1.
Centrifugal pumps are generally employed as nonpulsatile blood flow pumps; however, these pumps can produce pulsatile flow by periodically alternating the impeller rotation speed. This study investigates blood trauma due to the effect of pulse frequency and various ranges of pump speed. The hemolysis tests were conducted using the Gyro C1E3 pump. The study was divided into the following categories: Group 1 in a nonpulsatile mode; Group 2 operated at 40 bpm with 30% of speed variance; Group 3, 60 bpm with 30% of speed variance; Group 4, 40 bpm with 70% of speed variance; and Group 5, 60 bpm with 70% of speed variance. A flow rate of 3 L/min and a total pressure head of 200 mm Hg were employed in all groups to simulate a percutaneous cardiopulmonary support condition. There were no significant differences in the hemolysis levels among Groups 1, 2, and 3. However, Groups 4 and 5 exhibited a significantly higher hemolysis rate compared to the other groups. These results indicate that a high rate of speed variance increases hemolysis; however, a range of less than 30% does not affect hemolysis. The pulse rate has no significant effect on hemolysis. In conclusion, the higher speed variance increases the hemolysis level when a pulsatile mode is applied with a centrifugal pump at the given test conditions. However, a speed variance of less than 30% or a pulse rate of less than 60 bpm does not affect hemolysis.  相似文献   

2.
Centrifugal blood pumps are of substantial importance for intraoperative extracorporeal circulation and for temporary cardiac assist. Their development and improvement raises many specific questions, especially on mechanical blood properties, flow distribution, and the resulting biocompatibility. In this comprehensive study the influence of various pump geometries on blood trauma was investigated. For this purpose analytical calculations, hydrodynamic performance, numerical simulation, in vitro hemolysis tests and in vivo experiments were used. The gap between rotor and housing was found to be crucial showing a distinct minimum of hemolysis at a gap of 1.5 mm (in vitro increase of plasma free hemoglobin per 100 ml plasma an hour: delta fHb/hour = 2.4 +/- 0.83 mg%/h at 1.5 mm versus 12 +/- 2.2 mg%/h at 2.5 mm; p < 0.05). Housing diameter and shape of the vanes were of less importance for blood traumatization (d = 60 mm: delta fHb/hour = 6.36 +/- 1.8 mg%/h; d = 70 mm: fHb = 7.1 +/- 1.9 mg%/h; straight radial vanes: 5.2 +/- 1.8 mg%/h; straight inclined vanes: 6.8 +/- 1.2 mg%/h; flexed vanes: 6.1 +/- 2.0 mg%/h). Three animal experiments confirmed the optimization of geometry, with a mean fHb of 2.5 to 3.2 mg% in steady state. Hydrodynamic efficiency revealed to be a necessary, but not a sufficient and sensitive criterion for hemolysis minimization (e.g. changes of eta < 10% for changes of fHb > 500%). Numerical simulation gives an improved insight in flow distribution, but can not yet be applied for quantification of blood trauma.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
A compact centrifugal blood pump was developed as an implantable left ventricular assist system. The impeller diameter is 40 mm and the pump dimensions are 55 x 64 mm. This first prototype was fabricated from titanium alloy, resulting in a pump weight of 400 g including a brushless DC motor. Weight of the second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon to improve blood compatibility. Flow rates of over 7 L/min against 100 mmHg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system ("Cool-Seal") is used as a shaft seal. In this seal system, seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. The purge fluid is continuously purified and sterilized by an ultrafiltration filter incorporated into the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular apex-descending aorta bypass was performed utilizing a PTFE (Polytetrafluoroethylene) vascular graft, with the pump placed in the left thoracic cavity. In two in vivo experiments, pump flow rate was maintained at 5-8 L/min, and pump power consumption remained stable at 9-10 W. All plasma free hemoglobin levels were measured at < 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (< 0.5 ml/ day). Both animals remain under observation after 162 and 91 days of continuous pump function.  相似文献   

