共查询到20条相似文献,搜索用时 15 毫秒
1.
Free-viewpoint images obtained from phase-shifting synthetic aperture digital holography are given for scenes that include multiple objects and a concave object. The synthetic aperture technique is used to enlarge the effective sensor size and to make it possible to widen the range of changing perspective in the numerical reconstruction. The lensless Fourier setup and its aliasing-free zone are used to avoid aliasing errors arising at the sensor edge and to overcome a common problem in digital holography, namely, a narrow field of view. A change of viewpoint is realized by a double numerical propagation and by clipping the wave field by a given pupil. The computational complexity for calculating an image in the given perspective from the base complex-valued image is estimated at a double fast Fourier transform. The experimental results illustrate the natural change of appearance in cases of both multiple objects and a concave object. 相似文献
2.
We present what we believe to be a new digital holographic imaging method that is able to determine simultaneously the distributions of intensity, phase, and polarization state at the surface of a specimen on the basis of a single image acquisition. Two reference waves with orthogonal polarization states interfere with the object wave to create a hologram that is recorded on a CCD camera. Two wave fronts, one for each perpendicular polarization state, are numerically reconstructed in intensity and phase. Combining the intensity and the phase distributions of these two wave fronts permits the determination of all the components of the Jones vector of the object-wave front. We show that this method can be used to image and measure the distribution of the polarization state at the surface of a specimen, and the obtained results indicate that precise quantitative measurements of the polarization state can be achieved. An application of the method to image the birefringence of a stressed polymethyl methacrylate sample is presented. 相似文献
3.
Directional synthetic aperture flow imaging 总被引:1,自引:0,他引:1
Jensen JA Nikolov SI 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2004,51(9):1107-1118
A method for flow estimation using synthetic aperture imaging and focusing along the flow direction is presented. The method can find the correct velocity magnitude for any flow angle, and full color flow images can be measured using only 32 to 128 pulse emissions. The approach uses spherical wave emissions with a number of defocused elements and a linear frequency-modulated pulse (chirp) to improve the signal-to-noise ratio. The received signals are dynamically focused along the flow direction and these signals are used in a cross-correlation estimator for finding the velocity magnitude. The flow angle is manually determined from the B-mode image. The approach can be used for both tissue and blood velocity determination. The approach was investigated using both simulations and a flow system with a laminar flow. The flow profile was measured with a commercial 7.5 MHz linear array transducer. A plastic tube with an internal diameter of 17 mm was used with an EcoWatt 1 pump generating a laminar, stationary flow. The velocity profile was measured for flow angles of 90 and 60 degrees. The RASMUS research scanner was used for acquiring radio frequency (RF) data from 128 elements of the array, using 8 emissions with 11 elements in each emission. A 20-micros chirp was used during emission. The RF data were subsequently beamformed off-line and stationary echo canceling was performed. The 60-degree flow with a peak velocity of 0.15 m/s was determined using 16 groups of 8 emissions, and the relative standard deviation was 0.36% (0.65 mm/s). Using the same setup for purely transverse flow gave a standard deviation of 1.2% (2.1 mm/s). Variation of the different parameters revealed the sensitivity to number of lines, angle deviations, length of correlation interval, and sampling interval. An in vivo image of the carotid artery and jugular vein of a healthy 29-year-old volunteer was acquired. A full color flow image using only 128 emissions could be made with a high-velocity precision. 相似文献
4.
5.
Bandyopadhyay A Stepanov A Schulkin B Federici MD Sengupta A Gary D Federici JF Barat R Michalopoulou ZH Zimdars D 《Journal of the Optical Society of America. A, Optics, image science, and vision》2006,23(5):1168-1178
The stand-off imaging properties of a terahertz (THz) interferometric array are examined. For this application, the imaged object is in the near-field region limit of the imaging array. In this region, spherical and circular array architectures can compensate for near-field distortions and increase the field of view and depth of focus. Imaging of THz point sources is emphasized to demonstrate the imaging method and to compare theoretical predictions to experimental performance. 相似文献
6.
