首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Aerobic biological treatment of digested sludge was studied in a continuously operated laboratory set-up. An aerated reactor was filled with thermophilically digested sludge from the Moscow wastewater treatment plant and inoculated with special activated sludge. It was then operated at the chemostat mode at different flow rates. Processes of nitrification and denitrification, as well as dephosphatation, occurred simultaneously during biological aerobic treatment of thermophilically digested sludge. Under optimal conditions, organic matter degradation was 9.6%, the concentrations of ammonium nitrogen and phosphate decreased by 89 and 83%, respectively, while COD decreased by 12%. Dewaterability of digested sludge improved significantly. The processes were found to depend on hydraulic retention time, oxygen regime, and temperature. The optimal conditions were as follows: hydraulic retention time 3-4 days, temperature 30-35 degrees C, dissolved oxygen levels 0.2-0.5 mg/L at continuous aeration or 0.7-1 mg/L at intermittent aeration. Based on these findings, we propose a new combined technology of wastewater sludge treatment. The technology combines two stages: anaerobic digestion followed by aerobic biological treatment of digested sludge. The proposed technology makes it possible to degrade the sludge with conversion of approximately 45% volatile suspended solids to biogas, to improve nitrogen and phosphorus removal in reject water from sludge treatment units, and to achieve removal of malodorous substances after 8-9 days of anaerobic-aerobic sludge treatment.  相似文献   

2.
对天津经济技术开发区污水处理厂采用先进的DAT-IAT工艺进行冬季和夏季的实际运行效果比较,并就DAT池和IAT池在运行中的作用进行分析。研究发现:污水处理厂对BOD的平均去除率在96%以上,对COD的平均去除率在75%左右,均能保证出水达标,对于BOD和COD的去除效果冬季和夏季无明显差别,对SS的去除效果冬季略优于夏季,DAT-IAT工艺系统的抗冲击负荷能力较强,污水处理厂DAT池过高的BOD去除率对后续的脱氮除磷效果会产生不利影响。影响处理效果的原因主要为污水处理厂进水量不充足,水质水量变化大,且ρ(BOD)/ρ(COD)值偏低,不利于生化处理。此外,DAT池的非限制性曝气工艺不仅使BOD在DAT池中过度消耗,影响后续处理,而且浪费能源,建议减少DAT池曝气时间或调整DAT池运行参数。  相似文献   

3.
城市污水生物除磷脱氮工艺中的矛盾关系及对策   总被引:50,自引:3,他引:50  
目前 ,城市污水处理厂的处理对象包括COD、BOD5、SS和氮、磷等营养物质。就氮磷脱除而言 ,一般需涉及硝化、反硝化、微生物释磷和吸磷等过程。由于各过程的要求不同 ,在同一污水处理工艺系统中就不可避免地产生了各过程间的矛盾关系。针对泥龄问题、碳源问题、硝酸盐问题、系统的硝化和反硝化容量问题、释磷吸磷的容量问题进行了探讨  相似文献   

4.
The effect of limiting P in activated sludge was investigated in laboratory scale sequencing batch reactors (SBRs) fed effluent from a container board mill. Floc characterization included measurement of hydrophobicity, surface charge, and analysis of extracellular polymeric substances (EPS). Reactor performance was assessed by monitoring COD and inorganic P removal, MLSS, and sludge settleability (SVI and batch settling flux) over a period of eight months. Control reactors (BOD:N:P of 100:5:1) were compared to reactors run under P-limited conditions (100:5:0.3; 100:5:0.1). Reactor performance at lower temperatures (14 degrees C; control = 26 degrees C) was also studied to assess the impact of P-limitation. Changes in floc structure and the composition of EPS occurred within 1 to 3 days following a reduction in P levels. There was an insignificant increase in SVI; however, gravitational settling velocity and batch settling flux values for low P floc were consistently higher than for floc generated under control conditions. Lower temperatures (14 degrees C) resulted in a deterioration in floc settling properties at a BOD:N:P of 100:5:1. This impact on settling was significantly reduced at a BOD:P of 100:0.1. Reducing P concentrations in the wastewater treatment system has the potential to improve sludge settleability and reduce final P discharges.  相似文献   

