首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Over the last several decades, various approaches to strengthening steel structures through the use of Carbon fibre reinforced polymer (CFRP) composites have been investigated; however, most of the studies have been focused on the steel tubes. This paper presents the feasibility analysis on the application of CFRP composite strips to strengthen the CFST column member under axial loading. CFRP strips having a width of 50 mm were used to confine the columns. The experimental parameters were the spacing between the CFRP strips (20 and 30 mm) and number of CFRP layers (one, two and three layers). All columns were tested under axial compression until failure. The experimental results revealed that bonding of CFRP composites effectively delayed the local buckling of the columns and also reduced the axial deformation by providing a confinement/restraining effect against the elastic deformation at both spacings. The confinement effect provided by CFRP composites was increased with the increase in the number of layers; however, the enhancement in buckling stress was not proportional. The load carrying capacity of the column increased with the application of CFRP strips, by up to 30% compared to the of un-strengthened column. From the test results it is suggested that the application of CFRP strips at a spacing of 20 mm or 30 mm is suitable for strengthening of a CFST circular column member; however, the application of strips at intervals of 30 mm recommended as an economical approach to strengthening compared to the 20 mm spacing. Finally, an analytical equation was proposed to predict the load carrying capacity of the CFRP strengthened CFST column, and the average difference between the calculated and experimental value was only ±5%.  相似文献   

2.
Rehabilitation and strengthening of concrete structures with externally bonded fibre reinforced polymers (FRPs) has been a viable technique for at least a decade. An interesting and useful application is strengthening of slabs or walls where openings are introduced. In these situations, FRP sheets are very suitable; not only because of their strength, but also due to that they are easy to apply in comparison to traditional steel girders or other lintel systems. Even though many benefits have been shown by strengthening openings with FRPs not much research have been presented in the literature.In this paper, laboratory tests on 11 slabs with openings, loaded with a distributed load are presented together with analytical and numerical evaluations. Six slabs with openings have been strengthened with carbon fibre reinforced polymers (CFRPs) sheets. These slabs are compared with traditionally steel reinforced slabs, both with (four slabs) and without openings (one slab). The slabs are quadratic with a side length of 2.6 m and a thickness of 100 mm. Two different sizes of openings are used, 0.85 × 0.85 m and 1.2 × 1.2 m.The results from the tests show that slabs with openings can be strengthened with externally bonded CFRP sheets. The performance is even better than for traditionally steel reinforced slabs. The numerical and analytical evaluations show good agreement with the experimental results.  相似文献   

3.
The strengthening of reinforced concrete structures with externally bonded fibre reinforced polymer (FRP) laminates has shown excellent performance and, as a result, this technology is rapidly replacing steel plate bonding techniques. The numerous studies that have been carried out to date on FRP-strengthened concrete elements have mainly focussed on the static and short-term responses; very little work has been done regarding the long-term performance. This paper addresses this issue, and presents results from a series of experiments on the time-dependent behaviour of carbon FRP-strengthened concrete beams. Twenty-six reinforced concrete beams with dimensions 100 × 150 × 1800 mm, with and without bonded CFRP laminates, were investigated for their creep behaviour. Different reinforcement ratios were used to evaluate the contribution of the external reinforcement on the creep resistance of the beams. High levels of sustained load were used in order to determine the maximum sustained load that can be applied without any risk of creep failure. The applied sustained loads varied from 59% to 78% of the ultimate static capacities of the un-strengthened beams. For most of the long-term tests, the applied sustained loads were higher than the service loads. This was done to account for the fact that strengthening is typically required when a structure is expected to carry increased service loads. The main parameters of this study were (i) the level of sustained load and (ii) the strengthening scheme. The results confirm that FRP strengthening is effective for increasing the ultimate capacities of the beams; however, there is virtually no improvement in performance with regard to the long-term deflections.  相似文献   

4.
The objective of the research was to examine the creep behavior of masonry walls strengthened with FRP composites compared to that of conventional reinforcement. Eight full-scale (40 in wide by 96 in tall [1.02 m × 2.44 m]) unreinforced concrete masonry walls were constructed for testing long-term deflections out-of-plane. The walls were strengthened with externally bonded CFRP or GFRP composites. Two additional walls were constructed with mild steel reinforcement grouted in the center cell of the specimens. Long-term deflections due to creep in FRP reinforced walls were shown to be ≈22–56% higher than those of steel reinforced walls.  相似文献   

