Electrochemical oxidation of oxalic acid has been investigated at bare, highly boron-doped diamond electrodes. Cyclic voltammetry and flow injection analysis with amperometric detection were used to study the electrochemical reaction. Hydrogen-terminated diamonds exhibited well-defined peaks of oxalic acid oxidation in a wide pH range. A good linear response was observed for a concentration range from 50 nM to 10 microM, with an estimated detection limit of approximately 0.5 nM (S/N = 3). In contrast, oxygen-terminated diamonds showed no response for oxalic acid oxidation inside the potential window, indicating that surface termination contributed highly to the control of the oxidation reaction. An investigation with glassy carbon electrodes was conducted to confirm the surface termination effect on oxalic acid oxidation. Although a hydrogen-terminated glassy carbon electrode showed an enhancement of signal-to-background ratio in comparison with untreated glassy carbon, less stability of the current responses was observed than that at hydrogen-terminated diamond. 相似文献
2.
The electrochemistry of histamine and serotonin in neutral aqueous media (pH 7.2) was investigated using polycrystalline, boron-doped diamond thin-film electrodes. Cyclic voltammetry, hydrodynamic voltammetry, and flow injection analysis (FIA) with amperometric detection were used to study the oxidation reactions. Comparison experiments were carried out using polished glassy carbon (GC) electrodes. At diamond electrodes, highly reproducible and well-defined cyclic voltammograms were obtained for histamine with a peak potential at 1.40 V vs SCE. The voltammetric signal-to-background ratios obtained at diamond were 1 order of magnitude higher than those obtained for GC electrodes at and above 100 microM analyte concentrations. A linear dynamic range of 3-4 orders of magnitude and a detection limit of 1 microM were observed in the voltammetric measurements. Well-defined sweep rate-dependent voltammograms were also obtained for 5-hydroxytryptamine (5-HT). The characteristics of the voltammogram indicated lack of adsorption of its oxidation products on the surface. No fouling or deactivation of the electrode was observed within the experimental time of several hours. A detection limit of 0.5 microM (signal-to-noise ratio 13.8) for histamine was obtained by use of the FIA technique with a diamond electrode. A remarkably low detection limit (10 nM) was obtained for 5-HT on diamond by the same method. Diamond electrodes exhibited a linear dynamic range from 10 nM to 100 microM for 5-HT determination and a range of 0.5-100 microM for histamine determination. The FIA response was very reproducible from film to film, and the response variability was below 7% at the actual detection limits. 相似文献
3.
Loetanantawong B Suracheep C Somasundrum M Surareungchai W 《Analytical chemistry》2004,76(8):2266-2272
Mixed-valent films of ruthenium oxide-ruthenium cyanide were electrodeposited onto glassy carbon and characterized for the electrocatalytic oxidation of tetracycline. The currents produced by tetracycline were higher than from previously reported electrode modifications or pretreatments. In H(2)SO(4) pH 1.0 + 0.5 M K(2)SO(4), the second-order rate constant for the reaction between tetracycline and the Ru(III/IV) couple of ruthenium oxide was 3 x 10(5) +/- 1 x 10(5) mol(-1) cm(3) s(-1), and the rate of charge diffusion through the films was 4.5 x 10(-7) +/- 3.5 x 10(-7) cm(2) s(-1). Reaction was localized at the film-solution interface. When used as detectors in liquid chromatography (in H(3)PO(4) pH 2.5 + 0.1 M KH(2)PO(4) + 20% CH(3)CN, E = 1.10 V vs SCE), the electrodes gave limits of detection (>3 S/N) of 0.1 ppm for tetracycline and oxytetracycline and 0.5 ppm for doxycycline and chlorotetracycline. These limits were suitable for FDA and Codex Alimentarius guidelines for tetracyclines in food. Recoveries of the four tetracyclines from sea and freshwater shrimp were in the range 73-111%, which was higher or similar to the previously reported recoveries from shrimp. 相似文献
4.