5.
This study was to investigate domestic treatment efficiency of a subsurface wastewater infiltration (SWI) system over time. The performances of a young SWI system (in Shenyang University, China, fully operated for one year) and a mature SWI system (in Shenyang Normal University, China, fully operated for seven years) under the same operation mode were contrasted through field-scale experiments for one year. The performance assessment for these systems is based on physical and chemical parameters collected. The removal efficiencies within the young system were relatively high if compared with the mature one: for biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), ammonia nitrogen (NH(3)-N) and total phosphorus (TP) were 95.0, 89.1, 98.1, 87.6 and 98.4%, respectively. However, the removal efficiencies decreased over time. The mean removal efficiencies for the mature SWI system were as follows: BOD (89.6%), COD (87.2%), SS (82.6%), NH(3)-N (69.1%) and TP (74.4%). The results indicate that the mature SWI system successfully removed traditional pollutants such as BOD from domestic wastewater. However, the nutrient reduction efficiencies (including NH(3)-N and TP) decreased after seven years of operation of the mature SWI system. Meanwhile, the SWI system did not decrease the receiving surface water quality.  相似文献   

6.
唐双成  罗纨  贾忠华  李山  仵艳 《水利学报》2015,46(8):943-950
雨水花园作为一种生物滞留系统,能够有效降低城市化进程对城市水文和水质带来的负面影响,但其效果与雨水径流中污染物的赋存形态以及花园内部的水力特性等因素有关。通过一项在黄土地区开展的雨水花园对路面雨水径流水文过程及污染物降解的试验研究,分析了雨水花园对不同赋存形态氮磷污染物的去除效果;同时根据雨水花园入流和出流的水文过程监测数据,分析了土壤优先流的存在及其对污染物去除效果的影响。结果显示,雨水花园入流中颗粒态磷和溶解态磷的浓度比例约为4∶1,颗粒态氮和溶解态氮的浓度比例接近1∶1;颗粒态总磷的浓度去除率和负荷去除率分别为40.1%和69.9%,颗粒态总氮的浓度去除率和负荷去除率分别为44.8%和73.8%;系统对于溶解态的氮、磷几乎没有去除能力。雨水花园土壤中存在的优先流现象导致出流速度较快,雨水径流在花园内的水力停留时间较短,结果表明:系统能够拦截颗粒态污染物,但对溶解态污染物去除效果较差;雨水花园对入流中总磷和总氮的浓度去除率很低,平均值仅为6.3%和-2.7%,但因截留了很大比例的入流(平均为51.5%),其对氮、磷污染物总负荷的削减分别达到52.5%和51.5%。所以,利用城市雨水花园来滞留雨水径流,净化雨水水质在研究区具有良好的应用前景。  相似文献   

7.
A study was conducted to evaluate the nutrient removal capability of an existing and successfully operated overland flow and wetland wastewater treatment system following a waste stabilization pond. Seasonal temperature effects on performance were also investigated. The treatment system studied consists of a two-cell waste stabilization pond followed by an overland flow system and a wetland system. The influent and effluent samples were analyzed for BOD5, suspended solids (SS), pH, temperature, ammonia nitrogen, nitrate nitrogen, and total phosphorus. The results of the study indicate that the combined pond, overland flow and wetland system provided excellent treatment of municipal wastewater. The overall average BOD5 removal by the entire treatment system was about 90.0% and the overall average suspended solids removal was about 93.4%. The ammonia nitrogen and total phosphorus removal efficiencies of the entire treatment system were 90.7% and 84.2%, respectively.  相似文献   

8.
A multi-stage municipal wastewater treatment system is proposed to comply with Mexican standards for discharge into receiving water bodies. The system is located in Santa Fe de la Laguna, Mexico, an area with a temperate climate. It was designed for 2,700 people equivalent (259.2 m3/d) and consists of a preliminary treatment, a septic tank as well as two modules operating in parallel, each consisting of a horizontal subsurface-flow wetland, a maturation pond and a vertical flow polishing wetland. After two years of operation, on-site research was performed. An efficient biochemical oxygen demand (BOD5) (94-98%), chemical oxygen demand (91-93%), total suspended solids (93-97%), total Kjeldahl nitrogen (56-88%) and fecal coliform (4-5 logs) removal was obtained. Significant phosphorus removal was not accomplished in this study (25-52%). Evapotranspiration was measured in different treatment units. This study demonstrates that during the dry season wastewater treatment by this multi-stage system cannot comply with the limits established by Mexican standards for receiving water bodies type 'C'. However, it has demonstrated the system's potential for less restrictive uses such as agricultural irrigation, recreation and provides the opportunity for wastewater treatment in rural areas without electric energy.  相似文献   

