首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this study was to develop hydroxypropyl methylcellulose (HPMC) based controlled release (CR) formulations via hot melt extrusion (HME) with a highly soluble crystalline active pharmaceutical ingredient (API) embedded In the polymer phase. HPMC is considered a challenging CR polymer for extrusion due to its high glass transition temperature (Tg), low degradation temperature, and high viscosity. These problems were partially overcome by plasticizing the HPMC with up to 40% propylene glycol (PG). Theophylline was selected as the model API. By using differential scanning calorimetry (DSC), thermal gravimetric analysis (TGA), dynamic mechanical analysis (DMA), and X-ray powder diffraction (XRPD), the physical properties of the formulations were systematically characterized. Five grades of HPMC (Methocel®) – E6, K100LV, K4M, K15M, and K100M – were tested. The extrusion trials were conducted on a 16?mm twIn screw extruder with HPMC/PG placebo and formulations containing theophylline/HPMC/PG (30:42:28, w/w/w). The dissolution results showed sustained release profiles without burst release for the HPMC K4M, K15M, and K100M formulations. The extrudates have good dissolution stability after being stressed for 2 weeks under 40°C/75% RH open dish conditions and the crystalline API form did not change upon storage. Overall, the processing windows were established for the HPMC based HME-CR formulations.  相似文献   

2.
ABSTRACT

This study investigates the effects of three factors: (1) use of a mixture of two different grades of hydroxypropyl methylcellulose (HPMC), (2) apparent viscosity, and (3) tablet hardness on drug release profiles of extended-release matrix tablets. The lot-to-lot apparent viscosity difference of HPMC K15M on in vitro dissolution was also investigated. Four test formulations were made, each containing 10% of a very water-soluble active pharmaceutical ingredient (API), 32% HPMC K15M, or a mixture of HPMC K100LV and HPMC K100M, 56% diluents, and 2% lubricants. Each formulation was made at two hardness levels. A 23 full factorial design was used to study various combinations of the three factors using eight experiments conducted in a randomized order. Dissolution studies were performed in USP apparatus I. The values of t50% (time in which 50% drug is released) and tlag (lag time, the time taken by the matrix tablet edges to get hydrated and achieve a state of quasi-equilibrium before erosion and the advance of solvent front through the matrix occur) were calculated from each dissolution profile. The similarity factor (f2) was also calculated for each dissolution profile against the target dissolution profile. A simple Higuchi-type equation was used to analyze the drug release profiles. Statistical analysis using analysis of variance (ANOVA) and similarity factor (f2) values calculated from the data indicated no significant difference among the t50% values and dissolution profiles respectively for all formulations. Within the 3.3–6 kp hardness range investigated, dissolution rates were found to be independent of tablet hardness for all the formulations. Although significantly shorter lag times were observed for the tablets formulated with low- and high-viscosity HPMC mixtures in comparison to those containing a single grade of HPMC, this change had no significant impact on the overall dissolution profiles indicated by the similarity factor f2 values. From this study it can be concluded that lot-to-lot variability in apparent viscosity of HPMC should not be a concern in achieving similar dissolution profiles. Also, results indicated that within the viscosity range studied (12,000–19,500 cps) an HPMC mixture of two viscosity grades can be substituted for another HPMC grade if the apparent viscosity is comparable. Also, the drug release is diffusion-controlled and depends mostly on the viscosity of the gel layer formed.  相似文献   