Complete monosaccharide analysis by high-performance anion-exchange chromatography with pulsed amperometric detection 总被引:1,自引:0,他引:1
Monosaccharide analysis is a critical way to profile the composition of complex carbohydrates. Methods to analyze neutral and amino sugars have been established for a long time, but methods for acidic sugars are rare. The acidic sugars, including uronic acids and sialic acids, are also important components in some complex carbohydrates. In this report, a high-performance anion-exchange chromatography method with pulsed amperometric detection was initially developed to analyze acidic sugars including different uronic acids and sialic acids. Subsequently, a method to profile complete monosaccharides, including most neutral, amino, and acidic sugars, was developed. This method has a limit of quantitation of ~12.5 × 10(-3) nmol for each sugar as well as good linearity over a wide range. This is a convenient procedure because it avoids additional derivatization of monosaccharides and has a broad application to a wide range of complex carbohydrates. The monosaccharide compositions of a variety of complex carbohydrates such as different glycosaminoglycans, alginate, fucoidan, and glycans were profiled by this comprehensive method. In addition, the hydrolysis patterns of these complex carbohydrates are discussed. 相似文献
5.
6.
Abstracts are not published in this journal
This revised version was published online in November 2006 with corrections to the Cover Date. 相似文献
7.
通过热丝化学气相沉积(HFCVD)的方法,以钽(Ta)为衬底,三氧化二硼(Be2O3)为硼源,制备掺硼金刚石(BDD)薄膜.并采用共价键合法进一步制得壳聚糖修饰BDD薄膜电极.以此修饰电极为工作电极,在0.1mol/L,pH=4的磷酸氢二钠缓冲液中对Cu2+进行检测.实验表明,Cu2+在4.0×10-7~1.0×10-... 相似文献
8.
Mineralization of bisphenol A (BPA) by anodic oxidation with boron-doped diamond (BDD) electrode 总被引:4,自引:0,他引:4
Murugananthan M Yoshihara S Rakuma T Shirakashi T 《Journal of hazardous materials》2008,154(1-3):213-220
Anodic oxidation of bisphenol A (BPA), a representative endocrine disrupting chemical, was carried out using boron-doped diamond (BDD) electrode at galvanostatic mode. The electro-oxidation behavior of BPA at BDD electrode was investigated by means of cyclic voltammetric technique. The extent of degradation and mineralization of BPA were monitored by HPLC and total organic carbon (TOC) value, respectively. The results obtained, indicate that the BPA removal at BDD depends on the applied current density (Iappl), initial concentration of BPA, pH of electrolyte and supporting medium. Galvanostatic electrolysis at BDD anode cause concomitant generation of hydroxyl radical that leads to the BPA destruction. The kinetics for the BPA degradation follows a pseudo-first order reaction with a higher rate constant 12.8x10(-5) s(-1) for higher Iappl value 35.7 mA cm(-2), indicating that the oxidation reaction is limited by Iappl control. Complete mineralization of BPA was achieved regardless of the variables and accordingly the mineralization current efficiency was calculated from the TOC removal measurements. Considering global oxidation process, the effect of supporting electrolytes has been discussed in terms of the electro generated inorganic oxidants. The better performance of BDD anode was proved on a comparative study with Pt and glassy carbon under similar experimental conditions. A possible reaction mechanism for BPA degradation involving three main aromatic intermediates, identified by GC-MS analysis, was proposed. 相似文献
9.
