Lee Y  Ding Z  Bard AJ 《Analytical chemistry》2002,74(15):3634-3643
A technique that combines scanning electrochemical microscopy (SECM) and scanning optical microscopy (OM) was developed. Simultaneous scanning electrochemical/optical microscopy (SECM/OM) was performed by a special probe tip, which consists of an optical fiber core for light passage, surrounded by a gold ring electrode, and an outermost electrophoretic insulating sheath, with the tip attached to a tuning fork. To regulate the tip-substrate distance, either the shear force or the SECM tip current was employed as the feedback signal. The application of a quartz crystal tuning fork (32.768 kHz) for sensing shear force allowed simultaneous topographic, along with SECM and optical imaging in a constant-force mode. The capability of this technique was confirmed by obtaining simultaneously, for the first time, topographic, electrochemical, and optical images of an interdigitated array electrode. Current feedback from SECM also provided simultaneous electrochemical and optical images of relatively soft samples, such as a polycarbonate membrane filter and living diatoms in a constant-current mode. This mode should be useful in mapping the biochemical activity of a living cell.  相似文献   

2.
The fabrication and characterization of novel micropipet probes for use in scanning electrochemical microscopy (SECM) are described. These can be used to dispense small (pL) amounts of a solution while monitoring the electrochemical response at a substrate and at a ring electrode tip on the micropipet probe. The probes were constructed by insulating gold-coated borosilicate micropipets with electrophoretic paint and exposing a ring electrode at the tip by heat treatment. Characterization of the probes was performed using scanning electron microscopy, cyclic voltammetry, and SECM approach curve experiments. Routine construction of tips with diameters of the order of 3 microm was possible using this technique. The probes exhibited stable steady-state currents and positive and negative feedback approach curves that agreed with those predicted by theory. Demonstrative SECM imaging experiments were performed using a picodispenser to continuously dispense an electroactive solution (ferrocenemethanol) to the SECM cell while the probe was located within a few micrometers of a Pt substrate surface. Oxidation of the dispensed electroactive solution was performed at the substrate, and feedback currents were measured at the probe tip by holding the gold ring at a reducing potential. This mode of tip-dispensing SECM was used to obtain images of a platinum substrate electrode while monitoring both the substrate current and the feedback current at the probe.  相似文献   

3.
The theory of the feedback mode of scanning electrochemical microscopy is extended for probing heterogeneous electron transfer at an unbiased conductor. A steady-state SECM diffusion problem with a pair of disk ultramicroelectrodes as a tip and a substrate is solved numerically. The potential of the unbiased substrate is such that the net current flow across the substrate/solution interface is zero. For a reversible substrate reaction, the potential and the corresponding tip current depend on SECM geometries with respective to the tip radius including not only the tip-substrate distance and the substrate radius but also the thickness of the insulating sheath surrounding the tip. A larger feedback current is obtained using a probe with a thinner insulating sheath, enabling identification of a smaller unbiased substrate with a radius that is approximately as small as the tip radius. An intrinsically slow reaction at an unbiased substrate as driven by a SECM probe can be quasi-reversible. The standard rate constant of the substrate reaction can be determined from the feedback tip current when the SECM geometries are known. The numerical simulations are extended to an SECM line scan above an unbiased substrate to demonstrate a "dip" in the steady-state tip current above the substrate center. The theoretical predictions are confirmed experimentally for reversible and quasi-reversible reactions at an unbiased disk substrate using disk probes with different tip radii and outer radii.  相似文献   

