1.
A sensitive gas chromatographic assay using mass selective-detection has been developed for the simultaneous quantitation of the enantiomers of (+/-)-gacyclidine (a non competitive N-methyl-D-aspartate antagonist) in human plasma. Gacyclidine enantiomers and phencyclidine (PCP), the internal standard, were extracted using a single-step liquid-liquid extraction with hexane at pH 8.0. Each enantiomer was separated on a chiral gas chromatography capillary column and specifically detected by mass spectrometry (MS) in selected-ion monitoring (SIM) mode. Gacyclidine enantiomers and PCP were monitored using the fragment ions at m/z 206 and 200, respectively. No interference was observed from endogenous components. The limit of quantitation (LOQ) for each enantiomer of gacyclidine was 300 pg/ml by using plasma samples of 500 microl. The calibration curves were linear (r2=0.998) over a range of 0.3125 to 20 ng/ml. The extraction efficiency was higher than 95% for both enantiomers. Intra- and inter-day bias were less than 10% at every standard curve concentration. Intra-day precision was less than 19% for (-)-gacyclidine and 15% for (+)-gacyclidine. Inter-day precision was below 15% for both enantiomers. The assay was validated for an enantioselective pharmacokinetic study in healthy male volunteers.  相似文献   

2.
rac-Isradipine is a dihydropyridine type calcium antagonist. Its calcium entry blocking effect is due primarily to the (+)-(S)-enantiomer. This study describes a sensitive enantioselective method for the determination of isradipine in human serum. Following alkaline extraction into hexane, the enantiomers of isradipine are separated quantitatively by high-performance liquid chromatography on a Chiralcel OJ column at 39 degrees C. The collected fractions were evaporated and assayed using capillary gas chromatography on a HP 50+ column with nitrogen selective detection. Using 2.0 ml of serum, 0.7 nmol/1 (0.26 ng/ml) of each enantiomer could be determined with acceptable precision. The method has successfully been used to measure (+)-(S)- and (-)-(R)-isradipine concentrations in samples from volunteers after intravenous and oral administration of isradipine.  相似文献   

3.
A stereoselective reversed-phase liquid chromatographic method for the determination of compounds LY300502 and LY300503 (enantiomers of LY191704) in rat and dog plasma was developed. The assay involved extraction of the compounds using a strong cation-exchange solid-phase extraction column, from which the compounds are eluted with 1% of 1 M HCI in methanol. The enantiomers were separated on a Daicel Chiralcel OD-R column. The mobile phase consisted of water-acetonitrile-methanol (50:40:10, v/v) at a flow-rate of 0.3 ml/min. UV detection was achieved at 220 nm. The disposition of the enantiomers of LY191704 in rats and dogs was found to be stereoselective and species specific.  相似文献   

4.
A sensitive and stereospecific HPLC method was developed for the analysis of (-)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-beta-cyclodextrin (S-beta-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)-absolute ethanol (80:20, v/v) containing 10 mM S-beta-CD at a flow-rate of 0.7 ml/min. Recoveries of (-)- and (+)-pentazocine were in the range of 91-93%. Linear calibration curves were obtained in the 20-400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9-7.0% and 1.2-6.2%, respectively, for the (-)-enantiomer and 0.8- 7.6% and 1.2-4.6%, respectively, for the (+)-enantiomer (n=3).  相似文献   

5.
A stereoselective and sensitive method for the determination of the enantiomers of felodipine, a dihydropyridine calcium antagonist, has been developed and the pharmacokinetic profiles of the enantiomers comparatively studied after oral administration to dogs and humans. D6-Felodipine, the internal standard, was added to the plasma, extracted with a solvent and then optically resolved into S(-) and R(+) enantiomers on a high performance liquid chromatographic Chiralcel OJ column. Each enantiomer in the effluent was analysed by capillary column gas chromatography/positive ion electron impact mass spectrometry. After oral administration of the felodipine racemate, the Tmax and t1/2 values hardly differed between the two enantiomers in dogs and humans. The Cmax and AUC0-24 h values of the S(-) enantiomer were slightly higher than those of the R(+) enantiomer in humans but the difference between the enantiomers was not significant. These results suggested that there is no large difference in the absorption, distribution and elimination of felodipine enantiomers after oral administration of the racemate in either dog or human.  相似文献   

