首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Stroke volume can be calculated by using noninvasive Doppler techniques. The products of pulsed Doppler stroke distance of left ventricular outflow and left ventricular outflow area can often be used to calculate stroke volume. However, left ventricular outflow also moves longitudinally toward the apex of the ventricle during systole, so that zero velocity flow cannot be detected by the usual pulsed Doppler studies. We evaluated the contribution of these zero velocity flow to the noninvasive estimation of left ventricular stroke volume in 20 patients with left ventricular disease and in 20 age matched healthy controls. Left ventricular stroke distance was calculated by summing the Doppler stroke distance and the outflow long axis motion. The percentage of zero velocity flow for total stroke volume was calculated in each group. Cardiac output was also measured by thermo-dilution technique. The percentage of zero velocity flow for total noninvasive stroke volume in patients with left ventricular disease was 2.5 +/- 1.1 ml (4.0 +/- 1.5%), significantly lower than in normal subjects, 3.6 +/- 1.0 ml (5.5 +/- 1.5%) (p < 0.05). These long axis motions are significantly reduced, especially in left ventricular disease. Amplitudes of the left ventricular outflow long axis motion were correlated with Doppler stroke distance in all (r = 0.54, p < 0.01). In patients with myocardial infarction, stroke volume by thermo-dilution methods and calculated stroke volume showed good correlation both only by Doppler stroke distance (y = 1.044x + 0.547, r = 0.968) and by Doppler and long axis motion (y = 0.989x + 0.521, r = 0.974). Compared with stroke volume measured by thermodilution method, stroke volume calculated only by Doppler stroke distance was underestimated. We thus demonstrated the influence of zero velocity flow on left ventricular outflow both in patients with left ventricular disease and in normal subjects.  相似文献   

2.
This article reviews and analyzes the role of vision and spatial orientation in maintaining posture and balance. The key issues that relate to the development of postural control across the life span are discussed. Use of vision as a critical source of information that specifies spatial orientation in the environment is considered. We argue that the visual system functions as part of the perception-action cycle as promoted in ecological psychology by James Gibson. We compare and contrast theory and evidence of both standard and ecological accounts of how the visual system perceives the information and the findings relative to the role of the retinal vision in processing and acting on information related to motion. Changes in the ambient optical array (optical flow) as a non-force field are compared with gravity-based perturbations relative to the possible influence of the non-force field to changes in the motor system. Finally, a summary of some of our own work is presented, with comments about implications for further research and possible applications to clinical practice.  相似文献   

3.
Two-dimensional echocardiography for measuring left ventricular volumes usually gives volumes that are smaller than those determined with left ventriculography. This is due to less optimal image quality since manual tracing of endocardial borders requires still frames. Intravenous injection of echocontrast agent (Albunex) improve endocardial border recognition and therefore left ventricular volume measurements become more accurate. It is reported that contrast echocardiography significantly improves the correlation of echocardiographic left ventricular volume measurement with that of left ventriculography. From this points of view, contrast echocardiography is useful for the determination of left ventricular volumes in clinical settings.  相似文献   

4.
To assess the utility of double oblique, ECG-gated 1H magnetic resonance (MR) derived volume curves for assessing LV function, cardiac short axis images were acquired with a fast field echo technique. We applied this methodology to assess left ventricular function in three groups: normals, patients with left ventricular hypertrophy, and dilated cardiomyopathy. Six slices with 16-20 phases per RR interval were analyzed, representing the initial 75-80% of the cardiac cycle. For each slice, the endocardial border of the left ventricular (LV) chamber was manually traced. Using Simpson's rule, the total LV volume at a given phase was determined considering the traced area, thickness and position in three-dimensional space of each of the six constituent slices. The calculated volumes were plotted against time and the stroke volume, ejection fraction and cardiac output were determined. The volume vs time plots for the systolic and diastolic portions of the curve were individually fit to third degree polynomials using a least squares approximation. From the fit curves, the following data were extracted: the mean slope (dV/dT) during filling and emptying, and the time to 1/4, 1/3 and 1/2 filling and emptying. These parameters are valuable indices of the functional status of the myocardium; thus, accurate and useful estimates of LV function can be obtained using MRI derived volume curves in normal and abnormal states.  相似文献   