4.
Lee Y  Amemiya S  Bard AJ 《Analytical chemistry》2001,73(10):2261-2267
Ring ultramicroelectrodes, which are of particular interest as probes for scanning electrochemical microscopy (SECM), combined with near-field scanning optical microscopy, were investigated. Theoretical SECM tip current-distance (approach) curves for a ring electrode were calculated by numerical (finite element) analysis. The SECM curves obtained were a function of the geometry of the tips including the thickness of the ring and the insulating sheath. Theoretical approach curves over conductive substrates showed a strong dependence on the ratio of inner to outer radii of ring microelectrodes (a/b) and were relatively insensitive to the thickness of the insulating sheath (r(g)). For insulating substrates, however, the approach curves varied significantly with r(g), but much less with the a/b ratio. Comparison of experimental and theoretical SECM curves provided a good method of evaluating the size and shape of ring electrodes. Good agreement of the experimental and theoretical curves was found with a ring microelectrode with a nominal 200-nm ring thickness, yielding values of 1.7, 1.9, and 5.7 microm for the inner (a) and outer (b) radii of a ring and the outermost radius of insulating sheath (r(g)), respectively.  相似文献   

5.
The potential of ring-disk ultramicroelectrodes (RD UMEs) as probes for scanning electrochemical microscopy (SECM) was investigated both theoretically and experimentally. In particular, the disk-generation/ring-collection (DG/RC) mode of operation was considered. In this case, the interaction of two species with the substrate under investigation can be followed simultaneously from single tip current-distance measurement (approach curve) to the substrate. Theoretical approach curves for DG/RC were calculated by numerical methods. Such approach curves to both insulating and conducting substrates indicate a strong tip response dependence on the ring radius while the response was relatively insensitive to ring thickness and overall tip radius. The RD tip was characterized by fitting experimental approach curves recorded at insulating and conducting substrates to simulated curves for a given tip geometry. DG/RC SECM was then applied to investigate the partitioning of iodine across a liquid-liquid interface.  相似文献   

6.
Scanning electrochemical microscopy (SECM) is described using a band microelectrode tip. Numerical calculations allow the determination of approach curves of an insulating or a conductive substrate, and the numerical analysis is compared to experimental curves. Natural convection provides a steady-state current at the band microelectrode at an infinite distance from the substrate, and the band tip may be used in the SECM configuration as easily as the tip of a disk. Owing to the millimetric dimension of the band microelectrode, the substrate has an influence on the current at much longer distances than with the disk. Finally, the advantage of SECM with a band microelectrode is observed with the fast electrochemical modification of a fluoropolymer surface.  相似文献   

7.
A batch fabrication process at the wafer-level integrating ring microelectrodes into atomic force microscopy (AFM) tips is presented. The fabrication process results in bifunctional scanning probes combining atomic force microscopy with scanning electrochemical microscopy (AFM-SECM) with a ring microelectrode integrated at a defined distance above the apex of the AFM tip. Silicon carbide is used as AFM tip material, resulting in reduced mechanical tip wear for extended usage. The presented approach for the probe fabrication is based on batch processing using standard microfabrication techniques, which provides bifunctional scanning probes at a wafer scale and at low cost. Additional benefits of batch fabrication include the high processing reproducibility, uniformity, and tuning of the physical properties of the cantilever for optimized AFM dynamic mode operation. The performance of batch-fabricated bifunctional probes was demonstrated by simultaneous imaging micropatterned platinum structures at a silicon dioxide substrate in intermittent (dynamic) and contact mode, respectively, and feedback mode SECM. In both, intermittent and contact mode, the bifunctional probes provided reliable correlated electrochemical and topographical data. In addition, simulations of the diffusion-limited steady-state currents at the integrated electrode using finite element methods were performed for characterizing the developed probes.  相似文献   

8.
Zoski CG  Liu B  Bard AJ 《Analytical chemistry》2004,76(13):3646-3654
Finite conical electrodes, which are of particular interest as probes for imaging of surfaces using scanning electrochemical microscopy (SECM), in kinetic studies and in probing thin films were investigated. Theoretical SECM tip current-distance feedback (approach) curves for a finite conical electrode were calculated by numerical (finite element) analysis and compared to an earlier approximate model. The SECM curves obtained depended on the ratio of the base radius of the cone to the height of the cone and on the thickness of the insulating sheath. A new approach to fabricating conical tips of Pt in glass is described. These were used to obtain approach curves over both electrically conducting and insulating substrates. Comparison of experimental and simulated SECM approach curves provided a sensitive method of evaluating the size and shape of finite conical electrodes.  相似文献   

