首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到16条相似文献,搜索用时 609 毫秒
1.
两侧边开缝钢板剪力墙弹性屈曲分析   总被引:1,自引:0,他引:1  
提出一种新型的两侧边开缝的钢板剪力墙,并对其两侧边有无加劲肋的两种结构形式进行有限元弹性屈曲分析,分别讨论其临界屈曲荷载和屈曲模态.对两侧无加劲肋的钢板剪力墙,给出用于其设计的屈曲系数公式,对两侧有加劲肋的钢板剪力墙给出具有参考价值的设计建议.  相似文献   

2.
全加劲两侧开缝钢板剪力墙弹性屈曲研究   总被引:3,自引:0,他引:3  
采用有限元方法对全加劲两侧开缝钢板剪力墙在面内水平荷载作用下的弹性屈曲临界荷载、屈曲模态进行了研究。对影响其弹性屈曲性能的参数进行了分析,包括两侧和中部加劲肋与墙板的刚度比、两侧和中部加劲肋宽厚比以及墙板高厚比和边长比。给出了全加劲两侧开缝钢板剪力墙加劲肋的弹性屈曲设计参考公式,为开缝钢板剪力墙的应用提供依据。  相似文献   

3.
郑悦  赵伟 《工业建筑》2011,41(9):124-126,130
目前钢板剪力墙抗剪设计中假定周边框架为钢板剪力墙提供简支约束,再通过乘以1.23的嵌固系数来考虑周边框架的约束作用,而不考虑周边框架刚度的影响。通过对剪力和单向压力组合作用下钢板剪力墙的弹性屈曲性能的有限元分析表明,两侧边构件扭转刚度与钢板剪力墙弯曲刚度的比值η可以准确地衡量两侧边构件(加劲肋)对钢板剪力墙的约束程度。...  相似文献   

4.
通过对剪切作用下的闭口斜加劲钢板剪力墙进行有限元弹性屈曲分析,研究了肋板刚度比和抗扭抗弯刚度比对斜向槽钢加劲钢板剪力墙剪切屈曲性能及其加劲门槛刚度的影响。通过有限元分析,得到了斜向加劲钢板剪力墙临界剪切屈曲应力随内填板跨高比和加劲肋抗扭抗弯刚度比变化的关系曲线。考虑加劲肋对内填板加劲边转动约束,提出了第二门槛刚度,并给出了具有良好精度的斜向槽钢加劲钢板剪力墙的门槛刚度及第二门槛刚度计算公式。研究结果表明,受压型加劲肋对加劲板的临界剪切屈曲应力提高明显,随肋板刚度比的增大,加劲板的剪切屈曲应力增大,而受拉型加劲肋对板的屈曲荷载提高有限;当肋板刚度比达到第二门槛刚度时,加劲肋可以完全约束加劲边的面外位移和转动。当提高加劲肋的抗扭抗弯刚度比时,能够有效降低加劲肋的门槛刚度,因此,建议加劲肋的抗扭抗弯刚度比不低于0.307。  相似文献   

5.
竖向加劲钢板剪力墙门槛刚度研究   总被引:1,自引:1,他引:0  
赵伟  周观根  吴冲  赵剑丽 《工业建筑》2013,43(1):104-107
为研究设置竖向加劲肋的钢板剪力墙的弹性屈曲性能,采用有限元法对竖向加劲钢板剪力墙弹性屈曲性能进行研究,分析加劲肋的刚度、加劲数量和钢板高宽比等因素的影响。研究表明:设置竖向加劲能有效提高钢板墙剪切临界应力,钢板高宽比、加劲肋数目和加劲肋抗弯刚度均对钢板剪力墙屈曲系数有较大影响。提出加劲肋门槛刚度的判定标准和计算公式,该判定标准考虑了加劲肋扭转刚度的影响。与有限元结果的比较表明,具有较好的精度,且明显优于文献结果。  相似文献   

6.
工字形加劲肋带缝钢板剪力墙具有延性好、耗能能力强等优点,可有效避免钢板剪力墙对框架柱产生附加荷载而导致相邻框架柱过早发生破坏。对带缝钢板剪力墙以及工字形加劲肋带缝钢板剪力墙的弹性屈曲特征、滞回性能、应力、应变分布规律等力学性能进行了对比分析。结果表明,工字形加劲肋带缝钢板剪力墙的屈曲临界荷载为无加劲肋带缝钢板剪力墙屈曲临界荷载的2.15倍;工字形带缝钢板剪力墙的滞回曲线稳定且饱满,强化阶段被充分发挥,其抗侧承载力、延性及耗能能力显著提高;工字形加劲肋带缝钢板剪力墙用钢量系数比无加劲肋带缝钢板剪力墙降低了16%。  相似文献   

