首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
FLAP is a new method for localized photo‐labelling and subsequent tracking of specific molecules within living cells. It is simple in principle, easy to implement and has a wide potential application. The molecule to be located carries two fluorophores: one to be photobleached and the other to act as a reference label. Unlike the related methods of fluorescence recovery after photobleaching (FRAP) and fluorescence loss in photobleaching (FLIP), the use of a reference fluorophore permits the distribution of the photo‐labelled molecules themselves to be tracked by simple image differencing. In effect, FLAP is therefore comparable with methods of photoactivation. Its chief advantage over the method of caged fluorescent probes is that it can be used to track chimaeric fluorescent proteins directly expressed by the cells. Although methods are being developed to track fluorescent proteins by direct photoactivation, these still have serious drawbacks. In order to demonstrate FLAP, we have used nuclear microinjection of cDNA fusion constructs of β‐actin with yellow (YFP) and cyan (CFP) fluorescent proteins to follow both the fast relocation dynamics of monomeric (globular) G‐actin and the much slower dynamics of filamentous F‐actin simultaneously in living cells.  相似文献   

2.
Fluorescence recovery after photobleaching (FRAP) measurements offer an important tool for analyzing diffusion and binding processes. Confocal scanning laser microscopes that are used in FRAP experiments bleach regions with a radially Gaussian distributed profile. Previous attempts to derive analytical expressions in the case of processes governed by fast diffusion have overlooked the characteristics of the instruments used to perform FRAP measurements and therefore led to approximating solutions. In the present paper, bleaching laser beam characteristics are incorporated into an improved model to provide a more rigorous and accurate method. The proposed model simulates binding inside bounded regions, and it leads to FRAP curves that depend on the on and off rates that can be employed to determine the rate constants. It can be used in conjunction with experimental data acquired with confocal scanning laser microscopes to investigate the biophysical properties of proteins in living cells. The model aims to improve the accuracy when determining rate constants by taking into account a more realistic scenario of the light-matter interaction.  相似文献   

3.
A procedure for a systematic evaluation of fluorescence recovery after photo‐bleaching (FRAP) data is presented that allows one to determine distributions of diffusion coefficients. The method provides a straightforward and calibration‐free way to quantify multiple diffusion processes when FRAP is measured as a function of time and space by means of confocal laser scanning microscopy. It is verified utilizing FRAP experiments on mixtures of differently sized fluorescent micro‐spheres as realizations of discrete D distributions.  相似文献   

4.
Photomanipulation (photobleaching, photoactivation, or photoconversion) is an essential tool in fluorescence microscopy. Fluorescence recovery after photobleaching (FRAP) is commonly used for the determination of lateral diffusion constants of membrane proteins, and can be conveniently implemented in confocal laser scanning microscopy (CLSM). Such determinations provide important information on molecular dynamics in live cells. However, the CLSM platform is inherently limited for FRAP because of its inflexible raster (spot) scanning format. We have implemented FRAP and photoactivation protocols using structured illumination and detection in a programmable array microscope (PAM). The patterns are arbitrary in number and shape, dynamic and adjustable to and by the sample characteristics. We have used multispot PAM–FRAP to measure the lateral diffusion of the erbB3 (HER3) receptor tyrosine kinase labeled by fusion with mCitrine on untreated cells and after treatment with reagents that perturb the cytoskeleton or plasma membrane or activate coexpressed erbB1 (HER1, the EGF receptor EGFR). We also show the versatility of the PAM for photoactivation in arbitrary regions of interest, in cells expressing erbB3 fused with the photoconvertible fluorescent protein dronpa. dronpa. Microsc. Res. Tech., 2009. © 2009 Wiley-Liss, Inc.  相似文献   

5.
Bleach rate imaging on a (cooled) CCD can be easily achieved using a confocal microscope with bilateral scanning and detection coupled to a workstation; it is as easy as acquiring regular fluorescence images. Several analysis and display methods for bleach rate imaging are presented such as the bleach map (and its inverse) and a matrix-based decomposition method for multi-labelled specimens based on the bleach rate differences between the dyes used. With these tools, bleach-rate-based imaging can become a viable alternative to multiple labelling techniques for component identification in fluorescent specimens.  相似文献   