9.
A pilot-scale fluidised pellet bed (FPB) bioreactor, which combines chemical coagulation, biological degradation, particle pelletisation and separation in one unit, was applied for onsite wastewater treatment and reuse. As a result of rational use of inorganic coagulant and organic polymer and moderate mechanical agitation, spherical particles were generated in the upflow column and a well-fluidised bed was formed. With a continuous supply of dissolved oxygen through a recycling loop, an aerobic condition was kept in the bottom section of the FPB column. Under such conditions the pellets in the FPB column showed the following characteristics: (1) compact structure and high density; (2) rich in microorganisms; and (3) high MLSS and MLVSS concentrations. Therefore, the FPB bioreactor achieved more than 90% removal of SS, COD, BOD and TP from raw domestic wastewater within a total hydraulic retention time (HRT) of only about 30 minutes. It also showed nitrification and denitrification ability and the TN removal could be about 50% as the recycling ratio was increased to 1:1. The treated water quality is generally competitive with the secondary effluent from a conventional activated sludge process. With these advantages the FPB bioreactor is recommendable as a compact system for onsite wastewater treatment and reuse.  相似文献   

10.
This research project aimed to determine the technologically feasible and applicable wastewater treatment systems which will be constructed to solve environmental problems caused by small communities in Turkey. Pilot-scale treatment of a small community's wastewater was performed over a period of more than 2 years in order to show applicability of these systems. The present study involves removal of organic matter and suspended solids in serially operated horizontal (HFCW) and vertical (VFCW) sub-surface flow constructed wetlands. The pilot-scale wetland was constructed downstream of anaerobic reactors at the campus of TUBITAK-MRC. Anaerobically pretreated wastewater was introduced into this hybrid two-stage sub-surface flow wetland system (TSCW). Wastewater was first introduced into the horizontal sub-surface flow system and then the vertical flow system before being discharged. Recirculation of the effluent was tested in the system. When the recirculation ratio was 100%, average removal efficiencies for TSCW were 91 +/- 4% for COD, 83 +/- 10% for BOD and 96 +/- 3% for suspended solids with average effluent concentrations of 9 +/- 5 mg/L COD, 6 +/- 3 mg/L BOD and 1 mg/L for suspended solids. Comparing non-recirculation and recirculation periods, the lowest effluent concentrations were obtained with a 100% recirculation ratio. The effluent concentrations met the Turkish regulations for discharge limits of COD, BOD and TSS in each case. The study showed that a hybrid constructed wetland system with recirculation is a very effective method of obtaining very low effluent organic matter and suspended solids concentrations downstream of anaerobic pretreatment of domestic wastewaters in small communities.  相似文献   

11.
This paper describes changes in effluent quality occurring before and after an upgrade to the Bolivar Wastewater Treatment Plant in South Australia. Trickling filters (TF) were replaced with an activated sludge (AS) plant, prior to tertiary treatment using waste stabilisation ponds (WSPs). The water quality in the WSPs following the upgrade was significantly improved. Reductions in total and soluble BOD, COD, TKN, suspended solids and organic nitrogen were recorded and the predominant form of inorganic nitrogen changed from NH(4)-N to NO(2)/NO(3)-N. The reduction in ammonium and potentially toxic free ammonia removed a control upon the growth of zooplankton, which may have contributed to decreases in algal biomass in the final ponds and consequently lower dissolved oxygen. Additionally, changes in inorganic nitrogen speciation contributed to a slightly elevated pH which reduced numbers of faecal coliforms in WSPs. The AS pretreated influent recorded significantly lower inorganic molar N:P ratio (10-4:1) compared to those fed with TF effluent (17-13:1). Algae within the WSPs may now be nitrogen limited, a condition which may favour the growth of nitrogen-fixing cyanobacteria. The decrease in algal biomass and in dissolved oxygen levels may enhance sedimentary denitrification, further driving the system towards nitrogen limitation.  相似文献   