4.
The results of hemoglobin determination in the CSF by the method of fluorescence microscopy in 195 patients speaks in favor of relative diagnostical importance of hemoglobin in the supra fall-out CSF for establishing the character of the stroke. The following circumstances testify to this fact: 1) in an artificial admixture of blood in the CSF in some cases there may be hemolysis of "passing" erythrocytes; 2) in a genuine admixture of blood, tests of hemoglobin in the centrifugate of the CSF may be negative since in some cases the transition of hemoglobin into bilirubin in the subarachmoid space occurs more rapidly than the hemolysis of erythrocytes. Thus, the hemoglobin does not accumulate in the liquid in quantities, sufficient enough to be measured by the existing methods; 3) in a large amount of artificial blood admixture, even without a hemolysis of "passing" erythrocytes the hemoglobin tests in the centrifugate of the CSF may be positive at the expense of hemoglobin of the blood plasma.  相似文献   

5.
The surface roughness of artificial blood contacting devices is an important surface property that is closely related to blood cell trauma. The present study investigated the effect of the surface roughness of a pump housing on hemolysis in an impeller-type centrifugal blood pump, a pivot bearing supported Gyro C1E3 pump. The purpose of the study was to determine which part of a housing has the greatest surface roughness effect on hemolysis in a centrifugal pump. Seven Gyro C1E3 pumps were prepared, each with a smooth surface impeller and a housing with differing areas of altered surface roughness. Both top and bottom housings were divided into half subregions, each with the same area. Seven test pumps were produced by subjecting various subregions of the housings to vapor polishing and sandblasting. The treated surfaces were then examined by a surface profile instrument. Using these 7 pumps with different areas of altered housing roughness, in vitro hemolysis tests were performed simulating cardiopulmonary bypass (5 L/min, 350 mm Hg). The results of this study are as follows. First, the surface roughness of the top housing had a greater effect on hemolysis than that of the bottom housing. Second, on the surface of the top housing, the surface roughness of the outer half area had a greater effect on hemolysis than that of the inner half area. Third, on the surface of the bottom housing, the surface roughness of the inner half area had a greater effect on hemolysis than that of the outer half area. These findings concur with previous studies of flow patterns in pumps. Thus, it is expected that the method in this study, comparative in vitro hemolysis tests of the pumps with surfaces of the same roughness but different locations, can be used to detect the high shear area inside a pump.  相似文献   

6.
The heat and hemolysis around a shaft seal were investigated. Materials were original pumps (Nikkiso HMS-15:N-original, and 3M Delphin:D-original), vane-removed pumps (Nvane(-), Dvane(-)), and a small chamber with a shaft coiled by nichrome wire (mock pump). The original pumps were driven at 500 mmHg and 5 L/min, and vane-removed pumps were driven at the same rotation number. An electrical powers of 0, 0.5, 2, and 10 W was supplied to the mock pumps. In vitro hemolytic testing showed that hemolytic indices were 0.027 g/100 L in N-original, 0.013 in Nvane(-), 0.061 in D-original, and 0.012 in Dvane(-). Measurement of heat with a thermally insulated water chamber showed total heat within the pump of 8.62 and 10.85 W, and heat at the shaft seal of 0.87 and 0.62 W in the Nikkiso and Delphin pumps, respectively. Hemolysis and heat generation of mock pumps remained low. The results indicate that the heat generated around the shaft seal was minimal. Hemolysis at the shaft-seal was considerable but not major. Local heat did not affect hemolysis. It was concluded that the shaft-seal affected hemolysis, not by local heat but friction itself.  相似文献   