6.
A reversed-phase isocratic high-performance liquid chromatographic method has been developed for the determination of AG-331, a novel thymidylate synthase inhibitor, in human serum and urine. The method involves a solid-phase extraction from C18 cartridges without addition of an internal standard. The methanol eluent is evaporated under nitrogen at 40 degrees C, and reconstituted in mobile phase, acetonitrile-water (35:65, v/v) containing 25 mM ammonium phosphate. Separation of AG-331 was obtained on a C18 column at a flow-rate of 1 ml/min. Chromatographic signals were monitored by a photodiode-array detector at a primary wavelength of 457 nm with a bandwidth of 4.8 nm. Standard curves are linear in the range of 22-2175 ng/ml in plasma and 44-2175 ng/ml in urine, respectively. The extraction recovery ranged from 92.9-102.4%. Intra-day coefficient of variation was less than 9.5%, and inter-day coefficient of variation was less than 14.3% for an AG-331 concentration of 44 ng/ml. This method has been used to characterize the pharmacokinetics of AG-331 in cancer patients as part of ongoing Phase I trials.  相似文献   

7.
The four stereoisomers of the combined alpha- and beta-adrenoceptor antagonist labetalol were separated and quantified at therapeutic concentrations by normal-phase high-pressure liquid chromatography using a chiral stationary phase and fluorescence detection. Drug in plasma or urine was recovered by solid-phase extraction with 83+/-5% efficiency. Limits of detection from biological samples (3 ml) were between 1.5-1.8 ng ml(-1). Intra-day and inter-day variation at 25 ng ml(-1) were < or = 2.7% and < or = 5.80% respectively for all stereoisomers. The assay was applied to an examination of the disposition of labetalol stereoisomers after a single oral dose of racemate to a human volunteer. Labetalol appears to undergo enantioselective metabolism leading to relatively low plasma concentrations of the pharmacologically active enantiomers.  相似文献   

8.
The enantioseparation of pirlindole by liquid chromatography (LC) was investigated using three different chiral stationary phases (CSPs) containing either cellulose tris-(3,5-dimethylphenylcarbamate) (Chiralcel OD-R), ovomucoid (OVM) or beta-cyclodextrin (beta-CD). The effects of the mobile phase pH on retention, enantioselectivity and resolution were studied. Methanol and acetonitrile were tested as organic modifiers while the influence of the addition to the mobile phase of sodium alkanesulfonates or sodium perchlorate was also investigated. Sodium perchlorate was only used on the Chiralcel OD-R column while sodium alkanesulfonates were tested as mobile phase additives on the three kinds of CSPs. The enantioseparation of pirlindole could be obtained on all CSPs tested, the best results with respect to chiral resolution being achieved on the Chiralcel OD-R and the OVM columns. The use of sodium octanesulfonate (NaOS) was found to improve the enantioseparation of pirlindole on the OVM column while enantioselectivity was considerably enhanced by addition of sodium perchlorate on the Chiralcel OD-R column.  相似文献   

9.
A clean-up procedure to obtain a minimal detectable concentration of 5-10 ng bupivacaine enantiomer per milliliter human plasma is described. The procedure consists of precipitation of plasma proteins using acetonitrile, followed by solid-phase extraction using a cyano column. The eluate is then made alkaline, and bupivacaine is extracted using n-hexane. After evaporation of n-hexane, the residue is redissolved in the eluent used for HPLC analysis. The HPLC method has been described previously. The minimal detectable concentrations using this method are ca. 8 and 10 ng/ml for R-(+)- and S-(-)-bupivacaine, respectively. For both enantiomers, r2 is > 0.995 over the range of 9.5-760 ng/ml enantiomer.  相似文献   

