首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
An integrated airlift bioreactor system was developed, which mainly consists of a multi-stage loop reactor and a gas-liquid-solid separation baffle and possesses dual functions as bioreactor and settler. This integrated system was used for on-site treatment of industrial glycol wastewater in lab-scale. The strategy of gradually increasing practical wastewater concentration while maintaining the co-substrate glucose wastewater concentration helped to accelerate the microbial acclimation process. Investigation of microbial acclimation, operation parameters evaluation and microbial observation has demonstrated the economical and technical feasibility of this integrated airlift bioreactor system for on-site small industrial wastewater treatment.  相似文献   

2.
The Mexican petrochemical industry, Morelos S.A. de C.V., is one of the biggest and more important petroleum industries in Mexico and Latin America. It has an activated sludge system to treat its wastewater flow, which is approximately 7,000 m3/d. The wastewater contains volatile organic carbon substances classified as toxics. The old surface aeration system was changed for fine bubble diffusers; however, one major drawback of the new aeration system is that the temperature in the bioreactor has increased due to the compression of the air, which at the compressor exit reaches 85 degrees C. This effect results in the temperature in the bioreactor attaining 32 degrees C during the fall, whereas in the spring and summer, the bioreactor temperature reaches higher values than 40 degrees C. The high temperatures reduce the microorganism activity and cause a higher volatilisation rate of volatile compounds, among other effects, which affect the performance of the biological treatment. This work was performed to obtain a better modelling of the wastewater treatment from the petrochemical industry. The model describes the effect of the temperature on the performance of the biological treatment. The model was obtained from tests that were carried out in laboratory reactors with 14 L capacity, which were operated at different temperatures (from 30 to 45 degrees C), with the same wastewater and conditions as the actual system.  相似文献   

3.
This paper deals with the performance of hybrid membrane bioreactor (MBR) combining the precoagulation/sedimentation and membrane bioreactor. The hybrid MBR not only produces the treated water with excellent permeate quality but also shows much lower membrane fouling than the conventional MBR. It may come from its extremely low F/M ratio to maintain the low viscosity even in the high MLSS concentration range of about 20,000 mg/L. Some results of microbial community analysis in MBRs was conducted to demonstrate the other reason for its lower membrane fouling. Hybrid MBR has a high potential to be used for the recycling use of the municipal wastewater. Coagulated sludge produced in the hybrid MBR is a promising phosphorus resource. This paper also contains a recent progress of phosphorus recovery technology, which uses a new phosphoric acids absorbent, i.e. the hexagonal mesostructured zirconium sulfate (ZS). The ZS has the extremely high adsorption capacity of phosphoric acids through anion exchange. The adsorbed phosphoric acids are released from the ZS in a high pH range of about 13.  相似文献   

4.
开发了转运站污水厌氧生化调节池和基于混凝沉淀及高级氧化技术的快速处理设备,在转运站现场建立中试系统,优化系统运行的工艺参数,研究中试规模下组合工艺对转运站污水的处理效果,并进行了技术经济分析。该组合工艺可将CODCr从进水的15 000 mg/L降至1 230 mg/L,油脂从进水的10 000 mg/L以上降至50 mg/L,色度去除率在90%以上,出水澄清透明且无恶臭。  相似文献   

5.
A new hybrid membrane bioreactor (HMBR) has been developed to obtain a compact module, with a small footprint and low requirement for aeration. The aim of this research was to assess its performance. The system consists of a single vertical reactor with a filtration membrane unit and, above this, a sponge fixed bed as support medium. The aeration system is located under the membrane unit, allowing for membrane cleaning, oxygenation, biofilm thickness control and bulk liquid mixing. Operated under continuous aeration, a bench-scale reactor (70 L) was fed with pre-treated, raw (unsettled) municipal wastewater. BOD(5) and suspended solids removal efficiencies (96 and 99% respectively) were comparable to those obtained with other membrane bioreactors (MBRs). Total nitrogen removal efficiencies of 80% were achieved, which is better than those obtained in other HMBRs and similar to the values reached using more complex MBRs with extra anoxic tanks, intermittent aeration or internal deflectors.  相似文献   