3.
This study investigates the effects of three factors: (1) use of a mixture of two different grades of hydroxypropyl methylcellulose (HPMC), (2) apparent viscosity, and (3) tablet hardness on drug release profiles of extended-release matrix tablets. The lot-to-lot apparent viscosity difference of HPMC K15M on in vitro dissolution was also investigated. Four test formulations were made, each containing 10% of a very water-soluble active pharmaceutical ingredient (API), 32% HPMC K15M, or a mixture of HPMC K100LV and HPMC K100M, 56% diluents, and 2% lubricants. Each formulation was made at two hardness levels. A 23 full factorial design was used to study various combinations of the three factors using eight experiments conducted in a randomized order. Dissolution studies were performed in USP apparatus I. The values of t50% (time in which 50% drug is released) and tlag (lag time, the time taken by the matrix tablet edges to get hydrated and achieve a state of quasi-equilibrium before erosion and the advance of solvent front through the matrix occur) were calculated from each dissolution profile. The similarity factor (f2) was also calculated for each dissolution profile against the target dissolution profile. A simple Higuchi-type equation was used to analyze the drug release profiles. Statistical analysis using analysis of variance (ANOVA) and similarity factor (f2) values calculated from the data indicated no significant difference among the t50% values and dissolution profiles respectively for all formulations. Within the 3.3-6 kp hardness range investigated, dissolution rates were found to be independent of tablet hardness for all the formulations. Although significantly shorter lag times were observed for the tablets formulated with low- and high-viscosity HPMC mixtures in comparison to those containing a single grade of HPMC, this change had no significant impact on the overall dissolution profiles indicated by the similarity factor f2 values. From this study it can be concluded that lot-to-lot variability in apparent viscosity of HPMC should not be a concern in achieving similar dissolution profiles. Also, results indicated that within the viscosity range studied (12,000-19,500 cps) an HPMC mixture of two viscosity grades can be substituted for another HPMC grade if the apparent viscosity is comparable. Also, the drug release is diffusion-controlled and depends mostly on the viscosity of the gel layer formed.  相似文献   

4.
Context: Hypromellose (HPMC) has been previously used to control drug release from mini-tablets. However, owing to poor flow, production of mini-tablets containing high HPMC levels is challenging. Directly compressible (DC) HPMC grades have been developed by Dow Chemical Company.

Objective: To compare the properties of HPMC DC (METHOCEL? K4M and K100M) with regular (REG) HPMC grades.

Method: Particle size distribution and flowability of HPMC REG and DC were evaluated. 3?mm mini-tablets, containing hydrocortisone or theophylline as model drugs and 40% w/w HPMC DC or REG were produced. Mini-tablets containing HPMC DC grades were manufactured using a rotary press simulator at forces between 2–4?kN and speeds of 5, 10, 15 or 20?rpm. Mini-tablets containing HPMC REG were produced manually.

Results and discussion: The improved flowability of HPMC DC grades, which have a narrower particle size distribution and larger particle sizes, meant that simulated large scale production of mini-tablets with good weight uniformity (CV 1.79–4.65%) was feasible. It was not possible to automatically manufacture mini-tablets containing HPMC REG due to the poor flowability of the formulations. Drug release from mini-tablets comprising HPMC DC and REG were comparable. Mini-tablets containing HPMC DC illustrated a higher tensile strength compared to mini-tablets made with HPMC REG. Mini-tablets produced with HPMC DC at different compression speeds had similar drug release profiles.

Conclusions: Production of extended release mini-tablets was successfully achieved when HPMC DC was used. Drug release rate was not influenced by the different HPMC DC grades (K4M or K100M) or production speed.  相似文献   

5.
Cellulose derivatives are the most frequently used polymers in formulations of pharmaceutical products for controlled drug delivery. The main aim of the present work was to evaluate the effect of different cellulose substitutions on the release rate of ibuprofen (IBP) from hydrophilic matrix tablets. Thus, the release mechanism of IBP with methylcellulose (MC25), hydroxypropylcellulose (HPC), and hydroxypropylmethylcellulose (HPMC K15M or K100M) was studied. In addition, the influence of the diluents lactose monohydrate (LAC) and β-cyclodextrin (β-CD) was evaluated. Distinct test formulations were prepared containing: 57.14% of IBP, 20.00% of polymer, 20.29% of diluent, 1.71% of talc lubricants, and 0.86% of magnesium stearate as lubricants. Although non-negligible drug-excipient interactions were detected from DSC studies, these were found not to constitute an incompatibility effect. Tablets were examined for their drug content, weight uniformity, hardness, thickness, tensile strength, friability, porosity, swelling, and dissolution performance. Polymers MC25 and HPC were found to be unsuitable for the preparation of this kind of solid dosage form, while HPMC K15M and K100M showed to be advantageous. Dissolution parameters such as the area under the dissolution curve (AUC), the dissolution efficiency (DE20 h), dissolution time (t 50%), and mean dissolution time (MDT) were calculated for all the formulations, and the highest MDT values were obtained with HPMC indicating that a higher value of MDT signifies a higher drug retarding ability of the polymer and vice-versa. The analysis of the drug release data was performed in the light of distinct kinetic mathematical models—Kosmeyer-Peppas, Higuchi, zero-, and first-order. The release process was also found to be slightly influenced by the kind of diluent used.  相似文献   