9.
A combined scanning electrochemical microscope (SECM)-atomic force microscope (AFM) is described. The instrument permits the first simultaneous topographical and electrochemical measurements at surfaces, under fluid, with high spatial resolution. Simple probe tips suitable for SECM-AFM, have been fabricated by coating flattened and etched Pt microwires with insulating, electrophoretically deposited paint. The flattened portion of the probe provides a flexible cantilever (force sensor), while the coating insulates the probe such that only the tip end (electrode) is exposed to the solution. The SECM-AFM technique is illustrated with simultaneous electrochemical-probe deflection approach curves, simultaneous topographical and electrochemical imaging studies of track-etched polycarbonate ultrafiltration membranes, and etching studies of crystal surfaces.  相似文献   

10.
This paper presents a microfluidic push-pull probe for scanning electrochemical microscopy (SECM) consisting of a working microelectrode, an integrated counter/reference electrode and two microchannels for pushing and pulling an electrolyte solution to and away from a substrate. With such a configuration, a droplet of a permanently renewed redox mediator solution is maintained just at the probe tip to carry out SECM measurements on initially dry substrates or in microenvironments. For SECM imaging purposes, the probe fabricated in a soft polymer material is used in a contact regime. SECM images of various gold-on-glass samples demonstrate the proof-of-concept of a push-pull probe for local surface activity characterization with high spatial resolution even on vertically oriented substrates. Finite element computations were performed to guide the improvement of the probe sensitivity.  相似文献   

11.
Sun P  Mirkin MV 《Analytical chemistry》2007,79(15):5809-5816
Slightly recessed nanoelectrodes were prepared by controlled etching of nanometer-sized, flat Pt electrodes. By using high-frequency (e.g., 2 MHz) ac voltage, the layer of Pt as thin as greater, approximately >3 nm was removed to produce a cylindrical cavity inside the insulating glass sheath. The etched electrodes were characterized by combination of voltammetry and scanning electrochemical microscopy (SECM) to determine the radius and the effective depth of the recess. The theory was developed for current versus distance curves obtained with a recessed tip approaching either a conductive or an insulating substrate. Good agreement between the theoretical and experimental approach curves indicated that recessed nanotips are suitable for quantitative feedback mode SECM experiments.  相似文献   

12.
Local feedback mode is introduced as a novel operation mode of scanning electrochemical microscopy (SECM) for electrochemical characterization of a single one-dimensional (1D) nanostructure, for example, a wire, rod, band, and tube with 1-100-nm width and micrometer to centimeter length. To demonstrate the principle, SECM feedback effects under diffusion limitation were studied theoretically and experimentally with a disk probe brought near a semi-infinitely long band electrode as a geometrical model for a conductive 1D nanostructure. As the band becomes narrower than the disk diameter, the feedback mechanism for tip current enhancement is predicted to change from standard positive feedback mode, to positive local feedback mode, and then to negative local feedback mode. The negative local feedback effect is the only feedback effect that allows observation of a 1D nanostructure without serious limitations due to small lateral dimension, available tip size, or finite electron-transfer rate. In line-scan and approach-curve experiments, an unbiased Pt band electrode with 100-nm width and 2.6-cm length was detectable in negative local feedback mode, even using a 25-microm-diameter disk Pt electrode. Using a 2-microm-diameter probe, both well-defined and defected sites were observed in SECM imaging on the basis of local electrochemical activity of the nanoband electrode. Noncontact and spatially resolved measurement is an advantage of this novel SECM approach over standard electrochemical approaches using electrodes based on 1D nanostructure.  相似文献   