6.
We present three novel reproducible methodologies for the quantification of changes in actin organization from microscope images. Striation and integrative analysis were devised for the investigation of trans-cellular filaments and F-actin localization, respectively, in response to physiological or mechanical actin-modulatory conditions. Additionally, the Parker-Qusous (PQ) formula was developed as a measure of total quantity of F-actin, independent of cell volume changes, whereby fluorescence intensity was divided by the cube root of cell volume, squared. Values obtained were quantified in Mauricean Units (Mu; pixel/μm(3)). Upon isolation, there was a 49% decrease in total F-actin fluorescence from 1.91 ± 0.16 pixel/μm(3) (Mu) to 0.95 ± 0.55 Mu, whereas upon culture, an apparent increase in total fluorescence was deemed insignificant due to an increase in average cell volume, with a rise, however, in striation units (StU) from 1 ± 1 to 5 ± 1 StU/cell, and a decrease in percentage cortical fluorescence to 30.45% ± 1.52% (P = 7.8 × 10(-5)). Freshly isolated chondrocytes exhibited a decrease in total F-actin fluorescence to 0.61 ± 0.05 Mu and 0.32 ± 0.02 Mu, 10 min posthypertonic and hypotonic challenges, respectively. Regulatory volume decrease was inhibited in the presence of REV5901 with maintenance of actin levels at 1.15 Mu. Following mechanical impact in situ, there was a reduction in total F-actin fluorescence to 0.95 ± 0.08 Mu and 0.74 ± 0.06 Mu under isotonic and hypotonic conditions, respectively, but not under hypertonic conditions. We report simple methodologies for quantification of changes in actin organization, which will further our understanding of the role of actin in various cellular stress responses. These techniques can be applied to better quantify changes in localization of various proteins using fluorescent labeling.  相似文献   

7.
We have developed an integrated spectroscopy system combining total internal reflection fluorescence microscopy imaging with confocal single-molecule fluorescence spectroscopy for two-dimensional interfaces. This spectroscopy approach is capable of both multiple molecules simultaneously sampling and in situ confocal fluorescence dynamics analyses of individual molecules of interest. We have demonstrated the calibration with fluorescent microspheres, and carried out single-molecule spectroscopy measurements. This integrated single-molecule spectroscopy is powerful in studies of single molecule dynamics at interfaces of biological and chemical systems.  相似文献   

8.
There are a variety of microscope technologies available to image plant cortical microtubule arrays. These can be applied specifically to investigate direct questions relating to array function, ultrastructure or dynamics. Immunocytochemistry combined with confocal laser scanning microscopy provides low resolution "snapshots" of cortical microtubule arrays at the time of fixation whereas live cell imaging of fluorescent fusion proteins highlights the dynamic characteristics of the arrays. High-resolution scanning electron microscopy provides surface detail about the individual microtubules that form cortical microtubule arrays and can also resolve cellulose microfibrils that form the innermost layer of the cell wall. Transmission electron microscopy of the arrays in cross section can be used to examine links between microtubules and the plasma membrane and, combined with electron tomography, has the potential to provide a complete picture of how individual microtubules are spatially organized within the cortical cytoplasm. Combining these high-resolution imaging techniques with the expression of fluorescent cytoskeletal fusion proteins in live cells using correlative microscopy procedures will usher in an radical change in our understanding of the molecular dynamics that underpin the organization and function of the cytoskeleton.  相似文献   

9.
The diffusion coefficient, D, and the proportion of mobile molecules, p, is measured for a fluorescently labeled polyelectrolyte in a multilayer film using fluorescence recovery after photobleaching (FRAP). The film was composed of poly(L-lysine) (PLL) and hyaluronan (HA). The labeled polyelectrolyte (PLL(FITC)) was either deposited on top of the film or embedded within it. A circular area of diameter approximately 60 microm was bleached using a confocal laser scanning microscope. Because molecules do already diffuse during the bleaching step, the initial light intensity profile is not characteristic of a uniformly bleached circular area. A formalism is developed in which a simple mathematical representation of a measured profile serves as starting profile. This radial distribution is introduced in the equation describing the time evolution of the labeled molecule concentration under the hypothesis that the recovery results from pure, two-dimensional Brownian diffusion of the mobile molecules according to Fick's law. The analysis of a series of images taken at successive times after bleaching (up to approximately one hour) leads to estimates of D of the order of 0.2 microm(2) s(-1) for labeled molecules deposited on top of the film and a 5-fold smaller value for the molecules embedded in the film. However, p is remarkably insensitive to the position in the multilayer architecture (p approximately 0.40).  相似文献   

10.
Multiphoton excitation was originally projected to improve live cell fluorescence imaging by minimizing photobleaching effects outside the focal plane, yet reports suggest that photobleaching within the focal plane is actually worse than with one photon excitation. We confirm that when imaging enhanced green fluorescent protein, photobleaching is indeed more acute within the multiphoton excitation volume, so that whilst fluorescence increases as predicted with the square of the excitation power, photobleaching rates increase with a higher order relationship. Crucially however, multiphoton excitation also affords unique opportunities for substantial improvements to fluorescence detection. By using a Pockels cell to minimize exposure of the specimen together with multiple nondescanned detectors we show quantitatively that for any particular bleach rate multiphoton excitation produces significantly more signal than one photon excitation confocal microscopy in high resolution Z‐axis sectioning of thin samples. Both modifications are readily implemented on a commercial multiphoton microscope system.  相似文献   

