首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 136 毫秒
1.
The proton exchange membrane fuel cell (PEMFC) is promising technology for efficient power generation and has wide applications. In PEMFC development, it is important to diagnose malfunctions in a system with defective components and a PEMFC stack can act as an effective sensor to detect the various malfunctioning modes. Hence, the focus of this study is to analyze the response of a PEMFC under various malfunction conditions including humidifier, air blower, and coolant pump, catalyst layer degradation, and membrane aging based on 3D PEMFC simulations. Except for the coolant supply malfunction, other malfunctions exhibit similar behavior in terms of voltage drop and temperature rise, requiring more detailed measurement techniques such as Electrochemical Impedance Spectroscopy to identify the cause of malfunctions. In addition, measuring the relative humidity of the outlet gas may not provide sufficient information to distinguish the malfunction of the anode or cathode humidifier. The results of the study suggest fault detection and isolation methods under these malfunction conditions to prevent more severe failure of the PEMFC stack and system. An extensive multi-dimensional contour comprising temperature, relative humidity, liquid saturation, water content, and current density is also provided for the better analyzation of system malfunctioning behaviors.  相似文献   

2.
Water flooding causes severe degradation of the performance and lifetime of proton exchange membrane fuel cell (PEMFC). In this study, a novel PEMFC stack with in-built moisture coil cooling was designed and the effects of moisture coil cooling on water management in the new PEMFC stack under various operating conditions were investigated. The result showed that the performance of the PEMFC stack was significantly improved due to the moisture condensation under high current density, high operating temperature, high relative humidity and high operating pressure. The output power was increases by 21.62% (525.71 W) at 1600·mA cm−2 while the increased parasitic power was no more than 35W. Moreover, degradation of the cathode catalyst layer after 100 h operation was also reduced by using moisture coil cooling. Compared with the situation without moisture condensation, the maximum decay rate of the cathode catalyst layer thickness after 100 h operation was reduced by 13.01%. Accordingly, the novel design is valuable and can be widely used in the future design of PEMFC.  相似文献   

3.
A review of polymer electrolyte membrane fuel cell stack testing   总被引:2,自引:0,他引:2  
This paper presents an overview of polymer electrolyte membrane fuel cell (PEMFC) stack testing. Stack testing is critical for evaluating and demonstrating the viability and durability required for commercial applications. Single cell performance cannot be employed alone to fully derive the expected performance of PEMFC stacks, due to the non-uniformity in potential, temperature, and reactant and product flow distributions observed in stacks. In this paper, we provide a comprehensive review of the state-of-the art in PEMFC testing. We discuss the main topics of investigation, including single cell vs. stack-level performance, cell voltage uniformity, influence of operating conditions, durability and degradation, dynamic operation, and stack demonstrations. We also present opportunities for future work, including the need to verify the impact of stack size and cell voltage uniformity on performance, determine operating conditions for achieving a balance between electrical efficiency and flooding/dry-out, meet lifetime requirements through endurance testing, and develop a stronger understanding of degradation.  相似文献   

4.
The durability of metal plate proton exchange membrane fuel cell (PEMFC) stack is still an important factor that hinders its large-scale commercial application. In this paper, we have conducted a 1000 h durability test on a 1 kW metal plate PEMFC stack, and explored the degradation of the core components. After 1000 h of dynamic load cycles, the voltage decay percentage of the stack under the current densities of 1000 mA cm?2 is 5.67%. By analyzing the scanning electron microscopy (SEM) images, the surfaces of the metal plates are contaminated locally by organic matter precipitated from the membrane electrode assembly (MEA). The SEM images of the catalyst coated membrane (CCM) cross section indicate that the MEA has undergone severe degradation, including the agglomeration of the catalyst layer, and the thinning and perforation of the PEM. These are the main factors that cause the rapid increase in hydrogen crossover flow rate and performance decay of the PEMFC stack.  相似文献   

5.
Understanding the icing characteristics of proton-exchange membrane fuel cells (PEMFCs) is essential for optimizing their cold-start performance. This study examined the effects of start-up temperature, current density, and microporous layer (MPL) hydrophobicity on the cold-start performance and icing characteristics of PEMFCs. Further, the cold-start icing characteristics of PEMFCs were studied by testing the PEMFC output voltage, impedance, and temperature changes at different positions of the cathode gas diffusion layer. Observation of the MPL surface after cold-start failure allowed determination of the distribution of ice formation at the catalytic layer/MPL interface. At fuel cell temperatures below 0 °C, supercooled water in the cell was more likely to undergo concentrated instantaneous freezing at higher temperatures (−4 and −5 °C), whereas the cathode tended to freeze in sequence at lower temperatures (−8 °C). In addition, a more hydrophobic MPL resulted in two successive instantaneous icing phenomena in the fuel cell and improved the cold-start performance.  相似文献   