13.
Amemiya S  Bard AJ 《Analytical chemistry》2000,72(20):4940-4948
Voltammetric ion-selective micropipet electrodes for use in scanning electrochemical microscopy (SECM) for detection of potassium ion were fabricated. These used pulled borosilicate capillaries with tip orifice radii of 0.7-20 microm with silanized inner walls filled with a solution of 10 mM valinomycin and 10 mM ETH 500 in dichloroethane. The electrodes were characterized by determining the steady-state tip current for K+ concentrations of 0.05-0.3 mM. The tips were used in the SECM feedback and generation-collection modes to study K+ transfer through gramicidin channels in a horizontal bilayer lipid membrane (glycerol monooleate).  相似文献   

14.
We present a novel approach to develop and process a microelectrode integrated in a standard AFM tip. The presented fabrication process allows the integration of an electroactive area at an exactly defined distance above of the end of a scanning probe tip and the subsequent remodeling and sharpening of the original AFM tip using a focused ion beam (FIB) technique (See ref 1 for patent information). Thus, the functionality of scanning electrochemical microscopy (SECM) can be integrated into any standard atomic force microscope (AFM). With the demonstrated approach, a precisely defined and constant distance between the microelectrode and the sample surface can be obtained, alternatively to the indirect determination of this distance usually applied in SECM experiments. Hence, a complete separation of the topographical information and the electrochemical signal is possible. The presented technique is a significant step toward electrochemical imaging with submicrometer electrodes as demonstrated by the development of the first integrated frame submicroelectrode.  相似文献   

15.
Combined scanning electrochemical atomic force microscopy (SECM-AFM) is a recently introduced scanned probe microscopy technique where the probe, which consists of a tip electrode and integrated cantilever, is capable of functioning as both a force sensor, for topographical imaging, and an ultramicroelectrode for electrochemical imaging. To extend the capabilities of the technique, two strategies for noncontact amperometric imaging-in conjunction with contact mode topographical imaging-have been developed for the investigation of solid-liquid interfaces. First, SECM-AFM can be used to image an area of the surface of interest, in contact mode, to deduce the topography. The feedback loop of the AFM is then disengaged and the stepper motor employed to retract the tip a specified distance from the sample, to record a current image over the same area, but with the tip held in a fixed x-y plane above the surface. Second, Lift Mode can be employed, where a line scan of topographical AFM data is first acquired in contact mode, and the line is then rescanned to record SECM current data, with the tip maintained at a constant distance from the target interface, effectively following the contours of the surface. Both approaches are exemplified with SECM feedback and substrate generation-tip collection measurements, with a 10-microm-diameter Pt disk UME serving as a model substrate. The approaches described allow electrochemical images, acquired with the tip above the surface, to be closely correlated with the underlying topography, recorded with the tip in intimate contact with the surface.  相似文献   

16.
In atomic force microscopy (AFM), sharp and wear-resistant tips are a critical issue. Regarding scanning electrochemical microscopy (SECM), electrodes are required to be mechanically and chemically stable. Diamond is the perfect candidate for both AFM probes as well as for electrode materials if doped, due to diamond's unrivaled mechanical, chemical, and electrochemical properties. In this study, standard AFM tips were overgrown with typically 300 nm thick nanocrystalline diamond (NCD) layers and modified to obtain ultra sharp diamond nanowire-based AFM probes and probes that were used for combined AFM-SECM measurements based on integrated boron-doped conductive diamond electrodes. Analysis of the resonance properties of the diamond overgrown AFM cantilevers showed increasing resonance frequencies with increasing diamond coating thicknesses (i.e., from 160 to 260 kHz). The measured data were compared to performed simulations and show excellent correlation. A strong enhancement of the quality factor upon overgrowth was also observed (120 to 710). AFM tips with integrated diamond nanowires are shown to have apex radii as small as 5 nm and where fabricated by selectively etching diamond in a plasma etching process using self-organized metal nanomasks. These scanning tips showed superior imaging performance as compared to standard Si-tips or commercially available diamond-coated tips. The high imaging resolution and low tip wear are demonstrated using tapping and contact mode AFM measurements by imaging ultra hard substrates and DNA. Furthermore, AFM probes were coated with conductive boron-doped and insulating diamond layers to achieve bifunctional AFM-SECM probes. For this, focused ion beam (FIB) technology was used to expose the boron-doped diamond as a recessed electrode near the apex of the scanning tip. Such a modified probe was used to perform proof-of-concept AFM-SECM measurements. The results show that high-quality diamond probes can be fabricated, which are suitable for probing, manipulating, sculpting, and sensing at single digit nanoscale.  相似文献   