6.
The purpose of this study was to evaluate analytical techniques for the measurement of the glass transition temperature of HPMC and formulated solid dispersions thereof. Unmodified samples of various grades of HPMC and solid dispersions of HPMC and itraconazole produced by hot melt extrusion were analyzed by thermomechanical analysis, differential scanning calorimetry, thermally stimulated depolarization current and dielectric spectroscopy. It was found that dielectric spectroscopy offers the best accuracy and reproducibility for analysis of the base HPMC powders regardless of the substitution type or viscosity grade and that the obtained results were not frequency dependent. The results of dielectric measurements of solid dispersions prepared by hot melt extrusion were compared with predicted values of the Gordon–Taylor equation. It was found that time–temperature superposition effects and small molecule frequency dependence makes broadly applying determination of the glass transition temperature in drug dispersions by dielectric spectroscopy prohibitively difficult.  相似文献   

7.
Cellulose derivatives are the most frequently used polymers in formulations of pharmaceutical products for controlled drug delivery. The main aim of the present work was to evaluate the effect of different cellulose substitutions on the release rate of ibuprofen (IBP) from hydrophilic matrix tablets. Thus, the release mechanism of IBP with methylcellulose (MC25), hydroxypropylcellulose (HPC), and hydroxypropylmethylcellulose (HPMC K15M or K100M) was studied. In addition, the influence of the diluents lactose monohydrate (LAC) and β-cyclodextrin (β-CD) was evaluated. Distinct test formulations were prepared containing: 57.14% of IBP, 20.00% of polymer, 20.29% of diluent, 1.71% of talc lubricants, and 0.86% of magnesium stearate as lubricants. Although non-negligible drug-excipient interactions were detected from DSC studies, these were found not to constitute an incompatibility effect. Tablets were examined for their drug content, weight uniformity, hardness, thickness, tensile strength, friability, porosity, swelling, and dissolution performance. Polymers MC25 and HPC were found to be unsuitable for the preparation of this kind of solid dosage form, while HPMC K15M and K100M showed to be advantageous. Dissolution parameters such as the area under the dissolution curve (AUC), the dissolution efficiency (DE20 h), dissolution time (t 50%), and mean dissolution time (MDT) were calculated for all the formulations, and the highest MDT values were obtained with HPMC indicating that a higher value of MDT signifies a higher drug retarding ability of the polymer and vice-versa. The analysis of the drug release data was performed in the light of distinct kinetic mathematical models—Kosmeyer-Peppas, Higuchi, zero-, and first-order. The release process was also found to be slightly influenced by the kind of diluent used.  相似文献   

8.
The effect of cellulose ether polymer mixtures, containing both hydroxypropylcellulose (HPC) and hydroxypropylmethylcellulose (HPMC K15M or K100M), on ketoprofen (KTP) release from matrix tablets was investigated. In order to evaluate the compatibility between the matrix components, Raman spectroscopy, scanning electron microscopy (SEM), and X-ray powder diffraction (XRPD) experiments were performed. The results evidence the absence of significant intermolecular interactions that could eventually lead to an incompatibility between the drug and the different excipients. Formulations containing mixtures of polymers with both low and high viscosity grades were prepared by a direct compression method, by varying the polymer/polymer (w/w) ratio while keeping the drug amount incorporated in the solid dispersion constant (200?mg). The hardness values of different matrices were found within the range 113.8 to 154.9 N. HPLC analysis showed a drug content recovery between 99.3 and 102.1%, indicating that no KTP degradation occurred during the preparation process. All formulations attained a high hydration degree after the first hour, which is essential to allow the gel layer formation prior to tablet dissolution. Independent-model dissolution parameters such as t10% and t50% dissolution times, dissolution efficiency (DE), mean dissolution time (MDT), and area under curve (AUC) were calculated for all formulations. Zero-order, first-order, Higuchi, and Korsmeyer–Peppas kinetic models were employed to interpret the dissolution profiles: a predominantly Fickian diffusion release mechanism was obtained – with Korsmeyer–Peppas exponent values ranging from 0.216 to 0.555. The incorporation of HPC was thus found to play an essential role as a release modifier from HPMC containing tablets.  相似文献   