6.
The metal bipolar plates (BPs) have replaced the graphite BPs in vehicle‐used proton exchange membrane fuel cell (PEMFC) stack because of their high volume power density. To investigate the durability of metal BP stack, this paper performed a durability test of 2000 hours on a 10‐cell metal BP fuel cell stack. The degradations of the average voltage and individual cell voltage in fuel cell stack were analyzed. To investigate the degradation mechanism, the stack was disassembled and the morphologies and compositions of no. 1, no. 5, and no. 10 cells after 2000 hours were characterized by SEM, TEM, and ASS. The results indicated that at 800 mA/cm2, the voltage decay rate is 42.303 μV/hour and the voltage decay percentage of the stack is 14.34% after 2000 hours according to the linearly fitting result. According to the US Department of Energy (DOE) definition of fuel cell stack life, only the voltage decay rate of OCV and the tenth cell is lower than the maximum voltage degradation rates of 10 000 hours. The decreases of homogeneity of stack were the main reason for its performance degradation. Especially for the tenth cell, its performance has almost no drop. The main failure reason of this metal BP stack is structural design rather than metal corrosion. The losses of Pt catalyst and C supporting are the main reason of performance degradation.  相似文献   

7.
The cell performance enhancement of a proton exchange membrane fuel cell (PEMFC) has been numerically investigated with the prominence-like form catalyst layer surface of the same composition at the cathodic half-cell of a PEMFC. The geometries of the prominence-like form catalyst layer surface are assigned as one prominence, three prominences, and five prominences catalyst layer surfaces with constant distance between two prominences in the same gas diffusion layer (GDL) for the purpose of investigating the cell performance. To confine the current investigation to two-dimensional incompressible flows, we assume that the fluid flow is laminar with a low Reynolds number 15. The results indicate that the prominence-like form catalyst layer surface can effectively enhance the local cell performance of a PEMFC.  相似文献   

8.
Degradation behaviors of polymer electrolyte membrane fuel cell (PEMFC) in high current density region were investigated under Freeze/Thaw cycles. Different dehumidification scenarios namely hot purge, cold purge and no purge were adopted for comparison. Micrographs from scanning electron microscopy proved little change in catalyst-coated membrane (CCM) integrity, no delamination or segregation occurred after many freeze/thaw cycles. Cyclic Voltammetry (CV) measurement revealed reduction in electrochemical active surface area of CCM. The observed performance decay in the high current density region was mainly attributed to the increased interface contact resistance and degraded electric and gas coupling characteristics at interfaces between CCM and GDL in this paper. Meanwhile, the performance degradation under low current densities (for example 400 mA cm−2 or even lower) was mainly ascribed to the degraded characteristics of catalyst layers referring to CCM as cyclic voltammetry indicated. Proper dehumidification through gas purging is effective to maintain stable preference under subzero temperature.  相似文献   

9.
Water removal from proton exchange membrane fuel cells (PEMFC) is of great importance to improve start-up ability and mitigate cell degradation when the fuel cell operates at subfreezing temperatures. In this study, we report water removal characteristics under various shut down conditions including a dry gas-purging step. In order to estimate the dehydration level of the electrolyte membrane, the high frequency resistance of the fuel cell stack was observed. Also, a novel method for measuring the amount of residual water in the fuel cell was developed to determine the amount of water removal. The method used the phase change of liquid water and was successfully applied to examine the water removal characteristics. Based on these works, the effects of several parameters such as purging time, flow rate of purging gas, operation current, and stack temperature on the amount of residual water were investigated.  相似文献   

10.
In this study, experiments were carried out to study the effects on the performances of individual cell and stack of PEM fuel cell. In the experiment, there are four key operating conditions that affect the cell performance, and they are gas humidification temperature, cell temperature, assembled torsion, and gas flow rate. A 5-cell stack of PEMFC was used to measure the voltage and current density for individual cell in this experiment. Results reveal that the performances of the center fuel cells are relatively lower than those of the cells on both sides of the stack. It is also shown that stack performance increases with the increase in the anode humidification temperature as well as the center cell of the stack. As for the effect of cell temperature, results indicate that stack performance increases with the increase in cell temperature. It is also disclosed that the performances of individual cell and stack do not change with the increase in the anode gas stoichiometric ratio, but increase with the increase in the cathode gas stoichiometric ratio. In addition, the experiment results also show that the whole stack's performance is enhanced with the increase in the assembling torsion.  相似文献   