5.
6.
The effects of Amrinone on cardiac function soon after extracorporeal circulation (ECC) were studied in 5 patients including mitral valvuloplasty, VSD closure, Fontan operation and coronary AV fistel closure. In all patients, left ventricular volume load decreased postoperatively. To evaluate the efficacy, we obtained left ventricular pressure-volume loops (P-V loop) before and after ECC and after intravenous administration of Amrinone (1 mg/kg) following ECC. P-V loops were produced by measuring left ventricular pressure using a Miller catheter which was retrogradely advanced from the ascending aorta into the left ventricle and by measuring left ventricular diameter to calculate left ventricular volume with Teichholtz' formula. Although no apparent difference of Emax was recognized before and after ECC, Emax increased from 3.2 +/- 2.5 mmHg/cm3 to 5.9 +/- 4.7 mmHg/cm3 after the administration of Amrinone. The left ventricular "systolic" pressure-volume area (PVA) which is the sum of stroke work (SW) and elastic potential energy decreased from 34.4 +/- 16.4 gm to 30.9 +/- 17.8 gm after Amrinone. No difference was also recognized in left ventricular end-diastolic pressure. Ejection fraction increased from 50 +/- 17.5% to 56.1 +/- 17.3%. These results suggested that Amrinone could improve the left ventricular function without prominent change in myocardial oxygen consumption immediately after open heart surgery.  相似文献   

7.
Recent echocardiographic ABD algorithms can estimate LV volume on-line from a single long-axis plane. The objective of this study was to assess the capability and limitations of transesophageal ABD to estimate stroke volume and cardiac output in patients before and after coronary artery bypass surgery by correlating these data with simultaneous thermodilution measurements. ABD data were acquired on-line from the transverse-plane four-chamber view and the longitudinal-plane two-chamber view and calculated by automated area-length and Simpson's rule formulas for volume. Thirty-three studies were attempted in 18 patients. Technically adequate ABD data were available in all patients from at least one view. Twenty-two (67%) of 33 studies from the four-chamber view and 27 (82%) of 33 studies from the two-chamber view were technically adequate. Cardiac output by all ABD methods was significantly correlated with thermodilution values (r range 0.72 to 0.89; SEE range 0.48 to 0.55 L/min). The two-chamber view underestimated cardiac output slightly, by an average of 0.4 L/min, whereas the four-chamber view consistently underestimated cardiac output by an average of 1.9 L/min. The area-length and Simpson's rule algorithms produced similar results. Biplane transesophageal ABD is an alternative method for estimating cardiac output; the two-chamber view in particular has potential for on-line volume determination.  相似文献   

8.
BACKGROUND: The lack of a suitable noninvasive method for assessing right ventricular (RV) volume and function has been a major deficiency of two-dimensional (2D) echocardiography. The aim of our animal study was to test a new real-time three-dimensional (3D) echo imaging system for evaluating RV stroke volumes. METHODS AND RESULTS: Three to 6 months before hemodynamic and 3D ultrasonic study, the pulmonary valve was excised from 6 sheep (31 to 59 kg) to induce RV volume overload. At the subsequent session, a total of 14 different steady-state hemodynamic conditions were studied. Electromagnetic (EM) flow probes were used for obtaining aortic and pulmonic flows. A unique phased-array volumetric 3D imaging system developed at the Duke University Center for Emerging Cardiovascular Technology was used for ultrasonic imaging. Real-time volumetric images of the RV were digitally stored, and RV stroke volumes were determined by use of parallel slices of the 3D RV data set and subtraction of end-systolic cavity volumes from end-diastolic cavity volumes. Multiple regression analyses showed a good correlation and agreement between the EM-obtained RV stroke volumes (range, 16 to 42 mL/beat) and those obtained by the new real-time 3D method (r=0.80; mean difference, -2.7+/-6.4 mL/beat). CONCLUSIONS: The real-time 3D system provided good estimation of strictly quantified reference RV stroke volumes, suggesting an important application of this new 3D method.  相似文献   

