首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A strongly fluorescing 7-hydroxycoumarin (umbelliferone, U) oxidized in dilute (10 mumol/L-O, 1 mol/L) aqueous solution with CIO- or CIO- + H2O2 (but not with H2O2 alone) produces a strong chemiluminescence (CL). Light emission kinetics depends on the pH of solution (4.0-10.5) and the reaction has a low activation energy Ea = 31 +/- 2 kJ/mol (285-310 K). The spectrum covers the fluorescence of umbelliferone (400-550 nm, lambda max 460 nm). No red emission typical of 1 delta g, 1 sigma g, 1 sigma+g (O2)2 is observed either in the umbelliferone+CIO- or the umbelliferone +CIO- + H2O2 solution. The possible mechanism of CL and concomitant degradative oxidation of umbelliferone is discussed.  相似文献   

3.
OBJECTIVE: To assess the relationship between ethnicity and decision-makers expressing healthcare wishes in a group of frail older persons enrolled in the Program of All-inclusive Care for the Elderly (PACE). DESIGN: A retrospective chart review of 1193 participants in the PACE program. SETTING: Program of All-inclusive Care for the Elderly, a comprehensive managed care demonstration program serving frail older participants at 10 sites across the nation. PARTICIPANTS: A total of 1193 older adults, all of whom met state criteria for nursing home level of care. Three hundred were non-Hispanic whites, 364 were black, 156 were Hispanic, and 288 were Asian. MEASUREMENTS: Demographic characteristics of the patients and the presence or absence of an alternative decision-maker; the characteristics of alternative decision-makers included the relationship to the participant as recorded in the patient's medical record. RESULTS: Ninety-one percent of white patients expressed their own healthcare wishes in contrast to only 85% of Hispanic, 83% of Asian, and 67% of black patients. An alternative decision-maker was identified for about 15% of Asians and Hispanics and for one-third of blacks, but only about 8% of whites had an alternative decision-maker. Black and Hispanic patients were most likely to have a daughter as an alternative decision-maker, Asians were most likely to have a son, and whites patients were most likely to have a spouse as an alternative decision-maker. Blacks, particularly black men, were the most likely to have a relative other than a spouse or child as an alternative decision-maker. CONCLUSIONS: In this population, we found significant ethnic variation in the person identified to be the decision-maker in a group of frail older people. Ethnic variation reflected sociodemographic as well as cultural differences. However, there are important limitations to this study, and caution should be used in extrapolating the results to other populations or in attributing the results to ethnicity alone. An awareness of cross-cultural patterns in identified or de facto decision-makers can be significant for healthcare workers when they approach patients and their families about issues surrounding end of life decisions.  相似文献   

4.
PURPOSE: To evaluate the accuracy of spiral CT angiography in the diagnosis of central pulmonary embolism (PE). MATERIAL AND METHODS: A retrospective study was undertaken in a population of 90 patients who were evaluated with spiral CT angiography (acquisition: 12 to 24 s with or without strict apnea; injection of 90 cm3 of 12, 20 or 30% contrast material at a rate of 4 to 7 cm3, selective pulmonary angiography of each lung (n = 55) and/or ventilation-perfusion (VP) scanning (n = 35). RESULTS: Among the 55 patients evaluated with both spiral CT and angiography, central pulmonary embolism was excluded in 19 patients (34%), assessed in 29 patients (53%) whereas CT examination was considered as inconclusive in 7 patients (13%) due to interpretive difficulties at the level of obliquely oriented arteries and/or presence of hilar lymph nodes (sensitivity: 90.5%; specificity: 82.6%). With spiral CT, the finding of 95 central emboli (3 main, 61 lobar and 31 segmental) corresponded exactly to the angiographic findings; spiral CT enabled direct visualization of intraluminal filling defects (n = 95) whereas the angiographic recognition of PE was based on direct (n = 57) and indirect (n = 38) signs. Spiral CT angiography was more sensitive and specific than VP scanning. CONCLUSION: Spiral CT angiography appears as a sensitive and specific noninvasive method for the diagnosis of central PE.  相似文献   

5.
Magnetic resonance angiography (MRA) has been applied to a variety of different manifestations of cerebrovascular disease to date. Practically, the limitations of these techniques must be taken into account such that the appropriate method is applied to answer a specific clinical question and the acquisition parameters are chosen to maximise the sensitivity and specificity of the study. Based upon these results, it must be decided whether the conventional parenchymal MR and MRA evaluations are sufficient in a particular setting or whether it is necessary to commit the patient to a more traditional, invasive angiographic study for a more thorough investigation. Presently, MR angiographic studies and flow measurement techniques serve to compliment the more traditional spin-echo evaluation of patients with small aneurysms, arterial and venous occlusions, vascular malformations and in some cases of neoplastic vascular invasion. With well-trained technicians and carefully prescribed protocols, this new information and improved diagnostic sensitivity can be used routinely with only a minor increase in patient exam time.  相似文献   

