共查询到20条相似文献,搜索用时 62 毫秒
1.
2.
发动机和液力变矩器的动力匹配对应急救援排障工程车动力性的研究具有重要意义.两者匹配的理论算法已经相对成熟,但目前算法存在对人员经验要求高、效率低的问题,针对上述问题,提出一种适用于应急救援工程车的发动机与液力变矩器逆向匹配算法,首先根据整车参数及设计指标计算确定发动机型号,再选取工程车起步、高速行驶、高效运行以及换挡四... 相似文献
3.
4.
5.
6.
靳晓华 《仪器仪表与分析监测》1995,(1):10-13
达尔文的进化论,说明了生物在复杂环境中生成和检测的策略。芝加哥大学John Holland敦授认为:“这种策略能迅速识别并开发利用环境中的规律性”。因此,早在70年代,他就开始研究基因算法。 相似文献
7.
8.
9.
运用模糊聚类技术提出了一种通过模糊似然函数动态生成模糊聚类,在线辨识数控加工过程中非线性关系模型的方法,给出数控铣削加工过程中从进给电流信号辨识出铣削力信号的应用算法,为实现加工过程的智能控制奠定了一定的基础,该算法在实际加工中得到了较好的应用。 相似文献
10.
11.
滑坡实时监测报警系统电源设计 总被引:1,自引:0,他引:1
本文提出了一种由太阳能电池和铅蓄电池组成的滑坡实时监测报警系统的电源设计方案。此电源系统由DC/DC变换电路产生系统所需要的各种电压,由UC3906等元件组成双电平浮充充电电路,由继电器完成太阳能电池/铅酸蓄电池之间的切换。 相似文献
12.
13.
Noninvasive respiratory monitoring system based on the piezoceramic transducer's pyroelectric effect
This paper presents a simple alternative method and system for noninvasive respiratory airflow monitoring. The proposed system uses a piezoceramic transducer to measure respiratory airflow. When a piezoceramic transducer is impacted by respiratory airflow, there is a piezoelectric and a pyroelectric response to pressure and thermal airflow fluctuations. In this study, the selected transducer's response output is dominated by the pyroelectricity factor. Therefore, the piezoelectric effect is not significant and can be ignored in this study. Using the transducer's pyroelectricity to measure thermal flow variations, a subject's respiratory rate and respiratory air volumetric flow rate can be monitored. The proposed system was evaluated for accuracy and response time using quiet and postphysical exertion breathing modes. Using the pneumotach system as a benchmark, the proposed system's respiratory rate measurement accuracy for the two breathing modes is approximately 98.78%. In addition, the proposed system's output voltage is highly correlated with the respiratory volumetric flow rate measured by the selected pneumotach (r2=0.9783). The average correlation coefficient between the pneumotach system's output waveform and the proposed system is approximately 0.9389. Moreover, the proposed system and the selected pneumotach have almost the same rapid response time to respiratory airflow. When compared to a temperature measurement thermistor system, the thermistor on average is approximately 25.3 ms slower than the proposed system. Furthermore, compared to the selected screen-type pneumotach system, the proposed system simplifies the respiration monitoring requirements. Instead of sensing the pressure drop across a mesh screen, like the screen-type pneumotach, it measures respiration at one point within the respiratory airflow. The proposed system benefits from simplified processing circuits and a mesh-free design. The advantages of this new respiratory airflow measurement method are fast response time, high accuracy, low cost, and ease of implementation. 相似文献
14.
超宽带雷达系统中图像恢复新算法 总被引:1,自引:1,他引:0
针对超宽带穿墙雷达系统中低信噪比同波信号成像困难的问题,提出了一种基于子空间的约束最小二乘扩展多通道盲图像恢复新算法.在建立穿墙雷达成像退化模型的基础上,将穿墙雷达成像的高分辨问题转化为多通道肓图像恢复问题,并通过把子空间的概念转化为对降晰函数的约束,构造了新的代价函数进行扩展多通道的盲图像恢复.实验结果验证了本文提出的新算法能有效的改善雷达图像的分辨率. 相似文献
15.
设计了一种呼吸道主动监测微型机器人系统,用于实时测量重症监护机械通气中的主要呼吸力学参数.该机器人系统采用三自由度气动人工肌肉驱动器驱动,通过气囊钳位.介绍了机器人机体的构造和运动原理,建立了机器人的动态模型.提出一种模糊小波神经网络控制器对机器人进行控制.将采用模糊小波神经网络控制器与采用小波神经网络控制器及模糊神经网络控制器的控制系统仿真结果进行比较.仿真和实验结果都说明模糊小波神经网络控制器有效地改善了机器人的静动态特性,具有更快的训练速度和更好的控制效果,是一种理想的临测机器人系统控制方法.在猪气管中进行了初步实验,在机械通气情况下监测了气管末端的压力和温度参数.初步的研究结果表明,该柔性驱动的机器人系统可用于主动动态监测人体呼吸道中的呼吸参数. 相似文献
16.
提出了一种新颖的声发射智能传感器网络系统。该系统为三层模块化结构。宽带声发射(AE)传感器采集被测对象的声发射信号;利用DSP实时提取结构缺陷的声发射特征参数并传送给智能终端;最终以无线/有线方式向用户传送有效信息。经实际应用证明该系统具有实时在线远程无损监测大桥。大坝,隧道等钢筋混凝土结构工程健康状况的功能。且系统采用了GPRS和互联网,降低了系统复杂性和成本。 相似文献
17.
18.
19.
该文设计了一种新型PID控制算法,对其在电液比例位置控制系统上的应用进行研究。在介绍新型PID控制算法基本原理的基础上,通过实验比较该系统新型PID控制和常规PID控制对正弦信号的跟踪效果。结果表明,新型PID控制比常规PID控制有更好的精度和稳定性。 相似文献
20.
提出一种基于映射不变量的点云配准算法,首先采用主方向贴合方法做配准预处理,再根据映射不变量寻找对应点,建立对应关系,最后用SVD分解迭代计算刚体变换.该算法具有精确度高的特点,并且在实际应用中验证了配准效果和算法稳定性. 相似文献