9.
本文在间歇式流化喷雾造粒床内,研究了豆粉流化造粒的颗粒生长机理和规律。考察了床层温度、过剩流化气速、料液的黏度和流率、品种尺寸、晶种量和晶种的类别等操作条件对颗粒生长速率的影响,寻找到较好的工艺操作条件。  相似文献   

10.
The purpose of this study was to apply the optimization method incorporating artificial neural network (ANN) using pH-independent release of weakly basic drug, carvedilol from HPMC-based matrix formulation. Because of weakly basic nature of carvedilol, drug shows pH-dependent solubility. The enteric polymer EUDRAGIT L100 was added formulations to overcome pH-dependent solubility of carvedilol. Effects of the Hydroxypropylmethyl cellulose (HPMC) K4M and EUDRAGIT L100 amount on drug release were investigated. For this purpose 13 kinds of formulations were prepared at three different levels of each variables. The optimization of the formulation was evaluated by using ANN method. Two formulation parameters, the amounts of HPMC K4M and Eudragit L100 at three levels (?1, 0, 1) were selected as independent/input variables. In-vitro dissolution sampling times at twelve different time points were selected as dependent/output variables. By using experimental dissolution results and amount of HPMC K4M and EUDRAGIT L100, percentage of dissolved carvedilol was predicted by ANN. Similarity factor (f2) between predicted and experimentally observed profile was calculated and f2 value was found 76.33. This value showed that there was no difference between predicted and experimentally observed drug release profile. As a result of these experiments, it was found that ANNs can be successfully used to optimize controlled release drug delivery systems.  相似文献   

11.
Objective: The aim of this study was to adjust the zidovudine (AZT) release from solid tablets to an ideal profile, by developing matrices comprising swellable polymers with nonswellable ones.

Methods: Directly compressed matrices comprised different ratios of hydroxypropylmethylcellulose K15M and K100M, ethylcellulose, and methacrylic acid (Eudragit® RS PO and Eudragit® RL PO) were prepared. Technological characterization and evaluation of the in vitro release behavior were carried out. Cell density and viability following drug exposure were evaluated by the SRB method, for the Caco-2 line, while cell morphology was assessed upon Trypan blue staining.

Results: A specific formulation containing 5% of each excipient ? HPMC K15M, HPMC K100M, Eudragit® RS PO, and Eudragit® RL PO ? was found to yield the best release profile. Application of the Korsmeyer–Peppas model to the dissolution profile evidenced that a non-Fickian (anomalous) transport is involved in the drug release. Regarding the influence of the tablets’ composition on the drug’s cytotoxic effect toward the Caco-2 cell line, a reduction of cell biomass (0–15%) was verified for the distinct AZT formulations tested, F19 having displayed the highest cytotoxicity, after 24 and 48?h of incubation. Additionally, a high reversibility of the AZT effect was observed.

Conclusions: The results showed that the simultaneous application of both hydrophilic and hydrophobic polymers can modulate the drug release process, leading to an improved efficacy and patient compliance. All AZT formulations studied were found to be cytotoxic against Caco-2 cells, F19 being the most effective one.  相似文献   

12.
以聚乙烯包装薄膜为基材、乙烯-醋酸乙烯酯(EVA)热熔胶为防滑涂层,经热喷涂和后期热处理,制备得到EVA喷涂PE防滑包装材料(E-S-PE)与热处理后EVA喷涂PE防滑包装材料(HE-S-PE)。通过扫描电镜、摩擦因数/剥离实验仪、智能电子拉力试验机进行表征,研究了喷涂定量和后续热处理工艺对材料防滑性能、黏结强度和力学性能的影响,并确定其最优喷涂定量。结果表明:E-S-PE与HE-S-PE的摩擦因数均随EVA喷涂定量的增加先增大后稳定,喷涂定量分别为40 g/m~2和70 g/m~2时,其摩擦因数较大,但其力学性能均随喷涂定量增大而整体下降,且HE-SPE的力学性能较E-S-PE的下降更明显。因此,确定该防滑材料EVA的最优喷涂定量为40 g/m~2。  相似文献   