11.
The effects of different operating conditions on the performance and the characteristics of a high-temperature proton exchange membrane fuel cell (PEMFC) are investigated using a three-dimensional (3-D) computational fluid dynamics (CFD) fuel-cell model. This model consists of the thermal-hydraulic equations and the electrochemical equations. Different operating conditions studied in this paper include the inlet gas temperature, system pressure, and inlet gas flow rate, respectively. Corresponding experiments are also carried out to assess the accuracy of this CFD model. Under the different operating conditions, the PEMFC performance curves predicted by the model correspond well with the experimentally measured ones. The performance of PEMFC is improved as the increase in the inlet temperature, system pressure or flow rate, which is precisely captured by the CFD fuel cell model. In addition, the concentration polarization caused by the insufficient supply of fuel gas can be also simulated as the high-temperature PEMFC is operated at the higher current density. Based on the calculation results, the localized thermal-hydraulic characteristics within a PEMFC can be reasonably captured. These characteristics include the fuel gas distribution, temperature variation, liquid water saturation distribution, and membrane conductivity, etc.  相似文献   

12.
刘阳  陈奔 《太阳能学报》2023,44(2):260-268
建立基于尾氢再循环的车用PEMFC氢气系统的集总参数模型和质子交换膜燃料电池堆的二维CFD模型,瞬态模拟研究额定功率工况下尾氢排放对系统及电堆工作特性的影响。结果表明:排放过程中,阳极进气压力和进气流量等参数出现显著的波动现象,且波动幅度和波动时间与排放持续时间存在直接关系;电堆性能在排放过程中有所下降,排放结束后能迅速恢复到排放前的水平;阳极内部的水气分布在排放过程中得到明显改善。  相似文献   

13.
For a proton exchange membrane fuel cell (PEMFC), dry layer preparation was optimized and applied to fabricate a micro-porous layer (MPL) for a gas diffusion layer (GDL). The MPLs fabricated by dry layer preparation and the conventional wet layer preparation were compared by physical and electrochemical methods. The PEMFC using dry layer MPLs showed better performance than that using wet layer MPLs, especially when the cells were operated under conditions of high oxygen utilization rate and high humidification temperature of air. The mass transport properties of the GDLs with the dry layer MPLs were also better than with the wet layer MPLs, and were found to be related to the pore size distribution in GDLs. The differences in surface morphology and pore size distribution for the GDLs with the dry layer and wet layer MPLs were investigated and analyzed. The dry layer preparation for MPLs was found to be more beneficial for forming meso-pores (pore size in the range of 0.5–15 μm), which are important and advantageous for facilitating gas transport in the GDLs. Moreover, the GDLs with the dry layer MPLs exhibited better electronic conductivity and more stable hydrophobicity than those with the wet layer MPLs. The reproducibility of the dry layer preparation for MPLs was also satisfying.  相似文献   

14.
This paper is to experimentally and numerically investigate the cell performance and the localized characteristics associated with a high-temperature proton exchange membrane fuel cell (PEMFC). Three experiments are carried out in order to study the performance of the PEMFC with different operating conditions and to validate the numerical simulation model. The model proposed herein is a three-dimensional (3-D) computational fluid dynamics (CFD) non-isothermal model that essentially consists of thermal–hydraulic equations and electrochemical model. The performance curves of the PEMFC predicted by the present model agree with the experimental measured data. In addition, both the experiments and the predictions precisely demonstrate the enhanced effects of inlet gas temperature and system pressure on the PEMFC performance. Based on the simulation results, the localized characteristics within a PEMFC can be reasonably captured. These parameters include the fuel gas distribution, liquid water saturation distribution, membrane conductivity distribution, temperature variation, and current density distribution etc. As the PEMFC is operated at the higher current density, the fuel gas would be insufficiently supplied to the catalyst layer, consequently causing the decline in the generation of power density. This phenomenon is so called mass transfer limitation, which can be precisely simulated by the present CFD model.  相似文献   

15.
A two-dimensional, steady state model for proton exchange membrane fuel cell (PEMFC) is presented. The model is used to describe the effect operation conditions (current density, pressure and water content) on the water transport, ohmic resistance and water distribution in the membrane and performance of PEMFC. This model considers the transport of species and water along the porous media: gas diffusion layers (GDL) anode and cathode, and the membrane of PEMFC fuel cell.  相似文献   