11.
Accurate preservation of microtubule and actin microfilament arrays is crucial for investigating their roles in plant cell development. Aldehyde fixatives such as paraformaldehyde or glutaraldehyde preserve cortical microtubule arrays but, unless actin microfilaments are stabilized with drugs such as m-maleimidobenzoyl N-hydroxysuccinimide ester (MBS), ethylene glycol bis[sulfosuccinimidylsuccinate] (sulfo-EGS) or phalloidin, their arrays are often poorly preserved. Cryofixation, used primarily for electron microscopy, preserves actin microfilaments well but is used rarely to fix plant cells for optical microscopy. We developed a novel whole-mount cryofixation method to preserve microtubule and microfilament arrays within Tradescantia virginiana leaf epidermal cells for investigation using confocal microscopy. Cortical microtubule arrays were often oriented in different directions on the internal and external faces of the epidermal cells. A number of arrays were aligned in several directions, parallel to microtubules of neighbouring cells. Actin microfilaments were particularly well preserved possibly due to the speed with which they were immobilized. No transverse cortical microfilament arrays were observed. On occasion, we observed co-aligned microfilament and microtubule bundles lying adjacent to the plasma membrane and positioned side by side suggesting a potential direct interaction between the cytoskeletal filaments at these locations. Cryofixation is therefore a valuable tool to investigate the interactions between cytoskeletal arrays in plant cells using confocal microscopy.  相似文献   

12.
13.
The relative spatial distribution of proteins was investigated with immunofluorescent methods by confocal laser scanning microscopy and digital image restoration. For confocal data sets recorded with a voxel dimension of 50 × 50 × 150 nm noise and blur can be decreased and the resolution in the z-axis increased by applying the maximum likelihood estimation algorithm of the Huygens software. This approach was successfully applied to the study of tight and adherens junctions in relation to the actin cytoskeleton in Madin Darby Canine Kidney cells. Colocalization analysis was done for pairs of probes using a histogram-based method. F-actin, occludin, zonula occludens 1, and E-cadherin were included in the study. Double-labeled preparations were used. The combination of deconvolution with the colocalization of confocal data sets offers a powerful tool to investigate the spatial arrangement of proteins.  相似文献   

14.
The diffusion coefficient as well as the dimensionality of the diffusion process can be determined by straightforward and facile data analysis, when fluorescence recovery after photobleaching (FRAP) is measured as a function of time and space by means of confocal laser scanning microscopy. Experiments representing one-dimensional diffusion from a plane source or two-dimensional diffusion from a line source are readily realized. In the data analysis, the deviations of the actual initial conditions from ideal models are consistently taken into account, so that no calibration measurements are needed. The method is applied to FRAP experiments on solutions of Rhodamine B in glycerol and aqueous suspensions of polymethyl methacrylate microspheres.  相似文献   

15.
Raster image correlation spectroscopy (RICS) is a new and novel technique for measuring molecular dynamics and concentrations from fluorescence confocal images. The RICS technique extracts information about molecular dynamics and concentrations from images of living cells taken on commercial confocal systems. Here we develop guidelines for performing the RICS analysis on an analogue commercial laser scanning confocal microscope. Guidelines for typical instrument settings, image acquisition settings and analogue detector characterization are presented. Using appropriate instrument/acquisition parameters, diffusion coefficients and concentrations can be determined, even for highly dynamic dye molecules in solution. Standard curves presented herein demonstrate the ability to detect protein concentrations as low as ~ 2 nM. Additionally, cellular measurements give accurate values for the diffusion of paxillin‐enhanced‐green fluorescent protein (EGFP), an adhesion adaptor molecule, in the cytosol of the cell and also show slower paxillin dynamics near adhesions where paxillin interacts with immobile adhesion components. Methods are presented to account for bright immobile structures within the cell that dominate spatial correlation functions; allowing the extraction of fast protein dynamics within and near these structures. A running average algorithm is also presented to address slow cellular movement or movement of cellular features such as adhesions. Finally, methods to determine protein concentration in the presence of immobile structures within the cell are presented. A table is presented giving guidelines for instrument and imaging setting when performing RICS on the Olympus FV300 confocal and these guidelines are a starting point for performing the analysis on other commercial confocal systems.  相似文献   