7.
It is well known that red blood cells incubated in low-density lipoprotein (LDL)-rich medium show shape abnormalities that revert to normal after reincubation in normal plasma. Patients with homozygous familial hypercholesterolemia (HFH) have an increased percentage of abnormally-shaped erythrocytes (mostly stomatocytes, knisocytes, and crenated cells) compared to normocholesterolemic controls: 7.73+/-0.96 versus 3.52+/-0.52 (mean+/-SEM; P = 0.001). To confirm the role of high LDL concentration in inducing red cell shape abnormalities we determined the percentage of abnormally shaped erythrocytes in seven HFH patients 1 day after the procedure of LDL-apheresis with a 40% cholesterol decrease. A reduction in kniscocytes, stomatocytes, and crenated cells was observed in the patients treated by LDL-apheresis (P < 0.01). To investigate the possible benefit of a reduction in erythrocyte shape abnormality on cerebral hemodynamics, cerebral flow velocity, as evaluated by transcranial Doppler, was evaluated concomitantly and found to be remarkably increased after apheresis (P < 0.01). No significant change in hematocrit, plasma viscosity, blood viscosity, mean pressure, or cardiac output was detected, 1 day after apheresis. An inverse correlation was demonstrated (r = 0.55; P = 0.04) between changes in the percentage of knisocytes+stomatocytes +crenated cells and percent changes in middle cerebral artery peak systolic velocity. The correction of erythrocyte shape abnormalities after LDL-apheresis might be related to dramatic changes in plasma phospholipid concentration and proportion occurring after this procedure in HFH patients. The reduction of erythrocyte shape abnormalities could contribute, together with other hemorheological factors, to the improvement of cerebral hemodynamics after LDL-apheresis.  相似文献   

8.
Prevention of hyperacute rejection is a difficult and unsolved problem in xenotransplantation. Natural antibodies and complement activation have been known to play an important role in the xenotransplantation between discordant species pairs. In the present study, total blood exchange (TBE) was performed with pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) solution (Ajinomoto Co., Inc., Kawasaki, Japan) before cardiac xenotransplantation in order to remove the immunoglobulins and prolong xenograft survival time. Guinea pigs and rats were used as the discordant species combination for donor and recipient. Two groups were established: Group 1, untreated control (n = 8) and Group 2, TBT with PHP solution (n = 8). The exchange blood transfusion was carried out at the rate of 15-20 ml/h utilizing PHP solution using a blood pump. After the blood exchange was processed, hematocrit (Ht) levels dropped to 4 or 5%, and a cardiac xenotransplantation was performed within 24 h. The levels of serum IgA, IgM, and IgG were decreased to less than 25, 25, and 10% of the base line, respectively, after blood exchange. A mean xenograft survival time in Group 2 was prolonged to 472 +/- 74 min and to 10.4 +/- 1.8 min in Group 1 (p < 0.01). A titer of the anti-guinea pig lymphocytotoxic antibody in rat serum was decreased to almost nil. The data from this study suggest that total blood exchange with PHP solution may be useful in preoperative removal of xenograft antibodies in xenotransplantation.  相似文献   

9.
We randomized prospectively 144 patients, undergoing elective coronary artery bypass surgery, to either early or to routine extubation [mechanical ventilatory support for 4-7 h (Group A), or 8-14 h (Group B)]. Anaesthesia was modified for both groups. The groups were well matched in terms of sex, age, NYHA class, preoperative left ventricular ejection fraction, bypass time and aortic cross-clamp time, number of grafts used, and blood units transfused. All patients had normal preoperative respiratory, renal, hepatic and cerebral functions. Mechanical ventilatory support (mean +/- SD) was 6.3 +/- 0.7 h for Group A and 11.6 +/- 1.3 h for Group B. Mean ICU stay was 17 +/- 1.3 h for Group A and 22 +/- 1.2 h for Group B, while the mean hospital stay was 7.3 +/- 0.8 days and 8.4 +/- 0.9, respectively. There were no statistically significant differences in the frequency of all postoperative complications among the two groups. There were no reintubation, readmission to the ICU or death in either group. We concluded that change in anaesthesia practice and early postoperative sedation in patients undergoing elective coronary artery bypass graft (CABG) surgery resulted in earlier tracheal extubation, shorter ICU and hospital length of stay without organ dysfunction or postoperative complications. Early extubation was only possible due to the modification of anaesthesia and ICU sedation regime.  相似文献   