16.
This study discusses the use of an additional layer in the cathode side of a proton exchange membrane fuel cell (PEMFC) for improved water management at dry conditions. The performance of fuel cells deteriorates significantly when low to no gas humidification is used. This study demonstrates that adding a non-porous material with perforations, such as stainless steel, between the cathode flow field plate and the gas diffusion layer (GDL) improves the water saturation in the cathode GDL and catalyst layer, increases the water content in the anode, and keeps the membrane hydrated. The slight voltage drop in the performance as a result of transport limitations is justifiable since the overall durability of the cell at these extreme conditions is enhanced. The results show that the perforated layer(s) enhances the operational life of the PEMFC under completely dry conditions. These extreme conditions (dry gases without humidification, 90 kPa, 75 °C) were used to accelerate the failure modes in the fuel cells.  相似文献   

17.
This paper presents a novel planar proton exchange membrane fuel cell (PEMFC) stack designed for portable electronic devices, consisting of twenty homemade membrane electrode assemblies (MEAs) arranged on a planar surface and three printed circuit boards (PCBs, including anode, interlayer and cathode PCBs) used to load these MEAs. The current collectors and electrical connectors are manufactured using printed circuit technology. The inlet holes of reaction gases are also machined on PCB substrates. The output performance tests are performed on the MEAs and the assembled planar PEMFC stack. The results show that the power densities of the MEAs and the planar PEMFC stack are 0.6 W/cm2 and 0.361 W/cm2 at rated voltage under ambient temperature and forced convection air conditions, respectively. The stability tests are also conducted on the planar PEMFC stack, and the results show no significant fluctuations in output current. The feasibility of the application of planar PEMFC stacks in portable electronic devices is preliminarily demonstrated, and the improvement directions for further improving the output performance are proposed accordingly.  相似文献   

18.
In this paper, the fuel delivery subsystem (FDS) with hydrogen recirculation and anode bleeding is applied in proton exchange membrane fuel cell (PEMFC) system, which is utilized to supply hydrogen to the anode of stack and recirculate fuel back to the supply line. As the diffusion of nitrogen from cathode to anode is inevitable in a real PEMFC during long-term operation. To prevent system performance decline due to nitrogen accumulation. Therefore, this paper firstly develops a control-oriented nonlinear dynamic FDS model involving gas diffusion. Additionally, the FDS is very sensitive to operating environment, uncontrolled operation conditions may cause stack degradation. Specifically, a method based on Monte Carlo simulation is proposed to identify the key parameter boundaries. Then the gas distribution in FDS due to nitrogen crossover is analyzed in detail. After this, a hybrid robust methodology based on sliding mode algorithm is also proposed to maintain adequate hydrogen pressure supply, suitable hydrogen and nitrogen content in the system in presence of nitrogen crossover and renewed uncertainties. Finally, the performance of the presented controller is compared with nonlinear PID (NPID) control and nonlinear multi-input-multi-output (NMIMO) control through a hardware-in-the-loop test bench. Experimental results show that the hybrid controller is accurate and suitable for control purpose, the nitrogen content is restricted to the given range and the variation of output voltage is limited to the desired boundaries, the feasibility and effectiveness are validated.  相似文献   

19.
A three-dimensional, multi-component, single-phase model is applied for analyzing the electrochemical performance of the proton exchange membrane fuel cell (PEMFC) with U-shaped channel using COMSOL Multiphysics software. To validate the numerical model, the results are compared with the experimental data available in the literature. This work numerically investigates the effects of convection and diffusion under the rib, membrane thickness, ionomer content, and current density distribution at an interface between the gas diffusion layer and the catalyst layer. These effects were not studied for a U-shaped single serpentine channel despite having several benefits such as uniform reactant distribution through convection and diffusion under the rib and the resulting uniform current generation. A total of three membranes with 2, 3.5, and 5 mil thicknesses are analyzed, and an improvement of 17% in PEMFC performance with 2 mil thickness is observed owing to a decrease in internal resistance compared to 3.5 and 5 mil. Furthermore, an ionomer volume fraction in the catalyst layer is varied from 0.3 to 0.6, and the performance enhancement of 7% is reported at 0.5 volume fraction.  相似文献   

20.
Although characteristics of the gas diffusion layer (GDL) affect the performance of a proton exchange membrane fuel cell (PEMFC), mass transfer mechanisms inside the GDL and the performance of the PEMFC have not been directly correlated. To determine the design parameters of the GDL, the effects of substrate design of the GDL on performance of a PEMFC are investigated. By adding an active carbon fiber (ACF), which has a high surface area, the substrate is designed to have a different pore size structure. The results show that steady-state and transient responses are determined by capillary pressure gradient characteristics of the GDL made by pore size distribution of the substrate. The small macro-pore functions as water-retaining passage and the large macro-pore functions as water-removal passage. It is concluded that both small and large macro-pore must be present on the substrate to facilitate its function in a wide range of operating conditions.  相似文献   