首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Observed peptide gas-phase fragmentation patterns are a complex function of many variables. To systematically probe this phenomenon, an array of 40 peptides was synthesized for study. The array of sequences was designed to hold certain variables (peptide length) constant and randomize or balance others (peptide amino acid distribution and position). A high-quality tandem mass spectrometry (MS/MS) data set was acquired for each peptide for all observed charge states on multiple MS instruments, quadrupole-time-of-flight and quadrupole ion trap. The data were analyzed as a function of total charge state and number of mobile protons. Previously known dissociation trends were observed, validating our approach. In addition, the general influence of basic amino acids on dissociation could be determined because, in contrast to the more widely studied tryptic peptides, the amino acids H, K, and R were positionally distributed. Interestingly, our results suggest that cleavage at all basic amino acids is suppressed when a mobile proton is available. Cleavage at H becomes favored only under conditions where a partially mobile proton is present, a caveat to the previously reported trend of enhanced cleavage at H. Finally, all acquired data were used as a benchmark to determine how well these sequences would have been identified in a database search using a common algorithm, Mascot.  相似文献   

2.
An electrospray ionization, dual gate, ion mobility, quadrupole ion trap mass spectrometer (ESI-DG-IM-QIT-MS) was constructed and evaluated for its ability to select mobility-filtered ions prior to mass analysis. While modification of the common signal-averaged ion mobility experiment was required, no modifications to the QIT were necessary. The dual gate scanning mode of operation was used to acquire mobility spectra, whereas the single mobility monitoring experiment selectively filtered ions for concentration and subsequent fragmentation within the QIT. Ion mobility separation of positively charged peptides and negatively charged carbohydrates, followed by MS fragmentation, was demonstrated. For a 1-min acquisition time, it was possible to obtain complete de novo sequence information for the examined peptides. Fragmentation of the negative carbohydrate chlorine adducts yielded ions characteristic of cross-ring and glycosidic bond cleavage. Previous unions of atmospheric pressure ion mobility and mass spectrometry have been limited in their ability to reproducibly obtain MSn data for mobility separation ions. The union of high-pressure ion mobility with quadrupole ion trap mass spectrometry presents the unique opportunity to obtain more detailed information regarding the chemistries of gas-phase ions.  相似文献   

3.
A combined electrodynamic ion funnel and ion trap coupled to an orthogonal acceleration (oa)-time-of-flight mass spectrometer was developed and characterized. The ion trap was incorporated through the use of added terminal electrodynamic ion funnel electrodes enabling control over the axial dc gradient in the trap section. The ion trap operates efficiently at a pressure of approximately 1 Torr, and measurements indicate a maximum charge capacity of approximately 3 x 10(7) charges. An order of magnitude increase in sensitivity was observed in the analysis of low concentration peptides mixtures with orthogonal acceleration (oa)-time-of-flight mass spectrometry (oa-TOF MS) in the trapping mode as compared to the continuous regime. A signal increase in the trapping mode was accompanied by reduction in the chemical background, due to more efficient desolvation of, for example, solvent related clusters. Controlling the ion trap ejection time was found to result in efficient removal of singly charged species and improving signal-to-noise ratio (S/N) for the multiply charged analytes.  相似文献   

4.
Ion mobility spectrometry (IMS) coupled to orthogonal time-of-flight mass spectrometry (TOF) has shown significant promise for the characterization of complex biological mixtures. The enormous complexity of biological samples (e.g., from proteomics) and the need for both biological and technical analysis replicates imposes major challenges for multidimensional separation platforms with regard to both sensitivity and sample throughput. A major potential attraction of the IMS-TOF MS platform is separation speeds exceeding that of conventional condensed-phase separations by orders of magnitude. Known limitations of the IMS-TOF MS platforms that presently mitigate this attraction include the need for extensive signal averaging due to factors that include significant ion losses in the IMS-TOF interface and an ion utilization efficiency of less than approximately 1% with continuous ion sources (e.g., ESI). We have developed a new multiplexed ESI-IMS-TOF mass spectrometer that enables lossless ion transmission through the IMS-TOF as well as a utilization efficiency of >50% for ions from the ESI source. Initial results with a mixture of peptides show a approximately 10-fold increase in signal-to-noise ratio with the multiplexed approach compared to a signal averaging approach, with no reduction in either IMS or TOF MS resolution.  相似文献   

