally post-ozone or the addition of powdered activated carbon (PAC) have to be applied, which in parallel also reduce NDMA precursors. The concentrate has to be treated if disposed to sensitive receiving waters due to its high micropollutant concentration and ecotoxicity potential. The present review summarizes principles and capabilities for the most important membrane-based applications for wastewater treatment, i.e. porous membranes in MBRs (micro- or ultrafiltration) and dense membrane applications (NF and RO) for water reuse.  相似文献   

11.
Discharge waters from activated sludge processes in the pulp and paper industry and from a municipal wastewater treatment plant were filtered with various nanofiltration (NF) and low pressure reverse osmosis (RO) membranes. The purpose was to study flux, retention, and permeate quality after membrane filtration by using a high shear (CR-250/2) filter. The suitability of the achieved permeates for reuse at the industrial site is also discussed. The NF permeate was practically free from colour and organic compounds but contained significant amount of inorganic compounds e.g. chloride ions, especially when a high amount of sulphate containing discharge waters were filtered, in which case a low pressure RO membrane was needed to successfully remove monovalent anions. Organic compounds were almost completely retained by NF and RO membranes and organic carbon in the permeate was less than 10 mg/dm3 on average. The achieved permeate can easily be reused in paper production. Nanofiltration has a significantly higher flux and also a lower fouling tendency than reverse osmosis but it passes through monovalent ions when there is a high sulphate concentration in the water. Therefore, RO might be needed in such cases to produce excellent process water.  相似文献   

12.
Upgrading of wastewater treatment plant (WWTP) effluent as a part of the Dutch governmental policy to close the water cycle has increasing interest now. The Water Board Hoogheemraadschap van Delfland together with the project team of Witteveen + Bos Consulting Engineers, Delft University of Technology and Rossmark water treatment investigated the reuse possibilities of WWTP effluent in the region of Delfland. Therefore pilot research was carried out at WWTP Hoek van Holland applying different filtration techniques: multi-media filtration, micro- and ultrafiltration. The results show stable process performances of the different filtration techniques when proper pre-treatment was applied. For microfiltration the filtration characteristics were strongly influenced by particles which were not retained in the multi-media filter. For ultrafiltration the filtration characteristics were strongly influenced by organic components < 0.2 microm. The upgraded WWTP effluent could not be used directly as process water or for agriculture purposes, due to high concentrations of COD and salts in the WWTP effluent and filtrates. However WWTP effluent or floc filtrate could be applied directly as water for the washing of sea-sand.  相似文献   

13.
In wastewater treatment plants (WWTPs) equipped with sludge digestion and dewatering systems, the reject water originating from these facilities contributes significantly to the nitrogen load of the activated sludge tanks, to which it is typically recycled. In this paper, the impact of reject water streams on the performance of a WWTP is assessed in a simulation study, using the Benchmark Simulation Model no. 2 (BSM2), that includes the processes describing sludge treatment and in this way allows for plant-wide evaluation. Comparison of performance of a WWTP without reject water with a WWTP where reject water is recycled to the primary clarifier, i.e. the BSM2 plant, shows that the ammonium load of the influent to the primary clarifier is 28% higher in the case of reject water recycling. This results in violation of the effluent total nitrogen limit. In order to relieve the main wastewater treatment plant, reject water treatment with a combined SHARON-Anammox process seems a promising option. The simulation results indicate that significant improvements of the effluent quality of the main wastewater treatment plant can be realized. An economic evaluation of the different scenarios is performed using an Operating Cost Index (OCI).  相似文献   

14.
This paper reports on the potential for water reuse in the malting sector. Core unit of a treatment train to close the water loop was a membrane bioreactor (MBR). Three different commercial submerged membranes were compared in terms of their fouling potential in this application. In a second step, MBR permeate was subjected to reverse osmosis (RO) and several oxidation processes. Neither the MBR permeate nor the RO permeate or oxidized water streams showed an adverse effect on malt quality. The worst case scenario was then tested in a closed water loop over several malting cycles at pilot scale and the effect on water and malt quality investigated.  相似文献   

15.
UASB reactors followed by polishing ponds comprise simple and economic wastewater treatment systems, capable of reaching very high removal efficiencies of pathogenic organisms, leading to the potential use of the effluent for unrestricted irrigation. However, for other types of reuse (urban and industrial), ponds are limited in the sense of producing effluents with high suspended solids (algae) concentrations. The work investigates a system with coarse rock filters for polishing the pond effluent. The overall performance of the system is analyzed, together with the potential for different types of reuse. The excellent results obtained (mean effluent concentrations: BOD: 27 mg/L; SS: 26 mg/L; E. coli: 450 MPN/100 mL) indicate the possibility of unrestricted use of the effluent for agriculture and restricted urban and industrial uses, according to WHO and USEPA.  相似文献   

16.
At many large wastewater treatment plants (WWTPs) the increased hydraulic load, caused by combined sewer systems during storm events, results in primary effluent overflow when the capacity of further treatment is exceeded. Due to stringent effluent standards, regulating the total discharge from the WWTPs, the Rya WWTP in G?teborg and the Sj?lunda WWTP in Malm? will have to reduce the impact of primary effluent overflow. Separate, high rate, precipitation processes operated only during high flow conditions have been investigated in pilot units at the two WWTPs. Precipitation in existing primary settlers operated at a surface loading of 3.75 m/h removed phosphorus to 0.35 mg/l. The Actiflo process was also shown to remove suspended solids and phosphorus well. BOD was reduced by 50-60%. With such processes the overall effluent concentrations from the plants can be reduced significantly. Key upgrading features are small footprints, short start up time and high efficiency.  相似文献   