10.
Because of severe hemolysis, especially on producing pulsatile flow by changing the rotating speed of the impellers, the traditional centrifugal pump was rarely used for long-term support of the failing heart. We therefore developed a motor driven pulsatile implantable impeller pump. The pulsatility was achieved by changing the rotating speed via introducing a square waveform voltage into the motor coil. The impeller vane was designed to have both radial and axial curves according to the stream surface and stream lines to reduce the thrombosis and hemolysis. Nine calves weighing 80 to 100 kg were used. With the calves under endotracheal general anesthesia, left posterolateral thoracotomy was performed to connect the inflow tube with the left atrial appendage and to anastomose the outflow tube with the descending aorta. The calves usually awoke and stood up within hours after discontinuation of anesthetics. Within 7 days, continuous monitoring of electrocardiogram, systemic and pulmonary arterial pressures, and central venous pressure were performed to adjust the pump flow to 40% to 50% of the cardiac output. During the survival of 4 to 54 days (mean 16.3 +/- 19.3 days with two calves surviving longer than 1 month), no significant deterioration of liver or renal function was noted. Because of bleeding, hemoglobin reduced from 11.4 +/- 1.8 to 9.0 +/- 1.3 g/dl, and the hematocrit decreased from 34.5 +/- 4.7 to 26.7 +/- 4.6%. No significant changes of free hemoglobin were noted. In our results, the device revealed competent pulsatile function without severe blood damage or organ dysfunction.  相似文献   

11.
12.
Besides an isomer of the cardenolide ouabain, a material with a similar HPLC retention time as ouabain but cross-reactivating with antibodies against the bufadienolide proscillaridin A and inhibiting the sodium pump is known to circulate in human blood plasma (B. SICH et al., Hypertension 27, 1073-1078 (1996).). The concentrations of both substances are known to correlate with the blood pressure. It was the intention of this work to localize tissues that contain the highest concentrations of the proscillaridin A immunoreactive material, to correlate its concentration with that of ouabain and to get information whether the concentration of this material simply reflects the number of sodium pumps of the tissue extracted. Specific antibodies for each cardiotonic steroid were used to test the tissue concentration. This report shows that in bovine tissues the distribution pattern of proscillaridin A and ouabain immunoreactivities are similar and that hypothalamus and adrenals show the highest concentrations. The cross-reactive material did not reflect the number of sodium pumps per g of wet weight tissue as measured by [3H]ouabain binding. Therefore, it is unlikely that the tissue concentrations in both immunoreactivities reflects the tissue capacity of sodium pumps labeled with cardiotonic steroids via the blood plasma. The study rather favors the concept that two different types of inhibitors of the sodium pump exist within both tissues.  相似文献   