12.
MBR工艺处理城镇污水处理厂污泥水中试研究   总被引:2,自引:0,他引:2  
将平板膜组件与传统脱氮除磷工艺相结合,构建了膜生物反应器强化生物脱氮除磷中试系统,并用于处理城镇污水处理厂的污泥系统废水。结果表明,出水CODCr、BOD5、NH3—N、TN和TP的平均浓度分别为70.8 mg/L、8.7 mg/L、15.1 mg/L、29.7 mg/L和0.38 mg/L,达到或接近了《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级标准。  相似文献   

13.
Two-stage membrane bioreactor (MBR) system was applied to the treatment of landfill leachate from a solid waste disposal site in Thailand. The first stage anoxic reactor was equipped with an inclined tube module for sludge separation. It was followed by an aerobic stage with a hollow fiber membrane module for solid liquid separation. Mixed liquor sludge from the aerobic reactor was re-circulated back to anoxic reactor in order to maintain constant mixed liquor suspended solids (MLSS) concentration in the aerobic reactor. The removal of micro-pollutants from landfill leachate along the treatment period of 300 days was monitored. The results indicated that two-stage MBRs could remove biochemical oxygen demand (BOD), chemical oxygen demand (COD) and NH(4)(+) by 97, 87 and 91% at steady operating condition. Meanwhile organic micro-pollutant removals were 50-76%. The removal efficiencies varied according to the hydrophobic characteristic of compounds but they were improved during long-term MBR operation without sludge discharge.  相似文献   

14.
A new type of hybrid constructed wetland (CW), consisting of both vertical-baffled flow wetland (VBFW) and horizontal subsurface flow wetland (HSFW), has been deployed in Southern China to naturally accelerate the removal of organic matter and nitrogen. The hybrid CW system is characterised by a combination of continuous baffled flow vertical wetland and 'S' pattern horizontal subsurface flow wetland with natural aeration ditches to increase the concentration of dissolved oxygen in the HSFW bed. An internal circulatory system from the HSFW effluent back to the VBFW may optionally be operated to enhance the biological denitrification effect. Cyperus alternifolius is the main macrophyte in the wetland bed. The performance of the hybrid CW was studied with a pilot-scale system and three full-scale systems for municipal sewage treatment in Southern China. The results suggest that this new hybrid CW can achieve removal efficiencies of chemical oxygen demand, suspended solids, ammonia nitrogen, total nitrogen, and total phosphorus of better than 83.6, 95.0, 71.7, 64.5 and 68.1% respectively, with a specific wetland bed area of 0.70-0.93 m(2) PE(-1). The mean effluent concentrations of these parameters would meet the regulatory discharge limits for wastewater treatment systems (GB18918, 2002) and reuse in the context of agricultural irrigation solutions in China.  相似文献   

15.
A soy protein manufacturing facility was faced with the challenge of reducing its effluent phosphorus (P) content from 20-50 mg L(-1) down to <2 mg L(-1) total P without increasing soluble salt levels to comply with discharge and receiving water requirements. A number of biological and chemical P removal technologies previously evaluated either failed to achieve the new standards or would have produced prohibitive amounts of residual sludge and unacceptably high effluent salt concentrations. Lime precipitation, utilising a novel crystallisation technology, was demonstrated through on-site pilot testing to meet the process objectives. It is capable of achieving the required P removal at pH 10 while not increasing soluble salts and producing rapid settling and filterable particles. Also, minimal carbonate removal was observed with residual solids generation being only 40% of a complete lime softening reaction. This paper describes the technical evaluation that led to the full-scale treatment system that was put into operation in late 2005.  相似文献   

16.
Ten years of full-scale experience with enhanced biological phosphorus removal (EBPR) has been evaluated. During the start-up period lack of carbon source was the main operational problem and a higher level of volatile fatty acids was secured by introducing a primary sludge hydrolysis. Acidic thermal sludge hydrolysis was used as the sludge treatment method at the plant during about three years. One effluent stream, rich in carbon and precipitant, was brought back to the process leading to an improvement of the phosphorus removal both by an improved biological process and chemical precipitation. A quite stable process of EBPR was developed with low levels of effluent phosphorus concentration. Stringent effluent discharge limits during short evaluation periods necessitated a continued work for improvement of the short-term stability. During periods with lack of carbon, such as industrial holiday or rainy periods, both simultaneous precipitation and reduced aeration have been successfully tested as strategies for securing low levels of effluent phosphorus.  相似文献   