16.
Measurement of mobilities of species in liquid systems is of great importance for understanding a number of dynamic phenomena. A well known method for measuring mobilities driven by diffusion is fluorescence photobleaching recovery (FPR), also known as fluorescence recovery after photobleaching (FRAP). New FPR recovery equations for three-dimensional (3-D) apertured scanning using a Gaussian approximation for the axial beam profile have been successfully developed and found to provide a solid basis for extraction of the lateral diffusion coefficient from confocal scanning light microscopy (CSLM)-FPR experimental data. The 2-D diffusion coefficients of fluorescent species can be successfully measured by FPR in the CSLM, which has the great advantage that bleaching can be targeted at a well-defined volume element in bulk samples. Two-dimensional diffusion coefficients of 45-nm latex spheres, of FITC molecules and of a 2·45-nm protein-FITC complex in water-glycerol mixtures, measured by FPR in the CSLM, are in close agreement with those calculated from the size of the diffusing species and viscosity of the medium. Diffusion coefficients as high as 2 times 10?6 cm2/s can be measured.  相似文献   

17.
We report three-dimensional (3D) microscopy with nearly isotropic resolution in the λ/5 − λ/10 range. Our approach combines 4Pi-confocal two-photon fluorescence microscopy with image restoration. The 3D resolution is demonstrated with densely clustered beads as well as with F-actin fibers in mouse fibroblast cells. A comparison with unrestored two-photon confocal images reveals a total reduction of the uncertainty volume up to a factor of 15.  相似文献   

18.
The fluorescence photobleaching method has been widely used to study molecular transport in single living cells and other microsystems while confocal microscopy has opened new avenues to high-resolution, three-dimensional imaging. A new technique, scanning microphotolysis (Scamp), combines the potential of photobleaching, beam scanning and confocal imaging. A confocal scanning laser microscope was equipped with a sufficiently powerful laser and a novel device, the ‘Scamper’. This consisted essentially of a filter changer, an acousto-optical modulator (AOM) and a computer. The computer was programmed to activate the AOM during scanning according to a freely defined image mask. As a result almost any desired pattern could be bleached (‘written’) into fluorescent samples at high definition and then imaged (‘read’) at non-bleaching conditions, employing full confocal resolution. Furthermore, molecular transport could be followed by imaging the dissipation of bleach patterns. Experiments with living cells concerning dynamic processes in cytoskeletal filaments and the lateral mobility of membrane lipids suggest a wide range of potential biological applications. Thus, Scamp offers new possibilities for the optical manipulation and analysis of both technical and biological microsystems.  相似文献   

19.
Fluorescent speckle microscopy (FSM) uses low levels of fluorescent proteins to create fluorescent speckles on cytoskeletal polymers in high‐resolution fluorescence images of living cells. The dynamics of speckles over time encode subunit turnover and motion of the cytoskeletal polymers. We sought to improve on current FSM technology by first expanding it to study the dynamics of a non‐polymeric macromolecular assembly, using focal adhesions as a test case, and second, to exploit for FSM the high contrast afforded by total internal reflection fluorescence microscopy (TIR‐FM). Here, we first demonstrate that low levels of expression of a green fluorescent protein (GFP) conjugate of the focal adhesion protein, vinculin, results in clusters of fluorescent vinculin speckles on the ventral cell surface, which by immunofluorescence labelling of total vinculin correspond to sparse labelling of dense focal adhesion structures. This demonstrates that the FSM principle can be applied to study focal adhesions. We then use both GFP‐vinculin expression and microinjected fluorescently labelled purified actin to compare quantitatively the speckle signal in FSM images of focal adhesions and the actin cytoskeleton in living cells by TIR‐FM and wide‐field epifluorescence microscopy. We use quantitative FSM image analysis software to define two new parameters for analysing FSM signal features that we can extract automatically: speckle modulation and speckle detectability. Our analysis shows that TIR‐FSM affords major improvements in these parameters compared with wide‐field epifluorescence FSM. Finally, we find that use of a crippled eukaryotic expression promoter for driving low‐level GFP‐fusion protein expression is a useful tool for FSM imaging. When used in time‐lapse mode, TIR‐FSM of actin and GFP‐conjugated focal adhesion proteins will allow quantification of molecular dynamics within interesting macromolecular assemblies at the ventral surface of living cells.  相似文献   

20.
In this paper, we experimentally demonstrated a two-channel frequency division multiplexing confocal fluorescence microscopy system using a UV laser as the excitation source. In our two-channel frequency division multiplexing confocal fluorescence system, the incoming laser beam was divided into two beams and each beam was modulated with an individual carrier frequency. These two laser beams were then spatially combined with a small angle and focused into two diffraction-limited spots on the targeted cell (rat neural cell) surface to generate fluorescent signal. As a result, the fluorescent signals from two spots of the rat neural cell surface can be demodulated and distinguished during data processing. Furthermore, a quantitative analysis on the cross-talk among different frequencies was provided as well. The experimental results confirm that the two-channel frequency division multiplexing confocal fluorescence technology can not only maintain the high spatial resolution, but also realize the multiple points detection simultaneously with high temporal resolution (within millisecond level range), which benefits the dynamic studies of living biological cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号