7.
李然  郭兰慧  张素梅 《工业建筑》2011,41(7):107-113
两边连接钢板剪力墙侧边由于受压屈曲产生较大变形,削弱其承载力和耗能能力。在两侧边采取加劲措施可以增强两侧边的稳定性,并在一定程度上提高承载能力和耗能能力。采用ANSYS有限元软件对侧边理想加劲的两边连接钢板剪力墙进行滞回分析,研究在理想加劲情况下,加劲肋对两边连接钢板剪力墙受力模式、承载能力和耗能能力的影响。分析结果表...  相似文献   

8.
侯蕾  刘皓 《山西建筑》2010,36(4):64-65
运用ANSYS有限元软件对高厚比在200~800范围内的纵横加劲肋钢板剪力墙进行了弹性屈曲性能分析,以了解加劲板弹性屈曲应力对比用钢量是否有相应的增加程度,从而为纵横加劲肋钢板剪力墙屈曲性能分析提供依据。  相似文献   

9.
《工业建筑》2017,(9):120-128
采用ABAQUS软件对中部开洞、一侧开洞及两侧开洞的钢板剪力墙进行了数值分析。对不同开洞形式的钢板剪力墙进行了弹性屈曲分析和非线性滞回分析,研究了洞口加劲肋刚度、强度对开洞钢板剪力墙性能的影响。研究结果表明:增大加劲肋刚度,可提高开洞钢板剪力墙的弹性屈曲应力,当肋板刚度比超过所提出的下限时,加劲肋对开洞钢板剪力墙屈曲应力的提高幅度降低;宽高比较大时,加劲肋对开洞钢板剪力墙屈曲应力的提高更加显著,在相同的肋板刚度比条件下,宽厚比不同的开洞钢板剪力墙屈曲应力的提高幅度基本相同。建议中部开洞、一侧开洞及两侧开洞钢板剪力墙的肋板刚度比下限分别取30,15和25。滞回分析结果表明:肋板刚度比对开洞钢板剪力墙弹性刚度、承载力和耗能能力影响较小。加劲肋强度过低时,无法充分发挥钢板剪力墙屈曲后的拉力场作用。按所提出的强度验算公式设计的加劲肋,可为开洞钢板剪力墙拉力场提供可靠锚固,确保拉力场充分发展。  相似文献   

10.
侯蕾  矫铨 《建筑设计管理》2010,27(10):45-48
主要的研究对象为不同边框连接条件下、高厚比在400~800范围内的纵横加劲肋薄钢板剪力墙弹性屈曲性能分析.研究表明,加劲肋钢板剪力墙的屈曲均为相关屈曲,〈高层民用建筑钢结构技术规程〉(JGJ99-98)在特定条件下过高估计了纵横加劲肋钢板剪力墙的弹性屈曲承载力.本文提出了设计建议.  相似文献   

11.
This paper presents the study of steel plate shear walls which are connected to frame beams only. As the shear walls are not connected to frame columns, the premature failure overall buckling or local buckling of frame columns can be prevented. In fact, most of both structural design engineers and architects prefer this kind of steel plate shear walls because the dimension of their opening space is relatively flexible by using several steel plates with small span-to-height ratio placed parallel to each other. In this paper, two steel plate shear walls were fabricated and tested. The influence of stiffeners on the hysteretic behavior of this kind of member was studied. The experimental results showed that this kind of specimen had good ductility and energy dissipation capacity. The energy dissipation capacity of specimen with stiffeners was larger than that of the specimens without stiffeners. Meanwhile, the finite element method was applied to analyze the behavior of steel plate shear walls, whose results were validated by comparing with the corresponding experimental results. Analytical results showed that the free edges deformed with evident out-of-plane deformation and should be constrained by stiffeners to meet the design requirements. The energy dissipation capacity is much better for steel plate shear walls with lower height-to-thickness ratio and larger span-to-height ratio. At last, the skeleton curve of steel plate shear wall was proposed for calculating the elastic rigidity and load-carrying capacity.  相似文献   