13.
RL Macdonald  J Zhang  B Weir  LS Marton  R Wollman 《Canadian Metallurgical Quarterly》1998,42(4):825-32; discussion 832-3
OBJECTIVE: Adenosine 5'-triphosphate (ATP) causes vasoconstriction by activation of P2-purinoceptors on vascular smooth muscle cells. Erythrocytes contain ATP at a concentration (1.6 mmol/L) that contracts smooth muscle. Previous studies of hemoglobin solutions did not assess whether the vasoactivity was caused by ATP rather than or in addition to hemoglobin. It was hypothesized that the hemolysis of erythrocytes that occurs after subarachnoid hemorrhage releases ATP in concentrations that cause vasospasm. METHODS: Thirty-eight rats were randomly assigned to undergo placement of one of the following compounds in a silastic elastomer cuff around each femoral artery: 1) agarose gel (n = 8); 2) dog erythrocyte hemolysate (n = 8); 3) purified human hemoglobin (Hemolink; Hemosol, Inc., Toronto, Canada; n = 8); 4) ATP (n = 8); or 5) clotted autologous blood (n = 6). The amounts of hemoglobins and adenine nucleotides in the compounds were measured by spectrophotometry and high pressure liquid chromatography. Hemolysate, purified hemoglobin, and ATP were mixed with agarose gel to create an artificial clot. Rats were killed and fixed by perfusion at physiological blood pressure 7 days after perivascular cuff and spasmogen placement. Vasospasm was assessed by image analysis of cross sections of fixed femoral arteries. Arteries were assessed for histopathological changes on 3-point scales. RESULTS: There was significant variance in arterial diameters among groups (mean diameter +/- standard deviation: agarose gel, 0.29 +/- 0.06; purified hemoglobin, 0.28 +/- 0.04; hemolysate, 0.24 +/- 0.05; ATP, 0.25 +/- 0.05; clotted blood, 0.24 +/- 0.01; P < 0.05, analysis of variance, n = 11-20). Animals exposed to clotted blood, hemolysate that contained ATP, or ATP, developed vasospasm, whereas purified hemoglobin and agarose did not cause vasospasm. Endothelial proliferation and perivascular inflammation were more severe (P < 0.05) in arteries exposed to clotted blood, purified hemoglobin, and hemolysate. CONCLUSION: These results suggest that ATP may be a vasospastic substance released by erythrocyte hemolysis. The concentration of ATP in impure solutions of hemoglobin is too low to account for the vasoactivity of these solutions. The discrepancy between arterial narrowing and histopathological changes suggests that either histopathological changes may not be an important correlate of arterial vasospasm or that other substances are important in vasospasm.  相似文献   

14.
To examine whether hepatocytes transplanted in the spleen can function as an ectopic liver, we performed hepatocyte transplantation in rats that were rendered anhepatic. Total hepatectomy was performed by using a novel single-stage technique. Following hepatectomy, Group 1 rats (n = 16) were monitored until death to determine survival time without prior intervention. Group 2 anhepatic rats (n = 20) were sacrificed at various times to measure blood hepatocyte growth factor (HGF) and transforming growth factor beta1 (TGF-beta1) levels. Group 3 (n = 16) rats received intrasplenic injection of isolated hepatocytes (2.5 x 10(7) cells/rat) followed by total hepatectomy after 3 days. Group 4 (n = 12) sham-transplanted rats received intrasplenic saline infusion, and after 3 days they were rendered anhepatic. Group 2, 3, and 4 rats were maintained on daily Cyclosporine A (10 mg/kg; intramuscularly). Group 1 anhepatic rats survived for 22.4 +/- 5.2 hours (standard deviation). The anhepatic state was associated with a progressive and statistically significant rise in blood HGF and TGF-beta1 levels. Rats that received hepatocyte transplantation before total hepatectomy had a significantly longer survival time than sham-transplanted anhepatic controls (34.1 +/- 8.5 vs. 15.5 +/- 4.8 hrs, P < .01). Additionally, at 12 hours post-hepatectomy, transplanted rats had significantly lower blood ammonia, prothrombin time, international normalized ratio, and TGF-beta1 levels when compared with sham-transplanted controls. In conclusion, intrasplenic transplantation of allogeneic hepatocytes prolonged survival, improved blood chemistry, and lowered blood TGF-beta1 levels in rats rendered anhepatic.  相似文献   

15.
Pathomechanism of thrombocytopenia and anaemia which frequently occur in patients with malaria is of a complex origin. Anaemia occurs due to sequestrating, destruction and hemolysis of damaged, parasite infected erythrocytes, as well as of the impaired and ineffective erythropoiesis in the marrow. Thrombocytopenia in these patients may also result from both increased destruction of blood platelets and decreased thrombocytopoiesis. Similar natures of the processes cause that anaemia and thrombocytopenia frequently co-exist in patients with malaria.  相似文献   