6.
7.
8.
9.
RATIONALE AND OBJECTIVES: The authors investigated the enhancing effect of low-dose administration of the macromolecular, paramagnetic contrast medium gadolinium (Gd)-DTPA-polylysine (average molecular weight, 40,000-50,000 dalton [D]) compared with Gd-DTPA (molecular weight, 547 D) in time-of-flight magnetic resonance angiography of unilaterally damaged sheep lungs. MATERIALS AND METHODS: Thirteen heart-lung preparations were examined in the head coil of a 1.5-tesla imager (Magnetom SP, Siemens, Erlangen, Germany). The authors performed time-of-flight angiograms (coronal; repetition time, 35 mseconds; echo time, 6 mseconds; 20 degrees flip angle; pixel size 1.0 x 1.0 x 1.5 mm3) before and after application of the contrast agents. Gadolinium-DTPA-polylysine was used in a dose of 0.027 mmol/kg body weight while Gd-DTPA was injected in variable doses. RESULTS: After Gd-DTPA-polylysine, signal intensity increased by 118% in pulmonary arteries in healthy lungs and by 121% in damaged lungs (P < 0.001). In addition, the contrast-to-noise ratio measured between pulmonary arteries and perivascular parenchyma increased significantly (P < 0.01). On three-dimensional angiograms, two more generations of vascular branches could be detected. A dose of Gd-DTPA 6.1 times higher than the Gd-DTPA-polylysine dose was necessary to obtain the same contrast enhancing effect as Gd-DTPA-polylysine in healthy lungs. In damaged lungs, none of the administered doses of Gd-DTPA reached the average contrast enhancement of Gd-DTPA-polylysine. CONCLUSIONS: The authors' measurements demonstrate significant improvement of time-of-flight angiograms by low-dose administration of Gd-DTPA-polylysine.  相似文献   

10.
PURPOSE: To compare spiral (SCT) and electron-beam CT (EBT) for the diagnosis of pulmonary embolism (PE). MATERIALS AND METHODS: From June 1997 to June 1998 188 patients with suspected acute or chronic thromboembolism of the pulmonary arteries were examined. A total of 108 patients were scanned using SCT and 80 patients using EBT. On each scanner two different scan protocols were evaluated. RESULTS: PE was diagnosed in 38 patients using EBT and in 49 patients using SCT. Especially with EBT, isolated peripheral emboli could be confidently diagnosed. When EBT and SCT were compared for the analysis of peripheral pulmonary arteries, some paracardiac segmental and subsegmental vessels were significantly better analyzable with EB. Additional or diseases other than PE were diagnosed in 112 patients. Other diagnoses included bronchial carcinoma and aortic dissection. CONCLUSIONS: Advanced CT scanning techniques allow the highly accurate diagnosis of central and peripheral PE. Other potentially life-threatening underlying diseases are also readily recognized.  相似文献   

11.
Pulmonary arteriovenous fistula are an uncommon disorder, and are most frequently congenital, usually then associated with hereditary hemorrhagic telangectasia (Rendu-Osler-Weber disease). We present, to our knowledge, the first case of a pulmonary arteriovenous fistula detected by gadolinium-enhanced pulmonary magnetic resonance angiography and confirmed by digital subtraction pulmonary angiography in a patient where the CT scan was unremarkable.  相似文献   

12.
OBJECTIVES: This study was undertaken to investigate the relation between dietary fat composition and adiposity in adult men. SUBJECTS: A sample of 128 male subjects who participated in Phase 2 of the Québec Family Study. DESIGN: The association between adiposity and total dietary fat intake (TFI), saturated fat intake (SFA), monounsaturated fat intake (MUFA) and polyunsaturated fat intake (PUFA) was analyzed in the overall sample. A comparison of body fatness was also performed between consumers of high (4th quartile) and low amounts (1st quartile) of TFI, SFA, MUFA and PUFA. RESULTS: Significant positive correlations were found between the percentage of dietary energy as total fat and body fatness. Men in the upper quartile of TFI displayed significantly more adiposity than those in the lower quartile. Significant differences were also observed when quartiles were established using SFA and MUFA. However, higher intakes of PUFA had no statistical effects on adiposity. CONCLUSION: These results confirm the notion that high fat diets might lead over time to excess body fat deposition. SFA and MUFA intake also seem to be predictors of actual adiposity markers while high PUFA intake seems to exert no effect on these markers.  相似文献   