A technique based on superresolution by digital holographic microscopic imaging is presented. We used a two dimensional (2-D) vertical-cavity self-emitting laser (VCSEL) array as spherical-wave illumination sources. The method is defined in terms of an incoherent superposition of tilted wavefronts. The tilted spherical wave originating from the 2-D VCSEL elements illuminates the target in transmission mode to obtain a hologram in a Mach-Zehnder interferometer configuration. Superresolved images of the input object above the common lens diffraction limit are generated by sequential recording of the individual holograms and numerical reconstruction of the image with the extended spatial frequency range. We have experimentally tested the approach for a microscope objective with an exact 2-D reconstruction image of the input object. The proposed approach has implementation advantages for applications in biological imaging or the microelectronic industry in which structured targets are being inspected. 相似文献
7.
Nikolov SI Jensen JA Tomov BG 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2008,55(8):1755-1767
This paper describes the design and implementation of a real-time delay-and-sum synthetic aperture beamformer. The beamforming delays and apodization coefficients are described parametrically. The image is viewed as a set of independent lines that are defined in 3D by their origin, direction, and inter-sample distance. The delay calculation is recursive and inspired by the coordinate rotation digital computer (CORDIC) algorithm. Only 3 parameters per channel and line are needed for their generation. The calculation of apodization coefficients is based on a piece- wise linear approximation. The implementation of the beamformer is optimized with respect to the architecture of a novel synthetic aperture real-time ultrasound scanner (SARUS), in which 4 channels are processed by the same set of field-programmable gate arrays (FPGA). In synthetic transmit aperture imaging, low-resolution images are formed after every emission. Summing all low-resolution images produces a perfectly focused high-resolution image. The design of the beamformer is modular, and a single beamformation unit can produce 4600 low-resolution images per second, each consisting of 32 lines and 1024 complex samples per line. In its present incarnation, 3 such modules fit in a single device. The summation of low-resolution images is performed internally in the FPGA to reduce the required bandwidth. The delays are calculated with a precision of 1/16th of a sample, and the apodization coefficients with 7-bit precision. The accumulation of low-resolution images is performed with 24-bit precision. The level of the side- and grating lobes, introduced by the use of integer numbers in the calculations and truncation of intermediate results, is below -86 dB from the peak. 相似文献
8.
O'Donnell M Wang Y 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2005,52(2):171-176
Peak acoustic power limits the signal-to-noise ratio (SNR) of real-time ultrasound images. For most conventional scan formats, however, the average power is well below heating limits. This means the SNR can be significantly increased using coded excitation. A coded system transmits a broadband, temporally elongated excitation pulse with a finite time-bandwidth product. The received signal must be decoded to produce an imaging pulse with improved SNR resulting from the higher average power in the elongated excitation. Decoding can produce significant range side lobes, however, greatly reducing image quality. All practical coding designs, therefore, represent a trade-off between SNR gain and range side lobes. A specific coding scheme appropriate for synthetic aperture imaging is presented. A 14.5 dB SNR improvement with acceptable range side lobes is demonstrated on a forward-looking imaging system appropriate for intravascular applications. 相似文献
9.
Ylitalo J.T. Ermert H. 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》1994,41(3):333-339
An ultrasound synthetic aperture imaging method based on a monostatic approach was studied experimentally. The proposed synthetic aperture method offers good dynamical resolution along with fast numerical reconstruction. In this study complex object data were recorded coherently in a two-dimensional hologram using a 3.5 MHz single transducer with a fairly wide-angle beam. Image reconstruction which applies the wavefront backward propagation method and the near-field curvature compensation was performed numerically in a microcomputer using the spatial frequency domain. This approach allows an efficient use of the FFT-algorithms. Because of the simple and fast scanning scheme and the efficient reconstruction algorithms the method can be made real-time. The image quality of the proposed method was studied by evaluating the spatial and dynamical resolution in a waterbath and in a typical tissue-mimicking phantom. The lateral as well as the range resolution (-6 dB) were approximately 1 mm in the depth range of 30-100 mm. The dynamical resolution could be improved considerably when the beam width was made narrower. Although it resulted in a slightly reduced spatial resolution this compromise has to be done for better resolution of low-contrast targets such as cysts. The study showed that cysts as small as 2 mm by diameter could be resolved 相似文献
10.