16.
Pump manufacturers recommend setting roller pump occlusion such that the level of a 100 cm column of crystalloid drops 2.5 cm/min (Sarns, 8000 Modular Perfusion System, operator's manual, roller pump software version 2.3L. May 1993; 2.1-2.14). Though this almost occlusive setting ensures accurate pump flow, it has been shown to cause more hemolysis than nonocclusive pumps (Noon GP, Kane LE, Feldman L et al. Reduction of blood trauma in roller pumps for long-term perfusion. World J Surg 1985; 9: 65-71). We conducted a clinical study (n = 19) to compare the standard occlusion method with the dynamic method and to determine the accuracy of flow for the nonocclusive pump. Standard occlusion was set by clamping the pump tubing distal to the arterial line filter and timing the drop in pump outlet pressure as indicated by a pressure transducer connected to the filter. The occlusion setting, expressed in mmHg/s, was recorded for each roller at two specific points along the raceway. The pump was then set nonocclusively with the dynamic method using the Better Header (BH) (Circulatory Technology, Oyster Bay, NY, USA). Readings of the change in pressure in the same two selected points on the raceway were taken. The latter was repeated after discontinuation of bypass. Flow was recorded throughout the procedure from both roller pump output display and a flow meter (Model #109 Transonic, Ithaca, NY, USA). The average drop in pump outlet pressure for the standard method was 1.3 +/- 4.0 (range 0-18 mmHg/s), and for the dynamic method was 38 +/- 28 (range 1.2-89 mmHg/s). Off bypass, the average reading was 44 +/- 38 (range 2.0-103 mmHg/s). Regression analysis indicates that patient flow, when corrected for retrograde flow by the dynamic method, equals 1.003 x revolutions per minute + 40 ml/min (r2 = 0.964). The average error between indicated pump flow, corrected for retrograde flow, was -1% (range from -6.7 to 6.6%). We conclude that the BH allows nonocclusive setting (30 times less than our standard method) without sacrificing pump flow accuracy.  相似文献   

17.
BACKGROUND: White cell (WBC) reduction prior to storage of red cell (RBC) concentrates may reduce the incidence of HLA alloimmunization and may improve the quality of stored RBCs. STUDY DESIGN AND METHODS: An integrated WBC-reduction filter system was tested after various RBC preparation procedures (from whole blood), and the influence of filtration on RBCs during storage for 42 days was investigated. Four additive system RBC preparation protocols were used. Units prepared from conventional triple blood bags were held for 4 to 6 hours at 22 degrees C, and then the RBCs were separated via a hard spin and filtration, performed immediately (Group 1) or after 18 hours' storage at 4 degrees C (Group 2). Units prepared from a top-and-bottom collection system were held at 22 degrees C for 4 to 6 or 22 to 24 hours; the centrifuged RBCs were filtered immediately after preparation (Groups 3 and 4, respectively, by holding time). WBC reduction and filtration time were analyzed. The impact of WBC filtration on pH, hemolysis rate, hemoglobin content, ATP, potassium glucose, and lactate was investigated weekly during storage for 42 days. RESULTS: Filtration reduced the mean WBC count by 3 to 4 log10, to 0.19 +/- 0.25 x 10(6), regardless of the RBC preparation method. Mean filtration times differed significantly between the groups and were longest for Group 1. Besides hemolysis and pH values, which were greater in all filtered units, no major differences were found in filtered and unfiltered RBCs during the storage interval. CONCLUSION: The efficiency of prestorage WBC filtration of RBCs was unaffected by the preparation procedure. However, the filtration time for RBCs freshly prepared in the conventional triple blood bag system without buffy-coat depletion was unacceptable. No major metabolic differences between filtered and unfiltered RBCs during 42 days of storage were found.  相似文献   