13.
Wet granulation is mostly used process for manufacturing matrix tablets. Compared to the direct compression method, it allows for a better flow and compressibility properties of compression mixtures. Granulation, including process parameters and tableting, can influence critical quality attributes (CQAs) of hydrophilic matrix tablets. One of the most important CQAs is the drug release profile. We studied the influence of granulation process parameters (type of nozzle and water quantity used as granulation liquid) and tablet hardness on the drug release profile. Matrix tablets contained HPMC K4M hydrophilic matrix former and carvedilol as a model drug. The influence of selected HPMC characteristics on the drug release profile was also evaluated using two additional HPMC batches. For statistical evaluation, partial least square (PLS) models were generated for each time point of the drug release profile using the same number of latent factors. In this way, it was possible to evaluate how the importance of factors influencing drug dissolution changes in dependence on time throughout the drug release profile. The results of statistical evaluation show that the granulation process parameters (granulation liquid quantity and type of nozzle) and tablet hardness significantly influence the release profile. On the other hand, the influence of HPMC characteristics is negligible in comparison to the other factors studied. Using a higher granulation liquid quantity and the standard nozzle type results in larger granules with a higher density and lower porosity, which leads to a slower drug release profile. Lower tablet hardness also slows down the release profile.  相似文献   

14.
A time-delayed oral drug delivery device was investigated in which an erodible tablet (ET), sealing the mouth of an insoluble capsule, controlled the lag-time prior to drug release. The time-delayed capsule (TDC) lag-time may be altered by manipulation of the excipients used in the preparation of the ET. Erosion rates and drug release profiles from TDCs were investigated with four different excipient admixtures with lactose: calcium sulphate dihydrate (CSD), dicalcium phosphate (DCP), hydroxypropylmethyl cellulose (HPMC; Methocel® K100LV grade) and silicified microcrystalline cellulose (SMCC; Prosolv® 90 grade). Additionally, the compressibility of different insoluble coated capsules was tested at different moisture levels to determine their overall integrity and suitability for oral delivery. Erosion rates of CSD, DCP, and SMCC displayed a nonlinear relationship to their concentration, while HPMC indicated rapid first-order erosion followed by zero-order erosion, the onset of which was dependent on the HPMC concentration. Capsule integrity was confirmed to be most suitable for oral delivery when the insoluble ethyl cellulose coat was applied to a hard gelatin capsule using an organic spray coating process. T50% drug release times varied between 245 (± 33.4) and 393 (± 40.8) minutes for 8% and 20% DCP, respectively, T50% release times of 91 (± 22.1) and 167 (± 34.6) were observed for 8% and 20% CSD; both formulations showed incidence of premature drug release. The SMCC formulations showed high variability due to lamination effects. The HPMC formulations had T50% release times of 69 (± 13.9), 213 (± 25.4), and 325 (± 30.3) minutes for 15%, 24%, and 30% HPMC concentrations respectively, with no premature drug release. In conclusion, HPMC showed the highest reproducibility for a range of time-delayed drug release from the assembled capsule formulation. The method of capsule coating was confirmed to be important by investigation of the overall capsule integrity at elevated humidity levels. The erosion characteristics of ETs containing HPMC may be described by gravimetric loss. The novel time-delayed capsule device presented in this study may be assembled to include an erodible tablet with a known concentration of HPMC. A variety of suitable drugs for targeted chronopharmaceutical therapy can beincorporated into such a device, ultimately improving drug efficacy and patient compliance, and reducing harmful side effects.  相似文献   

15.
A novel process for generating agglomerates of active pharmaceutical ingredient (API) and polymer by swelling the polymer in a water/organic mixture has been developed to address formulation issues resulting from a water sensitive, high drug load API with poor powder properties. Initially, the API is dissolved in water, following which hydroxypropyl methylcellulose (HPMC) is added, resulting in the imbibing of water, along with the dissolved API, into the HPMC matrix. The addition of acetone and isopropyl acetate (anti-solvents) then causes the API to crystallize inside and on the surface of HPMC agglomerates. The process was scaled up to 20?kg scale. The agglomerates of API and HPMC generated by this process are ~350?µm diameter, robust, and have significantly better flow than the API as measured by Erweka flow testing. These agglomerates exhibit improved bulk density, acceptable chemical stability, and high compressibility. The agglomerates process well through roller compaction and tableting, with no flow or sticking issues. This process is potentially adaptable to other APIs with similar attributes.  相似文献   