9.
Both resting tachycardia and irregular ventricular rhythm may contribute to impaired cardiac performance in atrial fibrillation (AF). This study assesses the relation between resting heart rate and beat-to-beat changes in left ventricular (LV) ejection and filling in patients with normal and impaired LV systolic function. Beat-to-beat variation in LV outflow and inflow velocity-time integral was measured using pulsed Doppler ultrasound in 39 patients with chronic AF and normal (n=22) or impaired (n=17) LV systolic function. Aortic velocity-time integral variability increased with mean heart rate (p=0.003) even though RR interval variability decreased (p <0.001). Aortic velocity-time integral was more sensitive to the duration of both the preceding (p <0.001) and prepreceding (p <0.001) RR intervals at higher heart rates. These relations were similar for patients with normal and impaired LV systolic function. The sensitivity of the filling velocity-time integral to RR interval variability also increased with heart rate (p <0.001). However, at higher heart rates the filling velocity-time integral (p=0.009) and filling time (p=0.005) were less sensitive to change in RR intervals in patients with impaired LV function. We conclude that beat-to-beat stroke volume variability in AF increases with heart rate. Stroke volume variability was not influenced by LV systolic function.  相似文献   

10.
11.
The effect of pressure or volume overload on the geometry of the left ventricle (LV) was determined in order to examine the feasibility and accuracy of LV volume determinations from one minor axis or two dimensions (one minor axis and the longest length). The longest length (LL) and minor axis (MA) in both the anteroposterior (AP) view and lateral (LAT) view were determined from the LV cine silhouette in patients with normal LV volume and pressure (group 1), LV pressure (LVP) overload group (LVP greater than 140 mm Hg, group 2), and LV volume overload group (LV end-diastolic volume greater than 124% of normal, group 3). The ratio of the MA to the LL, which represents the spherical configuration of the LV, was less than "normal" in group 2, and higher than "normal" in group 3. In all groups the LV was less spherical at end-systole than at end-diastole. Additionally, the (MA)3 had a different relationship to true LV volume (biplane LV volume) in the three groups and from diastole to systole in each group. Left ventricular volume calculation from one minor axis was associated with a large error. In contrast, left ventricular volume can be accurately determined from two ventricular dimensions using either the anteroposterior or lateral ventricular image (r larger than or equal to 0.97).  相似文献   

12.
A relatively high incidence of heart failure is noted among patients with systemic lupus erythematosus (SLE) without clearly defined clinical causes. To evaluate left ventricular performance in patients with SLE without evidence of cardiovascular disease, noninvasive measurement of the systolic time intervals was carried out. Simultaneous recording of the electrocardiogram, phonocardiogram and carotid arterial pulsation were obtained in 25 patients with systemic lupus erythematosus and compared with 22 normal subjects. The patients with SLE had a shorter left ventricular ejection time (P less than 0.05), a longer pre-ejection period (P less than 0.02) and an increased ratio of pre-ejection period/left ventricular ejection time (P less than 0.005). These abnormalities on ventricular function were independent of age, duration of the disease, hypertension, renal involvement, anemia, immunologic activity and corticosteroid treatment. Several etiologic possibilities are discussed and the clinical usefulness of this method to detect and follow-up the cardiac dysfunction in systemic lupus erythematosus is emphasized.  相似文献   