5.
This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with carbon fibre reinforced polymers (CFRP). The next four specimens had steel fibres added to the concrete. The final four specimens were reinforced with steel fibres and wrapped with CFRP. From each group of specimens, one specimen was tested as a column under a concentric load, the second specimen was tested as a column under 25 mm eccentricity, the third specimen was tested as a column under 50 mm eccentricity, and the final specimen was tested as a beam under four point loading regime. The experimental programme proved that the introduction of fibres as well as wrapping the specimens with FRP improve the properties of concrete, especially its ductility.  相似文献   

6.
This paper presents the results of the first phase of a study on the effect of the confinement provided by transverse carbon fiber reinforced polymer (CFRP) sheets on the fatigue bond strength of steel reinforcing bars in concrete beams. Reinforced concrete bond-beams 150 × 250 × 2000 mm were tested. The variables examined were the area of the CFRP sheets (none or one U-wrap CFRP sheet), the reinforcing bar diameter (20 or 25 mm) and the load range applied to the specimens. The results showed that increasing the bar diameter increased the fatigue bond strength for the unwrapped beams. The CFRP sheets increased the bond strength of the bond-beams with 20 mm bars. However, for the beams with 25 mm steel bars the failure mode changed from a bond splitting failure for the unwrapped beams to a diagonal shear failure for the CFRP wrapped beams, and there was little increase in fatigue strength. Finally, the bond failure mechanism for repeated loading is described.  相似文献   

7.
This paper presents the results of an experimental program to investigate the effect of high temperature on the performance of concrete externally confined with FRP sheets. For this purpose, a two-phase experimental program was conducted. In the first phase, 42 standard 100 × 200 mm concrete cylinders were prepared. Out of these specimens, 14 cylinders were left unwrapped; 14 specimens were wrapped with one layer of CFRP sheet; and the remaining 14 specimens were wrapped with one layer of GFRP sheet. Some of the unconfined and FRP-confined specimens were exposed to room temperature; whereas, other cylinders were exposed to heating regime of 100 °C and 200 °C for a period of 1, 2 or 3 h. After high temperature exposure, specimens were tested under uniaxial compression till failure. The test results demonstrated that at a temperature of 100 °C (a little more than the glass transition temperature (Tg) of the epoxy resin), both CFRP- and GFRP-wrapped specimens experienced small loss in strength resulting from melting of epoxy. This loss of strength was more pronounced when the temperature reached 200 °C. In the second phase of the experimental program, three 100 × 100 × 650 mm concrete prisms were prepared and then overlaid by one layer of CFRP and GFRP laminates for conducting pull-off strength tests as per ASTM D4541 – 09. The objective of this testing was to evaluate the degradation in bond strength between FRP and concrete substrate when exposed to elevated temperature environments. One prism was exposed to room temperature whereas the other two specimens were exposed to heating regime of 100 °C and 200 °C for a period of 3 h. It was concluded that a significant degradation in the bond strength occurred at a temperature of 200 °C especially for CFRP-overlaid specimens.  相似文献   

8.
The transfer length of a prestressed near surface mounted (NSM) fiber reinforced polymer (FRP) rod is the distance over which the rod must be bonded to the epoxy to develop the prestressing force in the rod. The transfer length is intended to provide bond integrity for the strengthened concrete member. This paper presents experimental results and an empirical equation to estimate the transfer length of prestressed NSM Carbon FRP (CFRP) rod in concrete beams. Twenty-two reinforced concrete specimens were strengthened with NSM CFRP rods. Two types of CFRP rods were used: spirally wound and sand blasted rods. Four prestressing levels were used: 40%, 45%, 50% and 60% of the tensile strength of the CFRP rod. The strain behavior in the CFRP rod was monitored by gauges mounted on the CFRP rod along the length of the beam. The test results showed that the transfer length of the prestressed NSM CFRP rod was about 35 times the diameter of the CFRP rod. The maximum bond stress of the CFRP rod in epoxy was found to range from 11 to 16 MPa for the sand blasted rods and from 12 to 23 MPa for the spirally wound rods. An empirical expression based on curve fitting of the measured data was proposed to predict the prestressing stress in the CFRP rod along the length of the beam.  相似文献   