16.
Preparation of microcrystalline cellulose (MCC) beads with a laboratory-scale centrifugal granulating apparatus was studied, and the pharmaceutical quality of the beads was characterized with respect to the subsequent drug layering. Five process parameters of potential importance, including rotor rotation speed X1, slit air X2, spray air pressure X3, spray air rate X4, and height of nozzle setting X5, were evaluated using a fractional factorial design (FFD 2(5-2)) as the experimental design. The responses evaluated were expected yield, mean size, size distribution, shape characteristics (including roundness, circularity, elongation, rectangularity, and modelx), and friability. All five process parameters studied were found to have an influence on the selected properties of the beads, but the effects of rotor rotation speed, slit air flow rate, and spray air rate were statistically significant (p < .05). The effect of the rotor rotation speed was found to be the most potent on all the responses studied. The results also show some significant interactions between the parameters tested. The most significant interactions were between rotor rotation speed and slit air, rotor rotation speed and spray air, and slit air and spray air.  相似文献   

17.
TiC-dispersion-strengthened Cu alloys were prepared by a two-step ball-milling (BM) process followed by sparks plasma sintering (SPS), heat treatment and hot rolling in sequence. The two-step BM process is composed of a pre-ball-milling (pre-BM) on both Ti and graphite powders as well as a subsequent homogenizing by BM together with Cu powder. Microstructure evolution analysis was performed to evaluate the effects of BM conditions on the electrical and mechanical properties of Cu-based alloys. The X-ray results revealed that titanium carbide (TiC) formed from Ti and C under high impact energy BM. Moreover, the formation of TiC during the SPS and heat treatment processes was found to more beneficial in enhancing the mechanical properties of alloy. The residual Ti in Cu matrix was found to be the predominant factor lowering the electrical conductivity of Cu–Ti–C alloys.  相似文献   

18.
The purpose of this study was to prepare sustained-release pellets of nifedipine (NSPs) based on MCC matrix. Wet-milling and extrusion-spheronization techniques were employed to prepare the microcrystals and pellets, respectively. The drug release mechanism and the influencing factors were investigated. After milled with HPMC (E5), the mean particle size of nifedipine in co-grinding mixture (CGM) was 5?μm, which is 15-fold smaller than that of raw material. DSC, X-ray powder diffraction and microscopic observation confirmed the microcrystals of drug were maintained in the CGM. With increased milling time and the content of HPMC, the dissolution rate was greatly enhanced compared with the raw material. The NSPs prepared by MCC and the CGM, which was obtained by cogrinding nifedipine with 5% HPMC solution for 210?min, exhibited sustained release pattern within 8?h. Nifedipine release from MCC-based NSPs followed the Korsmeyer model and closely related to the microstructure of pellet. High stability of NSPs was confirmed after 6 months of accelerated stability test. Using commercially available sustained product as reference, bioequivalence study in beagle dogs was executed and two formulations were bioequivalent. This sustained release pellet formulation of nifedipine was advantageous with convenient and easy scaled-up preparation process.  相似文献   

19.
Yttria-stabilized ZrO2 powders with initial sizes of 5–22 mm were chsosen as feedstock for hybrid thermal plasma deposition. At 100 kW RF input power, the microstructures of the deposited coatings varied from mostly sprayed splats to physical-vapor-deposited nanostructures when the powder feeding rate was reduced from 4 to 1 g/min. At a powder feeding rate of 2 g/min, a peculiar layered coating consisting of both structures was deposited at a rate over 50 mm/min, which is promising for the fabrication of next-generation novel thermal barrier coatings.  相似文献   

20.
The aim of this study was to investigate the granulation of piroxicam by fluidized bed hot melt method using polyethylene glycol 4000 as the hydrophilic carrier and spray dried lactose as the fluidizing substrate. The effects of the spray nozzle air flow rate, axial position of the spray nozzle and load of fluidizing substrate on granules properties were investigated using a Box Behnken factorial design. The dependent variables evaluated were the mean particle size distribution, drug content and flow properties of the granules. The granule sizes ranged from 453.5?µm to 894.7?µm and piroxicam content was above 83.2%. However, the response surface ANOVA showed that sizes and piroxicam content were not affected by the granulation conditions and microscopy evidenced the presence of piroxicam crystals on granules surface. On the other hand, ANOVA showed that the granules flow properties were affected at the significance level of 5%. Thermal and infrared analysis showed that there was no interaction of piroxicam with carriers during the process. The dissolution profile of piroxicam was remarkably improved. Therefore, the results confirm the high potential of the fluidized bed hot melt granulation technique to obtain granules with enhanced drug solubility and release rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号