5.
Ion mobility spectrometry-time-of-flight mass spectrometry (IMS-TOFMS) has been increasingly used in analysis of complex biological samples. A major challenge is to transform IMS-TOFMS to a high-sensitivity, high-throughput platform, for example, for proteomics applications. In this work, we have developed and integrated three advanced technologies, including efficient ion accumulation in an ion funnel trap prior to IMS separation, multiplexing (MP) of ion packet introduction into the IMS drift tube, and signal detection with an analog-to-digital converter, into the IMS-TOFMS system for the high-throughput analysis of highly complex proteolytic digests of, for example, blood plasma. To better address variable sample complexity, we have developed and rigorously evaluated a novel dynamic MP approach that ensures correlation of the analyzer performance with an ion source function and provides the improved dynamic range and sensitivity throughout the experiment. The MP IMS-TOFMS instrument has been shown to reliably detect peptides at a concentration of 1 nM in the presence of a highly complex matrix, as well as to provide a 3 orders of magnitude dynamic range and a mass measurement accuracy of better than 5 ppm. When matched against human blood plasma database, the detected IMS-TOF features were found to yield approximately 700 unique peptide identifications at a false discovery rate (FDR) of approximately 7.5%. Accounting for IMS information gave rise to a projected FDR of approximately 4%. Signal reproducibility was found to be greater than 80%, while the variations in the number of unique peptide identifications were <15%. A single sample analysis was completed in 15 min that constitutes almost 1 order of magnitude improvement compared to a more conventional LC-MS approach.  相似文献   

6.
Broad-band nondestructive ion detection is achieved in a quadrupole ion trap mass spectrometer by impulsive excitation of a collection of trapped ions of different masses and recording of ion image currents induced on a small detector electrode embedded in but isolated from the adjacent end cap electrode. The image currents are directly measured using a simple differential preamplifier, filter, and amplifier combination and then Fourier analyzed to obtain broad-band frequency domain spectra characteristic of the sample ions. The use of the detector electrode provides a significant reduction in capacitive coupling with the ring electrode. This minimizes coupling of the rf drive signal, which can saturate the front-end stage of the detection circuit and prevent measurement of the relatively weaker ion image currents. Although impulsive excitation is preferred due to its broad-band characteristics and simplicity of use, results are also given for narrow-band ac and broad-band SWIFT (stored wave-form inverse Fourier transform) excitation. Data using argon, acetophenone, and n-butylbenzene show that a resolution of better than 1000 is obtained with a detection bandwidth of 400 kHz. An advantage of nondestructive ion detection is the ability to measure a single-ion population multiple times. This is demonstrated using argon as the sample gas with an average remeasurement efficiency of >90%. Tandem mass spectrometry experiments using a population of acetophenone ions are also shown.  相似文献   

7.
Nie Z  Cui F  Tzeng YK  Chang HC  Chu M  Lin HC  Chen CH  Lin HH  Yu AL 《Analytical chemistry》2007,79(19):7401-7407
Herein, we report an application of charge-detection quadrupole ion trap mass spectrometry to the measurement of total dry masses of mammalian and poultry erythrocytes evaporated/ionized by laser-induced acoustic desorption. The method is rapid and widely applicable. Eight different types of red blood cells (RBCs) have been successfully analyzed, including those of human, goat, cow, mouse, pig, and chicken. The measured mean masses (weights per corpuscle) range from 0.58 x 10(13) Da (9.6 pg) of goat RBCs to 2.80 x 10(13) Da (46.5 pg) of chicken RBCs. The total dry weights determined for human RBCs from a healthy male adult, a patient with iron-deficiency anemia, and a patient with thalassemia are 34.8, 28.8, and 20.6 pg, respectively. These weights, except that of thalassemia, are all approximately 10% higher than their corresponding mean corpuscular hemoglobin values determined by a commercial automated hematology analyzer. The mass distribution profiles of the cells are all near-Gaussian, with a standard deviation of 15% for the normal human RBCs. The deviation increases significantly to 20% for RBCs with thalassemia characteristics and 27% for RBCs with iron-deficiency anemia characteristics. All the observations are in accord with their corresponding mean corpuscular volume measurements, indicating an increase in anisocytosis (variation in RBC size) in the anemic samples. Our results suggest a broad and promising application of this new technology to high-speed mass analysis of RBCs and other biological whole cells as well.  相似文献   