17.
空气曝气与纯氧曝气生物滤池应用于污水深度处理的研究   总被引:3,自引:2,他引:3  
采用两种不同气源的曝气生物滤池对污水处理厂二级出水进行深度处理中试研究.结果表明,空气曝气和纯氧曝气生物滤池对COD_(Mn)的去除率相近,分别为30.5%和30.9%;以纯氧为气源的生物滤池硝化能力远强于空气曝气生物滤池,氨氮总去除率77.4%,出水氨氮为2.1~6.3 mg/L;纯氧曝气提高了滤池上部氨氮去除效果,维持滤池内溶解氧在6 mg/L以上,沿水流方向使pH逐渐下降.纯氧曝气生物滤池是污水深度处理中去除氨氮的有效工艺.  相似文献   

18.
Constructed wetlands (CWs) have been used to treat agricultural effluents with varying success especially with respect to their operational efficiency in winter and ability to retain phosphorus. Dirty water (DW) from dairy farms is a mixture of manure contaminated runoff and milk parlour washings with a highly polluting biochemical oxygen demand (BOD) < or =3000 mg/L. The initial performance a CW of a 1.2 ha horizontal flow CW consisting of five ponds in series designed to treat DW from a dairy unit was assessed over four years. Ponds were earth-lined and shallow (0.3 m) with a water residence time of 100 days and planted with five species of emergent macrophytes. In comparison to CW inflow, annual reductions were as follows: BOD 99%, P 95% and N 92.8%. Coliforms were reduced by a 10(-5) factor to natural levels. From May to October there was little CW discharge due to evaporative losses. Final effluent quality was poorest in February but remained within a regulatory effluent standard for BOD of 40 mg/L. If the CW had only four ponds (25% less surface area) effluent would have failed the BOD standard in three years.  相似文献   

19.
Common effluent treatment plants (CETPs) have been installed and are in operation at numerous industrial clusters throughout India. They serve to reduce effluent treatment cost, provide better collective treatment, and reduce land cost for small-scale industrial facilities that cannot afford individual treatment plants. Optimum working conditions for treatment of effluent to be at par with discharge standards is a major mandate for any CETP. In this study, the reliability and removal efficiencies (REs) of a CETP in the industrial area of Maharashtra State in India were examined. An established methodology was adopted to determine the effectiveness of the CETP in terms of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), and oil and grease (O&G) concentrations. The CETP's compliance with respect to design standards and its operation were studied in detail. This paper highlights the results of RE and the coefficient of determination (R2) values obtained from the CETP data, estimates the pollutants removed at the highest and lowest rates over a period of time, and highlights the reasons for problem areas along with remedial measures. It was observed that, except O&G, all the parameters (BOD, COD, and TSS) showed fluctuations in removal efficiencies and their reliabilities. This situation can be improved by releasing effluent containing hydraulic and organic loading to the CETP as per standards and optimizing treatment processes, especially primary clari-flocculators and aeration tanks, both of which are important units of any CETP.  相似文献   

20.
Effectiveness of ozonation before and after biological treatment for removal of recalcitrant organic matter in bleached kraft pulp effluents was compared. Two industrial ECF bleached eucalypt kraft pulp effluents (E1 and E2) were pretreated with 100 mg O3/L. Raw and pretreated effluents were treated biologically in bench-scale sequencing batch reactors, under constant conditions. Following biological treatment, effluents were post-treated with 100 and 200 mg O3/L. Effluent pretreatment increased effluent biodegradability by 10% in E1 and 24% in E2. Combined O3-biological treated led to small but significant increases in COD, BOD and lignin removal over biological treatment alone, but pretreatment had no significant effect on effluent colour and carbohydrate removal. Ozone pretreatment did not affect biological activity during treatment of effluent E1 but resulted in a 38% lower specific oxygen uptake rate in effluent E2. At an equivalent dose of 100 mg/L, pre-ozonation produced better quality effluent than post-ozonation, especially with regard to COD and colour. Likewise, when an equivalent dose of 200 mg/L was applied, splitting the dose equally between pre- and post-treatments was more efficient than applying the entire dose in the post-treatment. The potential for combined chemical-biological treatment to improve effluent quality has been confirmed in this study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号