首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
The purpose of this study was to assess the relative health system costs of early hip spica cast immobilization and external fixation for pediatric femoral shaft fractures. A cost analysis was performed from the viewpoint of the study hospital and physicians using protocols based on current practice. Cost estimates were based on patient and financial information from April 1, 1993, to January 31, 1994, including the fully allocated inpatient and outpatient costs. A sensitivity analysis was conducted to analyze the effect of complications on costs. Total estimated costs (in 1994 Canadian dollars, $1.00 = $0.75 US) of uncomplicated external fixation and hip spica treatments were $7626.30 and $5970.11, respectively. Fifty percent of this difference was attributable to longer inpatient stays for the external fixation treatment. The remaining difference was because of the cost of the fixator, additional operating room staff time costs, and additional professional and technical fees. Total expected costs of treatment complicated by loss of reduction, pin tract infection, and return to the operating room were $7716.01 and $6128.44 for the external fixation and hip spica treatment options, respectively. For the range of complication probabilities considered, expected total costs were always greater with the external fixation option than with the hip spica treatment.  相似文献   

2.
Avulsion fractures of the index metacarpal at the insertion of extensor carpi radialis longus are rare. We report such a fracture and the resulting complication of division of the extensor pollicus longus tendon, by the avulsed bony fragment. Careful clinical assessment and appropriate radiological examination is needed to diagnose this rare fracture and internal fixation is recommended.  相似文献   

3.
In recent years fracture fixation in the horse has changed significantly. New devices, mainly adapted from the human field, have been successfully introduced into large animal surgery. Examples of such implants include the DCS/DHS implant system, the self-tapping screw, the cannulated screw, and the pinless external fixator. However, new devices have also been developed exclusively for equine fracture management, including the interlocking intramedullary nail and the external skeletal fixation device. With these devices the surgeon has more options for repairing fractures in horses. Nevertheless, many problems are still unsolved. Indications exist that during the next few years new, exciting fracture fixation systems will be developed, providing further advancements in the quest for the ideal implant for horses. However, the development stages of these devices are such that mentioning the possibilities here is premature.  相似文献   

4.
We did a retrospective analysis of 28 patients who were treated with the Orthofix external fixation system for complex fractures of the distal radius to study complications associated with screw size. The 14 patients in group 1 had a 4.5/3.5-mm tapered screw placed in the metacarpal bone; the 14 patients in group 2 had a 3.5/3.3-mm tapered screw placed in the metacarpal bone. Both groups had 4.5/3.5-mm tapered screws placed in the radius. Two patients in group 1 had metacarpal pin tract infections; no patients in group 2 had a distal pin tract infection. Two patients in group 1 had a fracture of the metacarpal; only one patient in group 2 had a fracture of the metacarpal. In both groups two patients had proximal pin tract infections at the radius screw fixation site. There was no screw breakage in either group. The unique design of the tapered Orthofix screw allows it to be removed almost painlessly in the clinic. At installation in the operating room, however, the surgeon must remember not to back the threaded pin out for fine adjustment of bony penetration. Any reverse excursion of the threaded shaft will loosen the tapered screw and cause early failure of the fixation. We no longer use the 4.5/3.5-mm screw when managing wrist fractures with the Orthofix external fixation system. It is now our policy to use the 3.5/3.3-mm screw for fixation of the Orthofix external frame to both the metacarpal bone and the radius.  相似文献   

5.
Bone quality, initial fracture displacement, severity of fracture comminution, accuracy of fracture reduction, and the placement of the internal fixation device are important factors that affect fixation stability. New high strength cements that are susceptible to remodeling and replacement for fracture fixation may lead to improved clinical outcome in the treatment of hip fractures. Norian SRS is an injectable, fast setting cement that cures in vivo to form an osteoconductive carbonated apatite of high compressive strength (55 MPa) with chemical and physical characteristics similar to the mineral phase of bone. It can be used as a space filling internal fixation device to facilitate the geometric reconstruction, load transfer, and healing of bone with defects and/or fractures in regions of cancellous bone. Furthermore, this cement can improve the mechanical holding strength of conventional fixation devices. Use of this material potentially could improve fracture stability, retain anatomy during fracture healing and improve hip function, thus achieving better clinical outcomes. In vivo animal studies have shown the material's biocompatibility, and cadaveric studies have shown the biomechanical advantage of its use in hip fractures. Initial clinical experience (in 52 femoral neck fractures and 39 intertrochanteric fractures) showed the potential clinical use of this innovative cement in the treatment of hip fractures.  相似文献   

