Object
To propose a new arterial spin labeling (ASL) perfusion-imaging method (alternate slab width inversion recovery ASL: AIRASL) that takes advantage of the qualities of 3.0 T. 相似文献Object
The purpose of the study was to show the feasibility of a positive contrast technique GRadient echo Acquisition for Superparamagnetic particles with Positive contrast (GRASP), for a specific type of magnetic particles, designed for tumor treatment under MRI monitoring. 相似文献Objective
The objective was to establish a gagCEST protocol that would enable robust and reproducible assessment of the glycosaminoglycan (GAG) content in knee cartilage at 7 T within a clinically feasible measurement time.Materials and methods
Ten young healthy volunteers (mean age 26 years, range 24–28, five males, five females) were examined on a 7 T MR system. Informed consent was obtained from all individual participants prior to enrollment into the study. Each volunteer was measured twice for reproducibility assessment. The examined knee was immobilized using a custom-made fixation device. For the gagCEST measurement, a prototype segmented 3-D RF-spoiled gradient-echo sequence with an improved saturation scheme employing adiabatic pulses was used in a scan time of 19 min. The asymmetry of the Z-spectra (MTRasym) in selected regions of interest in knee cartilage was calculated. Differences in MTRasym between different regions were evaluated using ANOVA and the Bonferroni corrected post hoc test.Results
The improvement of the saturation scheme reduced the influence of field inhomogeneities, resulted in more uniform saturation, and allowed for good reproducibility in a reasonable measurement time (19 min), as demonstrated by an intraclass correlation coefficient of 0.77. Improved fixation helped to reduce motion artifacts. Whereas similar MTRasym values were found for weight-bearing and non-weight-bearing femoral cartilage, lower values were observed in the trochlear groove (p = 0.028), patellar (p = 0.015) and tibial cartilage (p < 0.001) when compared to non-weight-bearing femoral cartilage.Conclusion
Reasonable reproducibility and sensitivity to regional differences in GAG content suggests that the improved gagCEST protocol might be useful for assessing the biochemical changes in articular cartilage that are associated with early stages of cartilage degeneration.Objective
Use of spectroscopically-acquired spin echoes typically involves Fourier transformation of the right side of the echo while largely neglecting the left side. For sufficiently long echo times, the left side may have enough spectral resolution to offer some utility. Since the acquisition of this side is “free”, we deemed it worthy of attention and investigated the spectral properties and information content of this data.Materials and methods
Theoretical expressions for left- and right-side spectra were derived assuming Lorentzian frequency distributions. For left-side spectra, three regimes were identified based upon the relative magnitudes of reversible and irreversible transverse relaxation rates, R 2′ and R 2, respectively. Point-resolved spectroscopy (PRESS) data from muscle, fat deposit and bone marrow were acquired at 1.5 T to test aspects of the theoretical expressions.Results
For muscle water or methylene marrow resonances, left-side signals were substantially or moderately larger than right-side signals but were similar in magnitude for muscle choline and creatine resonances. Left- versus right-side spectral-peak amplitude ratios depend sensitively on the relative values of R 2 and R 2′, which can be estimated given this ratio and a right-side linewidth measurement.Conclusion
Left-side spectra can be used to augment signal-to-noise and to estimate spectral R 2 and R 2′ values under some circumstances.Object
Delta relaxation enhanced magnetic resonance (dreMR) is a new imaging technique based on the idea of cycling the magnetic field B 0 during an imaging sequence. The method determines the field dependency of the relaxation rate (relaxation dispersion dR 1/dB). This quantity is of particular interest in contrast agent imaging because the parameter can be used to determine contrast agent concentrations and increases the ability to localize the contrast agent.Materials and methods
In this paper dreMR imaging was implemented on a clinical 1.5?T MR scanner combining conventional MR imaging with fast field-cycling. Two improvements to dreMR theory are presented describing the quantification of contrast agent concentrations from dreMR data and a correction for field-cycling with finite ramp times.Results
Experiments demonstrate the use of the extended theory and show the measurement of contrast agent concentrations with the dreMR method. A second experiment performs localization of a contrast agent with a significant improvement in comparison to conventional imaging.Conclusion
dreMR imaging has been extended by a method to quantify contrast agent concentrations and improved for field-cycling with finite ramp times. Robust localization of contrast agents using dreMR imaging has been performed in a sample where conventional imaging delivers inconclusive results. 相似文献Object
Our objective was to use 7 T MRI to compare cartilage morphology (thickness) and collagen composition (T2 values) in cartilage repair patients and healthy controls.Materials and methods