18.
The authors investigated the antithombogenicity of the NASA/DeBakey axial flow ventricular assist device in an ex vivo calf model. The device is 3 inches in length and 1 inch in largest diameter. The pump weighs 53 g and displaces 15 ml. The unit consists of three major components: a flow straightener, a spinning inducer/impeller, and a diffuser. The impeller has rod shaped permanent magnets embedded within the six blades and is activated magnetically by a motor stator that is positioned outside the flow tube. Previous 2 day screening tests demonstrated an antithrombogenic configuration in short-term implantation. Based on the results of these 2 day screening tests, five pumps with the best configuration were implanted into a calf for 2 weeks for anti thrombogenicity confirmation. Pumps were implanted paracorporeally, and heparin was used to maintain activated clotting time to approximately 250 sec. Each pump was changed every 2 weeks as planned. During the experiment, all pumps demonstrated stable pumping. The required electric power was 7 to 8 watts and pump flow was maintained at 4 L/min. The calf was in excellent condition. Liver and renal function were maintained, plasma free hemoglobin was kept at less than 4 mg/dl (3.3 +/- 0.3 mg/dl), and lactate dehydrogenase was 1043 +/- 36 units/L. In this experimental series, all five pumps passed the 2 week implantation. Two week ex vivo test results indicated very slight thrombus in the hub areas of some pumps. For the next phase of the implantation study, minor design optimization is necessary to completely eliminate thrombus formation. According to our step by step approach, the in vivo test aiming for long-term implantation is ongoing.  相似文献   

19.
This study compares the effect of pulsatile (Group C, Fib/P) and nonpulsatile (Group B, Fib/NP) coronary perfusion on myocardial performance during 2 hours of normothermic ventricular fibrillation. Group A (BH/NP), used as a base-line observation, consisted of 2 hours of nonpulsatile coronary perfusion in beating hearts. The assessment of ventricular performance included diastolic ventricular compliance, myocardial oxygen consumption and lactate extraction, regional myocardial blood flow, and histology. After 120 minutes of ventricular fibrillation, Group C showed normal ventricular diastolic compliance as compared to a 50 per cent decrease in Group B (p less than 0.01). Myocardial oxygen consumption was not significantly different from that in Group B. Because of a 70 per cent increase in oxygen extraction above Group B (p less than 0.05), total left ventricular myocardial blood flow was reduced (103 +/- 23 versus 260 +/- 36 ml. per 100 Gm. per minute, p less than 0.05) and had near-constant resistance. Lactate extraction was significantly greater and more stable as compared to Group B (9.28 +/- 1.33 versus 1.8 +/- 1.08, p less than 0.05). Left ventricular endocardial/epicardial flow ratio was greater in Group C (1.21 +/- 0.08 versus 1.06 +/- 0.06, p less than 0.05). Minimal subendocardial histologic changes were present as compared to the marked patchy subendocardial ischemic changes seen in Group B. The results demonstrate that the addition of pulsatile flow to coronary perfusion minimized the deleterious effects of prolonged ventricular fibrillation on myocardial performance.  相似文献   

20.
The successful use of centrifugal pumps as temporary cardiac assist devices strongly depends on their degree of blood trauma. The mechanical stress loading experienced by cellular components on their passage through the pump is a major cause of blood trauma. Prediction of the mechanical stresses will assist optimization of pump design to minimize hemolysis and platelet activation. As a theoretical approach to this task., the determination of the complete three-dimensional (3D) flow field including all regions of high shear stress is therefore required. A computational fluid dynamics (CFD) software package, TASCflow, was used to model flow within a commercially available pump, the Aries Medical Isoflow Pump. This pump was selected in order to demonstrate the ability of the CFD software to handle complex impeller geometries. A turbulence model was included, and the Newtonian as well as the Reynolds stress tensor calculated for each nodal point. A novel aspect was the assignment of scalar stress values to streaklines representing particle paths through the pump. Scalar stress values were obtained by formulating a theory that enables the comparison of a three-dimensional state of stress with a uniaxial stress as applied in all mechanical blood damage tests. Stress loading-time functions for fluid particles passing inlet, impeller, and outlet domains of the pump were obtained. These showed that particles undergo a complex, irregularly fluctuating stress loading. Future blood damage theories would have to consider an unsteady stress loading regime that realistically reflects the flow conditions occurring within the pump.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   