6.
A pilot-scale fluidised pellet bed (FPB) bioreactor, which combines chemical coagulation, biological degradation, particle pelletisation and separation in one unit, was applied for onsite wastewater treatment and reuse. As a result of rational use of inorganic coagulant and organic polymer and moderate mechanical agitation, spherical particles were generated in the upflow column and a well-fluidised bed was formed. With a continuous supply of dissolved oxygen through a recycling loop, an aerobic condition was kept in the bottom section of the FPB column. Under such conditions the pellets in the FPB column showed the following characteristics: (1) compact structure and high density; (2) rich in microorganisms; and (3) high MLSS and MLVSS concentrations. Therefore, the FPB bioreactor achieved more than 90% removal of SS, COD, BOD and TP from raw domestic wastewater within a total hydraulic retention time (HRT) of only about 30 minutes. It also showed nitrification and denitrification ability and the TN removal could be about 50% as the recycling ratio was increased to 1:1. The treated water quality is generally competitive with the secondary effluent from a conventional activated sludge process. With these advantages the FPB bioreactor is recommendable as a compact system for onsite wastewater treatment and reuse.  相似文献   

7.
A medium-scale membrane bioreactor was tested in a large tourist resort on the south-western coast of Turkey with the treated wastewater subsequently being used for irrigational purposes. The wastewater treatment system was designed to eliminate carbonaceous and nitrogenous substances. Treatment efficiency was monitored by means of regular chemical and microbiological analyses. Information was collected on water use at different locations of the hotel. Specific values based on the number of guests were determined. Wastewater streams from kitchen, laundry and rooms were analysed to investigate the various contribution from these points. The social acceptance of the guests concerning the on-site wastewater treatment and reuse in the hotel was analysed using a questionnaire. The investigations indicated that the treated wastewater provides the required chemical and hygienic conditions to satisfy requirement for its reuse in irrigation. The acceptance by guests was encouraging for such applications.  相似文献   

8.
This work presents preliminary results for distillery wastewater treatment in a MBR equipped with filters prepared from waste fly ash. The system was fabricated locally and employed submerged membranes in the 2-8 microm pore-size range. Distillery wastewater, after anaerobic digestion, was used as the feed and the bioreactor was inoculated with sludge obtained from a local distillery unit. The MBR was operated for around 250 days. The wastewater quality was monitored in terms of COD (chemical oxygen demand), colour, phenol, and MLSS (mixed liquor suspended solids) concentration. An average COD and phenol removal of 36% and 60% respectively was obtained. The maximum suspended solids retention by the ash filter was as high as 98%. The results were encouraging and further trials are currently underway to improve the performance.  相似文献   

9.
Treatment of toilet wastewater for reuse in a membrane bioreactor.   总被引:1,自引:0,他引:1  
Toilet wastewater is treated and reused on site at Europe's highest membrane bioreactor (MBR), located in a cable car mountain station in the ski resort of Zermatt. Negative impacts on the sensitive mountain environment are minimised by reusing close to 100% of the treated wastewater for toilet flushing. Besides 100% nitrogen removal, 80% of phosphorus was also eliminated. This paper presents operational results, optimisations of sludge management, decoloration and long-term maintenance of biomass in the very low-loaded summer season. From a global view the experiences and results of the project are of great importance, proposing a solution to a problem existing 100-fold in the Alps as well as in arid regions all over the world: reducing water consumption for sanitation by reuse.  相似文献   

10.
The use of a membrane bioreactor (MBR) for removal of organic substances and nutrients from slaughterhouse plant wastewater was investigated. The chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) concentrations of slaughterhouse wastewater were found to be approximately 571 mg O2/L, 102.5 mg/L, and 16.25 mg PO4-P/L, respectively. A submerged type membrane was used in the bioreactor. The removal efficiencies for COD, total organic carbon (TOC), TP and TN were found to be 97, 96, 65, 44% respectively. The COD value of wastewater was decreased to 16 mg/L (COD discharge standard for slaughterhouse plant wastewaters is 160 mg/L). TOC was decreased to 9 mg/L (TOC discharge standard for slaughterhouse plant wastewaters is 20 mg/L). Ammonium, and nitrate nitrogen concentrations of treated effluent were 0.100 mg NH4-N/L, and 80.521 mg NO3-N/L, respectively. Slaughterhouse wastewater was successfully treated with the MBR process.  相似文献   

11.
MBR工艺处理城镇污水处理厂污泥水中试研究   总被引:2,自引:0,他引:2  
将平板膜组件与传统脱氮除磷工艺相结合,构建了膜生物反应器强化生物脱氮除磷中试系统,并用于处理城镇污水处理厂的污泥系统废水。结果表明,出水CODCr、BOD5、NH3—N、TN和TP的平均浓度分别为70.8 mg/L、8.7 mg/L、15.1 mg/L、29.7 mg/L和0.38 mg/L,达到或接近了《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级标准。  相似文献   