8.
Due to the inherently low duty cycle of ion mobility spectrometry (IMS) experiments that sample from continuous ion sources, a range of experimental advances have been developed to maximize ion utilization efficiency. The use of ion trapping and accumulation approaches prior to the ion mobility drift tube has demonstrated significant gains over discrete sampling from continuous sources but have traditionally relied upon a signal averaging (SA) to attain analytically useful signal-to-noise ratios (SNR). Multiplexed (MP) techniques based upon the Hadamard transform offer an alternative experimental approach by which ion utilization efficiency can be elevated from approximately 1 to approximately 50%. Recently, our research group demonstrated a unique multiplexed ion mobility time-of-flight (MP-IMS-TOF) approach that incorporates ion trapping and can extend ion utilization efficiency beyond 50%. However, the spectral reconstruction of the multiplexed signal using this experiment approach requires the use of sample-specific weighting designs. Such general weighting designs have been shown to significantly enhance ion utilization efficiency using this MP technique, but cannot be universally applied. By modifying both the ion trapping and the pseudorandom sequence (PRS) used for the MP experiment, we have eliminated the need for complex weighting matrices. For both simple and complex mixtures, SNR enhancements of up to 13 were routinely observed as compared to the SA-IMS-TOF approach. In addition, this new class of PRS provides a 2-fold enhancement in the number of ion gate pulses per unit time compared to the traditional HT-IMS experiment.  相似文献   

9.
A new ion mobility/time-of-flight mass spectrometer employing a high-pressure MALDI source has been designed and tested. The prototype instrument operates at a source/drift cell pressure of 1-10 Torr helium, resulting in a mobility resolution of approximately 25. A small time-of-flight mass spectrometer (20 cm) with a mass resolution of up to 200 has been attached to the drift cell to identify (in terms of mass-to-charge ratio) the separated ions. A simple tripeptide mixture has been separated in the drift tube and mass identified as singly protonated species. The ability to separate peptide mixtures, e.g., tryptic digest of a protein, is illustrated and compared to results obtained on a high-vacuum time-of-flight instrument.  相似文献   

10.
Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of a TOF MS instrument with improved sensitivity equipped with an electrodynamic ion funnel trap (IFT) that employs an automated gain control (AGC) capability. The IFT-TOF MS was coupled to a reversed-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode.  相似文献   

11.
Electrospray ionization combined with ion/ion reactions in a quadrupole ion trap can be used for the direct analysis of oligonucleotide mixtures. Elements to the success of this approach include factors related to ionization, ion/ion reactions, and mass analysis. This paper deals with issues regarding the ion polarity combination, viz., positive oligonucleotides/negative charge-transfer agent versus negative oligonucleotides/positive charge-transfer agent. Anions derived from perfluorocarbons appear to be directly applicable to mixtures of positive ions derived from electrospray of oligonucleotides, in direct analogy with positive protein ions. Conditions for forming positive oligonucleotide ions devoid of adducts were more difficult to establish than for forming relatively clean negative oligonucleotide ions. A new approach for manipulating negative ion charge states in the ion trap is described and is based on use of the electric field of the positive charge-transfer agent for storage of high-mass negative ions formed during the ion/ion reaction period. Oxygen cations are shown to be acceptable for charge-state manipulation of mixed-base oligomers but induce fragmentation in polyadenylate homopolymers. Protonated isobutylene (C4H9+), on the other hand, is shown to induce significantly less fragmentation of polyadenylate homopolymers.  相似文献   