6.
Superoxide as an intermediate signal for serotonin-induced mitogenesis   总被引:1,自引:0,他引:1  
BACKGROUND: Although many community hospitals and trauma centers reuse external fixator components, no published studies have examined the cost-effectiveness or the effect on the rate of complications of reuse. This study reports the preliminary results of a program for the reuse of selected components of external fixators at a trauma center. METHODS: After removal from the patient, fixators were cleaned and examined by a single nurse responsible for the program. Components in good repair were returned to the operating room stock for reuse, whereas those showing specific signs of wear were discarded. No component was used more than three times. The medical center charged patients a loaner fee equal to the hospital's cost for reusable components of external fixators. Data were collected for all fixators applied in the 15 months before and after institution of the program (69 and 65 fixators, respectively). RESULTS: The overall mean hospital charge for a fixator decreased 32% as a result of the reuse program (from $4,067 to $2,791). For the two fractures most commonly treated with external fixation, the distal radius and tibial plafond fractures, the mean charge decreased 44 and 29%, respectively. The mean hospital cost for a fixator decreased 34% as a result of the program (from $1,864 to $1,238). There were no differences in the rates of reoperation or complications before and after institution of the reuse program. No patient had mechanical failure of a new or reused fixator body. CONCLUSION: The preliminary results of this program are encouraging. We recommend that institutions reusing these devices develop specific programs outlining criteria for reuse and guidelines for reprocessing devices for reuse. The results of this study represent an important first step in the validation of the efficacy and safety of reuse of external fixator components.  相似文献   

7.
The choice of total hip arthroplasty should probably be reserved for those rare patients with preexisting osteoarthritis of the hip in the setting of a subcapital hip fracture. Additionally, relative indications for total hip arthroplasty may include the presence of contralateral hip disease; the presence of metabolic bone disease, which may controvert internal fixation or reasonable results with endoprosthetic replacement; and those patients with high activity expectations or life expectancy greater than 5 years. Given the diminished performance of hemiarthroplasty with time and activity, it may be argued that the most cost effective solution to the subcapital hip fracture in the majority of patients may be the reduction and internal fixation pathway, with elective conversion, when necessary, of the approximately 25% of patients who suffer avascular necrosis to total hip arthroplasty. It appears that hemiarthroplasty is best suited for the elderly household ambulator, whereas total hip arthroplasty is the better alternative either as the elective solution to failed internal fixation of femoral neck fractures or in the occasional community ambulator with high activity expectations and irreducible femoral neck fractures. Younger patients, and those with minimally displaced fractures, should be treated with internal fixation in an attempt to preserve the natural hip joint.  相似文献   

8.
Between 1985 and 1994, 1223 patients with malleolar fractures of the ankle were treated by open reduction and internal fixation with absorbable pins and screws, of whom 74 (6.1%) had an obvious inflammatory foreign-body reaction to the implants. Of these 74, ten later developed moderate to severe osteoarthritis of the ankle despite no evidence of incongruity of the articular surface. The implants used in these patients were made from polyglycolide, polylactide or glycolide-lactide copolymer. The joint damage seemed to be due to polymeric debris entering the articular cavity through an osteolytic extension of an implant track. The ten patients had a long clinical course which included a vigorous local foreign-body reaction, synovial irritation and subsequent degeneration. At a follow-up of three to nine years, ankle arthrodesis had been necessary in two patients and is being considered for another two. The incidence of these changes in the whole series was 0.8%, which is not high, but awareness of this possible late complication is essential.  相似文献   

9.
A case involving a displaced fracture of the ulnar condyle at the base of the second metacarpal without concomitant dislocation of the second carpometacarpal joint is described. It seems probable that the fracture was produced by simultaneous volar subluxation of the base of the third metacarpal that reduced spontaneously. Open reduction and internal fixation of the fracture with Kirschner wires achieved satisfactory results.  相似文献   

10.
The current success of the treatment of trochanteric fractures of the femur still depends on the type of fracture involved. A number of surgical procedures have proved successful in the treatment of stable fractures (e.g. dynamic hip screw, gamma nail). However, the treatment of unstable fractures remains a problem. With this type of fracture the implant is exposed to very unfavourable biomechanical loading that often leads to failure of the osteosynthesis, and makes removal of the implant necessary. In extensive tests, the biomechanical loading capacity of a new Y-nail has been investigated as a function of the stability and location of the fracture. The results show that this form of intramedullary fixing is suitable for both stable and unstable fractures. Unstable, far distal subtrochanteric fractures of the femur remain borderline indications.  相似文献   

11.
This prospective study served as a quality control of a revision concept for case of post-traumatic infection following open reduction and internal fixation in fracture treatment. It is based on clinical and microbiological criteria and has two aims: (1) eradication of the infection and avoidance of development of chronic osteitis; (2) maintenance of internal fixation, if possible. Thirty-four patients were recruited in this study. Surgical revisions were performed according to a consistent concept (debridement, irrigation, local chemotherapy, drainage) in defined time intervals (2 days). The operation site had to be bacteriologically clean after four revisions. Otherwise, the implant had to be removed. Both aims were reached in 11 cases: management of infection with maintenance of internal fixation. In 23 cases the implant material had to be removed. Nevertheless the infection was eliminated in all these patients without exception. The following risk factors for mandatory implant removal were evaluated: diabetes, arteriosclerosis, alcoholism, nicotine. This revision concept helps in the management of acute postoperative osteitis following ORIF in fracture treatment and in avoiding the development of chronic osteitis.  相似文献   

