共查询到20条相似文献,搜索用时 109 毫秒
1.
2.
3.
4.
5.
6.
用于超高压GIS的SF_6气体绝缘套管的绝缘特性张炳江(沈阳变压器厂)1.前言目前,为了减少电站的占地面积,减少维护,保证运行安全,在现代变电站中,GIS(气体绝缘配电设备)已得到广泛应用。随着经济和技术的发展,GIS也将随着高压、超高压变电站一同发... 相似文献
7.
本文概述SF_6气体绝缘变压器的发展过程、应用情况、产品类型、结构特征、工序过程,最后就我国发展该产品提出了建议。 相似文献
8.
9.
10.
11.
采用嵌入式和GPRS技术,通过Internet和GPRS来监测电力设备中SF6绝缘气体的密度和湿度。介绍了GPRS在电力系统中的应用和相关技术,可以实现变电站的SF6电力设备中SF6气体的无线实时监测。 相似文献
12.
分析了SF6全封闭组合电器在工程实践中存在的问题,从怎样能使用户更加方便检修及维护的角度出发,对进一步提高SF6全封闭组合电器的安全性及经济性进行了探讨。 相似文献
13.
14.
15.
Hisao Inami Masaru Tatemi Toshiaki Rokunohe Makoto Hirose 《IEEJ Transactions on Electrical and Electronic Engineering》2016,11(Z2):S17-S21
Sulfur hexafluoride (SF6) is widely used in high‐voltage applications such as gas‐insulated switchgear (GIS) because of its excellent arc‐quenching properties. The main drawback of SF6 is that it is a strong greenhouse gas. Detecting small SF6 leakages in GIS is very important to protect the environment and to prevent the failure of aged GIS. To detect SF6 leakage, the gas pressure is measured and compensated by gas temperature. Usually, the temperature of the container surface is measured instead of the actual gas temperature. However, the temperature of the container surface is affected by ohmic heating of the internal components and by ambient temperature changes. These factors lead to a difference in temperature between the container surface and the gas inside the container, causing significant fluctuations in the compensated gas pressure. To remove such fluctuations, we have developed a computational fluid dynamics (CFD) transient model that simulates the correlation between the mean gas temperature inside the container and the container's surface temperature. The CFD simulation factors in the load current and ambient temperature to estimate the true temperature of the gas inside the container as accurately as possible. The mean gas temperature inside the container is obtained using CFD simulation and by measuring the surface temperature. The fluctuations in the compensated gas pressure were reduced from 2.4 to 0.48% by using the proposed algorithm based on pressure compensation with the mean gas temperature. © 2016 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc. 相似文献
16.
Masaru Tatemi Hisao Inami Toshiaki Rokunohe Makoto Hirose 《Electrical Engineering in Japan》2021,214(1):35-41
SF6 gas is widely used in power equipment such as gas insulated switchgear or gas circuit breaker. However, its global warming potential is 23,500 times higher than that of CO2. In consideration of environmental protection, detection of SF6 gas leakage with high sensitivity is necessary. The authors proposed an algorithm to accurately estimate the average gas temperature from the tank surface temperature for establishing a high‐sensitive SF6 slow leak detection technology. Since the gas temperature depends on the temperature of the conductor, the algorithm was characterized by estimating the gas temperature from the tank surface temperature and the load current. The relationship among the tank surface temperature, the gas temperature, and the current was preliminarily investigated by the use of the thermal fluid analysis and stored in the database. By use of this method, the fluctuation of the converted pressure in the basic examination test was suppressed to 20% as compared with that without considering the current. In addition, database was also created from the machine learning of field test result in substitution. In the field test, it was confirmed that the detection time of 0.5%/year slow leak could be detected in about 8 months by considering the load current. 相似文献
17.
结合江门变电站220 kV全封闭组合电器(GIS)中SF6气体水分含量超标的实例,列举GIS设备中SF6气体所含水分的主要来源,并对运行中GIS设备水分含量的测试结果进行分析,提出水分含量超标时现场的处理方法和措施. 相似文献
18.
结合江门变电站220 kV全封闭组合电器(GIS)中SF6气体水分含量超标的实例,列举GIS设备中SF6气体所含水分的主要来源,并对运行中GIS设备水分含量的测试结果进行分析,提出水分含量超标时现场的处理方法和措施。 相似文献
19.
20.
气体绝缘开关设备(GIS)相对于常规敞开式开关设备具有运行可靠性高、环境适应能力强、耐地震能力强、防污闪能力强以及占地面积和占有空间小等众多优点,近年来大量应用于电力系统。但随着电网基础建设的快速发展,GIS用量急增,厂家生产能力接近饱和,产品质量难以保证,导致基建过程中出现了大量问题,尤其是内部绝缘击穿问题,严重影响电网运行的安全。分析一起220kV变电站基建过程中GIS交流耐压试验击穿故障,通过对设备解体检查发现,该次击穿故障是由于元器件处理工艺不完善、有遗留污水所致,表明对合资企业产品均应加强监制。 相似文献