12.
We present a novel, hybrid ion trap/time-of-flight mass spectrometer that is based on a planar multipole design. Compared with Paul trap/time-of-flight instruments, this design possesses the principal advantages of higher injection efficiency and more homogeneous extraction fields. We demonstrate the viability of the concept and describe the characterization of a first prototype. Ions can be injected into the trap with little mass discrimination and stored for several minutes. A resolution of over 1300 is achieved in reflectron mode, and the influence of the RF amplitude and pressure on the resolution is analyzed. We suggest several applications in which this new instrument could offer advantages over existing technology.  相似文献   

13.
We report on the application of an electrostatic ion beam trap as a mass spectrometer. The instrument is analogous to an optical resonator; ions are trapped between focusing mirrors. The storage time is limited by the residual gas pressure and reaches up to several seconds, resulting in long ion flight paths. The oscillation of ion bunches between the mirrors is monitored by nondestructive image charge detection in a field-free region and mass spectra are obtained via Fourier transform. The principle of operation is demonstrated by measuring the mass spectrum of trapped Ar+ and Xe+ particles, produced by a standard electron impact ion source. Also, mass spectra of heavier PEGnNa+ and bradykinin ions from a pulsed MALDI ion source were obtained. The long ion flight path, combined with mass-independent charge detection, makes this system particularly interesting for the investigation of large molecules.  相似文献   

14.
Recent advances in phosphopeptide enrichment prior to mass spectrometric analysis show genuine promise for characterization of phosphoproteomes. Tandem mass spectrometry of phosphopeptide ions, using collision-activated dissociation (CAD), often produces product ions dominated by the neutral loss of phosphoric acid. Here we describe a novel method, termed Pseudo MS(n), for phosphopeptide ion dissociation in quadrupole ion trap mass spectrometers. The method induces collisional activation of product ions, those resulting from neutral loss(es) of phosphoric acid, following activation of the precursor ion. Thus, the principal neutral loss product ions are converted into a variety of structurally informative species. Since product ions from both the original precursor activation and all subsequent neutral loss product activations are simultaneously stored, the method generates a "composite" spectrum containing fragments derived from multiple precursors. In comparison to analysis by conventional MS/MS (CAD), Pseudo MS(n) shows improved phosphopeptide ion dissociation for 7 out of 10 synthetic phosphopeptides, as judged by an automated search algorithm (TurboSEQUEST). A similar overall improvement was observed upon application of Pseudo MS(n) to peptides generated by enzymatic digestion of a single phosphoprotein. Finally, when applied to a complex phosphopeptide mixture, several phosphopeptides mis-assigned by TurboSEQUEST under the conventional CAD approach were successfully identified after analysis by Pseudo MS(n).  相似文献   

15.
A novel ion trap time-of-flight hybrid mass spectrometer (qIT-TOF MS) has been applied for peptide sequencing in proteolytic digests generated from spore mixtures of Bacilli. The method of on-probe solubilization and in situ proteolytic digestion of small, acid-soluble spore proteins has been recently developed in our laboratory, and microorganism identification in less than 20 min was accomplished. In this study, tryptic peptides were generated in situ from complex spore mixtures of B. subtilis 168, B. globigii, B. thuringiensis subs. Kurstaki, and B. cereus T, respectively. MALDI analysis of bacterial peptides generated was performed with an average mass resolving power of 6200 and a mass accuracy of up to 10 ppm using a trap-TOF tandem configuration. Precursor ions of interest were usually selected and stored in the quadrupole ion trap with their complete isotope distribution by choosing a window of +/- 2 Da. Sequence-specific information on isolated protonated peptides was gained via tandem MS experiments with an average mass resolving power of 4450 for product ion analysis, and protein and bacterial sources were identified by database searching.  相似文献   