We present a scheme for radar imaging of satellites by the inverse synthetic aperture radar technique. We include some general principles in image formation when dealing with microwave-scattering experiments, such as radar observation of a satellite, so that the article is not confined to the radar community. We propose an original motion compensation algorithm for image autofocusing: This one-stage algorithm is faster than usual two-stage algorithms and turns to be quite accurate, which can be measured by quality criteria and visual inspection of reconstructed images. We show its application to imaging of the Russian space station Mir with two different radar systems. © 1998 John Wiley & Sons, Inc. Int J Imaging Syst Technol, 9, 24–28, 1998 相似文献
11.
Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging 总被引:1,自引:0,他引:1
O'Donnell M Thomas LJ 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》1992,39(3):366-380
Phased-array imaging, including complete dynamic focus, is explored for imaging using a circular aperture. Based on the constraints of catheter-based systems, an efficient synthetic aperture method has been developed for imaging using a single wire connection between the imaging array and external electronics. The method employs a highly sampled array with an element pitch small compared to the acoustic wavelength. On any given firing of the array, however, a large number of channels are electrically connected on both transmission and reception. From firing to firing, one element is dropped and one new element is included, in analogy to a classic linear array system. Using an optimal filtering approach for synthetic aperture reconstruction, a dynamically focused image exhibiting diffraction limited resolution is produced. The results of detailed simulations are presented demonstrating the capabilities of the method. In addition, the prospects for real-time implementation of the reconstruction are discussed. 相似文献
12.
13.
Glastre W Lacot E Jacquin O Hugon O de Chatellus HG 《Journal of the Optical Society of America. A, Optics, image science, and vision》2012,29(4):476-485
In this paper, we compare the sensitivity of two imaging configurations, both based on laser optical feedback imaging (LOFI). The first one is direct imaging, which uses conventional optical focalization on target, and the second one is made by a synthetic aperture (SA) laser, which uses numerical focalization. We show that SA configuration allows us to obtain good resolutions with high working distance and that the drawback of SA imagery is that it has a worse photometric balance in comparison to a conventional microscope. This drawback is partially compensated by the important sensitivity of LOFI. Another interest of SA relies on the capacity of getting three-dimensional information in a single x-y scan. 相似文献
14.
Gran F Jensen JA 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2006,53(5):900-911
In synthetic transmit aperture imaging only a few transducer elements are used in every transmission, which limits the signal-to-noise ratio (SNR). The penetration depth can be increased by using all transmitters in every transmission. In this paper, a method for exciting all transmitters in every transmission and separating them at the receiver is proposed. The coding is done by designing narrow-band linearly frequency modulated signals, which are approximately disjointed in the frequency domain and assigning one waveform to each transmitter. By designing a filterbank consisting of the matched filters corresponding to the excitation waveforms, the different transmitters can be decoded at the receiver. The matched filter of a specific waveform will allow information only from this waveform to pass through, thereby separating it from the other waveforms. This means that all transmitters can be used in every transmission, and the information from the different transmitters can be separated instantaneously. Compared to traditional synthetic transmit aperture (STA) imaging, in which the different transmitters are excited sequentially, more energy is transmitted in every transmission, and a better signal-to-noise-ratio is attained. The method has been tested in simulation, in which the resolution and contrast was compared to a standard synthetic transmit aperture system with a single sinusoid excitation. The resolution and contrast was comparable for the two systems. The method also has been tested using the experimental ultrasound scanner RASMUS. The resolution was evaluated using a string phantom. The method was compared to a conventional STA using both sinusoidal excitation and linear frequency modulated (FM) signals as excitation. The system using the FM signals and the frequency division approach yielded the same performance concerning both axial (of approximately equal to 3 wavelengths) and lateral resolution (of approximately equal to 4.5 wavelengths). A SNR measurement showed an increase in SNR of 6.5 dB compared to the system using the conventional STA method and FM signal excitation. 相似文献
15.