12.
Biological nitrogen removal in a membrane separation bioreactor developed for on-site domestic wastewater treatment was investigated. The bioreactor employed hollow fiber membrane modules for solid-liquid separation so that the biomass could be completely retained within the system. Intermittent aeration was supplied with 90 minutes on and off cycle to achieve nitrification and denitrification reaction for nitrogen removal. High COD and nitrogen removal of more than 90% were achieved under a moderate temperature of 25 degrees C. As the temperature was stepwise decreased from 25 to 5 degrees C, COD removal in the system could be constantly maintained while nitrogen removal was deteriorated. Nevertheless, increasing aeration supply could enhance nitrification at low temperature with benefit from complete retention of nitrifying bacteria within the system by membrane separation. At low operating temperature range of 5 degrees C, nitrogen removal could be recovered to more than 85%. A mathematical model considering diffusion resistance of limiting substrate into the bio-particle is applied to describe nitrogen removal in a membrane separation bioreactor. The simulation suggested that limitation of the oxygen supply was the major cause of inhibition of nitrification during temperature decrease. Nevertheless, increasing aeration could promote oxygen diffusion into the bio-particle. Sufficient oxygen was supplied to the nitrifying bacteria and the nitrification could proceed. In the membrane separation bioreactor, biomass concentration under low temperature operation was allowed to increase by 2-3 times of that of moderate temperature to compensate for the loss of bacterial activities so that the temperature effect was masked.  相似文献   

13.
The article presents a case-study on the calibration and verification of mathematical models of organic carbon removal kinetics in biofilm. The chosen Harrem?es and Wanner & Reichert models were calibrated with a set of model parameters obtained both during dedicated studies conducted at pilot- and lab-scales for petrochemical wastewater conditions and from the literature. Next, the models were successfully verified through studies carried out utilizing a pilot ASFBBR type bioreactor installed in an oil-refinery wastewater treatment plant. During verification the pilot biofilm reactor worked under varying surface organic loading rates (SOL), dissolved oxygen concentrations and temperatures. The verification proved that the models can be applied in practice to petrochemical wastewater treatment engineering for e.g. biofilm bioreactor dimensioning.  相似文献   

14.
A study was carried out on a hybrid (AS-SBF) membrane bioreactor (HMBR) for the municipal wastewater reclamation and reuse at Chengfengzhuang WWTP in Daqing City, Heilongjiang Province. It was found that the effects of DO and water temperature on performance of the HMBR was significant. Under the conditions of water temperature in range of 10-14 degrees C, pH of 6.6- 7.0, DO of 4-6 mg/l and HRT of 7 h, the HMBR exhibited removal efficiencies for CODcr, BOD5, NH3-N and TN of 96.7%, 98.9%, 93.7% and 60.5% respectively. The turbidity of effluent from HMBR was below 1 NTU. The effluent of HMBR meets the standard of wastewater reclamation for oil exploitation. PAC was added into the bioreactor at the second operating stage, in order to further research parameters variation. The flux was improved by 53.2%, compared to the membrane without PAC-addition, due to formation of a PAC pre-coat layer on the membrane surface, with lots of advantages such as larger granules, higher porosity, non-compressibility, higher filterability and easy removal, compared with pure biomass layer. In addition, the performance of HMBR was further improved, due to adsorption and degradation of SMPs, the average removal of CODcr and TN was further improved by 5.1% and 13.5% respectively. Biomass in the HMBR was quantitatively measured, of which the biofilm played a major role in pollutants removal.  相似文献   

15.
An up-flow inner-cycle anoxic bioreactor with a novel three phase separator was designed and implemented for the treatment of sulfide wastewater. The sulfide in wastewater could be converted to elemental sulfur by sulfide oxidizing bacteria, and recovered by simple precipitation. When the oxidation-reduction potential (ORP) was controlled at -100 mV, 91.3% of sulfide could be oxidized to elemental sulfur. To achieve high removal percentage of sulfide and conversion percentage of sulfur, the pH of influent should be controlled in the range from 7.0 to 8.0. The optimal desulfurization process was carried out at 400 mmol L(-1)d(-1) sulfide loading rate and 120 min hydraulic retention time (HRT). The removal percentage of sulfide was approximately 95.2% and elemental sulfur conversion percentage was above 90.3%. These results demonstrated that the novel up-flow in-cycle bioreactor had a potential value for the enhanced treatment of sulfide wastewater from biogas purification.  相似文献   