9.
This paper presents an experimental investigation on behaviour and design of built-up cold-formed steel section battened columns. The built-up columns were pin-ended and consisted of two cold-formed steel channels placed back-to-back at varied spacing of intersection. The two channels were connected using batten plates, with varying longitudinal spacing. The cold-formed steel channel sections were manufactured by brake-pressing flat strips having a plate thickness of 2 mm. The built-up cold-formed steel section battened columns had different slenderness and geometries but had the same nominal length of 2200 mm. The column strengths, load–axial shortening, load–lateral displacement and load–axial strain relationships were measured in the tests. In addition, the failure modes and deformed shapes at failure were observed in the tests and reported in this paper. Overall, the built-up column tests provided valuable experimental data regarding the column behaviour that compensated the lack of information on this form of construction as well as used to develop nonlinear 3-D finite element models. The column strengths measured experimentally were compared against design strengths calculated using the North American Specification, Australian/New Zealand Standard and European Code for cold-formed steel columns. Generally, it is shown that the specifications were unconservative for the built-up cold-formed steel section battened columns failing mainly by local buckling, while the specifications were conservative for the built-up columns failing mainly by elastic flexural buckling.  相似文献   

10.
This paper summarizes the results of experimental studies on damaged reinforced concrete beams repaired by external bonding of carbon fiber reinforced polymer (CFRP) composite laminates to the tensile face of the beam. Two sets of beams were tested in this study: control beams (without CFRP laminates) and damaged and then repaired beams with different amounts of CFRP laminates by varying different parameters (damage degree, CFRP laminate width, concrete strength class). All beams were tested in four-point bending over a span of 1800 mm. The tests were carried out under displacement control. The most investigated parameter in this experimental study is damage degree (ratio between pre-cracked load and load capacity of control beam). Repairing damaged RC beams with externally bonded CFRP laminates were successful for different degrees of damage. The observed failure modes were peeling off and interfacial debonding. These failure modes depend only on the laminate width.The results indicate that the load capacity and the rigidity of repaired beams were significantly higher then those of control beam for all tested damage degrees. The authors remarked that for a load capacity improvement, reinforcement with a CFRP having about a half width of the beam is satisfactory. Finally, the contribution of CFRP laminates on the load capacity and rigidity of repaired RC beams is significant for any concrete strength class.  相似文献   

11.
The effectiveness of strengthening reinforced concrete (RC) beams with prestressed near-surface mounted (NSM) carbon fiber reinforced polymer (CFRP) rods was investigated. Four RC beams (254 mm deep by 152 mm wide by 3500 mm long) were tested under monotonic loading. One beam was kept un-strengthened as a control beam. One beam was strengthened with a non-prestressed NSM CFRP rod. Two beams were strengthened with prestressed NSM CFRP rods stressed to 40% and 60% of the rod’s ultimate strength. The test results showed that strengthening with non-prestressed NSM CFRP rod enhanced the flexural response of the beam compared to that of the control beam. A remarkable improvement in the response was obtained when the RC beams were strengthened with prestressed (40% and 60%) NSM CFRP rods. An increase up to 90% in the yield load and a 79% in the ultimate load compared to those of the control beam were obtained. An analytical model was developed using sectional analysis method to predict the flexural response of RC beams strengthened with prestressed NSM CFRP rods. The proposed model showed excellent agreement with the experimental results.  相似文献   

12.
The benefits of adding fibres to concrete, evidenced in the post-cracking behaviour, are strongly influenced not only by the type and content of fibres but also by their orientation. The objective of this study is to evaluate the influence of the casting/placing procedure on the post-peak behaviour of fibre reinforced self-compacting concrete, and its relationship with the mesostructural characteristics of the material (type, distribution and orientation of fibres). Three concretes were prepared using two types of steel fibres of different lengths (50 mm and 30 mm) and a structural type polymer fibre. Beams of 150 × 150 × 600 mm were cast in three different ways: filling the moulds from the centre in accordance with the EN 14651 Standard, pouring concrete from one end of the mould after a flowing along a 5 m length and 150 mm diameter pipe, and finally, filling the moulds vertically. Flexural tests according to the European Standard indicate that the three types of fibres achieve a preferential orientation along horizontal planes, like in conventional vibrated fibre reinforced concrete. The mechanical response of beams cast with longer steel fibres was strongly affected by the casting procedure while the flexural performance of the other two fibre concretes, was less affected. Such results are well in accordance with the density of fibres measured by fibre counting in different cut planes.  相似文献   