The analysis of chlorinated phenols (2-chlorophenol, 3-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in river water was accomplished using off-line solid-phase extraction (SPE) and capillary electrophoresis coupled with electrochemical detection. A key to the sensitive, reproducible, and stable detection of these pollutants was the use of a boron-doped diamond microelectrode in the amperometric detection mode. An off-line SPE procedure was utilized to extract and preconcentrate the pollutants prior to separation and detection, with ENVI-Chrom P, a highly cross-linked styrene-divinylbenzene copolymer, being employed as the sorbent. Pollutant recoveries in the 95-100% range with relative standard deviations of 1-4% were achieved. The diamond microelectrode provided a low and stable background current with low peak-to-peak noise. The oxidative detection of the pollutants was accomplished at +1.05 V vs Ag/AgCl without the need for electrode pretreatment. The method was evaluated in terms of the linear dynamic range, sensitivity, limit of quantitation, response precision, and response stability. A reproducible electrode response was observed during multiple injections of the chlorinated phenol solutions with a relative standard deviation of < or =5.4%. Good electrode response stability was observed over many days of continuous use with no significant electrode deactivation or fouling. The separation efficiencies for all six pollutants were greater than 170,000 plates/m. The minimum concentration detectable for all six ranged from 0.02 to 0.2 ppb (S/N > or = 3) using a 250:1 preconcentration factor. 相似文献
10.
Iridium-modified, boron-doped diamond electrodes fabricated by an ion implantation method have been developed for electrochemical detection of arsenite (As(III)). Ir+ ions were implanted with an energy of 800 keV and a dose of 10(15) ion cm(-2). An annealing treatment at 850 degrees C for 45 min in H2 plasma (80 Torr) was required to rearrange metastable diamond produced by an implantation process. Characterization was investigated by SEM, AFM, Raman, and X-ray photoelectron spectroscopy. Cyclic voltammetry and flow injection analysis with amperometric detection were used to study the electrochemical reaction. The electrodes exhibited high catalytic activity toward As(III) oxidation with the detection limit (S/N = 3), sensitivity, and linearity of 20 nM (1.5 ppb), 93 nA microM(-1) cm(-2), and 0.999, respectively. The precision for 10 replicate determinations of 50 microM As(III) was 4.56% relative standard deviation. The advantageous properties of the electrodes were its inherent stability with a very low background current. The electrode was applicable for analysis of spiked arsenic in tap water containing a significant amount of various ion elements. The results indicate that the metal-implanted method could be promising for controlling the electrochemical properties of diamond electrodes. 相似文献
11.
12.
13.
Anodically oxidized diamond electrodes have been used to oxidize disulfides, thiols, and methionine in aqueous acidic media and tested for amperometric detection of these compounds after chromatographic separation. Cyclic voltammetric signals for 1 mM glutathione disulfide (GSSG) were observed at 1.39 and 1.84 V vs SCE, the values being less positive than those of its as-deposited counterpart as well as glassy carbon electrode. The voltammetric and chronocoulometric results have indicated the high stability of the electrode with negligible adsorption. A positive shift in the peak potential with increasing pH indicated the attractive electrostatic interaction between the anodically oxidized diamond surface and the positively charged GSSG in acidic media that promoted its analytical performance. The results of the electrolysis experiments of disulfides and thiols showed that the oxidation reaction mechanism of glutathione (GSH) and GSSG involves oxygen transfer. Following separation by liquid chromatography (LC), the determination of both GSH and GSSG in rat whole blood was achieved at a constant potential (1.50 V vs Ag/AgCl), and the limits of detection for GSH and GSSG were found to be 1.4 nM (0.028 pmol) and 1.9 nM (0.037 pmol) with a linear calibration range up to 0.25 mM. These detection limits were much lower than those reported for the amperometry using Bi-PbO2 electrodes and LC-mass spectrometry, and the LC method using diamond electrodes were comparable with enzymatic assay in real sample analysis. The high response stability and reproducibility together with the possibility of regeneration of the electrode surface by on-line anodic treatment at 3 V for 30 min further support the applicability of anodically pretreated diamond for amperometric detection of disulfides. 相似文献
14.
15.