We scanned the knees of 11 cartilage repair patients and 11 controls on a 7 T MRI scanner using a high-resolution, gradient-echo sequence to measure cartilage thickness and a multi-echo spin-echo sequence to measure cartilage T2 values. We used two-tailed t tests to compare cartilage thickness and T2 values in: repair tissue (RT) versus adjacent cartilage (AC); RT versus healthy control cartilage (HC); AC versus HC.Results
Mean thickness in RT, AC, HC were: 2.2 ± 1.4, 3.6 ± 1.1, 3.3 ± 0.7 mm. Differences in thickness between RT–AC (p = 0.01) and RT–HC (p = 0.02) were significant, but not AC–HC (p = 0.45). Mean T2 values in RT, AC, HC were: 51.6 ± 7.6, 40.0 ± 4.7, 45.9 ± 3.7 ms. Differences in T2 values between RT–AC (p = 0.0005), RT-HC (p = 0.04), and AC–HC (p = 0.004) were significant.Conclusion
7 T MRI allows detection of differences in morphology and collagen architecture in: (1) cartilage repair tissue compared to adjacent cartilage and (2) cartilage repair tissue compared to cartilage from healthy controls. Although cartilage adjacent to repair tissue may be normal in thickness, it can demonstrate altered collagen composition. 相似文献Objective
To demonstrate imaging performance for cardiac MR imaging at 7 T using a coil array of 8 transmit/receive dipole antennas and 16 receive loops.Materials and methods
An 8-channel dipole array was extended by adding 16 receive-only loops. Average power constraints were determined by electromagnetic simulations. Cine imaging was performed on eight healthy subjects. Geometrical factor (g-factor) maps were calculated to assess acceleration performance. Signal-to-noise ratio (SNR)-scaled images were reconstructed for different combinations of receive channels, to demonstrate the SNR benefits of combining loops and dipoles.Results
The overall image quality of the cardiac functional images was rated a 2.6 on a 4-point scale by two experienced radiologists. Imaging results at different acceleration factors demonstrate that acceleration factors up to 6 could be obtained while keeping the average g-factor below 1.27. SNR maps demonstrate that combining loops and dipoles provides a more than 50% enhancement of the SNR in the heart, compared to a situation where only loops or dipoles are used.Conclusion
This work demonstrates the performance of a combined loop/dipole array for cardiac imaging at 7 T. With this array, acceleration factors of 6 are possible without increasing the average g-factor in the heart beyond 1.27. Combining loops and dipoles in receive mode enhances the SNR compared to receiving with loops or dipoles only.Objective
To retrospectively assess perception of safety of healthy individuals working with human 7 Tesla (T) magnetic resonance imaging (MRI) scanners.Materials and methods
A total of 66 healthy individuals with a mean age of 31 ± 7 years participated in this retrospective multicentre survey study. Nonparametric correlation analysis was conducted to evaluate the relation between self-reported perception of safety and prevalence of sensory effects while working with 7 T MRI scanners for an average 47 months.Results
The results indicated that 98.5 % of the study participants had a neutral or positive feeling about safety aspects at 7 T MRI scanners. 45.5 % reported that they feel very safe and none of the participants stated that they feel moderately or very unsafe while working with 7 T MRI scanners. Perception of safety was not affected by the number of hours per week spent in the vicinity of the 7 T MRI scanner or the duration of experience with 7 T MRI. More than 50 % of individuals experienced vertigo and metallic taste while working with 7 T MRI scanners. However, participants’ perceptions of safety were not affected by the prevalence of MR-related symptoms.Conclusions
The overall data indicated an average perception of a moderately safe work environment. To our knowledge, this study delineates the first attempt to assess the subjective safety perception among 7 T MRI workers and suggests further investigations are indicated.Fluorine MR would benefit greatly from enhancements in signal-to-noise ratio (SNR). This study examines the sensitivity gain of 19F MR that can be practically achieved when moving from 9.4 to 21.1 T.
Materials and methodsWe studied perfluoro-15-crown-5-ether (PFCE) at both field strengths (B0), as a pure compound, in the form of nanoparticles (NP) as employed to study inflammation in vivo, as well as in inflamed tissue. Brains, lymph nodes (LNs) and spleens were obtained from mice with experimental autoimmune encephalomyelitis (EAE) that had been administered PFCE NPs. All samples were measured at both B0 with 2D-RARE and 2D-FLASH using 19F volume radiofrequency resonators together. T1 and T2 of PFCE were measured at both B0 strengths.
ResultsCompared to 9.4 T, an SNR gain of > 3 was observed for pure PFCE and > 2 for PFCE NPs at 21.1 T using 2D-FLASH. A dependency of 19F T1 and T2 relaxation on B0 was demonstrated. High spatially resolved 19F MRI of EAE brains and LNs at 21.1 T revealed signals not seen at 9.4 T.
DiscussionEnhanced SNR and T1 shortening indicate the potential benefit of in vivo 19F MR at higher B0 to study inflammatory processes with greater detail.
相似文献