17.
Imaging of localized hybridization of nucleic acids immobilized on gold-DNA chip was performed by means of the feedback mode of scanning electrochemical microscopy (SECM). Thiol-tethered oligodeoxynucleotide (HS-ODN) probes, spotted on a gold surface, were hybridized with unmodified target sequence via sandwich hybridization with a biotinylated signaling probe. Spots where sequence-specific hybridization had occurred were developed by adding a streptavidin-alkaline phosphatase conjugate and biocatalyzed precipitation of an insoluble and insulating product. As a consequence, the surface conductivity of the spotted region of the chip where hybridization had taken place changed. These changes in conductivity were sensitively detected by the SECM tip. The proposed method allows imaging of a DNA array in a straightforward way. Analysis of real samples was also performed coupling this method with polymerase chain reaction. The imaging of 60 nM PCR amplicon (255 bp) was demonstrated.  相似文献   

18.
A scanning electrochemical microscopy (SECM) methodology for localized quantitative kinetic studies of electrode reactions based on the tip generation-substrate collection (TG-SC) operation mode is presented. This approach does not use the mediator feedback required in typical kinetic SECM experiments. The reactant is galvanostatically electrogenerated on a tip placed in proximity to the substrate. It diffuses through the tip-substrate gap and undergoes the reaction of interest on the substrate surface. The substrate current is monitored with time until it reaches an apparent steady-state value. The process was digitally simulated using an explicit finite difference method, for an irreversible first-order electrode reaction at the substrate. Transient responses, steady-state polarization curves, and TG-SC approach curves can be used to obtain substrate kinetics. The effects of the experimental parameters were analyzed. The possibility of easily changing the experimental conditions with the SECM is an attractive approach to obtain independent evidence that can be used for a strict test of reaction mechanisms. The technique was applied for a preliminary simplified kinetic examination of the oxygen reduction reaction in phosphoric acid.  相似文献   

19.
Nanometer-sized pipets pulled from glass or quartz capillaries have been extensively used as probes for scanning electrochemical microscopy (SECM) and scanning ion conductance microscopy (SICM). A small separation distance between such a probe and the sample, which is required for high-resolution SECM measurements, may be hard to attain because of considerable roughness of the pipet tip. In this Letter, we report the preparation and characterization of polished nanopipet SECM probes with a much smoother tip edge. Using polished pipets, quantitative SECM measurements were performed at extremely short tip/substrate distances (e.g., d ≈ 1 nm).  相似文献   

20.
Undifferentiated and differentiated PC12 cells were imaged with the constant-distance mode of scanning electrochemical microscopy (SECM) using carbon ring and carbon fiber tips. Two types of feedback signals were used for distance control: the electrolysis current of a mediator (constant-current mode) and the impedance measured by the SECM tip (constant-impedance mode). The highest resolution was achieved using carbon ring electrodes with the constant-current mode. However, the constant-impedance mode has the important advantages that topography and faradaic current can be measured simultaneously, and because no mediator is required, the imaging can take place directly in the cell growth media. It was found that vesicular release events do not measurably alter the impedance, but the depolarizing solution, 105 mM K+, produces a dramatic impedance change such that constant-distance imaging cannot be performed during application of the stimulus. However, by operating the tip in the constant-height mode, cell morphology (via a change in impedance) and vesicular release could be detected simultaneously while moving the tip across the cell. This work represents a significant improvement over previous SECM imaging of model neurons, and it demonstrates that the combination of amperometry and constant-impedance SECM has the potential to be a powerful tool for investigating the spatial distribution of neurotransmitter release in vitro.  相似文献   