Preechaworapun A Ivandini TA Suzuki A Fujishima A Chailapakul O Einaga Y 《Analytical chemistry》2008,80(6):2077-2083
An alternative method of a protein immunosensor has been developed at boron-doped diamond (BDD) electrode material. In order to construct the base of the immunosensor, o-aminobenzoic acid (o-ABA) was electropolymerized at an electrode by cyclic voltammetry. The poly-o-ABA-modified BDD was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The XPS result found that carboxyl groups were formed at the electrode surface. The carboxyl groups were then used to covalently attach protein probes. The amperometric sensing of mouse IgG (MIgG) was selected as the model at the poly-o-ABA-modified BDD to compare to the poly-o-ABA-modified glassy carbon (GC) at the same condition. An antimouse IgG from goat (GaMIgG) was covalently immobilized at a poly-o-ABA-modified BDD electrode which used a sandwich-type alkaline phosphatase (ALP) catalyzing amperometric immunoassay with 2-phospho-L-ascorbic acid (AAP) as substrate. The ALP enzyme conjugated at the immunosensor can generate AAP to the electroactive species of ascorbic acid (AA), which can be determined by amperometric detection. The signal was found to be proportional with the quantity of MIgG. The limits of detection (LODs) of 0.30 (3 SD) and 3.50 ng mL(-1) (3 SD) for MIgG at BDD and GC electrodes were obtained. It also was found that the dynamic range of 3 orders of magnitude (1-1000 ng mL(-1)) was obtained at BDD, whereas at GC, the dynamic range was more narrow (10-500 ng mL(-1)). The method was applied to a real mouse serum sample that contains MIgG. 相似文献
16.
A chemically modified electrode has been developed as a detector for the sensitive and selective determination of thiol-containing compounds following capillary electrophoresis separation. Electrodes were constructed by entrapment of the coenzyme pyrroloquinoline quinone (PQQ) into a polypyrrole (PPy) matrix on a 245-microm graphite electrode during electropolymerization of pyrrole in the presence of PQQ. PQQ serves as an efficient biocatalyst to mediate the oxidation of thiols at a substantially reduced overpotential relative to an unmodified electrode. Furthermore, this design takes advantage of the pH-dependent reversible electrochemical properties of PQQ, which facilitates optimization of separation and detection conditions. The PQQ/PPy-modified electrode was incorporated as an end-column detector, and a separation of homocysteine, cysteine, N-acetylcysteine, and glutathione was developed. Detection limits for these four thiols were determined to be 11, 23, 104, and 134 nM, respectively, with mass detection limits ranging from 0.29 to 3.48 fmol. The PQQ/PPy electrode was also found to be very reproducible in run-to-run, day-to-day, and electrode-to-electrode comparisons. The utility of this electrode was demonstrated for the detection of cysteine in dietary supplements and human urine, resulting in excellent agreement with reported values. 相似文献
17.
18.
19.
R. Ramesham 《Journal of Materials Science》1999,34(7):1439-1445
Boron-doped polycrystalline diamond films were grown over a molybdenum substrate by a microwave plasma CVD process using a methane and hydrogen gas mixture at a pressure of 35 ± 1 Torr. Boron doping of diamond was achieved in situ by using a solid boron source while growing diamond in the CVD processxu. We have observed a negligible background current (l) for diamond by differential pulse voltammetry in 0.5 M NaCl, 0.5 M H2SO4, and 0.5 M HNO3 solutions over a wide potential range. Therefore, diamond will certainly have a use as an electrode material in electroanalytical applications to detect trace toxic/nontoxic metal ions such as cadmium, lead, copper, and silver. Differential pulse voltammetry was used to detect and evaluate the presence of lead ions in 0.5 M NaCl and cadmium ions in 0.5 M H2SO4 supporting electrolyte solution using highly conducting boron-doped diamond coated molybdenum electrode material. Furthermore, reverse differential pulse voltammetry was used to evaluate the presence of copper and silver ions in 0.5 M H2SO4 and 0.5 M HNO3 solution, respectively. Diamond electrode has been used in this study to detect metallic ions in the solution over a wide potential range that covers + 0.8 V to –0.4 V vs., SHE. 相似文献