12.
钢板剪力墙低周反复荷载试验研究   总被引:34,自引:0,他引:34       下载免费PDF全文
本文进行了6个13比例钢板剪力墙的低周反复荷载试验,重点研究了钢板墙极限承载力和滞回性能,为钢板墙结构利用屈曲后强度及抗震设计提供试验依据;本试验揭示了边柱局部屈曲、加劲肋布置形式、加劲板刚度和板高厚比对钢板墙滞回性能的影响。试验结果表明,边柱不出现局部屈曲是钢板墙发挥极限承载力的重要保证;厚板和较强的加劲肋对提高钢板墙滞回曲线的饱满度和滞回环面积是有利的;三种钢板墙以交叉加劲板的承载力和滞回性能最佳,十字加劲板次之,钢板墙结构耗能能力依赖于钢板与边柱的弹塑性变形和钢板面外鼓曲变形。试验曲线与应用弹塑性大挠度有限元法计算的滞回曲线吻合良好;利用屈曲后强度的钢板墙受剪承载力,其试验值与本课题建议公式及有限元值计算结果基本一致。  相似文献   

13.
以交叉加劲钢板深梁为研究对象,利用有限元软件ANSYS分析其弹性屈曲性能,讨论了抗弯刚度比、跨高比、钢板深梁厚度对其弹性屈曲性能的影响;考虑钢板深梁在钢框架的弯剪受力特性,根据板的经典理论建立了交叉加劲钢板深梁屈曲荷载计算公式,提出了等效屈曲系数。结果表明:交叉加劲钢板深梁的临界屈曲荷载随抗弯刚度比增大而增大,但达到门槛刚度比后,增大幅度急剧减小,得到门槛刚度比约为10;临界屈曲荷载随跨高比和板厚的减小而减小,等效屈曲系数随板厚减小而增大;等效屈曲系数与跨高比关系曲线由二次抛物线形向波浪形渐变,交叉加劲钢板深梁受力特性由剪切主导向弯曲主导过渡。  相似文献   

14.
十字加劲钢板剪力墙的抗剪极限承载力   总被引:13,自引:1,他引:13       下载免费PDF全文
我国《高层民用建筑钢结构技术规程》规定了钢板墙剪切弹性屈曲不先于剪切屈服,其明显的不足是没有利用板的屈曲后强度,同时弹性屈曲也不能作为结构在弹塑性阶段的设计指标。本文应用板的大挠度弹塑性有限元方法对十字加劲方形钢板剪力墙的屈曲后性能和极限承载力进行了系统的研究,并在大量数值分析的基础上,提出了以板的平均剪切应变相应的剪应力作为钢板剪力墙承载能力的极限状态,以达到利用薄板屈曲后强度的目的,进而提出了钢板剪力墙承载力的设计简化计算公式及钢板墙侧柱刚度阈值的计算公式,供设计参考。数值计算结果表明,影响钢板墙抗剪性能主要有三个参数:板高厚比、肋板刚度比和边柱刚度。  相似文献   

15.
为改善自复位钢板剪力墙结构中由钢板墙对框架柱的附加弯矩造成的框架柱截面尺寸增大及平钢板剪力墙过早屈曲导致的承载力下降的情况,提出一种采用侧边加劲半圆形波纹钢板剪力墙的自复位钢框架-半圆形波纹钢板剪力墙,通过对其各组成部分的力学特性进行分析得到自复位钢框架-半圆形波纹钢板剪力墙的恢复力模型及影响其可恢复性的关键点和参数....  相似文献   

16.
剪压荷载作用下钢板剪力墙弹性屈曲性能研究   总被引:2,自引:2,他引:0  
郑悦  赵伟 《工业建筑》2011,41(8):105-109
国内外对钢板剪力墙的研究较少考虑竖向荷载的影响,这与工程实际不符。为准确估算钢板剪力墙承受竖向荷载后的弹性屈曲性能,对四边简支,两侧边固支、上下边简支和四边固支矩形钢板剪力墙在剪压作用下的弹性稳定性能进行有限元分析。根据有限元计算结果,修正不同边界条件钢板剪力墙剪压荷载下的相关屈曲计算公式,与有限元结果比较表明,修正后...  相似文献   