10.
An HPLC method was developed and validated for the determination in human plasma and urine of the enantiomers of eliprodil, (+/-)-alpha-(4-chlorophenyl)-4[(4-fluorophenyl) methyl]piperidine-1-ethanol hydrochloride, a new anti-ischaemic agent administered as a racemate. Both enantiomers are present in human plasma in unchanged and glucuroconjugated form, whereas only the glucuroconjugated form is excreted into urine; as a consequence, such metabolites in human plasma and urine should be submitted to enzymatic deconjugation with beta-glucuronidase (Escherichia coli) before being extracted. The general method involves a liquid-liquid extraction of eliprodil and internal standard from alkalinized plasma or urine with n-hexane, evaporation of the organic phase and derivatization with (S)-(+)-naphthylethyl isocyanate to give carbamate diastereoisomeric derivatives of (S)-(+)- and (R)-(-)-eliprodil and internal standard; after evaporation of the derivatizing mixture and dissolution of the residue in a small volume of phosphate buffer-acetonitrile (60:40, v/v), an aliquot is injected into a column-switching HPLC system. The derivatized sample extract is purified on a precolumn filled with C8-bonded silica material, which is flushed with acetonitrile-water, then diastereoisomers of eliprodil and the internal standard are automatically transferred by the mobile phase to the analytical column. The analytical column is a C8 type, specially deactivated for basic compounds, the mobile phase is 0.025 M phosphate buffer (pH 2.6)-methanol-acetonitrile (42:2:56) at a flow-rate of 1.2 ml min-1 and fluorimetric detector operating at lambda ex = 275 nm and lambda em = 336 nm is used. The retention times, under these conditions, are about 16 and 17 min for (S)-(+)- and (R)-(-)-eliprodil diastereoisomers, respectively, and about 19 min for the first-eluted diastereoisomer of the internal standard. During the analysis time, the precolumn, reset in a different path from that of the analytical column, is back-flushed with different solvents, then re-equilibrated with acetonitrile-water before the next injection. Linearity in plasma, for unchanged eliprodil enantiomers, was assessed in the range 0.15-10 ng ml-1 and for total eliprodil enantiomers (unchanged + conjugated) in the range 0.75-500 ng ml-1; the limit of quantitation (LOQ) is 0.15 ng ml-1 for each unchanged enantiomer and 0.75 ng ml-1 for each total enantiomer. Linearity was also assessed in urine for total (conjugated) eliprodil enantiomers in the range 50-25 000 ng ml-1; the LOQ is 50 ng ml-1 for each enantiomer. The intra- and inter-day precision and accuracy of the method were investigated in plasma and urine and found to be satisfactory for pharmacokinetic studies. The method has been extensively used in pharamcokinetic studies in man treated with a 20-mg dose of eliprodil racemate and some results of this application are reported.  相似文献   

11.
A method is described for the measurement of 5,5-diphenylbarbituric acid in plasma using high-performance liquid chromatography with UV detection. Briefly, the compounds are separated on a C18 reversed-phase column using a mobile phase of 50 mM sodium acetate (pH 4.5) and methanol. The flow-rate is 1.0 ml/min and 25 microl are injected and detected at 215 nm. The method is specific and sensitive in the range of concentrations tested, with a limit of quantification of 0.25 microg/ml. The calibration curves are linear for concentrations between 0.25 and 10 microg/ml. Intra-day and inter-day coefficients of variation are less than 8.5 and 10.5%, respectively, over the linear range. Intra-day and inter-day bias are less than 7.0 and 8.0%, respectively. A pharmacokinetic study conducted in male Beagle dogs administered 10 mg/kg of 1,3-dimethoxymethyl-5,5-diphenylbarbituric acid or 8 mg/kg of 5,5-diphenylbarbituric acid intravenously demonstrates the utility of this method.  相似文献   