16.
Ion mobility/time-of-flight techniques have been used to analyze mixtures of isotopically labeled peptides. The isotopic labels were generated by treatment of peptides with N-acetoxysuccinimide (or the deuterated analogue), which results in acetylation (or deuterioacetylation) of the primary amines (i.e., the N-terminus and lysine residues). The relative concentrations of a peptide in each sample are determined by comparing the peak intensities for isotopic pairs. An important consideration is that as mixtures become increasingly complex, isotopic pairs of peaks may overlap with other peaks in the mass spectrum. The influence of the acetyl and deuterioacetyl groups on the mobilities of peptides is considered. The coincidence in mobilities of isotopic pairs provides a means of distinguishing isotopic pairs from other isobaric interferences.  相似文献   

17.
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (ultra-FAIMS) combined with mass spectrometry (MS) has been applied to the analysis of standard and tryptic peptides, derived from α-1-acid glycoprotein, using electrospray and nanoelectrospray ion sources. Singly and multiply charged peptide ions were separated in the gas phase using ultra-FAIMS and detected by ion trap and time-of-flight MS. The small compensation voltage (CV) window for the transmission of singly charged ions demonstrates the ability of ultra-FAIMS-MS to generate pseudo-peptide mass fingerprints that may be used to simplify spectra and identify proteins by database searching. Multiply charged ions required a higher CV for transmission, and ions with different amino acid sequences may be separated on the basis of their differential ion mobility. A partial separation of conformers was also observed for the doubly charged ion of bradykinin. Selection on the basis of charge state and differential mobility prior to tandem mass spectrometry facilitates peptide and protein identification by allowing precursor ions to be identified with greater selectivity, thus reducing spectral complexity and enhancing MS detection.  相似文献   

18.
19.
A commercial quadrupole/time-of-flight (QqTOF) tandem mass spectrometer has been adapted for ion/ion reaction studies. To enable mutual storage of oppositely charged ions in a linear ion trap, the oscillating quadrupole field of the second quadrupole of the system (Q2) serves to store ions in the radial dimension while auxiliary radio frequency is superposed on the end lenses of Q2 during the reaction period to create barriers in the axial dimension. A pulsed dual electrospray (ESI) source is directly coupled to the instrument interface for the purpose of proton transfer reactions. Singly and doubly charged protein ions as high in mass as 66 kDa are readily formed and observed after proton-transfer reactions. For the modified instrument, the mass resolving power is approximately 8000 for a wide m/z range, and the mass accuracy is approximately 20 ppm for external calibration and approximately 5 ppm for internal calibration after ion/ion reactions. Parallel ion parking is demonstrated with a six-component protein mixture, which shows the potential application of reducing spectral complexity and concentrating certain charge states. The current system has high flexibility with respect to defining MS(n) experiments involving collision-induced dissociation (CID) and ion/ion reactions. Protein precursor and CID product masses can be determined with good accuracy, providing an attractive platform for top-down proteomics. Electron transfer dissociation ion/ion reactions are implemented by using a pulsed nano-ESI/atmospheric pressure chemical ionization dual source for ionization. The reaction between protonated peptide ions and radical anions of 1,3-dinitrobenzene formed exclusively c- and z-type fragment ions.  相似文献   

20.
Complex carbohydrates are macromolecules biosynthesized in nontemplate-type processes, bearing specific glycoepitopes involved in crucial recognition processes such as cell differentiation and cell-cell interactions. Chemical structure of single components in complex mixtures can be analyzed by mass spectrometry for determination of the size and sequence of monosaccharides involved, branching patterns, and substitution by fucose and sialic acids. For de novo identification of glycoforms in human urinome containing N- and O-free and amino acid-linked oligosaccharides, a novel method of ion mobility tandem mass spectrometry followed by computer-assisted assignment is described. Distinct patterns of ions nested specifically by their m/z values and their drift time are observed by IMS-MS. An additional peak capacity for identification of time-separated m/z values in the IMS TOF MS mode for differentiation of singly, doubly, and triply charged molecular ion species by ion mobility separation contributes to significant reduction of carbohydrate complexity in a given mass window. Profiling of glycoforms from human urinome represents a highly efficient approach for biomarker discovery and differential glycotarget identification, demonstrating potential for diagnosis of human diseases, as for congenital disorders of glycosylation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号