13.
Contrast enhanced (CE) magnetic resonance angiography (MRA) provides high resolution angiograms within 20-40 sec. The technique is based on the acquisition of heavily T1-weighted three-dimensional (3D) gradient-echo data sets (FISP) with ultrashort echo-(< 2ms) and repetition times (< 5 ms) during arterial phase of an intravenously injected bolus of a T1-shortening agent such as Gd-DTPA. For MR-angiography of abdominal vessels CE-MRA is better suited than "time-of flight" (TOF) and phase-contrast (PC) MRA because motional artifacts can be obviated with breath-held acquisitions. We have optimised the technique and evaluated its potential for angiography of the abdominal aorta and its branches as well as the portal vein and its tributaries. Whilst CE-MRA provides reliable diagnostic accuracy in the aorta and the proximal sections of its branches, small peripheral arteries cannot be assessed accurately. The portal vein and its tributaries can often be depicted better with CE-MRA than with conventional angiography but, like conventional angiography, CE-MRA is hampered by slow and reversed flow, conditions under which TOF or "true FISP" MRA may perform bst. We have also investigated FLASH-echo-planar imaging (EPI) hybrid techniques, a further technical development which due to shorter acquisition times of 12-15 sec. allows semi-dynamic imaging of the arterial and venous phase and provide better vessel contrast due to the use of fat-suppression.  相似文献   

14.
Sedoheptulose-1,7-bisphosphatase (SBPase) is an enzyme unique to photosynthetic organisms and has a key role in regulating the photosynthetic Calvin cycle through which nearly all carbon enters the biosphere. This makes SBPase an appropriate target for intensive study. We have expressed wheat SBPase in Escherichia coli either with or without an N-terminal polyhistidine tag. The identity of the recombinant SBPases was confirmed by SDS-PAGE analysis and immunological detection with a specific antibody. Recombinant SBPase with a polyhistidine tag (His-SBPase) was obtained in soluble, active form and purified by one-step metal-chelate chromatography. Like the native enzyme, recombinant His-SBPase was specific for the substrate sedoheptulose-1,7-bisphosphate and required the presence of a reducing agent for activity. Polyclonal antibodies were raised against recombinant SBPase and were then used to determine relative levels of the enzyme in plant extracts. The availability of large amounts of active recombinant SBPase will also allow detailed structural studies by site-directed mutagenesis and X-ray crystallography.  相似文献   

15.
Diagnostic evaluation in the patient with suspected deep vein thrombosis (DVT) and pulmonary embolism (PE) includes a clear correlation between clinical probability, test selection and test interpretation. Real-time B-mode ultrasound with color Doppler remains the imaging technique of choice in suspected DVT. The ventilation/perfusion (V/Q) lung scan is the preferred diagnostic modality in suspected PE. The D-dimer assay may be useful in excluding PA. New diagnostic techniques, including spiral computerized tomography may further modify the diagnostic algorithm.  相似文献   

16.
17.
OBJECTIVES: This biomechanical cadaver study was performed to compare the fixation stability of a standard lateral condylar buttress plate with a similar condylar buttress plate with the distal screws locked to the plate. Then the study was repeated with six additional matched femoral pairs to compare the locked plate with a standard 95-degree blade plate. DESIGN: Six matched pairs of mildly osteopenic femurs were selected, and each side was assigned randomly to fixation with either a standard lateral condylar buttress plate or a modified lateral condylar buttress plate with locked distal screws. The experiment was repeated with six additional matched pairs of femurs instrumented with either a modified lateral condylar buttress plate with locked distal screws or a standard 95-degree blade plate. INTERVENTION: The femurs were instrumented, and a gap osteotomy was created at the distal femoral metaphysis. The instrumented femurs were then mechanically tested in axial compression and bending/torsional loading to determine fixation stability; then they were loaded at 1,000 newtons for 10(5) cycles and retested for stability. MAIN OUTCOME MEASUREMENT: The displacement across the osteotomy gap at 100-newton and 1,000-newton axial loads was measured directly for each specimen before and after cycling. In addition, resistance to displacement in bending/torsional loading (newtons/centimeter) was determined from load/displacement curves, before and after cycling. RESULTS: The locked buttress plate provided significantly greater fixation stability than the standard plate both before and after cycling in axial loading. The locked buttress plate also proved significantly more stable in axial loading than the blade plate both before and after cycling. CONCLUSION: A condylar buttress plate with locked screws is a valid concept for improving fixation stability.  相似文献   

18.
19.
Magnetic resonance angiography (MRA) has become a useful non-invasive imaging technique for the assessment of vascular disease. Due to limitations such as respiratory motion artefacts, saturations problems, and long acquisition times, applications of MRA in the thorax have largely been restricted to imaging of the aorta. The recent introduction of breath-hold three-dimensional (3D) contrast-enhanced MRA promises not only to enhance conventional MR protocols for aortic imaging, but to extend the clinical indications of MRI to diseases affecting other vascular structures of the thorax, most notably the pulmonary arteries. This article describes the technical aspects of contrast-enhanced 3D MRA and reviews existing and potential future clinical applications.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号