12.
A sensitive HPLC method with piroxicam as internal standard was developed for assaying amphotericin B in plasma and tissue. An Ultrabase-C18 column and a simple mobile phase consisting of an acetonitrile-acetic acid (10%)-water (41:43:16) mixture were used. The flow-rate was 1 ml/min and the effluent was monitored at 405 nm. The linearity of the assay method was up to 1000 ng/ml and 100 micrograms/g for plasma and tissue, respectively. Intra-day and inter-day RSDs were below 10% for all the sample types. This HPLC assay has been applied to determine amphotericin B in plasma and tissue samples taken during pharmacokinetic and tissue distribution studies in rats.  相似文献   

13.
The pharmacokinetics of the antidepressants amitriptyline oxide and trimipramine and their major metabolites amitriptyline, nor-triptyline and desmethyltrimipramine, were studied in twelve healthy male subjects (aged from 22 to 62 years) and twelve patients (aged from 25 to 73 years) with severe renal impairment (glomerular filtration rate < 10 ml/min). Oral single doses of 60 mg amitriptyline oxide and 50 mg trimipramine, separated by a washout period, were administered to all study participants. Blood and urine samples were collected up to 120 hours after administration. For trimipramine and desmethyltrimipramine, a new HPLC method was developed. The "Fischer Somatic and Undesired Effects Check List" was used for the assessment of adverse events. The mean plasma half-life and AUC of amitriptyline oxide and its metabolites were significantly higher in patients than in healthy adults. For trimipramine the AUC was significantly higher in patients. The plasma half-life of trimipramine was longer in patients, but statistically not significant. The maximum plasma concentrations for both drugs and metabolites were at an average distinctly higher in patients. Clearance rate of amitroptylinoxide and trimipramine also differed between the two groups. Correlating with these results a high incidence and a longer persistence (in most cases > 12 hours) and more pronounced adverse effects were noted in the patient group, whereas in volunteers adverse events were only observed up to approximately eight hours.  相似文献   

14.
One of the main metabolites of oracin (I) ?6-[2-(2-hydroxyethyl)aminoethyl]-5,11-dioxo-5,6-dihydro-11H-indeno[1,2- c] isoquinoline?, a potential cytostatic drug, is 11-dihydrooracin (II) ?(+),(-)-6-[2-(2-hydroxyethyl)aminoethyl]-5-oxo-11-hydroxy-5,6-dihydro-1 1H- indeno[1,2-c]isoquinoline?, a metabolite formed by the reduction of oracin's pro-chiral centre on C 11. This metabolite has been found in all laboratory species in vitro and in vivo and it constitutes the main metabolite in man. The stereospecificity of reducing enzymes participating in the oracin biotransformation pathway was investigated using microsomal preparations from standard laboratory animals. Enzyme stereospecificity has been defined as preferential formation by the enzyme of the (+) or (-) stereoisomer of II. Significant interspecies differences were observed in the stereospecificity of the respective biotransformation enzymes. HPLC quantitative determinations of both enantiomers were performed using a Chiralcel OD-R column as chiral stationary phase with excellent resolution and stability.  相似文献   

15.
This method describes the determination of propiomazine by direct injection of rat plasma into a chromatography system based on coupled reversed-phase columns. An extraction column, packed with porous silica particles with covalent-bound alpha1-acid glycoprotein (AGP), was used to separate the plasma proteins from the analyte. After isolation the analyte was transferred to the analytical column for separation and detection. Propiomazine was detected by an electrochemical detector and the limit of quantification was 2.0 ng/ml (100 pg injected). The absolute recovery was 80.9+/-2.4% at 9.0 ng/ml level. The inter-day and intra-day precision was 10.9% (5.6 ng/ml) and 2.8% (9.0 ng/ml), respectively.  相似文献   