13.
Early recognition of heart failure is important because early treatment reduces mortality and hospitalization rates. In screening for this disease, there is a need for a simple, safe, and cost-effective method to obtain cardiovascular variables. Therefore we developed a noninvasive impedance cardiographic method to predict the pulmonary capillary wedge pressure (PCWP) from the impedance cardiogram. The impedance cardiographic technique, though, was originally designed for stroke volume (SV) determination. The objectives of this study were to validate both variables by comparison with the paired, invasively obtained equivalents. PCWP, measured with a pulmonary artery catheter, was related to the O/C ratio from the impedance cardiogram. The O/C ratio was calculated as the amplitude of the impedance cardiogram during diastole (O) divided by the maximum height during systole (C). Stroke volume was also calculated from the impedance cardiogram according to the equation of Kubicek (SVIC) and compared with thermodilution (SVTD). Data analysis was performed in 24 stable patients who underwent diagnostic heart catheterization. Linear regression analysis showed that the O/C ratio was strongly related to the invasively measured PCWP over a range of 3 to 30 mm Hg (r = 0.92, standard error of the estimate, 3.2 mm Hg). Between SVIC and SVTD a moderate correlation was established (r = 0.69), but after exclusion of the data from patients with an aortic valve disorder (n = 5), the correlation increased considerably (r = 0.87). No significant differences between SVIC and SVTD were found (mean difference +/- 2 SD = 1.8 +/- 28.8 ml). These preliminary observations suggest that impedance cardiography can predict PCWP and measure SV over a wide range of clinically relevant values. The combined measurement of SV and PCWP by impedance cardiography might be a clinical useful tool in screening for heart failure.  相似文献   

14.
Initial evaluation has begun of a system for displaying left ventricular time-activity curves, relating the intraventricular content of radioactivity with the cardiac cycle as determined by the patient's electrocardiogram. Major problems include proper positioning of the detector, correction for background radioactivity outside the ventricle and calibration of the device to permit conversion of measurement of radioactivity to measurement of ventricular volumes.  相似文献   

15.
Cardiac volumes including left ventricular mass were determined by magnetic resonance imaging (MRI) in 30 patients using a contiguous multislice technique. Eleven patients were studied on two different days. Intra- as well as interobserver and interstudy variation were evaluated. For volume measurements the standard deviation of differences (SDD) was rather constant, independent of the size of the measured volume indicating lower percentual variability in measuring large volumes. Lowest variability was noticed for left ventricular myocardial mass estimates between observers as well as between studies. In 13 patients left ventricular mass was estimated by this technique as well as by a method using only one long axis and four short axis slices and by two-dimensional echocardiography. Although highly correlated, limits of agreement between the methods were too wide to accept interchangeable clinical use of the methods.  相似文献   

16.
17.
BACKGROUND: Originally, the authors used a combined transcranial-transmalar approach for removal of sphenoorbital tumors. METHODS: More recently, when computed tomography (CT) scanning became available, surgical management of sphenoorbital meningiomas included resection of the hyperostosis in the pterional region, orbital roof and lateral wall, and middle fossa floor. Thereafter, intradural and intraorbital components are removed, as well as infiltrated dura mater. Finally, a periosteal flap is placed over the dural defect and bone reconstructed with methylmethacrylate. RESULTS: Of 25 patients, there was only one death and all but one showed very good to moderate response to treatment. Four recurrences were observed. CONCLUSIONS: Surgical management cannot be uniform in all cases, but must be adapted to each form of presentation. On the basis of the satisfactory results achieved, we feel justified in advising the technique described above with its current modifications.  相似文献   