16.
Cytostatic agents are applied in cancer therapy and subsequently excreted into hospital wastewater. As these substances are known to be carcinogenic, mutagenic and toxic for reproduction, they should be removed from wastewater at their source of origin.In this study the fate and effects of the cancerostatic platinum compounds (CPC) cisplatin, carboplatin, oxaliplatin, 5-fluorouracil (5-FU) and the anthracyclines doxorubicin, daunorubicin and epirubicin were investigated in hospital wastewater. Wastewater from the in-patient treatment ward of a hospital in Vienna was collected and monitored for the occurrence of the selected drugs. A calculation model was established to spot the correlation between administered dosage and measured concentrations. To investigate the fate of the selected substances during wastewater treatment, the oncologic wastewater was treated in a pilot membrane bioreactor system (MBR) and in downstream advanced wastewater treatment processes (adsorption to activated carbon and UV-treatment). Genotoxic effects of the oncologic wastewater were assessed before and after wastewater treatment followed by a risk assessment.Monitoring concentrations of the selected cytostatics in the oncologic wastewater were in line with calculated concentrations. Due to different mechanisms (adsorption, biodegradation) in the MBR-system 5 - FU and the anthracyclines were removed < LOD, whereas CPC were removed by 60%. In parallel, genotoxic effects could be reduced significantly by the MBR-system. The risk for humans, the aquatic and terrestrial environment by hospital wastewater containing cytostatic drugs was classified as small in a preliminary risk assessment.  相似文献   

17.
MBR-technology is able to fulfil similar or even higher standard for nutrients removal than conventional activated sludge processes. This paper presents the optimisation of the membrane bioreactor technology, together with a low pressure sewer, to equip a remote and yet unsewered area of Berlin requiring high quality wastewater treatment. The hydraulic flow pattern of the entire system has to be studied carefully due to the small collection system (no time delay between wastewater discharge and treatment to minimise the daily profile). The pollutant concentrations in the wastewater exhibit also stronger variations. In order to flatten out the hydraulic and load profile, and therefore to reduce the size of the biological reactor and the membrane surface, a buffer tank was installed before the MBR-plant. A full analysis of the influent hydraulic flow and wastewater characterisation is provided for the demonstration MBR-plant.  相似文献   

18.
The long start-up period of fluidized bed biofilm reactors is a serious obstacle for their wide installation in the anaerobic treatment of industrial wastewater. This paper presents the results of an anaerobic inverse turbulent bioreactor treating distillery wastewater during 117 days of operation at a laboratory scale. The pre-colonized bioparticles for this work were obtained from a similar reactor processing the same wastewater and which had a start-up period of 3 months. The system attained carbon removal efficiency rates between 70 and 92%, at an organic loading rate of 30.6 kg m(-3) d(-1) (chemical oxygen demand) with a hydraulic retention time of 11.1 h. The results obtained showed that the start-up period of this kind of reactors can be reduced by 3 using pre-colonized bioparticles.  相似文献   

19.
地下式污水泵站的传统砂渣外运方式会给操作人员的健康带来隐患。以青岛某地下式污水泵站为例,日常运行时操作人员无需进入污水泵站内即可完成砂渣的自动收集与提升外运,提出了地下式污水泵站砂渣自动收集与提升系统的设计方案,并对其可行性进行探讨。  相似文献   

20.
The stability of a fed-batch bioreactor operated with a new control strategy (ED-TOC) during a long-term period was evaluated. The ED-TOC strategy uses solely measurements of DO concentration and volume of the reactor to control the influent flow rate, and so the substrate degradation rate oscillates around its maximal value during the whole filling phase. The bioreactor was tested for the degradation of a wastewater containing 4-chlorophenol (4CP) as a model of an inhibitory compound. The experiment was conducted twice in order to investigate whether results were reproducible. Each set of experiments consisted of two phases: acclimation of the biomass to 4-chlorophenol and operation using the ED-TOC strategy. The main conclusion is that the reactor operated by the ED-TOC strategy is robust and stable in large operation periods. Degradation efficiencies greater than 99% as 4CP and greater than 97% as COD degradation were obtained. Toxicity analysis demonstrates that the bioreactor operated by ED-TOC eliminates the toxicity in the wastewater. Community analysis by DGGE was also conducted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号