12.
STUDY DESIGN: Sixty-five patients who underwent transpedicular fixation for thoracolumbar and lumbar injuries were studied for type of injury, the severity of paralysis, the degree of postoperative correction, and instrumentation failures. OBJECTIVES: To evaluate the surgical approaches and the selection of instrumentation to determine indications for using the transpedicular fixation procedure. SUMMARY OF BACKGROUND DATA: Various transpedicular fixation devices have been used for different type of injuries, and satisfactory postoperative results were not obtained in some studies. METHODS: Forty patients had burst fractures, 19 had fracture dislocations, and six had chance-type fractures. An anterior decompression procedure was used for most cases of burst fracture and some cases of fracture dislocation where anterior compression factors were present. The Zielke or modified Zielke system was used as an internal fixator for posterior segmental fixation. RESULTS: No patient had neurologic deterioration after surgery. Twenty of 28 patients with incomplete lesions improved postoperatively according to Frankel grades. The instrumentation failed in only one patient, in whom a nonunion developed. CONCLUSION: With transpedicular fixation, it is possible to provide solid internal fixation that is circumscribed to the injured vertebral segments. The elasticity of the Zielke rod makes it an excellent transpedicular fixation device because it is easily attached and reduction is easily performed. Anterior decompression with fusion needs to be used with transpedicular fixation in the treatment of injuries (especially burst fractures).  相似文献   

13.
Recent developments in computer-assisted radiographic absorptiometry (RA) and quantitative ultrasound techniques (QUS) provide readily accessible and relatively inexpensive methods for assessing bone mineral status. However, few population-based studies have investigated the ability of RA and ultrasound to predict fracture risk prospectively. We explored the ability of RA and QUS to predict fracture risk among 560 postmenopausal women from the Hawaii Osteoporosis Study; average follow-up was 2.7 years. An incident vertebral fracture was defined as a decrease of more than 15% in vertebral heights on subsequent films. Self-reported nonspine fractures were verified by medical records. The prospective associations of vertebral fractures, nonspine fractures, and any (spine or nonspine) fractures with bone measurements were examined using logistic regression, adjusting for age. Both phalangeal bone mineral density (BMD) and metacarpal BMD, measured using RA, predicted future fracture risk. The age-adjusted odds ratios (corresponding to 1 SD decrease in BMD) for vertebral fractures, nonspine fractures, and any fractures were 3.41, 1.50, and 1.91, respectively, for phalangeal BMD, and 1.71, 1.49, 1.55, respectively for metacarpal BMD. Calcaneal broadband ultrasound attenuation (BUA) also showed significant association with fracture risk, with age-adjusted odds ratios of 1.50, 1.89, and 1.72 for vertebral fractures, nonspine fractures, and any fractures, respectively. We conclude that hand RA and calcaneal BUA are significant predictors of nonspine fracture, vertebral fracture, and overall fracture risk. The attractive features of these techniques, such as portability, relatively low cost, and ease of use, make them promising alternatives to conventional bone measurement techniques used for the assessment of fracture risk.  相似文献   

14.
OBJECTIVE: To evaluate the clinical results of comminuted patella fracture fixation after an extensile surgical approach by using a tibial tuberosity osteotomy. DESIGN: Prospective, clinical. PATIENTS: Six knees with displaced comminuted patella fractures had stable internal fixation after an osteotomy of the tibial tubercle. All had immediate postoperative continuous knee motion and were followed for an average of thirty-one months (minimum of eighteen months). OUTCOME MEASURES: Time to clinical and radiographic union, Hospital for Special Surgery (HSS) Knee Scores and comparisons with literature cohort studies. RESULTS: Clinical union of the osteotomy occurred at an average of eight weeks (range 6 to 12 weeks) and of the patella fractures at an average of eleven weeks (range 8 to 21 weeks). There was no radiographic evidence of osteotomy displacement, fracture implant loosening, migration, or failure. All patients had clinical residua, which included loss of motion, thigh muscle atrophy, and barometric complaints. HSS Knee Scores averaged 75 points with four good, one fair, and one poor result. These results were comparable to those of previously published reports of ablative surgery for this type of fracture. CONCLUSION: Comminuted patella fractures are severe injuries that usually result in some lingering morbidity. Internal fixation preserves bone stock, which facilitates future reconstructive procedures. The described tibial tuberosity osteotomy, patella eversion technique of fracture exposure improved visualization and reduction of the articular surface. The osteotomy healed in all cases and did not adversely affect the clinical results.  相似文献   