18.
We assessed the reliability of a continuous ambulatory radionuclide monitoring system (the VEST system, Capintec, Inc., Ramsey, NJ) for measurement of left ventricular performance during exercise in the upright and supine positions. METHODS: Sixteen healthy male volunteers (aged 32-46 yr; mean age 37 +/- 4 yr) were studied. All volunteers underwent ergometer exercise testing in both the upright and supine positions, and left ventricular performance was determined with the VEST system. RESULTS: The resting heart rate, systolic blood pressure, pressure rate product, relative end-diastolic volume, relative end-systolic volume and left ventricular ejection fraction (LVEF) all showed no differences between the upright and supine positions. At peak exercise, the heart rate, systolic blood pressure and pressure rate product showed no differences between the upright and supine positions. In the upright position at peak exercise the relative end-diastolic volume was increased (83% +/- 9% to 91% +/- 11%, p < 0.001); the relative end-systolic volume remained unchanged (34% +/- 3% to 33% +/- 15%), and LVEF was significantly increased from 58% +/- 6% to 66% +/- 11% (p < 0.01). In the supine position at peak exercise, the relative end-diastolic volume remained unchanged (85% +/- 5 to 83% +/- 7%), the relative end-systolic volume was increased (35% +/- 5% to 43% +/- 13%, p < 0.01), and LVEF was decreased from 58% +/- 5% to 48% +/- 17% (p < 0.01). These results indicated inferior data collection by the VEST system in the supine position. CONCLUSION: Since the detector of the VEST system may be too small, the data collection is impaired during exercise in the supine position by shifting the heart with deep respiration. The VEST system is very useful for determining left ventricular performance when applied in the sitting or upright position. However, in the supine position during exercise, the use of the VEST system should be avoided because it might indicate an artifactual deterioration of left ventricular performance.  相似文献   

19.
Continuous monitoring of left ventricular (LV) function during percutaneous transluminal coronary angioplasty (PTCA) was performed in 40 patients (53 +/- 2 years) with a miniature, nuclear detector system after labeling the patients' red blood cells with technetium-99m. Balloon dilation (113 seconds, range 60 to 240) induced on average a 0.12 ejection fraction (EF) unit (19%) decrease in the LVEF, which was explained by a 34% increase in end-systolic counts. Balloon dilation of the left anterior descending artery (n = 23) produced a decrease in the LVEF of 0.17 +/- 0.13 EF units compared with the decrease of 0.06 +/- 0.07 EF units in patients undergoing dilation of the left circumflex artery (n = 9) and 0.05 +/- 0.04 EF units in patients treated for a stenosis of the right coronary artery (n = 8), (p = 0.02). Balloon deflation was associated with an immediate return to pre-PTCA levels. In 10 patients with 2 identical balloon occlusions, the second occlusion led to a significantly less decrease in the LVEF (0.41 +/- 0.14 vs 0.44 +/- 0.15) and electrocardiographic ST-segment deviation (88 +/- 54 microV vs 65 +/- 42 microV) than the first. We conclude that PTCA is associated with an abrupt transient decrease in the LVEF. The effect of balloon occlusion of the left anterior descending artery is more pronounced than balloon occlusion of the left circumflex and the right coronary arteries. Neither single nor multiple balloon occlusions were associated with post-PTCA global LV dysfunction, whereas the lesser degree of LV dysfunction and electrocardiographic signs of myocardial ischemia during the second of 2 identical balloon occlusions suggests that preconditioning can be induced during PTCA.  相似文献   

20.
The study reported describes a combination of recombinant human bone morphogenetic protein-2 (rhBMP-2) and collagen (C) to regenerate bone. Unilateral critical-sized defects (CSDs) were prepared in radii of 32 skeletally mature New Zealand white rabbits. Rabbits were divided evenly among four treatments: autograft, absorbable C (Helistat), 35 microg of rhBMP-2 combined with absorbable C (rhBMP-2/C), and untreated CSDs. The two euthanasia periods were 4 and 8 weeks. Radiographs were taken the day of surgery, every 2 weeks, and at term and the percent of radiopacity was measured. Data analysis revealed a time-dependent increase in the percent radiopacity with rhBMP-2/C. Histological examination revealed the rhBMP-2/C treatment regenerated osseous contour by 8 weeks. According to quantitative histomorphometry, the CSD and C groups had significantly less new bone than either autograft or rhBMP-2/C (p < or = 0.05). The results suggest that rhBMP-2/C could be an effective therapy to restore segmental bone defects.  相似文献   