16.
Because limited information is available about potential differences between the pharmacokinetics and pharmacodynamics of the enantiomers of lansoprazole, the enantioselective pharmacokinetics of the compound have been investigated in rats. There was a noticeable difference between the serum levels of the enantiomers of lansoprazole and of their metabolites, 5-hydroxylansoprazole enantiomers, after oral administration of the racemate (50 mg kg(-1)) to rats. Cmax (maximum serum concentration) and AUC (area under the serum concentration-time curve) for (+)-lansoprazole were 5-6 times greater than those for (-)-lansoprazole, whereas for (+)-5-hydroxylansoprazole both values were significantly smaller than those for the (-) enantiomer. CLtot/F values (where CLtot is total clearance and F is the fraction of the dose absorbed) for (+)-lansoprazole were significantly smaller than those for the (-) enantiomer. There was no significant difference between the absorption rate constants of the lansoprazole enantiomers in the in-situ absorption study. The in-vitro protein-binding study showed that binding of (+)-lansoprazole to rat serum proteins was significantly greater than for the (-) enantiomer. The in-vitro metabolic study showed that the mean metabolic ratio (45.9%) for (-)-lansoprazole was significantly greater than that (19.8%) for the (+) enantiomer in rat liver microsomes at 5.6 microM lansoprazole. These results show that the enantioselective disposition of lansoprazole could be a consequence of the enantioselectivity of plasma-protein binding and the hepatic metabolism of the enantiomers.  相似文献   

17.
A method is described for the measurement of pimozide in human plasma using HPLC with fluorescence detection. The method is specific and sensitive in the range of concentrations seen in human plasma after conventional dosing (1-15 ng/ml) with a limit of quantification of 1 ng/ml. The calibration curves are linear for concentrations between 1 and 50 ng/ml. Within-day and inter-day coefficients of variation are less than 7.4% and 15.5%, respectively, at three concentrations of pimozide (2, 10 and 20 ng/ml). Intra-day and inter-day bias are less than 18.5% and 12.5%, respectively. A pharmacokinetic study conducted in a healthy volunteer administered 6 mg of pimozide orally demonstrates the utility of this method.  相似文献   

18.
A sensitive analytical procedure is described for the simultaneous determination of lignocaine and the enantiomers of bupivacaine in biological fluids using diazepam as an internal standard. After solvent extraction into hexane, the local anaesthetics were separated using an alpha1-acid glycoprotein (AGP) column and detected at 214 nm. Calibration curves were linear (r2>0.99) in the concentration range of 5 to 500 ng/ml for the enantiomers of bupivacaine and 12.5 to 1000 ng/ml for lignocaine. The corresponding limits of detection were 4 ng/ml and 10 ng/ml, respectively. The method was applied to the analysis of plasma from a healthy woman undergoing tubal ligation.  相似文献   

19.
An analytical method for the determination of norethisterone acetate (NETA) in human plasma by capillary gas chromatography-mass-selective detection (GC-MS), with testosterone acetate as internal standard, was developed and validated. After addition of the internal standard, the compounds were extracted from plasma at basic pH into diethyl ether-dichloromethane (3:2, v/v), which was then evaporated to dryness. The compounds were converted into their pentafluoropropionyl derivatives which were determined by gas chromatography using a mass selective detector at m/z 486 for NETA and m/z 476 for the internal standard. Intra-day and inter-day accuracy and precision were found suitable over the range of concentrations between 0.10 to 10 ng/ml. The method was applied to clinical samples.  相似文献   

20.
The semi-automatic method for the determination of the bisphosphonate pamidronate in serum and citrate plasma involves a manual protein precipitation with trichloroacetic acid and a manual coprecipitation of the bisphosphonate with calcium phosphate, followed by an automated solid-phase extraction on anion-exchange columns. After off-line evaporation of the extract under nitrogen and reconstitution in water, the automatic procedure is continued by automatic derivatization with 1-naphthylisothiocyanate, ion-pair liquid-liquid extraction and a treatment with hydrogen peroxide, prior to analysis by ion-pair HPLC and fluorescence detection at 285/390 nm. The intra- and inter-day precisions are 1.3 and 7%, respectively, for a standard of 100 ng ml(-1) pamidronate in serum; the average accuracy for this standard is 107%. The lower limit of quantification is 20 ng ml(-1) pamidronate in 1 ml of human serum.  相似文献   