13.
Sixteen under-reinforced high strength concrete one-way slabs were cast, heated at 600 °C for 2 h, repaired, and then tested under four-point loading to investigate the coupling effect of water recuring and repairing with advance composite materials on increasing the flexural capacity of heat-damaged slabs. The composites used included high strength fiber reinforced concrete layers; and carbon and glass fiber reinforced polymer (CFRP and GFRP) sheets. Upon heating then cooling, the reinforced concrete (RC) slabs experienced extensive map cracking, and upward cambering without spalling. Recuring the heat-damaged slabs for 28 days allowed recovering the original stiffness without achieving the original load carrying capacity. Other slabs, recured then repaired with steel fiber reinforced concrete (SFRC) layers, regained from 79% to 84% of the original load capacity with a corresponding increase in stiffness from 382% to 503%, whereas those recured then repaired with CFRP and GFRP sheets, regained up to 158% and 125% of the original load capacity with a corresponding increase in stiffness of up to 319% and 197%, respectively. Control, heat-damaged, and water recured slabs showed a typical flexural failure mode with very fine and well distributed hairline cracks, propagated from the repair layers to concrete compression zone. RC slabs repaired with SFRC layers failed in flexural through a single crack, propagated throughout the compression zone, whereas those repaired with CFRP and GFRP experience yielding failure of steel prior to the composites failure.  相似文献   

14.
This paper presents an experimental study investigating the behavior of FRP-reinforced concrete bridge deck slabs under concentrated loads. A total of eight full-scale deck slabs measuring 3000-mm long by 2500-mm wide were constructed. The test parameters were: (i) slab thickness (200, 175 and 150 mm); (ii) concrete compressive strength (35–65 MPa); (iii) bottom transverse reinforcement ratio (1.2–0.35%); and (iv) type of reinforcement (GFRP, CFRP, and steel). The slabs were supported on two parallel steel girders and were tested up to failure under monotonic single concentrated load acting on the center of each slab over a contact area of 600 × 250 mm to simulate the footprint of sustained truck wheel load (87.5 kN CL-625 truck). All deck slabs failed in punching shear. The punching capacity of the tested deck slabs ranged from 1.74 to 3.52 times the factored load (Pf) specified by the Canadian Highway Bridge Design Code (CHBDC) CAN/CSA S6-06. Besides, the ACI 440.1R-06 punching strength equation greatly underestimated the capacity of the tested slabs with an average experimental-to-predicted punching capacity ratio (Vexp/Vpred) of 3.17.  相似文献   

15.
This paper presents results of tests conducted on thin welded rectangular steel stubs filled with concrete that gravel was substituted by 10 mm crushed crystallized slag stone. The studied section was made of two cold steel plates with U shape and welded with electric arc to form a steel box section. The cross-section dimensions were: 100×70×2 mm3. the main studied parameters were the stub height (200, 300, 400, 500 mm), the effect of the in filled concrete, the continued weld and the eccentric force. The tests were carried out 28 days after the date of casting. A total of 20 stubs were tested in a 50 tf machine up to failure, 4 stubs subjected to axial load compression and 16 stubs subjected to eccentric load compression along the minor and major rigidity axis. The aim of the study is to provide some evidences that the use of crushed slag could be integrated in the manufacturing of non-conventional concrete. All failure loads were predicted by using the Euro code 4 and the design method proposed by Z. Vrcelj and B. Uy. From test results, it was confirmed that the length of stubs and the eccentric load had a drastic effect on the load carrying capacity. The failure mode of composite stubs was a local buckling mode with all steel sides deformed outwards. The Euro code 4 loads predictions were generally in good agreement compared with experimental loads and on safe side. The loads results of design method proposed by Vrcelj and B. Uy were generally on safe side compared with experimental load except the columns subject to eccentric load with 400 mm and 500 mm height.  相似文献   

16.
Carbon fiber reinforced polymers (CFRP) have been widely used in the retrofitting and strengthening of concrete structures. However, the layouts of CFRP in externally bonded (EB) strengthening system and near surface mounted (NSM) system result in the vulnerability of fire resistance. To explore the fire resistance potential of NSM-CFRP strengthening system, 15 RC beams strengthened with CFRP and 2 reference beams were loaded to failure either under the ISO834 standard fire or at ambient temperature. In test, the following factors were considered: the strengthening method (near surface mounted technique/externally bonded technique), adhesive (epoxy and magnesium-oxychloride cement), fire protection materials (thin intumescent fire retardant coating and thick fire retardant coating) and location of fire protection (local patch protection/single-sided protection/U-shaped protection). With appropriate fire protection, the RC beams strengthened with NSM-CFRP resisted the standard fire for more than 3 h at high load level. Besides the effects of the aforementioned factors, the friction stress at the CFRP/matrix interface when CFRP is in globally slipping is found playing a crucial role for the fire resistance of NSM-CFRP strengthening system. The experimental observation sheds some light on how the NSM-CFRP strips can retain the contribution at elevated temperatures and why NSM-CFRP strengthening outperforms EB-CFRP strengthening when exposed to fire.  相似文献   