Peter T. Gough David W. Hawkins 《International journal of imaging systems and technology》1997,8(4):343-358
Imaging using synthetic aperture techniques is a mature technique with a host of different reconstruction algorithms available. Often the same basic algorithm has a different name depending on where the particular algorithm is used, since it may have originated from the medical, nondestructive testing, geological, or remote sensing fields. All this adds to confusion for the nonspecialist. This article gives a short historical precise of active synthetic aperture imaging as it applies to airborne, spaceborne, and underwater remote sensing systems using either radar or sonar, then defines some generic imaging geometry and places all the usable synthetic aperture reconstruction algorithms in a unified framework. This is done by the introduction of mapping operators, which simplify the mapping or reformatting of data from one sampling grid to another. Using these operators, readers can see how strip-map synthetic aperture systems (both radar- and sonar-based) differ from spotlight synthetic aperture systems, how the various algorithms fit together, and how the chirp-scaling algorithm is likely to be the reconstruction algorithm of choice for most future strip-map systems, and just why that should be so. Multilook processing and methods to deal with undersampled apertures using postdetection digital spotlighting are put into the same unified framework, as both of these techniques are frequent adjuncts to synthetic aperture imaging. © 1997 John Wiley & Sons, Inc. Int J Imaging Syst Technol, 8, 343–358, 1997 相似文献
16.
Because the existing range-Doppler algorithm in inverse synthetic aperture sonar (ISAS) is based on target model of uniform motion, it may be invalidated for maneuvering targets due to the time-varying changes of both individual scatter′s Doppler and imaging projection plane. To resolve the problem, a new range-instantaneous Doppler imaging method is proposed for imaging maneuvering targets based on time-frequency analysis. The proposed approach is verified using real underwater acoustic data. 相似文献
17.
Yamani A. 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》1997,44(4):943-947
The drawbacks of the multifrequency automatic focusing technique (MF-AFT) have been eased considerably when the scanned-frequency signals are transmitted simultaneously in a pulse. While the focusing capabilities of the MF-AFT are maintained, substantial reduction in data processing is obtained when the new procedure is used. In addition, the derived pulse can be tailored to further enhance the quality of the image produced by this new procedure. Simulation results are included to demonstrate the focusing capabilities of the procedure for both two- and three-dimensional objects 相似文献
18.
19.
Nikolov SI Jensen JA 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2003,50(7):848-856
A new method for acquiring flow images using synthetic aperture techniques in medical ultrasound is presented. The new approach makes it possible to have a continuous acquisition of flow data throughout the whole image simultaneously, and this can significantly improve blood velocity estimation. Any type of filter can be used for discrimination between tissue and blood flow without initialization, and the number of lines used for velocity estimation is limited only by the nonstationarity of the flow. The new approach is investigated through both simulations and measurements. A flow rig is used for generating a parabolic laminar flow, and a research scanner is used for acquiring RF data from individual transducer elements. A reference profile is calculated from a mass flow meter. The parabolic velocity profile is estimated using the new approach with a relative standard deviation of 2.2% and a mean relative bias of 3.4% using 24 pulse emissions at a flow angle of 45 degrees. The 24 emissions can be used for making a full-color flow map image. An in-vivo image of flow in the carotid artery for a 29-year-old male also is presented. The full image is acquired using 24 emissions. 相似文献