15.
The results following internal fixation of displaced subcapital femoral fractures are poorer than for undisplaced fractures and are determined by both the quality of the initial reduction and the accuracy of implant placement. In a series of 26 consecutive displaced fractures internally fixed with Richards hip pins, satisfactory reduction was achieved in only 15 hips. Accurate reduction is a prerequisite for correct screw placement and occurred in only 4 of the 11 poorly aligned fractures, as opposed to 11 of the 15 well reduced ones. A total of 10 hips required a further surgical procedure as the result of complications. These results highlight the importance of accurate fracture reduction in facilitating implant placement as well as the importance of good surgical technique rather than reliance purely upon the implant. These already common fractures are assuming increasing socioeconomic importance as the elderly population grows, and successful management is vital for both the individual patient and future demands on the health service.  相似文献   

16.
An economic evaluation of energy-absorbing flooring designed to prevent hip fractures revealed a payback period of 10 1/2 years if only direct costs avoided were evaluated and just over 11 months when direct and indirect costs were included. Cost-effectiveness ratios of less than $0 per hip fracture prevented and life year saved were also estimated.  相似文献   

17.
Volar fracture dislocation of the second and third metacarpal bases associated with acute carpal tunnel syndrome in a 17-year-old football player were treated with open reduction, via volar incision to decompress the carpal tunnel, and via a second dorsal incision for internal fixation of the fracture dislocations with Kirschner wire fixation and reinsertion of the avulsed extensor carpi radialis:longus tendon. Anatomic reduction by closed or open reduction is recommended to avoid leaving patients with a weak grip and pain over the site of the fracture.  相似文献   

18.
Although nonoperative treatment is indicated and successful for the majority of diaphyseal humeral fractures, operative intervention is indicated in several situations. Either intramedullary nail or plate fixation commonly is used for the operative management of this problem. Familiarity with the surgical techniques and application of both types (and subtypes) of implants is necessary to allow optimal treatment for the widest range of fracture patterns. In most indications for operative management, internal fixation with plates is preferred. Stable fixation, sparing adjacent joints from iatrogenic injuries, and direct visualization and protection of the radial nerve are of critical importance in maximizing postoperative function and in most cases outweight the potential advantages of a loadsharing implant inserted through a more limited incision.  相似文献   

19.
This retrospective study was performed to determine whether three or two radiographic views are necessary for intraoperative evaluation of low energy, rotational ankle fracture reduction and fixation. Four orthopaedic surgeons independently reviewed two sets of radiographs of 93 low energy, rotational ankle fractures treated by open reduction and internal fixation. The reviewers judged reduction and fixation, without measurement, as if they had been the operating surgeons. Set 1 consisted of mortise and lateral views and Set 2 consisted of anteroposterior, mortise, and lateral views. There was a 2-month interval between the review of Set 1 and Set 2. Intraobserver consistency for Sets 1 and 2 for reduction ranged from 92% to 98% and consistency for fixation ranged from 85% to 94%. These results underwent statistical testing by calculation of the kappa value. With a 95% confidence interval, the kappa value for reduction ranged from 0.376 to 0.701; the kappa value for fixation ranged from 0.598 to 0.781. The interobserver consistency for Sets 1 and 2 also was calculated. The authors conclude that fracture reduction and fixation can be assessed adequately with lateral and mortise views. The anteroposterior view can be eliminated from the standard radiographic protocol, potentially resulting in cost savings.  相似文献   

20.
Dynamic external fixation for distal radius fractures   总被引:5,自引:0,他引:5  
Thirty adult patients with closed comminuted and mostly intraarticular fractures of the distal radius were treated by closed reduction and immobilization with a dynamic external wrist fixator during a 2-year period. In 13 patients with severely comminuted and unstable fractures, additional Kirschner wires were used. After 10 to 14 days of rigid fixation in neutral position, the motion element was unlocked to allow up to 30 degrees flexion. Six weeks later, the fixator was removed. The patients then were observed for an average of 24 weeks. An excellent functional outcome was seen in 6 patients (20%), a good outcome in 20 patients (67%), and a fair outcome in 4 patients (13%). Anatomically, 15 patients (50%) had an excellent result, 14 (47%) a good outcome, and 1 (3%) a fair outcome. Only minimal loss of reduction averaging 1 degree palmar tilt was seen during mobilization. There were 2 major complications: 1 deep Kirschner wire tract infection and 1 index metacarpal fracture. Minor complications such as sensory disturbances and pin tenderness were present but recovered completely after removal of the fixator. This study provides promising data and offers an alternative method in the treatment of distal radius fractures with severe comminution. In cases with postreductive unstable fragments, additional Kirschner wires should be used to allow early mobilization of the wrist.  相似文献   