17.
Though there have been a number of studies on shear strengthening of RC beams using externally bonded fiber reinforced polymer sheets, the behaviour of FRP strengthened beams in shear is not fully understood. This is partly due to various reinforcement configurations of sheets that can be used for shear strengthening and partly due to different failure modes a strengthened beam undergoes at ultimate state. Furthermore, the experimental data bank for shear strengthening of concrete beams using FRP remains relatively sparse due to which the design algorithms for computing the shear contribution of FRP are not yet clear. The objective of this study is to clarify the role of glass fiber reinforced polymer inclined strips epoxy bonded to the beam web for shear strengthening of reinforced concrete beams. Included in the study are effectiveness in terms of width and spacing of inclined GFRP strips, spacing of internal steel stirrups, and longitudinal steel rebar section on shear capacity of the RC beam. The study also aims to understand the shear contribution of concrete, shear strength due to steel bars and steel stirrups and the additional shear capacity due to glass fiber reinforced polymer strips in a RC beam. And also to study the failure modes, shear strengthening effect on ultimate force and load deflection behaviour of RC beams bonded externally with GFRP inclined strips on the shear region of the beam.  相似文献   

18.
《Thin》2012,50(12):1483-1491
In this era, using concrete filled steel tubular (CFST) members has become very popular in the construction industry; at the same time, ageing of structures and deterioration of members are often reported. Therefore, actions like implementing strengthening techniques with the new materials become essential to combat this problem. Due to their in-service and superior mechanical properties, carbon fibre reinforced polymer (CFRP) composites make an excellent candidate after upgrading. The aim of this study is to experimentally investigate the suitability of CFRP in strengthening of CFST members under flexure. Among eighteen beams, nine beams were strengthened by full wrapping (fibre bonded at the bottom throughout the entire length of beam) and the remaining nine beams were strengthened by partial wrapping (fibre bonded in-between loading points at the bottom). The effect of CFRP layers on the moment carrying capacity of CFST beams was investigated. Also a nonlinear finite element model was developed using the software ANSYS 12.0, to validate the analytical results such as load–deformation and the corresponding failure modes. The experimental results revealed that beams strengthened by partial wrapping failed by delamination of fibre, even before attaining the ultimate load of control beam but the beams strengthened by full wrapping exhibited more enhancements in moment carrying capacity and stiffness. From the numerical simulation and experiments, it is suggested that if any appropriate anchorages are provided in partial wrapping scheme to avoid delamination of fibre, then it will be turned into a fine and economical method for strengthening of CFST members.  相似文献   

19.
The experimental studies on the behaviour of recycled aggregate concrete-filled steel tube (RACFST) stub columns after exposed to high temperatures are reported in this paper. Forty specimens, including 32 RACFST stub columns and 8 normal concrete-filled steel tube (CFST) stub columns as reference, were tested, and the failure pattern, load versus strain relation and ultimate strength of the specimens were presented and analysed. Five types of concrete were produced: one reference concrete with natural aggregates, two concrete mixes with recycled coarse aggregate (RCA) replacement ratios of 50% and 100%, and two concrete mixes with recycled fine aggregate (RFA) replacement ratios of 50% and 100%. The specimens were exposed to 300 °C, 600 °C and 800 °C for 3 h. The test results showed that, due to the existence of the recycled aggregates, the post-fire performance of RACFST stub columns was lower than the corresponding normal CFST specimens under the same maximum temperature suffered, and the RACFST specimens with RCA had a better behaviour than those with RFA under the same recycled aggregate replacement ratio.  相似文献   

20.
A variety of alternatives to rehabilitate culverts have been developed over the past decades given their advantages over conventional open-cut culvert replacement. However, the performance of many of these systems has not yet been examined through laboratory testing. The objective of the present paper is to examine the performance of deteriorated steel culverts rehabilitated with spray-on liners when subjected to surface loads. Two 1200 mm diameter corrugated steel pipelines with similar levels of deterioration in the invert-haunch area were buried to a depth of 1200 mm and tested under service load employing a load frame simulating a single axle of a Canadian design truck. The pipelines were then rehabilitated with spray on-cementitious liners (each with a different target thickness). Once rehabilitated, the pipelines were examined again under the service load employing the single axle load frame at 1200 mm of soil cover, and then tested employing a tandem axle load frame at 2100 and 1200 mm of soil cover. During all tests, changes in diameter, curvature and liner strains were monitored. The data obtained indicates that the flexible pipelines responded like semi-rigid structures after rehabilitation. It was also observed that the difference in liner thickness of 30% did influence the response of the pipelines, and that extreme fiber tensions during service loading were 7% and 13% of the tensile strength of the liner materials for the 76 mm and 51 mm liner thicknesses that were specified.  相似文献   