17.
In wastewater treatment, micro- and ultra-filtration membranes are used for the separation of the activated sludge (biomass) from the treated water. This offers the advantages of a complete removal of solids and bacteria, as well as most of the viruses, namely those attached to the suspended solids. Compared to the conventional activated sludge process (CAS) this technology allows a much higher biomass concentration (MLSS) whereby the reactor volume and the footprint decreases. With increasing MLSS, the viscosity of the sludge increases, which leads to reduced oxygen transfer rates. Depending on the type of membrane and membrane module, the pre-treatment has to be more sophisticated to prevent clogging and sludging of the modules. Due to fouling and scaling, the flux through the membranes will decrease with time. The decrease depends on the water quality as well as on the measurements taken to minimize fouling. Mainly, three strategies are available: lowering the flux, increasing the "crossflow" and cleaning of the membranes. Different strategies including backwash and chemical cleaning "in situ", "on air" and "ex situ" can be applied. It has been proven more effective to apply preventive regular cleaning. Besides the energy demand for oxygen supply--which is typically in the range of 0.3 kWh/m3 for municipal wastewater--the energy for fouling prevention is substantial. Immersed membranes need approximately 0.4 to 1 kWh/m3 for the coarse bubble aeration, whereas tubular modules require 1 to 4 kWh/m3 pump energy. For proper design of industrial wastewater treatment, the verification of applicability and the development of adequate cleaning strategies, it is a precondition to run pilot tests for a sufficient period of time with the wastewater to be treated. More than 100 industrial wastewater treatment membrane bioreactors (MBR) are in operation in Europe. Data of three case studies for a sewage sludge dewatering plant in UK (12,000 m3/d), a plant for the treatment of pharmaceutical wastewater in Germany (3600 m3/d), as well for revamping of an chemical WWTP >2000 m3/d in Italy, are given. MBRs will be used in future wherever high quality effluent is required, because of a sensitive receiving water body or due to the fact of water reuse as process water. MBRs are a perfect pre-treatment in industrial applications when further treatment with nanofiltration or reverse osmosis is considered. The technique is advanced and can be applied both in municipal and industrial wastewater treatment. Higher operational costs must be balanced by superior effluent quality.  相似文献   

18.
Effluents of wastewater treatment plants are relevant point sources for the emission of hazardous xenobiotic substances to the aquatic environment. One group of substances, which recently entered scientific and political discussions, is the group of the perfluorinated alkylated substances (PFAS). The most studied compounds from this group are perfluorooctanoic acid (PFOA) and perfluorooctane sulphonate (PFOS), which are the most important degradation products of PFAS. These two substances are known to be persistent, bioaccumulative and toxic (PBT). In the present study, eleven PFAS were investigated in effluents of municipal wastewater treatment plants (WWTP) and in industrial wastewaters. PFOS and PFOA proved to be the dominant compounds in all sampled wastewaters. Concentrations of up to 340 ng/L of PFOS and up to 220 ng/L of PFOA were observed. Besides these two compounds, perfluorohexanoic acid (PFHxA) was also present in nearly all effluents and maximum concentrations of up to 280 ng/L were measured. Only N-ethylperfluorooctane sulphonamide (N-EtPFOSA) and its degradation/metabolisation product perfluorooctane sulphonamide (PFOSA) were either detected below the limit of quantification or were not even detected at all. Beside the effluents of the municipal WWTPs, nine industrial wastewaters from six different industrial branches were also investigated. Significantly, the highest emissions or PFOS were observed from metal industry whereas paper industry showed the highest PFOA emission. Several PFAS, especially perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluorododecanoic acid (PFDoA) and PFOS are predominantly emitted from industrial sources, with concentrations being a factor of 10 higher than those observed in the municipal WWTP effluents. Perfluorodecane sulphonate (PFDS), N-Et-PFOSA and PFOSA were not detected in any of the sampled industrial point sources.  相似文献   

19.
Persistent polar pollutants (P3) are difficult to degrade in standard waste water treatment plants. As a result, they end up in the effluent and are emitted to the surface water. In some areas, this problem is aggravated through "closed loop recycling", causing concentrations of P3 in surface water to build up over time. This could cause violation of (future) EU regulations. In the P-THREE project, various alternative waste water treatment techniques are investigated regarding their effectiveness in eliminating these substances, especially membrane bioreactor treatment and advanced oxidation processes, MBR and AOP. The integrated systems analysis which is the subject of this paper assesses these techniques in a broader systems context: (1) the life-cycle of the P3, (2) the life cycle of the WWTPs, and (3) the WWTP life cycle costs.  相似文献   

20.
Two MBR pilot systems were constructed and tested in the Bali Primary WWTP. The pilot study shows that two MBR systems, i.e. the Green-MenBio system (MBR-1) and the Bio-MF system (MBR-2), can both fulfill the requirement of wastewater reclamation standard. The MBR-2 system is more economical compared with MBR-1 system. The cost of US dollars 0.10-0.16/m3 is estimated to reclaim the effluent of primary WWTP in Taiwan. The Bali Primary WWTP has the capacity of 1,320,000 cmd which is the biggest in Taiwan. The domestic wastewater of partial Taipei City and Taipei County are collected and transported to the Bali Primary WWTP. The effluent of the Bali Primary WWTP is then discharged into the ocean through two 3.8 m marine outfalls. The AO processes are installed in both MBR systems. More than 90% of the NH3-N can be removed through the AO and membrane processes. The outflow of the MBR systems (without RO) can reach the quality of COD <30 mg/l, BOD <10 mg/l, SS <5 mg/l, NH3-N <3 mg/L. The outflow of the MBR system is proposed to transport 40 km south to the Taoyuan County where four new industrial parks are to be constructed. Part of the reclaimed water is to be used on irrigation and another portion is to be sent to the industries after RO treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号